Acquiring multiview C-arm images to assist cardiac ablation procedures

Published: 01 January 2010 Publication History

Abstract

CARTO XPis an electroanatomical cardiac mapping system that provides 3D color-coded maps of the electrical activity of the heart; however it is expensive and it can only use a single costly magnetic catheter for each patient intervention. Our approach consists of integrating fluoroscopic and electrical data from the RF catheters into the same image so as to better guide RF ablation, shorten the duration of this procedure, increase its efficacy, and decrease hospital cost when compared to CARTO XP. We propose a method that relies on multi-view C-arm fluoroscopy image acquisition for (1) the 3D reconstruction of the anatomical structure of interest, (2) the robust temporal tracking of the tip-electrode of a mapping catheter between the diastolic and systolic phases and (3) the 2D/3D registration of color coded isochronal maps directly on the 2D fluoroscopy image that would help the clinician guide the ablation procedure much more effectively. The method has been tested on canine experimental data.

References

[1]
E. C. Stecker, C. Vickers, J. Waltz, et al., "Population-based analysis of sudden cardiac death with and without left ventricular systolic dysfunction: two-year findings from the Oregon sudden unexpected death study," Journal of the American College of Cardiology, vol. 47, no. 6, pp. 1161-1166, 2006.
[2]
A. C. Lardo, H. Halperin, C. Yeung, P. Jumrussirikul, E. Atalar, and E. McVeigh, "Magnetic resonance guided radiofrequency ablation: creation and visualization of cardiac lesions," in Proceedings 1st International Conference on Medical Image Computing and Computer-Assisted Interventation (MICCAI '98), pp. 189-196, Cambridge, Mass, USA, October 1998.
[3]
A. C. Lardo, E. R. McVeigh, P. Jumrussirikul, et al., "Visualization and temporal/spatial characterization of cardiac radiofrequency ablation lesions using magnetic resonance imaging," Circulation, vol. 102, no. 6, pp. 698-705, 2000.
[4]
E. Chu, A. P. Fitzpatrick, M. C. Chin, K. Sudhir, P. G. Yock, and M. D. Lesh, "Radiofrequency catheter ablation guided by intracardiac echocardiography," Circulation, vol. 89, no. 3, pp. 1301-1305, 1994.
[5]
Y. Sun, S. Kadoury, Y. Li, et al., "Image guidance of intracardiac ultrasound with fusion of pre-operative images," in Proceedings of the 10th International Conference on Medical Imaging and Computer-Assisted Intervention (MICCAI '07), vol. 4791 of Lecture Notes in Computer Science, pp. 60-67, Brisbane, Australia, October-November 2007.
[6]
R. Razavi, D. L. G. Hill, S. F. Keevil, et al., "Cardiac catheterisation guided by MRI in children and adults with congenital heart disease," The Lancet, vol. 362, no. 9399, pp. 1877-1882, 2003.
[7]
R. Kato, L. Lickfett, G. Meininger, et al., "Pulmonary vein anatomy in patients undergoing catheter ablation of atrial fibrillation: lessons learned by use of magnetic resonance imaging," Circulation, vol. 107, no. 15, pp. 2004-2010, 2003.
[8]
J. M. Lacomis, W. Wigginton, C. Fuhrman, D. Schwartzman, D. R. Armfield, and K. M. Pealer, "Multi-detector row CT of the left atrium and pulmonary veins before radio-frequency catheter ablation for atrial fibrillation," Radiographics, vol. 23, pp. S35-S48, 2003.
[9]
P. Fallavollita, P. Savard, and G. Sierra, "Fluoroscopic navigation to guide RF catheter ablation of cardiac arrhythmias," in Proceedings of the 26th Annual International Conference of the IEEE Engineering in Medicine and Biology (EMBC '04), vol. 3, pp. 1929-1932, San Francisco, Calif, USA, September 2004.
[10]
