Internal-Coordinate Density Modelling of Protein Structure: Covariance Matters
Authors:
Marloes Arts,
Jes Frellsen,
Wouter Boomsma
Abstract:
After the recent ground-breaking advances in protein structure prediction, one of the remaining challenges in protein machine learning is to reliably predict distributions of structural states. Parametric models of fluctuations are difficult to fit due to complex covariance structures between degrees of freedom in the protein chain, often causing models to either violate local or global structural…
▽ More
After the recent ground-breaking advances in protein structure prediction, one of the remaining challenges in protein machine learning is to reliably predict distributions of structural states. Parametric models of fluctuations are difficult to fit due to complex covariance structures between degrees of freedom in the protein chain, often causing models to either violate local or global structural constraints. In this paper, we present a new strategy for modelling protein densities in internal coordinates, which uses constraints in 3D space to induce covariance structure between the internal degrees of freedom. We illustrate the potential of the procedure by constructing a variational autoencoder with full covariance output induced by the constraints implied by the conditional mean in 3D, and demonstrate that our approach makes it possible to scale density models of internal coordinates to full protein backbones in two settings: 1) a unimodal setting for proteins exhibiting small fluctuations and limited amounts of available data, and 2) a multimodal setting for larger conformational changes in a high data regime.
△ Less
Submitted 24 January, 2024; v1 submitted 27 February, 2023;
originally announced February 2023.
-
Systolic blood pressure estimation using ECG and PPG in patients undergoing surgery
Authors:
Shaoxiong Sun,
Erik Bresch,
Jens Muehlsteff,
Lars Schmitt,
Xi Long,
Rick Bezemer,
Igor Paulussen,
Gerrit J. Noordergraaf,
Ronald M. Aarts
Abstract:
Background and Objectives: In a significant portion of surgeries, blood pressure (BP) is often measured non-invasively in an intermittent manner. This practice has a risk of missing clinically relevant BP changes between two adjacent intermittent BP measurements. This study proposes a method to non-invasively estimate systolic blood pressure (SBP) with high accuracy in patients undergoing surgery.…
▽ More
Background and Objectives: In a significant portion of surgeries, blood pressure (BP) is often measured non-invasively in an intermittent manner. This practice has a risk of missing clinically relevant BP changes between two adjacent intermittent BP measurements. This study proposes a method to non-invasively estimate systolic blood pressure (SBP) with high accuracy in patients undergoing surgery. Methods: Continuous arterial BP, electrocardiography (ECG), and photoplethysmography (PPG) signals were acquired from 29 patients undergoing surgery. After extracting 9 features from the PPG and ECG signals, we dynamically selected features upon each intermittent measurement (every 10 min) of SBP based on feature robustness and the principle of correlation-based feature selection. Finally, multiple linear regression models were built to combine these features to estimate SBP every 30 s. Results: Compared to the reference SBP, the proposed method achieved a mean of difference at 0.08 mmHg, a standard deviation of difference at 7.97 mmHg, and a correlation coefficient at 0.89 (p < 0.001). Conclusions: This study demonstrates the feasibility of non-invasively estimating SBP every 30 s with high accuracy during surgery by using ECG, PPG, and intermittent SBP measurements every 10 min, which meets the standard of the Association for the Advancement of Medical Instrumentation. The proposed method has the potential to enhance BP monitoring in the operating room, improving patient outcomes and experiences.
△ Less
Submitted 19 August, 2022; v1 submitted 23 December, 2021;
originally announced December 2021.
-
Characterizing and Detecting Freezing of Gait using Multi-modal Physiological Signals
Authors:
Ying Wang,
Floris Beuving,
Jorik Nonnekes,
Mike X Cohen,
Xi Long,
Ronald M Aarts,
Richard Van Wezel
Abstract:
Freezing-of-gait a mysterious symptom of Parkinsons disease and defined as a sudden loss of ability to move forward. Common treatments of freezing episodes are currently of moderate efficacy and can likely be improved through a reliable freezing evaluation. Basic-science studies about the characterization of freezing episodes and a 24/7 evidence-support freezing detection system can contribute to…
▽ More
Freezing-of-gait a mysterious symptom of Parkinsons disease and defined as a sudden loss of ability to move forward. Common treatments of freezing episodes are currently of moderate efficacy and can likely be improved through a reliable freezing evaluation. Basic-science studies about the characterization of freezing episodes and a 24/7 evidence-support freezing detection system can contribute to the reliability of the evaluation in daily life. In this study, we analyzed multi-modal features from brain, eye, heart, motion, and gait activity from 15 participants with idiopathic Parkinsons disease and 551 freezing episodes induced by turning in place. Statistical analysis was first applied on 248 of the 551 to determine which multi-modal features were associated with freezing episodes. Features significantly associated with freezing episodes were ranked and used for the freezing detection. We found that eye-stabilization speed during turning and lower-body trembling measure significantly associated with freezing episodes and used for freezing detection. Using a leave-one-subject-out cross-validation, we obtained a sensitivity of 97%+/-3%, a specificity of 96%+/-7%, a precision of 73%+/-21%, a Matthews correlation coefficient of 0.82+/-0.15, and an area under the Precision-Recall curve of 0.94+/-0.05. According to the Precision-Recall curves, the proposed freezing detection method using the multi-modal features performed better than using single-modal features.
