PhysRFANet: Physics-Guided Neural Network for Real-Time Prediction of Thermal Effect During Radiofrequency Ablation Treatment
Authors:
Minwoo Shin,
Minjee Seo,
Seonaeng Cho,
Juil Park,
Joon Ho Kwon,
Deukhee Lee,
Kyungho Yoon
Abstract:
Radiofrequency ablation (RFA) is a widely used minimally invasive technique for ablating solid tumors. Achieving precise personalized treatment necessitates feedback information on in situ thermal effects induced by the RFA procedure. While computer simulation facilitates the prediction of electrical and thermal phenomena associated with RFA, its practical implementation in clinical settings is hi…
▽ More
Radiofrequency ablation (RFA) is a widely used minimally invasive technique for ablating solid tumors. Achieving precise personalized treatment necessitates feedback information on in situ thermal effects induced by the RFA procedure. While computer simulation facilitates the prediction of electrical and thermal phenomena associated with RFA, its practical implementation in clinical settings is hindered by high computational demands. In this paper, we propose a physics-guided neural network model, named PhysRFANet, to enable real-time prediction of thermal effect during RFA treatment. The networks, designed for predicting temperature distribution and the corresponding ablation lesion, were trained using biophysical computational models that integrated electrostatics, bio-heat transfer, and cell necrosis, alongside magnetic resonance (MR) images of breast cancer patients. Validation of the computational model was performed through experiments on ex vivo bovine liver tissue. Our model demonstrated a 96% Dice score in predicting the lesion volume and an RMSE of 0.4854 for temperature distribution when tested with foreseen tumor images. Notably, even with unforeseen images, it achieved a 93% Dice score for the ablation lesion and an RMSE of 0.6783 for temperature distribution. All networks were capable of inferring results within 10 ms. The presented technique, applied to optimize the placement of the electrode for a specific target region, holds significant promise in enhancing the safety and efficacy of RFA treatments.
△ Less
Submitted 21 December, 2023;
originally announced December 2023.
-
Video Capsule Endoscopy and Ingestible Electronics: Emerging Trends in Sensors, Circuits, Materials, Telemetry, Optics, and Rapid Reading Software
Authors:
Dylan Miley,
Leonardo Bertoncello Machado,
Calvin Condo,
Albert E. Jergens,
Kyoung-Jin Yoon,
Santosh Pandey
Abstract:
Real-time monitoring of the gastrointestinal tract in a safe and comfortable manner is valuable for the diagnosis and therapy of many diseases. Within this realm, our review captures the trends in ingestible capsule systems with a focus on hardware and software technologies used for capsule endoscopy and remote patient monitoring. We introduce the structure and functions of the gastrointestinal tr…
▽ More
Real-time monitoring of the gastrointestinal tract in a safe and comfortable manner is valuable for the diagnosis and therapy of many diseases. Within this realm, our review captures the trends in ingestible capsule systems with a focus on hardware and software technologies used for capsule endoscopy and remote patient monitoring. We introduce the structure and functions of the gastrointestinal tract, and the FDA guidelines for ingestible wireless telemetric medical devices. We survey the advanced features incorporated in ingestible capsule systems, such as microrobotics, closed-loop feedback, physiological sensing, nerve stimulation, sampling and delivery, panoramic imaging with adaptive frame rates, and rapid reading software. Examples of experimental and commercialized capsule systems are presented with descriptions of their sensors, devices, and circuits for gastrointestinal health monitoring. We also show the recent research in biocompatible materials and batteries, edible electronics, and alternative energy sources for ingestible capsule systems. The results from clinical studies are discussed for the assessment of key performance indicators related to the safety and effectiveness of ingestible capsule procedures. Lastly, the present challenges and outlook are summarized with respect to the risks to health, clinical testing and approval process, and technology adoption by patients and clinicians.
△ Less
Submitted 23 May, 2022;
originally announced May 2022.
