-
MPGD-based photon detectors for the upgrade of COMPASS RICH-1 and beyond
Authors:
J. Agarwala,
M. Alexeev,
C. D. R. Azevedo,
F. Bradamante,
A. Bressan,
M. Buchele,
C. Chatterjee,
M. Chiosso,
A. Cicuttin,
P. Ciliberti,
M. L. Crespo,
S. Dalla Torre,
S. Dasgupta,
O. Denisov,
M. Finger,
M. Finger Jr,
H. Fischer,
L. García Ordóñez,
M. Gregori,
G. Hamar,
F. Herrmann,
S. Levorato,
A. Martin,
G. Menon,
D. Panzieri
, et al. (7 additional authors not shown)
Abstract:
COMPASS is a fixed target experiment at CERN SPS aimed to study hadron structure and spectroscopy. Hadron identification in the momentum range between $3$ and $55 GeV/c$ is provided by a large gaseous Ring Imaging Cherenkov Counter, RICH-1. To cope with the challenges imposed by the new physics program of COMPASS, RICH-1 has been upgraded by replacing four MWPC-based photon detectors with newly de…
▽ More
COMPASS is a fixed target experiment at CERN SPS aimed to study hadron structure and spectroscopy. Hadron identification in the momentum range between $3$ and $55 GeV/c$ is provided by a large gaseous Ring Imaging Cherenkov Counter, RICH-1. To cope with the challenges imposed by the new physics program of COMPASS, RICH-1 has been upgraded by replacing four MWPC-based photon detectors with newly developed MPGD-based photon detectors. The architecture of the novel detectors is a hybrid combination of two layers of THGEMs and a Micromegas. The top of the first THGEM is coated with CsI acting as a reflective photo-cathode. The anode is segmented in pads capacitively coupled to the APV-25 based readout. The new hybrid detectors have been commissioned during the 2016 COMPASS data taking and stably operated during the 2017 run. In this paper design, construction, operation and performance aspects of the novel photon detectors for COMPASS RICH-1 are discussed.
△ Less
Submitted 18 June, 2020;
originally announced June 2020.
-
The MPGD-Based Photon Detectors for the upgrade of COMPASS RICH-1
Authors:
J. Agarwala,
M. Alexeev,
C. D. R. Azevedo,
F. Bradamante,
A. Bressan,
M. Buchele,
M. Chiosso,
C. Chatterjee,
P. Ciliberti,
S. Dalla Torre,
S. Dasgupta,
O. Denisov,
M. Finger,
M. Finger Jr,
H. Fischer,
M. Gregori,
G. Hamar,
F. Herrmann,
S. Levorato,
A. Martin,
G. Menon,
D. Panzieri,
G. Sbrizzai,
S. Schopferer,
M. Slunecka
, et al. (4 additional authors not shown)
Abstract:
After pioneering gaseous detectors of single photon for RICH applications using CsI solid state photocathodes in MWPCs within the RD26 collaboration and by the constructions for the RICH detector of the COMPASS experiment at CERN SPS, in 2016 we have upgraded COMPASS RICH by novel gaseous photon detectors based on MPGD technology. Four novel photon detectors, covering a total active area of 1.5~m…
▽ More
After pioneering gaseous detectors of single photon for RICH applications using CsI solid state photocathodes in MWPCs within the RD26 collaboration and by the constructions for the RICH detector of the COMPASS experiment at CERN SPS, in 2016 we have upgraded COMPASS RICH by novel gaseous photon detectors based on MPGD technology. Four novel photon detectors, covering a total active area of 1.5~m$^2$, have been installed in order to cope with the challenging efficiency and stability requirements of the COMPASS physics programme. They are the first application in an experiment of MPGD-based single photon detectors. All aspects of the upgrade are presented, including engineering, mass production, quality assessment and performance.
Perspectives for further developments in the field of gaseous single photon detectors are also indicated.
△ Less
Submitted 20 July, 2019;
originally announced July 2019.
