Abstract
Raman spectroscopy reveals chemically specific information and provides label-free insight into the molecular world. However, the signals are intrinsically weak and call for enhancement techniques. Here, we demonstrate Purcell enhancement of Raman scattering in a tunable high-finesse microcavity, and utilize it for molecular diagnostics by combined Raman and absorption imaging. Studying individual single-wall carbon nanotubes, we identify crucial structural parameters such as nanotube radius, electronic structure and extinction cross-section. We observe a 320-times enhanced Raman scattering spectral density and an effective Purcell factor of 6.2, together with a collection efficiency of 60%. Potential for significantly higher enhancement, quantitative signals, inherent spectral filtering and absence of intrinsic background in cavity-vacuum stimulated Raman scattering render the technique a promising tool for molecular imaging. Furthermore, cavity-enhanced Raman transitions involving localized excitons could potentially be used for gaining quantum control over nanomechanical motion and open a route for molecular cavity optomechanics.
Similar content being viewed by others
Introduction
Raman spectroscopy is a powerful technique to identify the molecular structure of a sample. Combined with microscopy, it can provide high-resolution images with chemical contrast. This offers vast potential to investigate a broad variety of micro and nanosystems of physical, chemical and biological relevance. However, the inherently weak scattering cross-section of Raman transitions poses a challenge, and is particularly severe for spatially resolved measurements of single- or few-particle levels. Therefore, various enhancement techniques have been devised, which either rely on stimulating radiation1 or near-field enhancement2,3.
Purcell enhancement in optical microcavities4 was suggested early5,6 for its use in Raman spectroscopy. It relies on the stimulating effect of increased vacuum fluctuations within a microcavity to enhance the scattering process. It thus does not require stimulating radiation, and thereby avoids high-intensity levels at the sample, and does not introduce any intrinsic background. Detailled knowledge of the cavity mode structure allows to quantitatively evaluate the observed signal strength, which is difficult, for example, for near-field enhancement techniques. However, due to the need for microscopic mode volumes, Purcell enhancement of Raman signals has only been observed in monolithic systems with limited spatial control or spectral tunability like microdroplets5,7, photonic crystal cavities8 and FabryâPérot microcavities6,9,10,11,12,13. This has restricted the spectral coverage and impeded spatially resolved measurements so far, and only large ensembles of molecules have been studied.
Here, we present Purcell-enhanced Raman imaging using an open-access fibre-based microcavity14. This cavity platform provides small mode volume and large quality factor leading to significant Purcell enhancement, and enables spectrally and spatially resolved measurements. We demonstrate cavity-enhanced Raman imaging to study individual single-walled carbon nanotubes (CNTs), a material with widespread applications in fields as diverse as electronics15, photonics16, nanomechanics17 and quantum optics18,19. To obtain information on a CNT sampleâs heterogeneity with regards to their chirality, crystalline quality and local environment one has to characterize multiple isolated CNTs that are spatially well-separated. Raman imaging is particularly sensitive to these differences20, and combined with complementary measurements probing, for example, absorption21,22,23 can enable a detailed characterization. Notably, cavity-enhancement is at the same time present for Raman scattering, absorption and fluorescence24,25,26. Our approach thus allows to simultaneously probe the vibrational spectrum and the optical properties of a wide range of samples with enhanced sensitivity.
Results
Scanning-cavity setup
We use a high-finesse fibre-based FabryâPérot microcavity14, where the laser-machined concave end-facet of an optical fibre is used as a micro-mirror, see Fig. 1a. Altogether with a planar macroscopic mirror that carries the sample and that can be moved laterally, we realize a scanning-cavity microscope26,27,28. To record spatially resolved measurements, we raster-scan the large mirror and detect cavity signals such as the resonant cavity transmission or Purcell-enhanced Raman scattering pixel-by-pixel. The fibre mirror is mounted on a piezo actuator that allows to continuously set the cavity length to achieve suitable resonance conditions (see the âMethodsâ section). The dielectric mirror coatings lead to a finesse of up to and a quality factor depending on the cavity length d. A small radius of curvature of the concave micro-mirror on the fibre and a few-micron cavity length enables small mode volumes down to V=13λ3 (see the âMethodsâ section).