-
Probing into gas leakage characteristics of ventilated supercavity through bubbly wake measurement
Authors:
Siyao Shao,
Jiaqi Li,
Kyungduck Yoon,
Jiarong Hong
Abstract:
The stability of ventilated supercavitation is strongly influenced by gas leakage characteristics of the cavity. Here we conduct a systematic investigation of such characteristics under different closure conditions including re-entrant jet (RJ), quad vortex (QV), twin vortex (TV), and pulsating twin vortex (PTV). Using high-speed digital inline holography (DIH), all the individual bubbles shed fro…
▽ More
The stability of ventilated supercavitation is strongly influenced by gas leakage characteristics of the cavity. Here we conduct a systematic investigation of such characteristics under different closure conditions including re-entrant jet (RJ), quad vortex (QV), twin vortex (TV), and pulsating twin vortex (PTV). Using high-speed digital inline holography (DIH), all the individual bubbles shed from the cavity are imaged downstream and are used to quantify the instantaneous gas leakage from the cavity. In general, the supercavity gas leakage exhibits significant fluctuations under all closure types with the instantaneous leakage rate spiking up to 20 times of the ventilation input under RJ and QV closures. However, the magnitude and occurrence rate of such excessive gas leakage vary substantially across different closures, tunnel speeds, and ventilation conditions. Particularly, as the supercavity transitions from RJ, to QV, TV, and PTV with increasing ventilation or decreasing tunnel speed, the relative excessive gas leakage decreases sharply from RJ to QV, plateaus from QV to TV, and drops again from TV to PTV. Correspondingly, the occurrence frequency of such excessive leakage first exhibits a double peak distribution under RJ, migrates to a single peak mode under QV and TV, and eventually transitions to a distribution with a broadened peak at a higher frequency under PTV. These trends can be explained by the flow instabilities associated with three distinct gas leakage mechanisms. Subsequently, two metrics are introduced to quantify the relative change of ventilation needed to compensate for the change of extra gas loss and the predictability of the occurrence of excessive gas leakage, respectively. Based on these metrics, we suggest that the supercavity operating under TV closure with moderate ventilation is optimal for ventilation-based controls of supercavity stability.
△ Less
Submitted 12 October, 2021;
originally announced October 2021.
-
Insights into ventilation hysteresis shift due to flow unsteadiness in ventilated supercavitation
Authors:
Kyungduck Yoon,
Jiaqi Li,
Siyao Shao,
Ashish Karn,
Jiarong Hong
Abstract:
Understanding ventilation strategy of a supercavity is important for designing high-speed underwater vehicles wherein an artificial gas pocket is created behind a flow separation device for drag reduction. Our study investigates the effect of flow unsteadiness on the ventilation requirements to form (CQf) and collapse (CQc) a supercavity. Imposing flow unsteadiness on the incoming flow has shown a…
▽ More
Understanding ventilation strategy of a supercavity is important for designing high-speed underwater vehicles wherein an artificial gas pocket is created behind a flow separation device for drag reduction. Our study investigates the effect of flow unsteadiness on the ventilation requirements to form (CQf) and collapse (CQc) a supercavity. Imposing flow unsteadiness on the incoming flow has shown an increment in higher CQf at low free stream velocity and lower CQf at high free stream velocity. High-speed imaging reveals distinctly different behaviors in the recirculation region for low and high freestream velocity under unsteady flows. At low free stream velocities, the recirculation region formed downstream of a cavitator shifted vertically with flow unsteadiness, resulting in lower bubble collision and coalescence probability, which is critical for the supercavity formation process. The recirculation region negligibly changed with flow unsteadiness at high free stream velocity and less ventilation is required to form a supercavity compared to that of the steady incoming flow. Such a difference is attributed to the increased transverse Reynolds stress that aids bubble collision in a confined space of the recirculation region. CQc is found to heavily rely on the vertical component of the flow unsteadiness and the free stream velocity. Interfacial instability located upper rear of the supercavity develops noticeably with flow unsteadiness and additional bubbles formed by the distorted interface shed from the supercavity, resulting in an increased CQc. Further analysis on the quantification of such additional bubble leakage rate indicates that the development and amplitude of the interfacial instability accounts for the variation of CQc under a wide range of flow unsteadiness. Our study provides some insights on the design of a ventilation strategy for supercavitating vehicles in practice.
△ Less
Submitted 2 February, 2021;
originally announced February 2021.
