Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
Skip to main content

Showing 1–9 of 9 results for author: Schill, C

Searching in archive physics. Search in all archives.
.
  1. arXiv:1410.1797  [pdf, other

    physics.ins-det hep-ex

    The COMPASS Setup for Physics with Hadron Beams

    Authors: Ph. Abbon, C. Adolph, R. Akhunzyanov, Yu. Alexandrov, M. G. Alexeev, G. D. Alexeev, A. Amoroso, V. Andrieux, V. Anosov, A. Austregesilo, B. Badelek, F. Balestra, J. Barth, G. Baum, R. Beck, Y. Bedfer, A. Berlin, J. Bernhard, K. Bicker, E. R. Bielert, J. Bieling, R. Birsa, J. Bisplinghoff, M. Bodlak, M. Boer , et al. (207 additional authors not shown)

    Abstract: The main characteristics of the COMPASS experimental setup for physics with hadron beams are described. This setup was designed to perform exclusive measurements of processes with several charged and/or neutral particles in the final state. Making use of a large part of the apparatus that was previously built for spin structure studies with a muon beam, it also features a new target system as well… ▽ More

    Submitted 7 October, 2014; originally announced October 2014.

    Comments: 91 pages, 101 figures and 7 tables

  2. arXiv:1112.4291  [pdf, other

    physics.ins-det hep-ex

    The GANDALF 128-Channel Time-to-Digital Converter

    Authors: Maximilian Büchele, Horst Fischer, Florian Herrmann, Kay Königsmann, Christian Schill, Sebastian Schopferer

    Abstract: The GANDALF 6U-VME64x/VXS module has been designed to cope with a variety of readout tasks in high energy and nuclear physics experiments, in particular the COMPASS experiment at CERN. The exchangeable mezzanine cards allow for an employment of the system in very different applications such as analog-to-digital or time-to-digital conversions, coincidence matrix formation, fast pattern recognition… ▽ More

    Submitted 19 December, 2011; originally announced December 2011.

    Comments: 8 pages, 9 figures to be published in Physics Procedia

    Journal ref: Physics Procedia, Volume 37, 2012, Pages 1827-1834

  3. arXiv:1112.4281  [pdf, other

    physics.ins-det hep-ex

    Development and Performance Verification of the GANDALF High-Resolution Transient Recorder System

    Authors: Stefan Bartknecht, Horst Fischer, Florian Herrmann, Kay Königsmann, Louis Lauser, Christian Schill, Sebastian Schopferer, Heiner Wollny

    Abstract: With present-day detectors in high energy physics one often faces fast analog pulses of a few nanoseconds length which cover large dynamic ranges. In many experiments both amplitude and timing information have to be measured with high accuracy. Additionally, the data rate per readout channel can reach several MHz, which leads to high demands on the separation of pile-up pulses. For an upgrade of… ▽ More

    Submitted 19 December, 2011; originally announced December 2011.

    Comments: 5 pages, 9 figures

    Journal ref: IEEE Transactions on Nuclear Science, vol.58, no.4, pp.1456-1459, Aug. 2011

  4. Implementation of mean-timing and subsequent logic functions on an FPGA

    Authors: J. Bieling, G. Ahluwalia, J. Barth, F. Klein, J. Pretz, H. Fischer, F. Herrmann, C. Schill, S. Schopferer

    Abstract: This article describes the implementation of a mean-timer and coincidence logic on a Virtex-5 FPGA for trigger purposes in a particle physics experiment. The novel feature is that the mean-timing and the coincidence logic are not synchronized with a clock which allows for a higher resolution of approximately 400 ps, not limited by a clock frequency.

    Submitted 18 January, 2012; v1 submitted 22 September, 2011; originally announced September 2011.

