A Method for Direct Inversion of 3D Dose Based on EPID

Published: 11 April 2022 Publication History

Abstract

Radiotherapy is one of the important methods for the clinical treatment of tumors. A large number of tumor patients need to receive radiotherapy every year. However, radiation not only kills tumor cells but also causes damage to normal tissues during the treatment. To control the additional damage and ensure the treatment effect, it is necessary to verify and calibrate the absorbed dose of the patient. This paper proposes a new 3D dose reconstruction method based on EPID data, which can verify the radiation dose more accurately and quickly.Our method uses the idea of projection reconstruction and directly deduces the corresponding dose distribution from EPID data and CT images of the phantom. Experiments show that the method in this paper has short calculation time, good reconstruction accuracy, and high practicability.

References

[1]
Low, Daniel A., "Dosimetry tools and techniques for IMRT." Medical physics 38.3 (2011): 1313-1338.
[2]
Greer, Peter B., and Carmen C. Popescu. "Dosimetric properties of an amorphous silicon electronic portal imaging device for verification of dynamic intensity modulated radiation therapy." Medical physics 30.7 (2003): 1618-1627.
[3]
Greer, Peter B. "Correction of pixel sensitivity variation and off-axis response for amorphous silicon EPID dosimetry." Medical physics 32.12 (2005): 3558-3568.
[4]
Winkler, Peter, Alfred Hefner, and Dietmar Georg. "Dose-response characteristics of an amorphous silicon EPID." Medical physics 32.10 (2005): 3095-3105.
[5]
Olaciregui-Ruiz, I., "Automatic in vivo portal dosimetry of all treatments." Physics in Medicine & Biology 58.22 (2013): 8253.
[6]
van Elmpt, Wouter, "3D in vivo dosimetry using megavoltage cone-beam CT and EPID dosimetry." International Journal of Radiation Oncology* Biology* Physics 73.5 (2009): 1580-1587.
[7]
McCowan, P. M., "An in vivo dose verification method for SBRT–VMAT delivery using the EPID." Medical physics 42.12 (2015): 6955-6963.
[8]
Gustafsson, Helen, "Direct dose to water dosimetry for pretreatment IMRT verification using a modified EPID." Medical physics 38.11 (2011): 6257-6264.
[9]
Bailey, Daniel W., "EPID dosimetry for pretreatment quality assurance with two commercial systems." Journal of applied clinical medical physics 13.4 (2012): 82-99.
[10]
Woodruff, Henry C., "Gantry-angle resolved VMAT pretreatment verification using EPID image prediction." Medical physics 40.8 (2013).
[11]
Greer, P. B. "3D EPID based dosimetry for pre-treatment verification of VMAT-methods and challenges." Journal of Physics: Conference Series. Vol. 444. No. 1. IOP Publishing, 2013.
[12]
Camilleri, Jérémy, "2D EPID dose calibration for pretreatment quality control of conformal and IMRT fields: A simple and fast convolution approach." Physica Medica 32.1 (2016): 133-140.
[13]
Slosarek, Krzysztof, "EPID in vivo dosimetry in RapidArc technique." Reports of Practical Oncology & Radiotherapy 15.1 (2010): 8-14.
[14]
van Zijtveld, Mathilda, "Portal dose image prediction for in vivo treatment verification completely based on EPID measurements." Medical physics 36.3 (2009): 946-952.
[15]
Van Uytven, Eric, "Validation of a method for in vivo 3D dose reconstruction for IMRT and VMAT treatments using on-treatment EPID images and a model-based forward-calculation algorithm." Medical physics 42.12 (2015): 6945-6954.
[16]
Najem, M. A., "In-vivo EPID dosimetry for IMRT and VMAT based on through-air predicted portal dose algorithm." Physica Medica 52 (2018): 143-153.
[17]
M. Wendling, R. J. W. Louwe, L. N. McDermott, J.-J. Sonke, M. van Herk, and B. J. Mijnheer, “Accurate two-dimensional IMRT verification using a back-projection EPID dosimetry method,” Med. Phys. 33, 259–273(2006).
[18]
M. Wendling, L. N. McDermott, A. Mans, J.-J. Sonke, M. van Herk, and B. J. Mijnheer, “A simple backprojection algorithm for 3D in vivo EPID dosimetry of IMRT treatments,” Med. Phys. 36, 3310–3321 (2009).
[19]
Pecharromán-Gallego R, Mans A, Sonke JJ, Stroom JC, Olaciregui-Ruiz I, van Herk M, Simplifying EPID dosimetry for IMRT treatment verification. Med Phys 2011;38:983-92.
[20]
Wendling, Markus, "In aqua vivo EPID dosimetry." Medical physics 39.1 (2012): 367-377.
[21]
Ren Qiang, Wang Yu, "Accurate Dose Calibration Method for an Amorphous Silicon Electronic Portal Imaging Device." Chinese Journal of Medical Physics 32.1(2015):6.
[22]
Hu Yimin. Radiation Oncology Physics. Atomic Energy Press, 1999. ISBN: 7-5022-2089-5
[23]
Liu Bote, Zheng Huaqing, "Scattered photons on inhomogeneous phantom transmission plane: an analysis based on pencil beam scatter kernels." Chinese Journal of Medical Physics 37.1(2020):6.

Recommendations

Comments

Information & Contributors

Information

Published In

cover image ACM Other conferences
ICIT '21: Proceedings of the 2021 9th International Conference on Information Technology: IoT and Smart City
December 2021
584 pages
ISBN:9781450384971
DOI:10.1145/3512576
Permission to make digital or hard copies of all or part of this work for personal or classroom use is granted without fee provided that copies are not made or distributed for profit or commercial advantage and that copies bear this notice and the full citation on the first page. Copyrights for components of this work owned by others than ACM must be honored. Abstracting with credit is permitted. To copy otherwise, or republish, to post on servers or to redistribute to lists, requires prior specific permission and/or a fee. Request permissions from [email protected]

Publisher

Association for Computing Machinery

New York, NY, United States

Publication History

Published: 11 April 2022

Permissions

Request permissions for this article.

Check for updates

Author Tags

  1. 3D dose verification
  2. EPID
  3. Radiotherapy

Qualifiers

  • Research-article
  • Research
  • Refereed limited

Funding Sources

  • The National Key R&D Program of China
  • NSAF
  • The National Key R&D Program of China

Conference

ICIT 2021
ICIT 2021: IoT and Smart City
December 22 - 25, 2021
Guangzhou, China

Contributors

Other Metrics

Bibliometrics & Citations

Bibliometrics

Article Metrics

  • 0
    Total Citations
  • 25
    Total Downloads
  • Downloads (Last 12 months)8
  • Downloads (Last 6 weeks)0
Reflects downloads up to 10 Nov 2024

Other Metrics

Citations

View Options

Get Access

Login options

View options

PDF

View or Download as a PDF file.

PDF

eReader

View online with eReader.

eReader

HTML Format

View this article in HTML Format.

HTML Format

Media

Figures

Other

Tables

Share

Share

Share this Publication link

Share on social media