-
Receiver development for BICEP Array, a next-generation CMB polarimeter at the South Pole
Authors:
L. Moncelsi,
P. A. R. Ade,
Z. Ahmed,
M. Amiri,
D. Barkats,
R. Basu Thakur,
C. A. Bischoff,
J. J. Bock,
V. Buza,
J. Cheshire,
J. Connors,
J. Cornelison,
M. Crumrine,
A. Cukierman,
E. V. Denison,
M. Dierickx,
L. Duband,
M. Eiben,
S. Fatigoni,
J. P. Filippini,
N. Goeckner-Wald,
D. C. Goldfinger,
J. Grayson,
P. Grimes,
G. Hall
, et al. (50 additional authors not shown)
Abstract:
A detection of curl-type ($B$-mode) polarization of the primary CMB would be direct evidence for the inflationary paradigm of the origin of the Universe. The BICEP/Keck Array (BK) program targets the degree angular scales, where the power from primordial $B$-mode polarization is expected to peak, with ever-increasing sensitivity and has published the most stringent constraints on inflation to date…
▽ More
A detection of curl-type ($B$-mode) polarization of the primary CMB would be direct evidence for the inflationary paradigm of the origin of the Universe. The BICEP/Keck Array (BK) program targets the degree angular scales, where the power from primordial $B$-mode polarization is expected to peak, with ever-increasing sensitivity and has published the most stringent constraints on inflation to date. BICEP Array (BA) is the Stage-3 instrument of the BK program and will comprise four BICEP3-class receivers observing at 30/40, 95, 150 and 220/270 GHz with a combined 32,000+ detectors; such wide frequency coverage is necessary for control of the Galactic foregrounds, which also produce degree-scale $B$-mode signal. The 30/40 GHz receiver is designed to constrain the synchrotron foreground and has begun observing at the South Pole in early 2020. By the end of a 3-year observing campaign, the full BICEP Array instrument is projected to reach $σ_r$ between 0.002 and 0.004, depending on foreground complexity and degree of removal of $B$-modes due to gravitational lensing (delensing). This paper presents an overview of the design, measured on-sky performance and calibration of the first BA receiver. We also give a preview of the added complexity in the time-domain multiplexed readout of the 7,776-detector 150 GHz receiver.
△ Less
Submitted 7 December, 2020;
originally announced December 2020.
-
Characterizing the Sensitivity of 40 GHz TES Bolometers for BICEP Array
Authors:
C. Zhang,
P. A. R. Ade,
Z. Ahmed,
M. Amiri,
D. Barkats,
R. Basu Thakur,
C. A. Bischoff,
J. J. Bock,
H. Boenish,
E. Bullock,
V. Buza,
J. Cheshire,
J. Connors,
J. Cornelison,
M. Crumrine,
A. Cukierman,
M. Dierickx,
L. Duband,
S. Fatigoni,
J. P. Filippini,
G. Hall,
M. Halpern,
S. Harrison,
S. Henderson,
S. R. Hildebrandt
, et al. (44 additional authors not shown)
Abstract:
The BICEP/Keck (BK) experiment aims to detect the imprint of primordial gravitational waves in the Cosmic Microwave Background polarization, which would be direct evidence of the inflation theory. While the tensor-to-scalar ratio has been constrained to be r_0.05 < 0.06 at 95% c.l., further improvements on this upper limit are hindered by polarized Galactic foreground emissions and removal of grav…
▽ More
The BICEP/Keck (BK) experiment aims to detect the imprint of primordial gravitational waves in the Cosmic Microwave Background polarization, which would be direct evidence of the inflation theory. While the tensor-to-scalar ratio has been constrained to be r_0.05 < 0.06 at 95% c.l., further improvements on this upper limit are hindered by polarized Galactic foreground emissions and removal of gravitational lensing polarization. The 30/40 GHz receiver of the BICEP Array (BA) will deploy at the end of 2019 and will constrain the synchrotron foreground with unprecedented accuracy within the BK sky patch. We will show the design of the 30/40 GHz detectors and test results summarizing its performance. The low optical and atmospheric loading at these frequencies requires our TES detectors to have low saturation power in order to be photon-noise dominated. To realize the low thermal conductivity required from a 250 mK base temperature, we developed new bolometer leg designs. We will present the relevant measured detector parameters: G, Tc, Rn, Psat , and spectral bands, and noise spectra. We achieved a per bolometer NEP including all noise components of 2.07E-17 W/sqrt(Hz), including an anticipated photon noise level 1.54E-17 W/sqrt(Hz).
△ Less
Submitted 12 February, 2020;
originally announced February 2020.