Purcell enhancement of Raman scattering
Cavity-enhanced Raman scattering can be understood analogously to fluorescence emission in a resonant cavity4,29. The spectral density of the Raman scattered light is enhanced by the (ideal) Purcell factor C0 due to increased vacuum fluctuations (proportional to Vâ1) and an increased density of states (proportional to Qc), combining to C0=(3)/(4Ï2)λ3(Qc)/(V). For our cavities with Qcâ105 and Vâ10λ3, the enhancement of the spectral density of the emission reaches values C0â103. In the regime where the cavity resonance is more narrow than a particular Raman feature, the effective Purcell factor C=(3)/(4Ï2)λ3(Qeff)/(V) is the figure of merit30, which accounts for the fact that the cavity enhances only part of the transition. This is included by replacing Qc with the effective quality factor Qeff=(Qcâ1+Qrâ1)â1 (ref. 31), where Qr is the quality factor of the Raman feature when assuming a Lorentzian spectrum. Figure 1b shows a schematic level scheme of cavity-enhanced Raman scattering and Figure 1d shows a calculation of the ideal and effective Purcell enhancement as a function of the cavity mode volume for different Qr. Typical Raman features of CNTs have Qrâ1,000â2,000 such that for a cavity with Vâλ3 one can expect Câ100. With narrower Raman lines one can approach C=C0. The cavity-enhanced Raman field is scattered entirely into the easily collected cavity mode, which, for an asymmetric choice of mirror transmissions (T2T2) and low loss (L<<T2; see the âMethodsâ section), can yield a near-unity outcoupling efficiency from the cavity ηc=T2/(T1+T2+L).
Cavity-enhanced extinction microscopy
For our experiments we transfer single-wall CNTs with an average diameter of 1.4ânm grown by chemical vapour deposition onto the planar mirror (see the âMethodsâ section). The mirror is designed to have a field maximum at the surface to ensure optimal coupling of nanotubes to the cavity mode. We study two different cavities (A and B, see the âMethodsâ section) with coatings for different wavelength ranges. In a first step, we perform scanning-cavity-extinction microscopy26 on a large area of the sample. The cavity enhances the extinction signal by a factor (cavity A), where is the cavity finesse, and thereby enables superior sensitivity for absorption microscopy. To acquire an image, we raster-scan the large mirror and tune the mirror separation over a few hundred nanometres at each pixel to sample the cavity resonance at the wavelength of maximum finesse with a narrow-band probe laser (780ânm for cavity A and 890ânm for cavity B, respectively, see the âMethodsâ section). We record the resonant cavity transmission Tc on a photodiode to infer the sample extinction B from . Here, is the mode matching between the fibre mode and the cavity mode and T1,2,L1,2 are the respective mirror transmission and loss, which are all determined independently (see the âMethodsâ section). From the sample-induced loss we deduce the extinction cross-section Ïext=BÏw02/4, where w0 is the eâ1 cavity field mode waist radius. To account for the anisotropy of the CNT extinction, we take four measurements with different orientations of linear polarization and evaluate the maximum extinction cross-section observed for each pixel. Alternatively, we use circularly polarized light (see the âMethodsâ section). Figure 2d shows a measurement with cavity A where we quantitatively image the extinction cross-section of individual CNTs with a background noise level of 5ânm2. We observe continuous elongated structures where a dominant fraction shows an extinction cross-section per length of or a corresponding cross-section per carbon atom of 3 Ã 10â4ânmâ2 when assuming a 1.4-nm tube diameter. This is consistent with individual CNTs probed away from an absorption resonance21,22 and demonstrates the potential for quantitative analysis of our technique.
