-
The LHCb upgrade I
Authors:
LHCb collaboration,
R. Aaij,
A. S. W. Abdelmotteleb,
C. Abellan Beteta,
F. Abudinén,
C. Achard,
T. Ackernley,
B. Adeva,
M. Adinolfi,
P. Adlarson,
H. Afsharnia,
C. Agapopoulou,
C. A. Aidala,
Z. Ajaltouni,
S. Akar,
K. Akiba,
P. Albicocco,
J. Albrecht,
F. Alessio,
M. Alexander,
A. Alfonso Albero,
Z. Aliouche,
P. Alvarez Cartelle,
R. Amalric,
S. Amato
, et al. (1298 additional authors not shown)
Abstract:
The LHCb upgrade represents a major change of the experiment. The detectors have been almost completely renewed to allow running at an instantaneous luminosity five times larger than that of the previous running periods. Readout of all detectors into an all-software trigger is central to the new design, facilitating the reconstruction of events at the maximum LHC interaction rate, and their select…
▽ More
The LHCb upgrade represents a major change of the experiment. The detectors have been almost completely renewed to allow running at an instantaneous luminosity five times larger than that of the previous running periods. Readout of all detectors into an all-software trigger is central to the new design, facilitating the reconstruction of events at the maximum LHC interaction rate, and their selection in real time. The experiment's tracking system has been completely upgraded with a new pixel vertex detector, a silicon tracker upstream of the dipole magnet and three scintillating fibre tracking stations downstream of the magnet. The whole photon detection system of the RICH detectors has been renewed and the readout electronics of the calorimeter and muon systems have been fully overhauled. The first stage of the all-software trigger is implemented on a GPU farm. The output of the trigger provides a combination of totally reconstructed physics objects, such as tracks and vertices, ready for final analysis, and of entire events which need further offline reprocessing. This scheme required a complete revision of the computing model and rewriting of the experiment's software.
△ Less
Submitted 17 May, 2023;
originally announced May 2023.
-
The STEREO Experiment
Authors:
N. Allemandou,
H. Almazán,
P. del Amo Sanchez,
L. Bernard,
C. Bernard,
A. Blanchet,
A. Bonhomme,
G. Bosson,
O. Bourrion,
J. Bouvier,
C. Buck,
V. Caillot,
M. Chala,
P. Champion,
P. Charon,
A. Collin,
P. Contrepois,
G. Coulloux,
B. Desbrières,
G. Deleglise,
W. El Kanawati,
J. Favier,
S. Fuard,
I. Gomes Monteiro,
B. Gramlich
, et al. (40 additional authors not shown)
Abstract:
The STEREO experiment is a very short baseline reactor antineutrino experiment aiming at testing the hypothesis of light sterile neutrinos as an explanation of the deficit of the observed neutrino interaction rate with respect to the predicted rate, known as the Reactor Antineutrino Anomaly. The detector center is located 10 m away from the compact, highly $^{235}$U enriched core of the research n…
▽ More
The STEREO experiment is a very short baseline reactor antineutrino experiment aiming at testing the hypothesis of light sterile neutrinos as an explanation of the deficit of the observed neutrino interaction rate with respect to the predicted rate, known as the Reactor Antineutrino Anomaly. The detector center is located 10 m away from the compact, highly $^{235}$U enriched core of the research nuclear reactor of the Institut Laue Langevin in Grenoble, France. This paper describes the STEREO site, the detector components and associated shielding designed to suppress the external sources of background which were characterized on site. It reports the performances in terms of detector response and energy reconstruction.
△ Less
Submitted 14 August, 2018; v1 submitted 24 April, 2018;
originally announced April 2018.
-
Test in a beam of large-area Micromegas chambers for sampling calorimetry
Authors:
C. Adloff,
M. Chefdeville,
A. Dalmaz,
C. Drancourt,
R. Gaglione,
N. Geffroy,
J. Jacquemier,
Y. Karyotakis,
I. Koletsou,
F. Peltier,
J. Samarati,
G. Vouters
Abstract:
Application of Micromegas for sampling calorimetry puts specific constraints on the design and performance of this gaseous detector. In particular, uniform and linear response, low noise and stability against high ionisation density deposits are prerequisites to achieving good energy resolution. A Micromegas-based hadronic calorimeter was proposed for an application at a future linear collider exp…
▽ More
Application of Micromegas for sampling calorimetry puts specific constraints on the design and performance of this gaseous detector. In particular, uniform and linear response, low noise and stability against high ionisation density deposits are prerequisites to achieving good energy resolution. A Micromegas-based hadronic calorimeter was proposed for an application at a future linear collider experiment and three technologically advanced prototypes of 1$\times$1 m$^{2}$ were constructed. Their merits relative to the above-mentioned criteria are discussed on the basis of measurements performed at the CERN SPS test-beam facility.