-
Broadband, millimeter-wave antireflection coatings for large-format, cryogenic aluminum oxide optics
Authors:
A. Nadolski,
J. D. Vieira,
J. A. Sobrin,
A. M. Kofman,
P. A. R. Ade,
Z. Ahmed,
A. J. Anderson,
J. S. Avva,
R. Basu Thakur,
A. N. Bender,
B. A. Benson,
L. Bryant,
J. E. Carlstrom,
F. W. Carter,
T. W. Cecil,
C. L. Chang,
J. R. Cheshire IV,
G. E. Chesmore,
J. F. Cliche,
A. Cukierman,
T. de Haan,
M. Dierickx,
J. Ding,
D. Dutcher,
W. Everett
, et al. (64 additional authors not shown)
Abstract:
We present two prescriptions for broadband (~77 - 252 GHz), millimeter-wave antireflection coatings for cryogenic, sintered polycrystalline aluminum oxide optics: one for large-format (700 mm diameter) planar and plano-convex elements, the other for densely packed arrays of quasi-optical elements, in our case 5 mm diameter half-spheres (called "lenslets"). The coatings comprise three layers of com…
▽ More
We present two prescriptions for broadband (~77 - 252 GHz), millimeter-wave antireflection coatings for cryogenic, sintered polycrystalline aluminum oxide optics: one for large-format (700 mm diameter) planar and plano-convex elements, the other for densely packed arrays of quasi-optical elements, in our case 5 mm diameter half-spheres (called "lenslets"). The coatings comprise three layers of commercially-available, polytetrafluoroethylene-based, dielectric sheet material. The lenslet coating is molded to fit the 150 mm diameter arrays directly while the large-diameter lenses are coated using a tiled approach. We review the fabrication processes for both prescriptions then discuss laboratory measurements of their transmittance and reflectance. In addition, we present the inferred refractive indices and loss tangents for the coating materials and the aluminum oxide substrate. We find that at 150 GHz and 300 K the large-format coating sample achieves (97 +/- 2)% transmittance and the lenslet coating sample achieves (94 +/- 3)% transmittance.
△ Less
Submitted 2 March, 2020; v1 submitted 6 December, 2019;
originally announced December 2019.
-
Internal flows of ventilated partial cavitation
Authors:
Kyungduck Yoon,
Shijie Qin,
Siyao Shao,
Jiarong Hong
Abstract:
Our study provides the first experimental investigation of the internal flows of ventilated partial cavitation (VPC) formed by air injection behind a backward-facing step. The experiments are conducted using flow visualization and planar particle image velocimetry (PIV) with fog particles for two different cavity regimes of VPC, i.e., open cavity (OC) and two-branch cavity (TBC), under various ran…
▽ More
Our study provides the first experimental investigation of the internal flows of ventilated partial cavitation (VPC) formed by air injection behind a backward-facing step. The experiments are conducted using flow visualization and planar particle image velocimetry (PIV) with fog particles for two different cavity regimes of VPC, i.e., open cavity (OC) and two-branch cavity (TBC), under various range of free stream velocity (U) and ventilation rates (Q). Our experiments reveal similar flow patterns for both OC and TBC, including forward flow region near the air-water interface, reverse flow region, near-cavitator vortex, and internal flow circulation vortex. However, OC internal flow exhibits highly unsteady internal flow features, while TBC internal flow shows laminar-like flow patterns with a Kelvin-Helmholtz instability developed at the interface between forward and reverse flow regions within the cavity. Internal flow patterns and the unsteadiness of OC resemble those of turbulent flow separation past a backward-facing step (BFS flow), suggesting a strong coupling of internal flow and turbulent external recirculation region for OC. Likewise, internal flow patterns of TBC resemble those of laminar BFS flow, with the presence of unsteadiness due to the strong velocity gradient across the forward-reverse flow interface. The variation of the internal flow upon changing U or Q is further employed to explain the cavity regime transition and the corresponding change of cavity geometry. Our study suggests that ventilation control can potentially stabilize the cavity in the TBC regime by delaying its internal flow regime transition from laminar-like to highly unsteady.
△ Less
Submitted 28 November, 2019;
originally announced November 2019.
