Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
skip to main content
10.5555/1844259.1844267guideproceedingsArticle/Chapter ViewAbstractPublication PagesConference Proceedingsacm-pubtype
Article

Effects of non-ideal elements on auxiliary resonant commuted pole multi-level converter design to achieve design guideline

Published: 23 March 2010 Publication History

Abstract

A solution for high power, high voltage converter is multi-level cascade converter. In this paper a five-level cascade converter is simulated. To reduce the switching losses a soft-switching technique named auxiliary resonant commutated pole (ARCP) is utilized. The effects of non-ideal factors are analyzed and simulated and based on the simulation results the guideline for designing is introduced.

References

[1]
L. M. Tolbert and F. Z. Peng, "Multilevel converters for large electric drives," IEEE Trans. Ind. Applicat., vol. 35, no. 1, Jan./Feb. 1999, pp. 36-34.
[2]
F. Z. Peng; J. S. Lai, J. W. McKeever and J. A. VanCoevering, "Multilevel voltagesource inverter with separate DC sources for static var generation," IEEE Trans. Ind. Applicat., vol. 32, no. 5, Sept./Oct. 1996, pp. 1130-1138.
[3]
A. R. Hefner, Jr., and D. M. Diebolt, "An Experimentally Verified IGBT Model Implemented in Saber Circuit Simulator," IEEE Trans. on Power Electronics, Vol. 9, No. 5, Sept. 1994, pp. 532-542.
[4]
A. R. Hefner, Jr., "Modeling buffer layer IGBT's for Circuit Simulation," IEEE Trans. onPower Electronics, Mar. 1995, pp. 111-123.
[5]
J. -S. Lai, "Fundamentals of a New Family of Auxiliary Resonant Snubber Inverters," Conf. Rec. of IEEE IECON, Nov. 1997, pp. 645-650.
[6]
S. Pendharkar, and K. Shenai, "Zero Voltage Switching Behavior of Punch Through and Nonpunch Through Insulated Gate Bipolar Transistors (IGBT's)," IEEE Trans. On Electronic Devices, Vol. 45, No. 8, August 1998, pp. 1826-1835.
[7]
I. Widjaja, K. Kunrnia, K, Shenai, and D. M. Divan, "Switching Dynamics of IGBT's inSoft-Switching Converter," IEEE Trans. on Electronic Devices, Vol. 42, No. 3, March 1995, pp. 445-454.
[8]
A. Elasser, M. J. Schutten, V. Vlatkovic, and D. A. Torrey, "A Study of Internal Device Dynamics of Punch-Through and Non Punch-Through IGBTs under Zero-Current Switching," IEEE Trans. on Power Electronics, Vol. 12, No. 1, January 1997, pp. 21-27.
[9]
R. Siesmience, M. Netzel, and R. Herzer, "Comparison of PT and NPT Cell Concept for 600V IGBTs," Conf. Rec. of EPE'97, 1997, pp. 4.024-4.028.
  1. Effects of non-ideal elements on auxiliary resonant commuted pole multi-level converter design to achieve design guideline

      Recommendations

      Comments

      Information & Contributors

      Information

      Published In

      cover image Guide Proceedings
      AEE'10: Proceedings of the 9th WSEAS international conference on Applications of electrical engineering
      March 2010
      243 pages
      ISBN:9789604741717

      Publisher

      World Scientific and Engineering Academy and Society (WSEAS)

      Stevens Point, Wisconsin, United States

      Publication History

      Published: 23 March 2010

      Author Tags

      1. guideline of design
      2. multi-level converter
      3. soft-switching
      4. switching losses

      Qualifiers

      • Article

      Contributors

      Other Metrics

      Bibliometrics & Citations

      Bibliometrics

      Article Metrics

      • 0
        Total Citations
      • 0
        Total Downloads
      • Downloads (Last 12 months)0
      • Downloads (Last 6 weeks)0
      Reflects downloads up to 04 Feb 2025

      Other Metrics

      Citations

      View Options

      View options

      Figures

      Tables

      Media

      Share

      Share

      Share this Publication link

      Share on social media