-
Charge Transfer Properties Through Graphene for Applications in Gaseous Detectors
Authors:
S. Franchino,
D. Gonzalez-Diaz,
R. Hall-Wilton,
R. B. Jackman,
H. Muller,
T. T. Nguyen,
R. de Oliveira,
E. Oliveri,
D. Pfeiffer,
F. Resnati,
L. Ropelewski,
J. Smith,
M. van Stenis,
C. Streli,
P. Thuiner,
R. Veenhof
Abstract:
Graphene is a single layer of carbon atoms arranged in a honeycomb lattice with remarkable mechanical and electrical properties. Regarded as the thinnest and narrowest conductive mesh, it has drastically different transmission behaviours when bombarded with electrons and ions in vacuum. This property, if confirmed in gas, may be a definitive solution for the ion back-flow problem in gaseous detect…
▽ More
Graphene is a single layer of carbon atoms arranged in a honeycomb lattice with remarkable mechanical and electrical properties. Regarded as the thinnest and narrowest conductive mesh, it has drastically different transmission behaviours when bombarded with electrons and ions in vacuum. This property, if confirmed in gas, may be a definitive solution for the ion back-flow problem in gaseous detectors. In order to ascertain this aspect, graphene layers of dimensions of about 2x2cm$^2$, grown on a copper substrate, are transferred onto a flat metal surface with holes, so that the graphene layer is freely suspended. The graphene and the support are installed into a gaseous detector equipped with a triple Gaseous Electron Multiplier (GEM), and the transparency properties to electrons and ions are studied in gas as a function of the electric fields. The techniques to produce the graphene samples are described, and we report on preliminary tests of graphene-coated GEMs.
△ Less
Submitted 16 December, 2015;
originally announced December 2015.
-
Effects of High Charge Densities in Multi-GEM Detectors
Authors:
S. Franchino,
D. Gonzalez Diaz,
R. Hall-Wilton,
H. Muller,
E. Oliveri,
D. Pfeiffer,
F. Resnati,
L. Ropelewski,
M. Van Stenis,
C. Streli,
P. Thuiner,
R. Veenhof
Abstract:
A comprehensive study, supported by systematic measurements and numerical computations, of the intrinsic limits of multi-GEM detectors when exposed to very high particle fluxes or operated at very large gains is presented. The observed variations of the gain, of the ion back-flow, and of the pulse height spectra are explained in terms of the effects of the spatial distribution of positive ions and…
▽ More
A comprehensive study, supported by systematic measurements and numerical computations, of the intrinsic limits of multi-GEM detectors when exposed to very high particle fluxes or operated at very large gains is presented. The observed variations of the gain, of the ion back-flow, and of the pulse height spectra are explained in terms of the effects of the spatial distribution of positive ions and their movement throughout the amplification structure. The intrinsic dynamic character of the processes involved imposes the use of a non-standard simulation tool for the interpretation of the measurements. Computations done with a Finite Element Analysis software reproduce the observed behaviour of the detector. The impact of this detailed description of the detector in extreme conditions is multiple: it clarifies some detector behaviours already observed, it helps in defining intrinsic limits of the GEM technology, and it suggests ways to extend them.
△ Less
Submitted 15 December, 2015;
originally announced December 2015.
-
First Measurements with New High-Resolution Gadolinium-GEM Neutron Detectors
Authors:
Dorothea Pfeiffer,
Filippo Resnati,
Jens Birch,
Maddi Etxegarai,
Richard Hall-Wilton,
Carina Höglund,
Lars Hultman,
Isabel Llamas-Jansa,
Eraldo Oliveri,
Esko Oksanen,
Linda Robinson,
Leszek Ropelewski,
Susann Schmidt,
Christina Streli,
Patrik Thuiner
Abstract:
European Spallation Source instruments like the macromolecular diffractometer, NMX, require an excellent neutron detection efficiency, high-rate capabilities, time resolution, and an unprecedented spatial resolution in the order of a few hundred micrometers over a wide angular range of the incoming neutrons. For these instruments solid converters in combination with Micro Pattern Gaseous Detectors…
▽ More
European Spallation Source instruments like the macromolecular diffractometer, NMX, require an excellent neutron detection efficiency, high-rate capabilities, time resolution, and an unprecedented spatial resolution in the order of a few hundred micrometers over a wide angular range of the incoming neutrons. For these instruments solid converters in combination with Micro Pattern Gaseous Detectors (MPGDs) are a promising option. A GEM detector with gadolinium converter was tested on a cold neutron beam at the IFE research reactor in Norway. The μTPC analysis, proven to improve the spatial resolution in the case of $^{10}$B converters, is extended to gadolinium based detectors. For the first time, a Gd-GEM was successfully operated to detect neutrons with a measured efficiency of 11.8% at a wavelength of 2 Å and a position resolution better than 250 μm.
△ Less
Submitted 2 May, 2016; v1 submitted 8 October, 2015;
originally announced October 2015.