-
Performance of Al-Mn Transition-Edge Sensor Bolometers in SPT-3G
Authors:
A. J. Anderson,
P. A. R. Ade,
Z. Ahmed,
J. S. Avva,
P. S. Barry,
R. Basu Thakur,
A. N. Bender,
B. A. Benson,
L. Bryant,
K. Byrum,
J. E. Carlstrom,
F. W. Carter,
T. W. Cecil,
C. L. Chang,
H. -M. Cho,
J. F. Cliche,
A. Cukierman,
T. de Haan,
E. V. Denison,
J. Ding,
M. A. Dobbs,
D. Dutcher,
W. Everett,
K. R. Ferguson,
A. Foster
, et al. (64 additional authors not shown)
Abstract:
SPT-3G is a polarization-sensitive receiver, installed on the South Pole Telescope, that measures the anisotropy of the cosmic microwave background (CMB) from degree to arcminute scales. The receiver consists of ten 150~mm-diameter detector wafers, containing a total of 16,000 transition-edge sensor (TES) bolometers observing at 95, 150, and 220 GHz. During the 2018-2019 austral summer, one of the…
▽ More
SPT-3G is a polarization-sensitive receiver, installed on the South Pole Telescope, that measures the anisotropy of the cosmic microwave background (CMB) from degree to arcminute scales. The receiver consists of ten 150~mm-diameter detector wafers, containing a total of 16,000 transition-edge sensor (TES) bolometers observing at 95, 150, and 220 GHz. During the 2018-2019 austral summer, one of these detector wafers was replaced by a new wafer fabricated with Al-Mn TESs instead of the Ti/Au design originally deployed for SPT-3G. We present the results of in-lab characterization and on-sky performance of this Al-Mn wafer, including electrical and thermal properties, optical efficiency measurements, and noise-equivalent temperature. In addition, we discuss and account for several calibration-related systematic errors that affect measurements made using frequency-domain multiplexing readout electronics.
△ Less
Submitted 27 July, 2019;
originally announced July 2019.
-
On-sky performance of the SPT-3G frequency-domain multiplexed readout
Authors:
A. N. Bender,
A. J. Anderson,
J. S. Avva,
P. A. R. Ade,
Z. Ahmed,
P. S. Barry,
R. Basu Thakur,
B. A. Benson,
L. Bryant,
K. Byrum,
J. E. Carlstrom,
F. W. Carter,
T. W. Cecil,
C. L. Chang,
H. -M. Cho,
J. F. Cliche,
A. Cukierman,
T. de Haan,
E. V. Denison,
J. Ding,
M. A. Dobbs,
D. Dutcher,
W. Everett,
K. R. Ferguson,
A. Foster
, et al. (64 additional authors not shown)
Abstract:
Frequency-domain multiplexing (fMux) is an established technique for the readout of large arrays of transition edge sensor (TES) bolometers. Each TES in a multiplexing module has a unique AC voltage bias that is selected by a resonant filter. This scheme enables the operation and readout of multiple bolometers on a single pair of wires, reducing thermal loading onto sub-Kelvin stages. The current…
▽ More
Frequency-domain multiplexing (fMux) is an established technique for the readout of large arrays of transition edge sensor (TES) bolometers. Each TES in a multiplexing module has a unique AC voltage bias that is selected by a resonant filter. This scheme enables the operation and readout of multiple bolometers on a single pair of wires, reducing thermal loading onto sub-Kelvin stages. The current receiver on the South Pole Telescope, SPT-3G, uses a 68x fMux system to operate its large-format camera of $\sim$16,000 TES bolometers. We present here the successful implementation and performance of the SPT-3G readout as measured on-sky. Characterization of the noise reveals a median pair-differenced 1/f knee frequency of 33 mHz, indicating that low-frequency noise in the readout will not limit SPT-3G's measurements of sky power on large angular scales. Measurements also show that the median readout white noise level in each of the SPT-3G observing bands is below the expectation for photon noise, demonstrating that SPT-3G is operating in the photon-noise-dominated regime.
△ Less
Submitted 25 July, 2019;
originally announced July 2019.