Cavity-enhanced Raman spectroscopy
Significant additional information can be obtained by recording the Raman spectrum of the sample. To do so, we choose a location where absorption consistent with single CNTs is observed. We excite the cavity with a laser at a wavelength where the mirror coating is transparent (690ânm for cavity A, 786ânm for cavity B) such that light can enter the cavity independently of the mirror separation, see Fig. 1c. The Raman scattered light is red-shifted from the excitation laser to wavelengths where the cavity finesse and thus the Purcell factor is high, such that cavity-enhancement occurs (see Fig. 1b,c). This approach allows to access the range of â¼300â3,000âcmâ1, covering the important molecular fingerprint region. To record a broadband Raman spectrum, we stepwise tune the mirror separation to sweep a set of cavity resonances across the desired spectral range where Raman features are expected. The number k of resonances contributing simultaneously to probe the spectrum depends on the effective cavity length d and the considered spectral bandwidth Îν (in units of Hz) according to k=ceil[2dÎν/c]. At each spectral position of the cavity resonances we record the Purcell-enhanced scattering rate with a spectrometer and construct a full Raman spectrum by combining the maxima of all spectra. The Raman features of CNTs studied here are the G±-band related to tangential axial (+) and circumferential (â) vibrations of neighbouring carbon atoms, the defect-related D-band, and its overtone the Gâ²-band20. Figure 2a shows a high-resolution measurement of the G±-band at small mirror separation using a single longitudinal cavity mode. The measurement is combined from 370 individual spectra which are shown in Fig. 2b in a false-colour map as a function of the cavity length. With such a high sampling it is possible to achieve a spectral resolution beyond that of the spectrometer and to resolve also narrow lines, whereby the cavity-enhancement maintains the Raman lineshape. Figure 2c shows a large-bandwidth spectrum where the G± and Gâ²-bands are visible. Here, resonances with longitudinal mode numbers q=34â38 contribute due to the larger average mirror separation. For the measurement we combine 30 spectra where we change the cavity length in 10ânm steps and additionally modulate the length with a comparable amplitude at a high frequency. This provides a spectrometer-limited resolution with a reduced number of exposures. The absence of the D-band expected at 1,350âcmâ1 indicates high quality of the material. At the same time, the signal is significantly enhanced by the Purcell effect (see below).
Cavity-enhanced Raman imaging
We expand this capability to perform hyperspectral imaging. Therefore, we record cavity-enhanced Raman spectra such as the one shown in Fig. 2c at many locations on the mirror. Figure 2e,f show a measurement where the strength of the G± and Gâ²-band at 1,590âcmâ1 and 2,650âcmâ1 is visualized by selecting spectral bands of about 20âcmâ1 width, respectively. We observe excellent correspondence of the Raman map and the absorption image. The differences between the G± and Gâ² band partially originate from the spatial variation of sample extinction, which, for this measurement, affects the collected G±-band more than the Gâ²-band due to the higher finesse at the spectral position of the G± resonance. The spatial resolution of the Raman maps is found to be 2.1âμm, which is higher than for the extinction measurement where it is consistent with the cavity mode waist w0=3.2âμm. This derives from the fact that the point spread function for Raman imaging is a product of the excitation and collection point spread functions. Due to a residual low-finesse cavity at the excitation wavelength, both are given by the cavity mode, such that the resolution improves by a factor of â¼.
Hyperspectral imaging provides a maximum of information about the sample, and can permit one to chart, for example, the diameter distribution of nanotubes (see the subsection âOptimized hyperspectal imagingâ below). The improved signal from the cavity can allow to detect otherwise hidden spatial or spectral structures. The acquisition of a broadband spectrum with the cavity involves several exposures with 100â500âms integration time at each pixel. Much faster Raman imaging can be realized by scanning-cavity microscopy with a cavity stabilized on resonance with a particular Raman band. The Purcell enhancement of the signal can then provide a net advantage in acquisition time compared with conventional confocal Raman microscopy. We demonstrate this approach in the following using cavity B and a different CNT sample produced in the same way but yielding shorter tubes. We implement a digital optimization algorithm for stabilizing the cavity on resonance with the G+-band of CNTs (see the âMethodsâ section). Figure 3a shows an example where we raster-scan the mirror with a cavity length of 3.2âμm and use a dwell time of 400âms per pixel. Here, the smaller effective radius of curvature of cavity B (see the âMethodsâ section) leads to a spatial resolution of 1.5âμm. Individual nanotubes yield a signal of typically 2 à 104 countsâsâ1 for an excitation power of 14âmW, significantly larger than for a comparable confocal measurement.