△ Less
Submitted 3 May, 2014;
originally announced May 2014.
-
Recent results of Micromegas sDHCAL with a new readout chip
Authors:
C. Adloff,
J. Blaha,
J. -J. Blaising,
M. Chefdeville,
A. Dalmaz,
C. Drancourt,
A. Espargilière,
R. Gaglione,
N. Geffroy,
J. Jacquemier,
Y. Karyotakis,
F. Peltier,
J. Prast,
S. Tsigaridas,
Y. Tsipolitis,
G. Vouters
Abstract:
Calorimetry at future linear colliders could be based on a particle flow approach where granularity is the key to high jet energy resolution. Among different technologies, Micromegas chambers with 1 cm2 pad segmentation are studied for the active medium of a hadronic calorimeter. A chamber of 1 m2 with 9216 channels read out by a low noise front-end ASIC called MICROROC has recently been construct…
▽ More
Calorimetry at future linear colliders could be based on a particle flow approach where granularity is the key to high jet energy resolution. Among different technologies, Micromegas chambers with 1 cm2 pad segmentation are studied for the active medium of a hadronic calorimeter. A chamber of 1 m2 with 9216 channels read out by a low noise front-end ASIC called MICROROC has recently been constructed and tested. Chamber design, ASIC circuitry and preliminary test beam results are reported.
△ Less
Submitted 3 February, 2012;
originally announced February 2012.
-
Micromegas for imaging hadronic calorimetry
Authors:
C. Adloff,
J. Blaha,
S. Cap,
M. Chefdeville,
A. Dalmaz,
C. Drancourt,
A. Espargiliere,
R. Gaglione,
R. Gallet,
N. Geffroy,
J. Jacquemier,
Y. Karyotakis,
F. Peltier,
J. Prast,
G. Vouters
Abstract:
The recent progress in R&D of the Micromegas detectors for hadronic calorimetry including new engineering-technical solutions, electronics development, and accompanying simulation studies with emphasis on the comparison of the physics performance of the analog and digital readout is described. The developed prototypes are with 2 bit digital readout to exploit the Micromegas proportional mode and t…
▽ More
The recent progress in R&D of the Micromegas detectors for hadronic calorimetry including new engineering-technical solutions, electronics development, and accompanying simulation studies with emphasis on the comparison of the physics performance of the analog and digital readout is described. The developed prototypes are with 2 bit digital readout to exploit the Micromegas proportional mode and thus improve the calorimeter linearity. In addition, measurements of detection efficiency, hit multiplicity, and energy shower profiles obtained during the exposure of small size prototypes to radioactive source quanta, cosmic particles and accelerator beams are reported. Eventually, the status of a large scale chamber (1{\times}1 m2) are also presented with prospective towards the construction of a 1 m3 digital calorimeter consisting of 40 such chambers.
△ Less
Submitted 7 February, 2011;
originally announced February 2011.
-
MICROMEGAS chambers for hadronic calorimetry at a future linear collider
Authors:
C. Adloff,
D. Attie,
J. Blaha,
S. Cap,
M. Chefdeville,
P. Colas,
A. Dalmaz,
C. Drancourt,
A. Espargiliere,
R. Gaglione,
R. Gallet,
N. Geffroy,
I. Giomataris,
J. Jaquemier,
Y. Karyotakis,
F. Peltier,
J. Prast,
G. Vouters
Abstract:
Prototypes of MICROMEGAS chambers, using bulk technology and analog readout, with 1x1cm2 readout segmentation have been built and tested. Measurements in Ar/iC4H10 (95/5) and Ar/CO2 (80/20) are reported. The dependency of the prototypes gas gain versus pressure, gas temperature and amplification gap thickness variations has been measured with an 55Fe source and a method for temperature and press…
▽ More
Prototypes of MICROMEGAS chambers, using bulk technology and analog readout, with 1x1cm2 readout segmentation have been built and tested. Measurements in Ar/iC4H10 (95/5) and Ar/CO2 (80/20) are reported. The dependency of the prototypes gas gain versus pressure, gas temperature and amplification gap thickness variations has been measured with an 55Fe source and a method for temperature and pressure correction of data is presented. A stack of four chambers has been tested in 200GeV/c and 7GeV/c muon and pion beams respectively. Measurements of response uniformity, detection efficiency and hit multiplicity are reported. A bulk MICROMEGAS prototype with embedded digital readout electronics has been assembled and tested. The chamber layout and first results are presented.
△ Less
Submitted 21 September, 2009; v1 submitted 17 September, 2009;
originally announced September 2009.