E. Franken, P. Rongen, M. Van Almsick, and B. Ter Haar Romeny, "Detection of electrophysiology catheters in noisy fluoroscopy images," in Proceedings of the 9th International Conference on Medical Image Computing and Computer-Assisted Intervention (MICCAI '06), vol. 4191 of Lecture Notes in Computer Science, pp. 25-32, Copenhagen, Denmark, October 2006.
[11]
V. I. Ponomarev and A. B. Pogrebniak, "Image enhancement by homomorphic filters," in Applications of Digital Image Processing XVIII, vol. 2564 of Proceedings of SPIE, pp. 153-159, San Diego, Calif, USA, July 1995.
[12]
P. Perona and J. Malik, "Scale-space and edge detection using anisotropic diffusion," IEEE Transactions on Pattern Analysis and Machine Intelligence, vol. 12, no. 7, pp. 629-639, 1990.
[13]
T. S. Yoo, M. J. Ackerman, W. E. Lorensen, et al., "Engineering and algorithm design for an image processing Api: a technical report on ITK--the Insight Toolkit," Studies in Health Technology and Informatics, vol. 85, pp. 586-592, 2002.
[14]
Z. Zhang, "Determining the epipolar geometry and its uncertainty: a review," International Journal of Computer Vision, vol. 27, no. 2, pp. 161-195, 1998.
[15]
P. H. S. Torr and D. W. Murray, "The development and comparison of robust methods for estimating the fundamental matrix," International Journal of Computer Vision, vol. 24, no. 3, pp. 271-300, 1997.
[16]
G. Shechter, Respiratory motion of the heart: implications for magnetic resonance coronary angiography, Ph.D. dissertation, 2003.
[17]
K. Sprague, M. Drangova, G. Lehmann, et al., "Coronary x-ray angiographic reconstruction and image orientation," Medical Physics, vol. 33, no. 3, pp. 707-718, 2006.
[18]
N. Sang, W. Peng, H. Li, Z. Zhang, and T. Zhang, "3D reconstruction of the coronary tree from two X-ray angiographic views," in Medical Imaging 2006: Image Processing, vol. 6144 of Proceedings of SPIE, San Diego, Calif, USA, February 2006.
[19]
C. Blondel, G. Malandain, R. Vaillant, and N. Ayache, "Reconstruction of coronary arteries from a single rotational X-ray projection sequence," IEEE Transactions on Medical Imaging, vol. 25, no. 5, pp. 653-663, 2006.
[20]
C. B. Barber, D. P. Dobkin, and H. Huhdanpaa, "The quickhull algorithm for convex hulls," ACM Transactions on Mathematical Software, vol. 22, no. 4, pp. 469-483, 1996.
[21]
F. Duru, "CARTO three-dimensional non-fluoroscopic electroanatomic mapping for catheter ablation of arrhythmias: a useful tool or an expensive toy for the electrophysiologist?" Anadolu Kardiyoloji Dergisi, vol. 2, no. 4, pp. 330-337, 2002.
[22]
Y.-G. Li, Q.-S. Wang, G. Grönefeld, et al., "Refinement of CARTO-guided substrate modification in patients with ventricular tachycardia after myocardial infarction," Chinese Medical Journal, vol. 121, no. 2, pp. 122-127, 2008.

Recommendations

Comments

Information & Contributors

Information

Published In

cover image Journal on Image and Video Processing
Journal on Image and Video Processing  Volume 2010, Issue
Special issue on fast and robust methods for multiple-view vision
January 2010
55 pages
ISSN:1687-5176
EISSN:1687-5281
Issue’s Table of Contents

Publisher

Hindawi Limited

London, United Kingdom

Publication History

Published: 01 January 2010
Accepted: 14 December 2009
Received: 31 July 2009

Qualifiers

  • Article

Contributors

Other Metrics

Bibliometrics & Citations

Bibliometrics

Article Metrics

  • 0
    Total Citations
  • 73
    Total Downloads
  • Downloads (Last 12 months)36
  • Downloads (Last 6 weeks)8
Reflects downloads up to 01 Mar 2025

Other Metrics

Citations

View Options

View options

PDF

View or Download as a PDF file.

PDF

eReader

View online with eReader.

eReader

Login options

Figures

Tables

Media

Share

Share

Share this Publication link

Share on social media