    Comments: 15 pages, 11 figures

  5. arXiv:0902.0444  [pdf, ps, other

    physics.ins-det hep-ex

    Pattern recognition and PID for COMPASS RICH-1

    Authors: P. Abbon, M. Alexeev, H. Angerer, R. Birsa, P. Bordalo, F. Bradamante, A. Bressan, M. Chiosso, P. Ciliberti, M. L. Colantoni, T. Dafni, S. Dalla Torre, E. Delagnes, O. Denisov, H. Deschamps, V. Diaz, N. Dibiase, V. Duic, W. Eyrich, A. Ferrero, M. Finger, M. Finger Jr, H. Fischer, S. Gerassimov, M. Giorgi , et al. (44 additional authors not shown)

    Abstract: A package for pattern recognition and PID by COMPASS RICH-1 has been developed and used for the analysis of COMPASS data collected in the years 2002 to 2004, and 2006-2007 with the upgraded RICH-1 photon detectors. It has allowed the full characterization of the detector in the starting version and in the upgraded one, as well as the PID for physics results. We report about the package structure… ▽ More

    Submitted 3 February, 2009; originally announced February 2009.

    Comments: 4 pages, 4 figures,to appear in the proceedings of 6th International Workshop on Ring Imaging Cherenkov Counters (RICH 2007), Trieste, Italy, 15-20 Oct 2007

    Journal ref: Nucl.Instrum.Meth.A595:233-236,2008

  6. The Fast Read-out System for the MAPMTs of COMPASS RICH-1

    Authors: C. Schill

    Abstract: A fast readout system for the upgrade of the COMPASS RICH detector has been developed and successfully used for data taking in 2006 and 2007. The new readout system for the multi-anode PMTs in the central part of the photon detector of the RICH is based on the high-sensitivity MAD4 preamplifier-discriminator and the dead-time free F1-TDC chip characterized by high-resolution. The readout electro… ▽ More

    Submitted 14 December, 2007; v1 submitted 12 December, 2007; originally announced December 2007.

    Comments: Proceeding of RICH2007 Conference, Trieste, Oct. 2007. v2: minor changes

    Journal ref: Nucl.Instrum.Meth.A595:204-207,2008

  7. Fast photon detection for the COMPASS RICH detector

    Authors: C. Schill

    Abstract: The COMPASS experiment at the SPS accelerator at CERN uses a large scale Ring Imaging CHerenkov detector (RICH) to identify pions, kaons and protons in a wide momentum range. For the data taking in 2006, the COMPASS RICH has been upgraded in the central photon detection area (25% of the surface) with a new technology to detect Cherenkov photons at very high count rates of several 10^6 per second… ▽ More

    Submitted 14 November, 2006; originally announced November 2006.

    Comments: Proceeding of the IPRD06 conference (Siena, Okt. 06)

    Journal ref: Nucl.Phys.Proc.Suppl.172:75-78,2007

  8. arXiv:physics/0504015  [pdf

    physics.bio-ph q-bio.CB

    Measurement of the cell membrane capacitance and conductance of colonic crypt cells of the rat using the patch clamp technique

    Authors: C. Schill

    Abstract: Using the patch clamp technique the membrane capacitance and membrane conductance of colonic crypt cells of the rat was measured. The influence of the intracellular agonists Ca++, cAMP and of osmotic changes on the membrane capacitance and conductance was studied.

    Submitted 2 April, 2005; originally announced April 2005.

    Comments: Diploma thesis, University of Freiburg, Germany (in German)

  9. The Longitudinal Polarimeter at HERA

    Authors: M. Beckmann, A. Borissov, S. Brauksiepe, F. Burkart, H. Fischer, J. Franz, F. H. Heinsius, K. Konigsmann, W. Lorenzon, F. M. Menden, A. Most, S. Rudnitsky, C. Schill, J. Seibert, A. Simon

    Abstract: The design, construction and operation of a Compton back-scattering laser polarimeter at the HERA storage ring at DESY are described. The device measures the longitudinal polarization of the electron beam between the spin rotators at the HERMES experiment with a fractional systematic uncertainty of 1.6%. A measurement of the beam polarization to an absolute statistical precision of 0.01 requires… ▽ More

    Submitted 13 September, 2000; originally announced September 2000.

    Comments: 21 pages (Latex), 14 figures (EPS)

    Report number: DESY 00-106

    Journal ref: Nucl.Instrum.Meth.A479:334-348,2002