△ Less
Submitted 26 September, 2020;
originally announced September 2020.
-
LSTM knowledge transfer for HRV-based sleep staging
Authors:
Mustafa Radha,
Pedro Fonseca,
Marco Ross,
Andreas Cerny,
Peter Anderer,
Ronald M. Aarts
Abstract:
Automated sleep stage classification using heart-rate variability is an active field of research. In this work limitations of the current state-of-the-art are addressed through the use of deep learning techniques and their efficacy is demonstrated. First, a temporal model is proposed for the inference of sleep stages from electrocardiography using a deep long- and short-term (LSTM) classifier and…
▽ More
Automated sleep stage classification using heart-rate variability is an active field of research. In this work limitations of the current state-of-the-art are addressed through the use of deep learning techniques and their efficacy is demonstrated. First, a temporal model is proposed for the inference of sleep stages from electrocardiography using a deep long- and short-term (LSTM) classifier and it is shown that this model outperforms previous approaches which were often limited to non-temporal or Markovian classifiers on a comprehensive benchmark data set (292 participants, 541214 samples) comprising a wide range of ages and pathological profiles, achieving a Cohen's $κ$ of $0.61\pm0.16$ and accuracy of $76.30\pm10.17$ annotated according to the Rechtschaffen & Kales annotation standard.
Subsequently, it is demonstrated how knowledge learned on this large benchmark data set can be re-used through transfer learning for the classification of photoplethysmography (PPG) data. This is done using a smaller data set (60 participants, 91479 samples) that is annotated with the more recent American Association of Sleep Medicine annotation standard, achieving a Cohen's $κ$ of $0.63\pm0.13$ and accuracy of $74.65\pm8.63$ for wrist-mounted PPG-based sleep stage classification, higher than any previously reported performance using this sensor modality. This demonstrates the feasibility of knowledge transfer in sleep staging to adapt models for new sensor modalities as well as different annotation strategies.
△ Less
Submitted 12 September, 2018;
originally announced September 2018.
-
A Discontinuous Neural Network for Non-Negative Sparse Approximation
Authors:
Martijn Arts,
Marius Cordts,
Monika Gorin,
Marc Spehr,
Rudolf Mathar
Abstract:
This paper investigates a discontinuous neural network which is used as a model of the mammalian olfactory system and can more generally be applied to solve non-negative sparse approximation problems. By inherently limiting the systems integrators to having non-negative outputs, the system function becomes discontinuous since the integrators switch between being inactive and being active. It is sh…
▽ More
This paper investigates a discontinuous neural network which is used as a model of the mammalian olfactory system and can more generally be applied to solve non-negative sparse approximation problems. By inherently limiting the systems integrators to having non-negative outputs, the system function becomes discontinuous since the integrators switch between being inactive and being active. It is shown that the presented network converges to equilibrium points which are solutions to general non-negative least squares optimization problems. We specify a Caratheodory solution and prove that the network is stable, provided that the system matrix has full column-rank. Under a mild condition on the equilibrium point, we show that the network converges to its equilibrium within a finite number of switches. Two applications of the neural network are shown. Firstly, we apply the network as a model of the olfactory system and show that in principle it may be capable of performing complex sparse signal recovery tasks. Secondly, we generalize the application to include non-negative sparse approximation problems and compare the recovery performance to a classical non-negative basis pursuit denoising algorithm. We conclude that the recovery performance differs only marginally from the classical algorithm, while the neural network has the advantage that no performance critical regularization parameter has to be chosen prior to recovery.
△ Less
Submitted 21 March, 2016;
originally announced March 2016.