-
Effect of mounting strut and cavitator shape on the ventilation demand for ventilated supercavitation
Authors:
Siyao Shao,
Arun Balakrishna,
Kyungduck Yoon,
Jiaqi Li,
Yun Liu,
Jiarong Hong
Abstract:
The present work reports behaviors regarding the formation and collapse of a ventilated supercavity while varying the cavitator shapes, including triangle, disk, and cone and varying mounting struts. Three cavitators with the same frontal area are fabricated with 3D printing and mounted on a forward facing model (FFM). The ventilation requirements to generate (C_Qf) and sustain (C_Qc) a supercavit…
▽ More
The present work reports behaviors regarding the formation and collapse of a ventilated supercavity while varying the cavitator shapes, including triangle, disk, and cone and varying mounting struts. Three cavitators with the same frontal area are fabricated with 3D printing and mounted on a forward facing model (FFM). The ventilation requirements to generate (C_Qf) and sustain (C_Qc) a supercavity are tested over a wide range of Froude number (Fr) for each cavitator and compared with backward facing model(BFM). Compared to the triangle and disk cavitators, the cone-shaped cavitator requires the least amount of air to generate a supercavity in nearly all of the tested flow regime except very high Fr. The C_Qc of disk FFM is lower than that of its BFM counterpart at small Fr and exceeds the BFM C_Qc with further increase of Fr. The cone cavitator has the smallest C_Qc among all the cavitators across the range of Fr in our experiments. Simultaneous internal pressure and cavity dimension measurements are conducted to elucidate the cavity sustenance behaviors. The cone-generated cavity yields a significantly smaller maximum diameter and a shorter half-length. Cavity geometric information and cavity pressure measurements with high-speed imaging of re-entrant jet are employed to estimate the re-entrant jet momentum under different Fr for disk and cone cavitators. The estimated re-entrant jet momentum shows reasonable match with the ventilation air momentum under C_Qc in lower Fr for both cavitator cases, with the disk cavitator case yielding significantly stronger re-entrant jet, providing support to the re-entrant jet mechanism governing on the cavity collapse. Our study sheds some light on the cavitator design and ventilation strategy for a supercavitating vehicle in practice.
△ Less
Submitted 23 October, 2019; v1 submitted 24 March, 2019;
originally announced March 2019.
-
Design and characterization of the SPT-3G receiver
Authors:
J. A. Sobrin,
P. A. R. Ade,
Z. Ahmed,
A. J. Anderson,
J. S. Avva,
R. Basu Thakur,
A. N. Bender,
B. A. Benson,
J. E. Carlstrom,
F. W. Carter,
T. W. Cecil,
C. L. Chang,
J. F. Cliche,
A. Cukierman,
T. de Haan,
J. Ding,
M. A. Dobbs,
D. Dutcher,
W. Everett,
A. Foster,
J. Gallichio,
A. Gilbert,
J. C. Groh,
S. T. Guns,
N. W. Halverson
, et al. (46 additional authors not shown)
Abstract:
The SPT-3G receiver was commissioned in early 2017 on the 10-meter South Pole Telescope (SPT) to map anisotropies in the cosmic microwave background (CMB). New optics, detector, and readout technologies have yielded a multichroic, high-resolution, low-noise camera with impressive throughput and sensitivity, offering the potential to improve our understanding of inflationary physics, astroparticle…
▽ More
The SPT-3G receiver was commissioned in early 2017 on the 10-meter South Pole Telescope (SPT) to map anisotropies in the cosmic microwave background (CMB). New optics, detector, and readout technologies have yielded a multichroic, high-resolution, low-noise camera with impressive throughput and sensitivity, offering the potential to improve our understanding of inflationary physics, astroparticle physics, and growth of structure. We highlight several key features and design principles of the new receiver, and summarize its performance to date.
△ Less
Submitted 31 August, 2018;
originally announced September 2018.
