Abstract: Paralysis of the respiratory muscles in people with tetraplegia affects their ability to breathe and contributes to respiratory complications. Surface functional electrical stimulation (FES) of abdominal wall muscles can be used to increase tidal volume (VT ) and improve cough peak flow (CPF) in tetraplegic subjects who are able to breathe spontaneously. This study aims to evaluate the feasibility and effectiveness of a novel abdominal FES system which generates stimulation automatically, synchronised with the subjects' voluntary breathing activity. Four subjects with complete tetraplegia (C4-C6), breathing spontaneously, were recruited. The automatic stimulation system ensured that consistent stimulation was achieved. We compared…spirometry during unassisted and FES-assisted quiet breathing and coughing, and measured the effect of stimulation on end-tidal CO2 (EtCO2 ) during quiet breathing. The system dependably recognised spontaneous respiratory effort, stimulating appropriately, and was well tolerated by patients. Significant increases in VT during quiet breathing (range 0.05–0.23 L) and in CPF (range 0.04–0.49 L/s) were observed. Respiratory rate during quiet breathing decreased in all subjects when stimulated, whereas minute ventilation increased by 1.05–2.07 L/min. The changes in EtCO2 were inconclusive. The automatic stimulation system augmented spontaneous breathing and coughing in tetraplegic patients and may provide a potential means of respiratory support for tetraplegic patients with reduced respiratory capacity.
Show more
Keywords: Tetraplegia, pulmonary function, electrical stimulation, automatic control system
Abstract: Tetraplegic volunteers undertook progressive exercise training, using novel systems for arm-cranking exercise assisted by Functional Electrical Stimulation (FES). The main aim was to determine potential training effects of FES-assisted arm-crank ergometry (FES-ACE) on upper limb strength and cardiopulmonary {fitness} in tetraplegia. Surface FES was applied to the biceps and triceps during exercise on an instrumented ergometer. Two tetraplegic volunteers with C6 Spinal Cord Injury (SCI) went through muscle strengthening, baseline exercise testing and three months of progressive FES-ACE training. Repeat exercise tests were carried out every four weeks during training, and post-training, to monitor upper-limb strength and cardiopulmonary fitness. At…each test point, an incremental test was carried out to determine peak work rate, peak oxygen uptake, gas exchange threshold and oxygen uptake-work rate relationship during FES-ACE. Peak oxygen uptake for Subject A increased from 0.7 l/min to 1.1 l/min, and peak power output increased from 7 W to 38 W after FES-ACE training. For Subject B, peak oxygen uptake was unchanged, but peak power output increased from 3 W to 8 W. These case studies illustrate potential benefits of FES-ACE in tetraplegia, but also the differences in exercise responses between individuals.
Show more