Adaptive and fault tolerant medical vest for life-critical medical monitoring

Published: 13 March 2005 Publication History

Abstract

In recent years, exciting technological advances have been made in development of flexible electronics. These technologies offer the opportunity to weave computation, communication and storage into the fabric of the every clothing that we wear, therefore, creating intelligent fabric. This paper presents a medical vest which has sensors for physiological readings and software-controlled, electrically-actuated trans-dermal drug delivery elements. Furthermore, computational elements are embedded in the vest for collecting data from sensors, processing them and driving actuation elements. Since this vest will be used for medical, life-critical applications, the single most critical requirement of such a vest is an extremely high level of robustness and fault tolerance. Meantime, the key technological constraint for these mobile systems is their power consumption. Our target application for our medical vest is the detection of possibly fatal heart problems, specifically unstable angina pectoris or ischemia. We illustrate the design stages of our medical vest as well as the technical details of both software and network reconfiguration schemes (to enhance the robustness and the performance of our system). We also discuss the details of ischemia detection algorithm employed in our vest. Moreover, we evaluate the robustness of our system with existence of various faults. Finally we measure the performance of our algorithm as well the power consumption of several configurations of our vest.

References

[1]
Atmegal128 manual. http://www.atmel.com.
[2]
Midmark diagnostics group. http://midmarkdiagnostics.com
[3]
Physiobank - physiologic signal archives for biomedical research. http://www.physionet.org/physiobank/.
[4]
Physiotoolkit - open source software for biomedical science and engineering. http://www.physionet.org/physiotools/.
[5]
Sensatex. http://www.sensatex.com.
[6]
P. K. D. Marculescu, R. Marculescu. Challenges and opportunities in electronic textiles modeling and optimization. In Design Automation Conference, 2002. Proceedings. 39th, pages 175--180. ACM/IEEE, 2002.
[7]
L. S. S. O. G. W. J. Garcia, P. Lander and P. Laguna. Comparative study of local and karhunen-loeve-based st-t indexes in recordings from human subject with induced myocardial ischemia. Computer and Biomedical Research, 31(CO981481), 1998.
[8]
M. J. MW Zimmerman, RJ Povinelli and K. Ropella. A reconstructed phase space approach for distinguishing ischemic from non-ischemic st changes using holter ecg data. Computers in Cardiology, 30, 2003.
[9]
H. M. P. Singh. Iontophoresis in drug delivery: basic principles and applications. Crit Rev Ther Drug Carrier Syst., 11:161--213.
[10]
J. G. R. DeVaul, M. Sung and A. Pentland. Mithril 2003: applications and architecture. In Wearable Computers, Seventh IEEE International Symposium on, pages 4--11. IEEE, 2003.
[11]
L. V. S. Papadimitriou, S. Mavroudi and A. Bezerianos. Ischemia detection with a self-organizing map supplemented by supervised learning. IEEE Trans. on Neural Networks, 12(3), 2001
[12]
K. M. Sungmee Park and S. Jayaraman. The wearable motherboard: a framework for personalized mobile information processing (pmip). In Design Automation Conference, 2002. Proceedings. 39th, pages 170--174. ACM/IEEE, 2002.
[13]
J. E. R. S. T. Martin, M. Jones. Towards a design framework for wearable electronic textiles. In Wearable Computers, Seventh IEEE International Symposium on, pages 190--199. IEEE, 2003.

Cited By

View all
  • (2017)Temperature and humidity calibration of a low-cost wireless dust sensor for real-time monitoring2017 IEEE Sensors Applications Symposium (SAS)10.1109/SAS.2017.7894056(1-6)Online publication date: 2017
  • (2017)Opportunistic Environmental Sensing with Smartphones: a Critical Review of Current Literature and ApplicationsCurrent Environmental Health Reports10.1007/s40572-017-0158-84:3(306-318)Online publication date: 6-Sep-2017
  • (2016)A robust remote health monitoring and data processing system for rural area with limited internet accessProceedings of the 11th EAI International Conference on Body Area Networks10.5555/3068615.3068623(26-32)Online publication date: 15-Dec-2016
  • Show More Cited By