-
The Hybrid MPGD-based photon detectors of COMPASS RICH-1
Authors:
J. Agarwala,
M. Alexeev,
C. D. R. Azevedo,
F. Bradamante,
A. Bressan,
M. Buechele,
C. Chatterjee,
M. Chiosso,
A. Cicuttin,
P. Ciliberti,
M. L. Crespo,
S. Dalla Torre,
S. Dasgupta,
O. Denisov,
M. Finger,
M. Finger Jr.,
H. Fischer,
M. Gregori,
G. Hamar,
F. Herrmann,
S. Levorato,
A. Martin,
G. Menon,
D. Panzieri,
G. Sbrizzai
, et al. (6 additional authors not shown)
Abstract:
Novel gaseous detectors of single photons for RICH applications have been developed and installed on COMPASS RICH-1 in 2016. They have a hybrid architecture consisting of two staggered THGEM layers (one equipped with a CsI photoconverting layer) and a bulk Micromegas; they cover a total area of 1.4 squared meters and operate stably and efficiently. They provide a single photon angular resolution o…
▽ More
Novel gaseous detectors of single photons for RICH applications have been developed and installed on COMPASS RICH-1 in 2016. They have a hybrid architecture consisting of two staggered THGEM layers (one equipped with a CsI photoconverting layer) and a bulk Micromegas; they cover a total area of 1.4 squared meters and operate stably and efficiently. They provide a single photon angular resolution of ~ 1.8 mrad and about 10 detected photons per ring at saturation. The main aspects of their construction and commissioning, their characterization and performance figures are presented.
△ Less
Submitted 17 December, 2018;
originally announced December 2018.
-
The MPGD-Based Photon Detectors for the upgrade of COMPASS RICH-1 and beyond
Authors:
J. Agarwala,
M. Alexeev,
C. D. R. Azevedo,
F. Bradamante,
A. Bressan,
M. Buchele,
M. Chiosso,
C. Chatterjee,
P. Ciliberti,
S. Dalla Torre,
S. Dasgupta,
O. Denisov,
M. Finger,
M. Finger Jr,
H. Fischer,
M. Gregori,
G. Hamar,
F. Herrmann,
S. Levorato,
A. Martin,
G. Menon,
D. Panzieri,
G. Sbrizzai,
S. Schopferer,
M. Slunecka
, et al. (4 additional authors not shown)
Abstract:
After pioneering gaseous detectors of single photon for RICH applications using CsI solid state photocathodes in MWPCs within the RD26 collaboration and by the constructions for the RICH detector of the COMPASS experiment at CERN SPS, in 2016 we have upgraded COMPASS RICH by novel gaseous photon detectors based on MPGD technology. Four novel photon detectors, covering a total active area of 1.5~m…
▽ More
After pioneering gaseous detectors of single photon for RICH applications using CsI solid state photocathodes in MWPCs within the RD26 collaboration and by the constructions for the RICH detector of the COMPASS experiment at CERN SPS, in 2016 we have upgraded COMPASS RICH by novel gaseous photon detectors based on MPGD technology. Four novel photon detectors, covering a total active area of 1.5~m$^2$, have been installed in order to cope with the challenging efficiency and stability requirements of the COMPASS physics programme. These detectors are the first application in an experiment of MPGD-based single photon detectors. All aspects of the upgrade are presented, including engineering, mass production, quality assessment and performance.
Perspectives for further developments in the field of gaseous single photon detectors are also presented.
△ Less
Submitted 2 July, 2018;
originally announced July 2018.
-
Status of COMPASS RICH-1 Upgrade with MPGD-based Photon Detectors
Authors:
M. Alexeev,
R Birsa,
F. Bradamante,
A. Bressan,
M. Chiosso,
P. Ciliberti,
S. Dalla Torre,
S. Dasgupta,
O. Denisov,
M. Finger,
M. Finger Jr,
H. Fishcher,
B. Gobbo,
M. Gregori,
G. Hamar,
F. Herrmann,
K. Koenigsmann,
S. Levorato,
A. Maggiora,
N. Makke,
A. Martin,
G. Menon,
J. Novy,
D. Panzieri,
F. A. Pereira
, et al. (10 additional authors not shown)
Abstract:
A Set of new MPGD-based Photon Detectors is being built for the upgrade of COMPASS RICH-1. The detectors cover a total active area of 1.4 m$^2$ and are based on a hybrid architecture consisting of two THGEM layers and a Micromegas. A CsI film on one THGEM acts as a reflective photocathode. The characteristics of the detector, the production of the components and their validation tests are describe…
▽ More
A Set of new MPGD-based Photon Detectors is being built for the upgrade of COMPASS RICH-1. The detectors cover a total active area of 1.4 m$^2$ and are based on a hybrid architecture consisting of two THGEM layers and a Micromegas. A CsI film on one THGEM acts as a reflective photocathode. The characteristics of the detector, the production of the components and their validation tests are described in detail.