-
Broadband anti-reflective coatings for cosmic microwave background experiments
Authors:
A. Nadolski,
A. M. Kofman,
J. D. Vieira,
P. A. R. Ade,
Z. Ahmed,
A. J. Anderson,
J. S. Avva,
R. Basu Thakur,
A. N. Bender,
B. A. Benson,
J. E. Carlstrom,
F. W. Carter,
T. W. Cecil,
C. L. Chang,
J. F. Cliche,
A. Cukierman,
T. de Haan,
J. Ding,
M. A. Dobbs,
D. Dutcher,
W. Everett,
A. Foster,
J. Fu,
J. Gallicchio,
A. Gilbert
, et al. (49 additional authors not shown)
Abstract:
The desire for higher sensitivity has driven ground-based cosmic microwave background (CMB) experiments to employ ever larger focal planes, which in turn require larger reimaging optics. Practical limits to the maximum size of these optics motivates the development of quasi-optically-coupled (lenslet-coupled), multi-chroic detectors. These detectors can be sensitive across a broader bandwidth comp…
▽ More
The desire for higher sensitivity has driven ground-based cosmic microwave background (CMB) experiments to employ ever larger focal planes, which in turn require larger reimaging optics. Practical limits to the maximum size of these optics motivates the development of quasi-optically-coupled (lenslet-coupled), multi-chroic detectors. These detectors can be sensitive across a broader bandwidth compared to waveguide-coupled detectors. However, the increase in bandwidth comes at a cost: the lenses (up to $\sim$700 mm diameter) and lenslets ($\sim$5 mm diameter, hemispherical lenses on the focal plane) used in these systems are made from high-refractive-index materials (such as silicon or amorphous aluminum oxide) that reflect nearly a third of the incident radiation. In order to maximize the faint CMB signal that reaches the detectors, the lenses and lenslets must be coated with an anti-reflective (AR) material. The AR coating must maximize radiation transmission in scientifically interesting bands and be cryogenically stable. Such a coating was developed for the third generation camera, SPT-3G, of the South Pole Telescope (SPT) experiment, but the materials and techniques used in the development are general to AR coatings for mm-wave optics. The three-layer polytetrafluoroethylene-based AR coating is broadband, inexpensive, and can be manufactured with simple tools. The coating is field tested; AR coated focal plane elements were deployed in the 2016-2017 austral summer and AR coated reimaging optics were deployed in 2017-2018.
△ Less
Submitted 31 August, 2018;
originally announced September 2018.
-
Optical Characterization of the SPT-3G Focal Plane
Authors:
Zhaodi Pan,
Peter Ade,
Zeeshan Ahmed,
Anderson Adam,
Jason Austermann,
Jessica Avva,
Ritoban Basu Thakur,
Bender Amy,
Bradford Benson,
John Carlstrom,
Faustin Carter,
Thomas Cecil,
Clarence Chang,
Jean-Francois Cliche,
Ariel Cukierman,
Edward Denison,
Tijmen de Haan,
Junjia Ding,
Matt Dobbs,
Daniel Dutcher,
Wendeline Everett,
Allen Foster,
Renae Gannon,
Adam Gilbert,
John Groh
, et al. (51 additional authors not shown)
Abstract:
The third-generation South Pole Telescope camera is designed to measure the cosmic microwave background across three frequency bands (95, 150 and 220 GHz) with ~16,000 transition-edge sensor (TES) bolometers. Each multichroic pixel on a detector wafer has a broadband sinuous antenna that couples power to six TESs, one for each of the three observing bands and both polarization directions, via lump…
▽ More
The third-generation South Pole Telescope camera is designed to measure the cosmic microwave background across three frequency bands (95, 150 and 220 GHz) with ~16,000 transition-edge sensor (TES) bolometers. Each multichroic pixel on a detector wafer has a broadband sinuous antenna that couples power to six TESs, one for each of the three observing bands and both polarization directions, via lumped element filters. Ten detector wafers populate the focal plane, which is coupled to the sky via a large-aperture optical system. Here we present the frequency band characterization with Fourier transform spectroscopy, measurements of optical time constants, beam properties, and optical and polarization efficiencies of the focal plane. The detectors have frequency bands consistent with our simulations, and have high average optical efficiency which is 86%, 77% and 66% for the 95, 150 and 220 GHz detectors. The time constants of the detectors are mostly between 0.5 ms and 5 ms. The beam is round with the correct size, and the polarization efficiency is more than 90% for most of the bolometers
△ Less
Submitted 8 May, 2018;
originally announced May 2018.
-
Controlling Gaussian and mean curvatures at microscale by sublimation and condensation of smectic liquid crystals
Authors:
Dae Seok Kim,
Yun Jeong Cha,
Mun Ho Kim,
Oleg D. Lavrentovich,
Dong Ki Yoon
Abstract:
Soft materials with layered structure such as membranes, block copolymers, and smectics exhibit intriguing morphologies with nontrivial curvatures. We report on restructuring the Gaussian and mean curvatures of smectic A films with free surface in the process of sintering, i.e. reshaping at elevated temperatures. The pattern of alternating patches of negative, zero, and positive mean curvature of…
▽ More
Soft materials with layered structure such as membranes, block copolymers, and smectics exhibit intriguing morphologies with nontrivial curvatures. We report on restructuring the Gaussian and mean curvatures of smectic A films with free surface in the process of sintering, i.e. reshaping at elevated temperatures. The pattern of alternating patches of negative, zero, and positive mean curvature of the air-smectic interface has a profound effect on the rate of sublimation. As a result of sublimation, condensation, and restructuring, initially equilibrium smectic films with negative and zero Gaussian curvature are transformed into structures with pronounced positive Gaussian curvature of layers packing, seldom seen in samples obtained by cooling from the isotropic melt. The observed relationship between the curvatures, bulk elastic behaviour, and interfacial geometries in sintering of smectic liquid crystals paves the way for new approaches to control soft morphologies at micron and submicron scales.