Quantification of Purcell enhancement
To quantify the cavity-enhancement, we compare the cavity-based measurement of the G± band for the smallest achievable cavity length d=2.75âμm with a corresponding confocal Raman measurement taken with a microscope objective (numerical aperture 0.7) for the same position on the same isolated CNT indicated by a circle in Fig. 3a. We have chosen a location where the extension and orientation of the CNT can be resolved (see the âMethodsâ section). We set the polarization of the excitation light to be circular at the sample for both measurements to ensure comparable excitation conditions. Figure 3b shows the signal on the spectrometer for the stabilized cavity and the confocal measurement, normalized to equal excitation intensity at the location of the nanotube. We observe a strongly enhanced Raman signal at the cavity resonance, where the limited spectrometer resolution broadens the cavity line to a non-Lorentzian shape.
From several such measurements on different CNTs, and taking into account the respective collection efficiencies (see the âMethodsâ section), we extract the effective and ideal Purcell enhancement. For the effective Purcell factor we compare the confocal and cavity spectra integrated over the full G± band, yielding C=6.22.5. The error denotes the uncertainty in the determination of the respective excitation intensities and collection efficiencies. A similar statistical uncertainty is obtained when evaluating different nanotubes on the mirror and selecting for high cavity-outcoupling efficiency. The ideal Purcell factor can be obtained from the ratio of the peak spectral densities of the measurements. We extract the peak spectral density of the intrinsic cavity line, which has an independently measured linewidth of 0.15âcmâ1 at the mirror separation used (see the âMethodsâ section), by matching its integral with the integrated count rate measured with the spectrometer. This yields an ideal Purcell Factor of C0=320120. These values are in good agreement to the calculated values C=8.5 and C0=354 which were deduced from the cavity mode volume V=13λ3, the cavity quality factor Qc=6.1 à 104 and the quality factor of the Raman G+band Qr=1.54 à 103. The Raman Q-factor was obtained from a fit to the confocally collected Raman line shown in Fig. 3b. The enhancement also follows the expected scaling for Purcell enhancement when varying the cavity length and evaluating the respective integrated count rate, see Fig. 3c.
The enhanced signal is furthermore collected very efficiently. Evaluated at several different locations, we obtain collection efficiencies up to ηc=60%, comparable to the best values achievable with oil-immersion objectives. Overall, the cavity-enhancement and efficient collection provide a net signal gain, which for example can allow a speedup in Raman imaging and enable the detection of weak Raman features, which otherwise might be hidden in the background.
Optimized hyperspectral imaging
As a final step, we demonstrate the potential to study the details of spectral features while still benefiting from a net enhancement due to the cavity. We use this for efficient CNT characterization by resolving properties of the G± band, where the line splitting is related to the tube diameter, and the linewidth of the Gâ transition allows to separate metallic and semiconducting CNTs20. Figure 4a,b show examples for a semiconducting and a metallic nanotube, respectively. For the measurement we weakly stabilize the cavity to an average length where it is resonant with the G± band and modulate the mirror separation with a high-frequency triangular waveform to sweep the cavity resonance across the Raman line. This enables the acquisition of a hyperspectral image covering the G± band. Since we restrict the cavity resonance to a spectral region where a Raman signal is observed, we benefit from the average enhancement, which for the measurement shown still provides more than a factor of three average Purcell enhancement of these lines.
We fit each spectrum with a sum of two Lorentzians and evaluate their separation Î and the linewidth of the low-frequency Gâ resonance. Figure 4c shows the tube diameter inferred from20 , and Fig. 4d shows the Gâ linewidth for the same area as shown in Fig. 3a. For most of the nanotubes we obtain a clear indication of their diameter and electronic structure. This technique is particularly robust, since the cavity needs to be stabilized to a mirror separation within a few nanometres only.