△ Less
Submitted 25 October, 2017;
originally announced October 2017.
-
Novel MPGD based Detectors of Single Photons in COMPASS RICH-1
Authors:
J. Agarwala M. Alexeev,
C. D. R. Azevedo,
R. Birsa,
F. Bradamante,
A. Bressan,
M. Buchele,
C. Chatterjee,
M. Chiosso,
P. Ciliberti,
S. Dalla Torre,
S. Dasgupta,
O. Denisov,
M. Finger,
M. Finger Jr.,
H. Fischer,
B. Gobbo,
M. Gregori,
G. Hamar,
F. Herrmann,
S. Levorato,
A. Maggiora,
N. Makke,
A. Martin,
G. Menon,
J. Novy
, et al. (12 additional authors not shown)
Abstract:
COMPASS is a fixed target experiment at CERN SPS aimed to study Hadron Structure and Spectroscopy. Hadron Identification in the momentum range between 3 and 55 GeV/c is provided by a large gaseous Ring Imaging Cherenkov Counter (RICH-1). To cope with the challenges imposed by the new physics program of COMPASS, RICH-1 have been upgraded by replacing four MWPCs based photon detectors with newly dev…
▽ More
COMPASS is a fixed target experiment at CERN SPS aimed to study Hadron Structure and Spectroscopy. Hadron Identification in the momentum range between 3 and 55 GeV/c is provided by a large gaseous Ring Imaging Cherenkov Counter (RICH-1). To cope with the challenges imposed by the new physics program of COMPASS, RICH-1 have been upgraded by replacing four MWPCs based photon detectors with newly developed MPGD based photon detectors. The architecture of the novel detectors is a hybrid combination of two layers of THGEMs and a MicroMegas. The top of the first THGEM is coated with CsI acting as a reflective photo-cathode. The anode is segmented in pads capacitively coupled to the APV-25 based readout. The new hybrid detectors have been commissioned during 2016 COMPASS data taking and stably operated during 2017 run. In this paper all aspects of the novel photon detectors for COMPASS RICH-1 are discussed.
△ Less
Submitted 24 October, 2017;
originally announced October 2017.
-
The COMPASS Setup for Physics with Hadron Beams
Authors:
Ph. Abbon,
C. Adolph,
R. Akhunzyanov,
Yu. Alexandrov,
M. G. Alexeev,
G. D. Alexeev,
A. Amoroso,
V. Andrieux,
V. Anosov,
A. Austregesilo,
B. Badelek,
F. Balestra,
J. Barth,
G. Baum,
R. Beck,
Y. Bedfer,
A. Berlin,
J. Bernhard,
K. Bicker,
E. R. Bielert,
J. Bieling,
R. Birsa,
J. Bisplinghoff,
M. Bodlak,
M. Boer
, et al. (207 additional authors not shown)
Abstract:
The main characteristics of the COMPASS experimental setup for physics with hadron beams are described. This setup was designed to perform exclusive measurements of processes with several charged and/or neutral particles in the final state. Making use of a large part of the apparatus that was previously built for spin structure studies with a muon beam, it also features a new target system as well…
▽ More
The main characteristics of the COMPASS experimental setup for physics with hadron beams are described. This setup was designed to perform exclusive measurements of processes with several charged and/or neutral particles in the final state. Making use of a large part of the apparatus that was previously built for spin structure studies with a muon beam, it also features a new target system as well as new or upgraded detectors. The hadron setup is able to operate at the high incident hadron flux available at CERN. It is characterised by large angular and momentum coverages, large and nearly flat acceptances, and good two and three-particle mass resolutions. In 2008 and 2009 it was successfully used with positive and negative hadron beams and with liquid hydrogen and solid nuclear targets. This article describes the new and upgraded detectors and auxiliary equipment, outlines the reconstruction procedures used, and summarises the general performance of the setup.
△ Less
Submitted 7 October, 2014;
originally announced October 2014.