△ Less
Submitted 24 November, 2015;
originally announced November 2015.
-
Development of a 3-Dimensional Dosimetry System for Leksell Gamma Knife-Perfexion
Authors:
KyoungJun Yoon,
JungWon Kwak,
DoHeui Lee,
ByungChul Cho,
SangWook Lee,
SeungDo Ahn
Abstract:
The purpose of our study is to develop a new, 3-dimensional dosimetry system to verify the accuracy of dose deliveries in Leksell Gamma Knife-Perfexion TM (LGKP) (Elekta, Norcross, GA, USA). The instrument consists of a moving head phantom, an embedded thin active layer and a CCD camera system and was designed to be mounted to LGKP. As an active material concentrically located in the hemispheric h…
▽ More
The purpose of our study is to develop a new, 3-dimensional dosimetry system to verify the accuracy of dose deliveries in Leksell Gamma Knife-Perfexion TM (LGKP) (Elekta, Norcross, GA, USA). The instrument consists of a moving head phantom, an embedded thin active layer and a CCD camera system and was designed to be mounted to LGKP. As an active material concentrically located in the hemispheric head phantom, we choose Gafchromic EBT3 films and Gd2O2S;Tb phosphor sheets for dosimetric measurements. Also, to compensate the lack of backscatter, we located a 1 cm thick PMMA plate downstream of the active layer. The PMMA plate was transparent for scintillation lights to reach the CCD with 1200x1200 pixels by a 5.2 um pitch. Using this system, three hundred images by a 0.2 mm slice gap were acquired under each of three collimator setups, i.e. 4 mm, 8 mm, and 16 mm, respectively. The 2D projected images taken by CCD camera were compared with the dose distributions measured by EBT3 films in the same conditions. All 2D distributions were normalized by the maximum values derived by fitting peaks for each collimator setup. The FWHM differences of 2D profiles between of CCD images and of film doses were measured to be less than 0.3 mm. The scanning task for whole peak regions took less than three minutes with the new instrument. It could be utilized as a QA tool for the Gamma Knife radiosurgery system instead of film dosimetry, the use of which requires much more time and resources.
△ Less
Submitted 11 March, 2015;
originally announced March 2015.
-
A Study of Al-Mn Transition Edge Sensor Engineering for Stability
Authors:
E. M. George,
J. E. Austermann,
J. A. Beall,
D. Becker,
B. A. Benson,
L. E. Bleem,
J. E. Carlstrom,
C. L. Chang,
H- M. Cho,
A. T. Crites,
M. A. Dobbs,
W. Everett,
N. W. Halverson,
J. W. Henning,
G. C. Hilton,
W. L. Holzapfel,
J. Hubmayr,
K. D. Irwin,
D. Li,
M. Lueker,
J. J. McMahon,
J. Mehl,
J. Montgomery,
T. Natoli,
J. P. Nibarger
, et al. (10 additional authors not shown)
Abstract:
The stability of Al-Mn transition edge sensor (TES) bolometers is studied as we vary the engineered TES transition, heat capacity, and/or coupling between the heat capacity and TES. We present thermal structure measurements of each of the 39 designs tested. The data is accurately fit by a two-body bolometer model, which allows us to extract the basic TES parameters that affect device stability. We…
▽ More
The stability of Al-Mn transition edge sensor (TES) bolometers is studied as we vary the engineered TES transition, heat capacity, and/or coupling between the heat capacity and TES. We present thermal structure measurements of each of the 39 designs tested. The data is accurately fit by a two-body bolometer model, which allows us to extract the basic TES parameters that affect device stability. We conclude that parameters affecting device stability can be engineered for optimal device operation, and present the model parameters extracted for the different TES designs.
△ Less
Submitted 10 November, 2013;
originally announced November 2013.