Discussion
We have demonstrated cavity-enhanced Raman spectro-imaging of individual nanoobjects. The accessible spectral range covers the molecular fingerprint region, underlining the general applicability of the technique. Purcell enhancement and the cavity-intrinsic highly efficient collection of signals provide a net gain compared with confocal Raman imaging, and improve the analysis of heterogeneous samples on large areas.
Reducing mode volumes further can improve the Purcell enhancement by about one order of magnitude32, additional enhancement can be achieved by cavity-enhancement of the excitation laser by up to a factor 104 as shown earlier9, and collection efficiencies can exceed 90% by slightly optimizing the cavity mirror reflectivities. Overall, enhancement factors beyond 106 can be realized in this way. Excitation of Raman transitions via electronic resonances20 can additionally increase the signal. Furthermore, the cavity serves as a spectrally selective element without sacrificing signal, such that with suitable calibration, no spectrometer is required. This could enable, cost-effectively, a spectral resolution given by the cavity linewidth, as small as 0.01âcmâ1. The strong cavity filtering could also allow the acquisition of spectra at very low wave-numbers, for example, by exciting at a shallow angle through the mirror where the dielectric coating becomes transparent. The demonstrated combination of enhancement of Raman signals and ultra-sensitive absorption spectroscopy extends the accessible information compared with other techniques. Finally, high-finesse microcavities should enable low-threshold Raman lasers with a variety of novel materials.
Beyond Raman imaging, we believe that our approach could be used to gain optical quantum control over phonons. By harnessing strong coupling between cavity photons and localized excitons in CNTs29,33,34, Raman transitions could be used to create and detect single phonons35,36. This could lead to a hybrid cavity-optomechanical platform37, where quantum control of mechanical motion becomes accessible on a molecular scale38.
Methods
Optical setup
The setup combines a scanning-cavity and a confocal microscope, which share a closed-loop nanopositioning stage (attocube ECS 3030) that can translate the sample-carrying mirror between the cavity and the focus of an objective. This enables us to study the same location on the sample with both techniques. For cavity measurements, we couple grating-stabilized diode lasers (690ânm for Raman in cavity A and stabilization in cavity B, 786ânm for Raman in cavity B and cavity characterization in cavity A, 890ânm for cavity characterization in cavity B) into the cavity fibre and collect the cavity transmission with an aspheric lens. The cavity length can be fine tuned across â¼2âμm with a shear piezo onto which the fibre is mounted. We detect the transmitted laser light on a sensitive photodiode (Thorlabs APD120) and Raman signals on a spectrometer (Princeton Instruments Acton SP2500 with Andor ikon-M). The confocal setup contains a long working-distance objective with numerical aperture 0.7 (Mitutoyo Plan Apo NIR HR 100x) oriented with an angle of 38° to the surface normal of the mirror, which we account for in the evaluated excitation intensity and collection efficiency.
Optical microcavity
We use two different mirror coatings and fibres for experiments covering different wavelength ranges. Cavity A has a coating with a stopband centre at 780ânm with T1=12âp.p.m., T2=60âp.p.m., L1=12, L2=27âp.p.m. and a finesse . The fibre of cavity A has an effective radius of curvature rc=190âμm, leading to w0=2.7âμm for a mirror separation of d=4.5âμm as used in the experiment shown in Fig. 2d,e. There, the quality factor amounts to . Cavity B has a coating which is optimized for low background fluorescence and large outcoupling efficiency in the presence of CNT absorption. It is centred at 890ânm with T1=77âp.p.m., T2=335âp.p.m., L1=12âp.p.m., L2=20âp.p.m. and . A smaller rc=90âμm leads to w0=2.1âμm for d=3.2âμm. The edges of the tip of fibre B are mechanically polished off to allow for cavity lengths as small as d=2.75âμm, where we obtain a mode volume V=Ïw02d/4=13λ3. The finesse of both cavities is measured by probing the cavity transmission with a laser while tuning the mirror separation across more than a free spectral range, and evaluating the resonance linewidth and separation. The effective cavity length d, which includes field penetration into the coating, is deduced from the free spectral range observed in broadband cavity-transmission spectra. The mode waist w0 is measured by absorption imaging of point-like objects with the cavity.