Index Terms

  1. Adaptive and fault tolerant medical vest for life-critical medical monitoring

      Recommendations

      Comments

      Information & Contributors

      Information

      Published In

      cover image ACM Conferences
      SAC '05: Proceedings of the 2005 ACM symposium on Applied computing
      March 2005
      1814 pages
      ISBN:1581139640
      DOI:10.1145/1066677
      Permission to make digital or hard copies of all or part of this work for personal or classroom use is granted without fee provided that copies are not made or distributed for profit or commercial advantage and that copies bear this notice and the full citation on the first page. Copyrights for components of this work owned by others than ACM must be honored. Abstracting with credit is permitted. To copy otherwise, or republish, to post on servers or to redistribute to lists, requires prior specific permission and/or a fee. Request permissions from [email protected]

      Sponsors

      Publisher

      Association for Computing Machinery

      New York, NY, United States

      Publication History

      Published: 13 March 2005

      Permissions

      Request permissions for this article.

      Check for updates

      Author Tags

      1. e-textile
      2. fault-tolerance
      3. ischemia
      4. medical vest
      5. reconfigurable fabric

      Qualifiers

      • Article

      Conference

      SAC05
      Sponsor:
      SAC05: The 2005 ACM Symposium on Applied Computing
      March 13 - 17, 2005
      New Mexico, Santa Fe

      Acceptance Rates

      Overall Acceptance Rate 1,650 of 6,669 submissions, 25%

      Contributors

      Other Metrics

      Bibliometrics & Citations

      Bibliometrics

      Article Metrics

      • Downloads (Last 12 months)7
      • Downloads (Last 6 weeks)0
      Reflects downloads up to 04 Oct 2024

      Other Metrics

      Citations

      Cited By

      View all
      • (2017)Temperature and humidity calibration of a low-cost wireless dust sensor for real-time monitoring2017 IEEE Sensors Applications Symposium (SAS)10.1109/SAS.2017.7894056(1-6)Online publication date: 2017
      • (2017)Opportunistic Environmental Sensing with Smartphones: a Critical Review of Current Literature and ApplicationsCurrent Environmental Health Reports10.1007/s40572-017-0158-84:3(306-318)Online publication date: 6-Sep-2017
      • (2016)A robust remote health monitoring and data processing system for rural area with limited internet accessProceedings of the 11th EAI International Conference on Body Area Networks10.5555/3068615.3068623(26-32)Online publication date: 15-Dec-2016
      • (2016)Flexible Wire-Component for Weaving Electronic Textiles2016 IEEE 66th Electronic Components and Technology Conference (ECTC)10.1109/ECTC.2016.180(1656-1663)Online publication date: May-2016
      • (2013)Circuits, Systems, and Technologies for Detecting the Onset of Sudden Cardiac Death Through EKG AnalysisIEEE Circuits and Systems Magazine10.1109/MCAS.2013.228396013:4(10-25)Online publication date: Dec-2014
      • (2011)Development of a body joint angle measurement system using IMU sensors2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society10.1109/IEMBS.2011.6091743(6923-6926)Online publication date: Aug-2011
      • (2010)Testing to certify an embedded software systemJournal of Computing Sciences in Colleges10.5555/1734797.173481525:4(83-90)Online publication date: 1-Apr-2010
      • (2010)Pervasive Healthcare Services and Technologies for Memory Loss Diseases SupportBiocomputation and Biomedical Informatics10.4018/978-1-60566-768-3.ch007(119-127)Online publication date: 2010
      • (2010)MediAlly: A provenance-aware remote health monitoring middleware2010 IEEE International Conference on Pervasive Computing and Communications (PerCom)10.1109/PERCOM.2010.5466985(125-134)Online publication date: Mar-2010
      • (2010)Delineating ‘Pervasiveness’ in Pervasive Information Systems: A Taxonomical Framework and Design ImplicationsJournal of Information Technology10.1057/jit.2009.625:3(273-287)Online publication date: 1-Sep-2010
      • Show More Cited By

      View Options

      Get Access

      Login options

      View options

      PDF

      View or Download as a PDF file.

      PDF

      eReader

      View online with eReader.

      eReader

      Media

      Figures

      Other

      Tables

      Share

      Share

      Share this Publication link

      Share on social media