Detection and location method of distribution network grounding line based on loop impedance method

Published: 21 April 2022 Publication History

Abstract

The accuracy of the existing grounding detection system is usually relatively high in identifying the grounding point at the level of transmission network, but it is poor in identifying the grounding point at the level of distribution network. In this paper, a detecting method for locating the ground wire of the distribution network based on the loop impedance method is proposed. It is less affected by environmental factors, has a low cost, and is suitable for low-voltage distribution network detection under different operating conditions of the system. The main contents of this paper are presented as follows: First, the unit-length line impedance equation is derived. The relationship between frequency and line length is proposed, considering the influence of frequency on current detection. Second, the optimal frequency point for detecting the line current of the grounding wire is demonstrated. Then, the current threshold method considering environmental factors to determine the existence of the grounding wire is analyzed. Third, a general equation for judging the existence of the grounding wire is proposed. To locate the specific grounding, a loop impedance ranging method based on the optimal frequency point is proposed. Finally the correctness of the theoretical analysis, as well as the predictive method, is verified through the PSCAD/EMTDC.

References

[1]
A. Naresh Kumar,Ch. Sanjay,M. Chakravarthy. Adaptive neuro fuzzy inference system-based fault location technique in double circuit transmission line against simultaneous faults[J]. Multiscale and Multidisciplinary Modeling, Experiments and Design,2020,3(1).
[2]
Zhao Y, Su J, Gu S, Influence of different coupling ground wire erecting mode on lightning withstand performance for multi-circuit transmission line in a tower[C]// Lightning Protection. IEEE, 2014:1036-1040.
[3]
Shi Z, Liu L, Xiao P, Applying transmission line theory to study the transmitting turn-off current in a long grounded wire[J]. IEEE Transactions on Antennas & Propaga-tion, 2017, 65(10):5112-5122.
[4]
Y. Ma, K. Chen, Y. Ma, L. Wang and X. Cao, "Research on lightning performance of insulated ground wire in 500kV extra high voltage transmission line," 2014 International Conference on Lightning Protection (ICLP), 2014, pp. 768-771.
[5]
Hui Wang, Luyang Wang, Yufei Wang, Hua Xue, Changhui Yang and Tianyou Yan, "The electric energy loss in overhead ground wires of 110kV six-circuit transmission line on the same tower," IEEE PES Innovative Smart Grid Technologies, 2012, pp. 1-5.
[6]
L.Wu,B.W.Hou,Y.J.Zhang,et al. “Detection method of grounding state of distribution network based on loop impedance angle”, Rural water conservancy and hydropower, vol 56, no 7, pp. 149-156. 2014.
[7]
X. Li, J. Zhang, J. Song and X. Han, "Design of security management system based on RFID temporary grounding wire borrowing," 2019 IEEE 3rd Advanced Information Management, Communicates, Electronic and Automation Control Conference (IMCEC), 2019, pp. 832-836.
[8]
W. Chen and J. Liu, "Research of substation ground wire monitoring system based on WLAN," 2009 International Conference on Industrial Mechatronics and Automation, 2009, pp. 501-503.
[9]
J. Liu, J. Miao, L.Yao, “Visual detection device for grounding wire in electric power maintenance operations”, Electric Power Automation Equipment, vol.30, no.7, pp.134-138, 2010.
[10]
S.Zhu. “Detector to prevent closing with ground wire: CN91201372.9”,P, 1991.
[11]
L.Yu, X. Guo, B Han., “The principle and device realization of adaptive zero-sequence current protection for feeders in low-resistance grounding systems”. Electric Power Automation Equipment, vol.37, no.11, pp.125-131, 2017.
[12]
Q. Chen. “A remote detection and reminder system to prevent closing with ground wire”, P, 2010.
[13]
Y. Liu, J. Liu., G. Li, “Portable substation grounding status indicator”. Journal of Chongqing University of Science and Technology (Natural Science Edition), vol 11, no 5, pp:77-79.
[14]
J. Xu, W. Dou, A.Wang. “On-line monitoring system design for grounding wire status”. Electric Power Automation Equipment, vol.28,no.7,pp.111-120, 2008.
[15]
Y. Shu and Y. Tang, "Analysis and recommendations for the adaptability of China's power system security and stability relevant standards," in CSEE Journal of Power and Energy Systems, vol. 3, no. 4, pp. 334-339, Dec. 2017.
[16]
Z. Yun, X. Cui and K. Ma, "Online Thevenin Equivalent Parameter Identification Method of Large Power Grids Using LU Factorization," in IEEE Transactions on Power Systems, vol. 34, no. 6, pp. 4464-4475, Nov. 2019.
[17]
S. Kurokawa, J. P. Filho, M. C. Tavares, C. M. Portela and A. J. Prado, "Behavior of overhead transmission line parameters on the presence of ground wires," in IEEE Transactions on Power Delivery, vol. 20, no. 2, pp. 1669-1676, April 2005.
[18]
S. Agarwal, A. Swetapadma, C. Panigrahi and A. Dasgupta, "Fault detection in direct current transmission lines using discrete fourier transform from single terminal current signals," 2017 1st International Conference on Electronics, Materials Engineering and Nano-Technology (IEMENTech), 2017, pp. 1-5.
[19]
"IEEE Guide for the Parameter Measurement of AC Transmission Lines," in IEEE Std 1870-2019, vol., no., pp.1-99, 8 July 2019.
[20]
Y. He, M. Choi and Y. -B. Kim, "A Compensation Technique for Threshold Mismatch in Sub-threshold Current Mirror," 2021 IEEE Microelectronics Design & Test Symposium (MDTS), 2021, pp. 1-4.

Recommendations

Comments

Information & Contributors

Information

Published In

cover image ACM Other conferences
EEET 2021: 2021 4th International Conference on Electronics and Electrical Engineering Technology
December 2021
290 pages
ISBN:9781450385169
DOI:10.1145/3508297
Permission to make digital or hard copies of all or part of this work for personal or classroom use is granted without fee provided that copies are not made or distributed for profit or commercial advantage and that copies bear this notice and the full citation on the first page. Copyrights for components of this work owned by others than ACM must be honored. Abstracting with credit is permitted. To copy otherwise, or republish, to post on servers or to redistribute to lists, requires prior specific permission and/or a fee. Request permissions from [email protected]

Publisher

Association for Computing Machinery

New York, NY, United States

Publication History

Published: 21 April 2022

Permissions

Request permissions for this article.

Check for updates

Author Tags

  1. Grounding wire
  2. current threshold
  3. impedance ranging method
  4. loop impedance

Qualifiers

  • Research-article
  • Research
  • Refereed limited

Conference

EEET 2021

Contributors

Other Metrics

Bibliometrics & Citations

Bibliometrics

Article Metrics

  • 0
    Total Citations
  • 16
    Total Downloads
  • Downloads (Last 12 months)8
  • Downloads (Last 6 weeks)0
Reflects downloads up to 18 Aug 2024

Other Metrics

Citations

View Options

Get Access

Login options

View options

PDF

View or Download as a PDF file.

PDF

eReader

View online with eReader.

eReader

HTML Format

View this article in HTML Format.

HTML Format

Media

Figures

Other

Tables

Share

Share

Share this Publication link

Share on social media