Cavity stabilization
We use a laser at 690ânm where the mirror has high transmission to provide an error signal for stabilization of cavity B. With the additional transmission signal of the Raman excitation laser at 780ânm, we implement a digital optimization algorithm for locking the cavity on resonance with any Raman transition within the accessible spectral range. Our scheme enables locking also when slip-stick motion of the nanopositioner with significant crosstalk on the cavity length is involved. The mirror separation is stabilized to below 200âpm and therefore maintains the spectral position of the resonance within 0.31âcmâ1.
Count rate comparison
When comparing confocal and cavity-enhanced count rates, we correct for the differences in the respective excitation intensities and collection efficiencies. For the cavity, the outcoupling efficiency through the planar mirror is given by ηc=T2/(T1+T2+L1+L2+2B) and depends on the local extinction of the sample. We use a scanning-cavity extinction measurement covering the area shown in Fig. 3a to calculate ηc at the locations used for enhancement determination. The collection efficiency of the objective is calculated by integrating the interfering direct and reflected dipole radiation pattern over the opening angle of the inclined objective, and accounting for the polarization- and angle-dependent complex reflectivity of the Bragg mirror. The obtained value depends on the dipole orientation and amounts to 43% (15%) including objective transmission for orthogonal (parallel) orientation with respect to the projection of the inclined optical axis in the mirror plane. Transmission through further optics is directly measured; confocal and cavity measurements share most of the optical path including filters and coupling to the spectrometer. The excitation intensity at the nanotube in the cavity is calculated from the measured mode waist, the transmitted laser power and the measured and calculated outcoupling mirror transmission. For the objective, we measure the excitation point spread function and account for the standing wave due to the mirror. Furthermore, when evaluating signals of extended CNTs we account for a spatial overlap factor ξ with the cavity mode, entering the evaluation of C0, C and B, which are defined as peak values. The observed average values are, for example, ãCã=ξC, where for a homogeneous linear CNT larger than the mode diameter , whereas for a point-like sample ξ=1.
Sample preparation
Single-wall CNTs were synthesized on SiO2 by chemical vapour deposition following the procedure described in ref. 33. In brief, iron-ruthenium particles spin-coated on SiO2 were used to catalyse the growth of CNTs with methane as carbon feedstock. Before the CVD growth the substrate with catalyst particles was treated by oxygen plasma to yield longer CNTs. Subsequently the substrate was transferred into a standard CVD furnace, heated in an argonâhydrogen (95%/5%) atmosphere to 850â°C and kept in a flow of 1âslm methane and 0.75âslm hydrogen for 10âmin before the cool-down in an argonâhydrogen atmosphere. The average diameter of nanotubes obtained with this method was 1.4ânm. The nanotubes were transferred by contact-stamping the SiO2 chip with CVD-grown CNTs onto the mirror substrate. Scanning electron microscopy showed isolated CNTs on the cavity mirror.
Data availability
The data that support the findings of this study are available from the corresponding author on request.
Additional information
How to cite this article: Hümmer, T. et al. Cavity-enhanced Raman microscopy of individual carbon nanotubes. Nat. Commun. 7:12155 doi: 10.1038/ncomms12155 (2016).
References
Camp, C. H. Jr & Cicerone, M. T. Chemically sensitive bioimaging with coherent Raman scattering. Nat. Photon. 9, 295â305 (2015).
Le Ru, E. C., Blackie, E., Meyer, M. & Etchegoin, P. G. Surface enhanced Raman scattering enhancement factors: a comprehensive study. J. Phys. Chem. C 111, 13794â13803 (2007).
Hartschuh, A., Sánchez, E. J., Xie, X. S. & Novotny, L. High-resolution near-field Raman microscopy of single-walled carbon nanotubes. Phys. Rev. Lett. 90, 095503 (2003).
Vahala, K. J. Optical microcavities. Nature 424, 839â846 (2003).
Snow, J. B., Qian, S.-X. & Chang, R. K. Stimulated Raman scattering from individual water and ethanol droplets at morphology-dependent resonances. Opt. Lett. 10, 37â39 (1985).