-
The GANDALF 128-Channel Time-to-Digital Converter
Authors:
Maximilian Büchele,
Horst Fischer,
Florian Herrmann,
Kay Königsmann,
Christian Schill,
Sebastian Schopferer
Abstract:
The GANDALF 6U-VME64x/VXS module has been designed to cope with a variety of readout tasks in high energy and nuclear physics experiments, in particular the COMPASS experiment at CERN. The exchangeable mezzanine cards allow for an employment of the system in very different applications such as analog-to-digital or time-to-digital conversions, coincidence matrix formation, fast pattern recognition…
▽ More
The GANDALF 6U-VME64x/VXS module has been designed to cope with a variety of readout tasks in high energy and nuclear physics experiments, in particular the COMPASS experiment at CERN. The exchangeable mezzanine cards allow for an employment of the system in very different applications such as analog-to-digital or time-to-digital conversions, coincidence matrix formation, fast pattern recognition or fast trigger generation. Based on this platform, we present a 128-channel TDC which is implemented in a single Xilinx Virtex-5 FPGA using a shifted clock sampling method. In this concept each input signal is continuously sampled by 16 flip-flops using equidistant phase-shifted clocks. Compared to previous FPGA designs, usually based on delay lines and comprising few TDC channels with resolutions in the order of 10 ps, our design permits the implementation of a large number of TDC channels with a resolution of 64 ps in a single FPGA. Predictable placement of logic components and uniform routing inside the FPGA fabric is a particular challenge of this design. We present measurement results for the time resolution and the nonlinearity of the TDC readout system.
△ Less
Submitted 19 December, 2011;
originally announced December 2011.
-
Development and Performance Verification of the GANDALF High-Resolution Transient Recorder System
Authors:
Stefan Bartknecht,
Horst Fischer,
Florian Herrmann,
Kay Königsmann,
Louis Lauser,
Christian Schill,
Sebastian Schopferer,
Heiner Wollny
Abstract:
With present-day detectors in high energy physics one often faces fast analog pulses of a few nanoseconds length which cover large dynamic ranges. In many experiments both amplitude and timing information have to be measured with high accuracy. Additionally, the data rate per readout channel can reach several MHz, which leads to high demands on the separation of pile-up pulses.
For an upgrade of…
▽ More
With present-day detectors in high energy physics one often faces fast analog pulses of a few nanoseconds length which cover large dynamic ranges. In many experiments both amplitude and timing information have to be measured with high accuracy. Additionally, the data rate per readout channel can reach several MHz, which leads to high demands on the separation of pile-up pulses.
For an upgrade of the COMPASS experiment at CERN we have designed the GANDALF transient recorder with a resolution of 12bit@1GS/s and an analog bandwidth of 500\:MHz. Signals are digitized with high precision and processed by fast algorithms to extract pulse arrival times and amplitudes in real-time and to generate trigger signals for the experiment. With up to 16 analog channels, deep memories and a high data rate interface, this 6U-VME64x/VXS module is not only a dead-time free digitization unit but also has huge numerical capabilities provided by the implementation of a Virtex5-SXT FPGA. Fast algorithms implemented in the FPGA may be used to disentangle possible pile-up pulses and determine timing information from sampled pulse shapes with a time resolution better than 50 ps.
△ Less
Submitted 19 December, 2011;
originally announced December 2011.
-
Implementation of mean-timing and subsequent logic functions on an FPGA
Authors:
J. Bieling,
G. Ahluwalia,
J. Barth,
F. Klein,
J. Pretz,
H. Fischer,
F. Herrmann,
C. Schill,
S. Schopferer
Abstract:
This article describes the implementation of a mean-timer and coincidence logic on a Virtex-5 FPGA for trigger purposes in a particle physics experiment. The novel feature is that the mean-timing and the coincidence logic are not synchronized with a clock which allows for a higher resolution of approximately 400 ps, not limited by a clock frequency.
This article describes the implementation of a mean-timer and coincidence logic on a Virtex-5 FPGA for trigger purposes in a particle physics experiment. The novel feature is that the mean-timing and the coincidence logic are not synchronized with a clock which allows for a higher resolution of approximately 400 ps, not limited by a clock frequency.
△ Less
Submitted 18 January, 2012; v1 submitted 22 September, 2011;
originally announced September 2011.