Cairo, F., De Martini, F. & Murra, D. QED-vacuum confinement of inelastic quantum scattering at optical frequencies: A new perspective in Raman spectroscopy. Phys. Rev. Lett. 70, 1413â1416 (1993).
Symes, R., Sayer, R. M. & Reid, J. P. Cavity enhanced droplet spectroscopy: Principles, perspectives and prospects. Phys. Chem. Chem. Phys. 6, 474â487 (2004).
Sumikura, H., Kuramochi, E., Taniyama, H. & Notomi, M. Cavity-enhanced Raman scattering of single-walled carbon nanotubes. Appl. Phys. Lett. 102, 231110 (2013).
Petrak, B., Djeu, N. & Muller, A. Purcell-enhanced Raman scattering from atmospheric gases in a high-finesse microcavity. Phys. Rev. A 89, 023811 (2014).
Tartakovskii, A. I. et al. Raman scattering in strongly coupled organic semiconductor microcavities. Phys. Rev. B 63, 121302 (2001).
Fainstein, A., Jusserand, B. & Thierry-Mieg, V. Raman efficiency in a planar microcavity. Phys. Rev. B 53, R13287 (1996).
Checoury, X., Han, Z., El Kurdi, M. & Boucaud, P. Deterministic measurement of the Purcell factor in microcavities through Raman emission. Phys. Rev. A 81, 033832 (2010).
Fainstein, A. & Jusserand, B. Phonons in semiconductor planar microcavities: A Raman scattering study. Phys. Rev. B 54, 11505 (1996).
Hunger, D. et al. A fiber FabryâPerot cavity with high finesse. New J. Phys. 12, 065038 (2010).
Avouris, P., Chen, Z. & Perebeinos, V. Carbon-based electronics. Nat. Nanotech. 2, 605â615 (2007).
Avouris, P., Freitag, M. & Perebeinos, V. Carbon-nanotube photonics and optoelectronics. Nat. Photon. 2, 341â350 (2008).
Moser, J., Eichler, A., Güttinger, J., Dykman, M. I. & Bachtold, A. Nanotube mechanical resonators with quality factors of up to 5 million. Nat. Nanotech. 9, 1007â1011 (2014).
Högele, A., Galland, C., Winger, M. & ImamoÄlu, A. Photon antibunching in the photoluminescence spectra of a single carbon nanotube. Phys. Rev. Lett. 100, 217401 (2008).
Jeantet, A. et al. Widely tunable single-photon source from a carbon nanotube in the Purcell regime. Available at http://arxiv.org/abs/1508.06297 (2015).
Dresselhaus, M. S., Dresselhaus, G., Saito, R. & Jorio, A. Raman spectroscopy of carbon nanotubes. Phys. Rep. 409, 47â99 (2005).
Blancon, J.-C. et al. Direct measurement of the absolute absorption spectrum of individual semiconducting single-wall carbon nanotubes. Nat. Commun. 4, 2542 (2013).
Oudjedi, L., Parra-Vasquez, A. N. G., Godin, A. G., Cognet, L. & Lounis, B. Metrological investigation of the (6,5) carbon nanotube absorption cross section. J. Phys. Chem. Lett. 4, 1460â1464 (2013).
Heylman, K. D., Knapper, K. A. & Goldsmith, R. H. Photothermal microscopy of nonluminescent single particles enabled by optical microresonators. Phys. Chem. Lett. 5, 1917â1923 (2014).
Motsch, M., Zeppenfeld, M., Pinkse, P. W. H. & Rempe, G. Cavity-enhanced Rayleigh scattering. New J. Phys. 12, 063022 (2010).
Tanji-Suzuki, H. et al. Interaction between atomic ensembles and optical resonators: classical description. Vol. 60 (Elsevier Inc., 2011). Available at http://arxiv.org/abs/1104.3594.
Mader, M., Reichel, J., Hänsch, T. W. & Hunger, D. A scanning cavity microscope. Nat. Commun. 6, 7249 (2015).
Toninelli, C. et al. A scanning microcavity for in situ control of single-molecule emission. Appl. Phys. Lett. 97, 021107 (2010).
Greuter, L. et al. A small volume tunable microcavity: development and characterization. Appl. Phys. Lett. 105, 121105 (2014).
Miura, R. et al. Ultralow mode-volume photonic crystal nanobeam cavities for high-efficiency coupling to individual carbon nanotube emitters. Nat. Commun. 5, 5580 (2014).
Kaupp, H. et al. Scaling laws of the cavity enhancement for nitrogen-vacancy centers in diamond. Phys. Rev. A 88, 053812 (2013).
Auffèves, A. et al. Controlling the dynamics of a coupled atom-cavity system by pure dephasing. Phys. Rev. B 81, 245419 (2010).
Kelkar, H. et al. Sensing nanoparticles with a cantilever-based scannable optical cavity of low finesse and sub-λ3 volume. Phys. Rev. Appl. 4, 054010 (2015).
Hofmann, M. S. et al. Bright, long-lived and coherent excitons in carbon nanotube quantum dots. Nat. Nanotech. 8, 502â505 (2013).
Ma, X., Hartmann, N. F., Baldwin, J. K. S., Doorn, S. K. & Htoon, H. Room-temperature single-photon generation from solitary dopants of carbon nanotubes. Nat. Nanotech. 10, 671â675 (2015).
Wilson-Rae, I., Galland, C., Zwerger, W. & ImamoÄlu, A. Exciton-assisted optomechanics with suspended carbon nanotubes. New J. Phys. 14, 115003 (2012).
Restrepo, J., Ciuti, C. & Favero, I. Single-polariton optomechanics. Phys. Rev. Lett. 112, 013601 (2014).
Stapfner, S. et al. Cavity-enhanced optical detection of carbon nanotube brownian motion. Appl. Phys. Lett. 102, 151910 (2013).
Roelli, P., Galland, C., Piro, N. & Kippenberg, T. J. Molecular cavity optomechanics as a theory of plasmon-enhanced Raman scattering. Nat. Nanotech. 11, 164â169 (2016).
Acknowledgements
We thank Jakob Reichel and Matthias Mader for helpful discussions, Hanno Kaupp for assistance with fabricating the fibres, and Philipp Altpeter and Reinhold Rath for assistance in the clean-room. We gratefully acknowledge financial support by the European Research Council under ERC Grant Agreement no. 336749, the DFG Cluster of Excellence NIM (Nanosystems Initiative Munich), the Center for NanoScience (CeNS) and LMUInnovativ. T.W.H acknowledges funding from the Max-Planck Foundation.
Author information
Authors and Affiliations
Contributions
D.H., A.H. and T.W.H. conceived the experiment. T.H. and D.H. designed and performed the experiments. T.H., D.H and A.H. analysed the data. J.N. and M.S.H. prepared the sample. D.H., T.H. and A.H. wrote the article. All authors discussed the manuscript.
Corresponding authors
Ethics declarations
Competing interests
The authors declare no competing financial interests.
Rights and permissions
This work is licensed under a Creative Commons Attribution 4.0 International License. The images or other third party material in this article are included in the articleâs Creative Commons license, unless indicated otherwise in the credit line; if the material is not included under the Creative Commons license, users will need to obtain permission from the license holder to reproduce the material. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/
About this article
Cite this article
Hümmer, T., Noe, J., Hofmann, M. et al. Cavity-enhanced Raman microscopy of individual carbon nanotubes. Nat Commun 7, 12155 (2016). https://doi.org/10.1038/ncomms12155
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/ncomms12155
This article is cited by
-
Cavity-enhanced photon indistinguishability at room temperature and telecom wavelengths
Nature Communications (2024)
-
Near-unity Raman β-factor of surface-enhanced Raman scattering in a waveguide
Nature Nanotechnology (2022)
-
Fabricating a Raman spectrometer using an optical pickup unit and pulsed power
Scientific Reports (2020)
-
Polariton hyperspectral imaging of two-dimensional semiconductor crystals
Scientific Reports (2019)
-
Cavity-control of interlayer excitons in van der Waals heterostructures
Nature Communications (2019)