Flexural Capacity of the Normal Sections of Concrete Beams Strengthened with Corrugated Steel Plates
Abstract
:1. Introduction
2. Test Overview
2.1. Specimen Design and Fabrication
2.2. Specimen Loading and Measurement Points
3. Test Results and Analysis
3.1. Test Phenomena
3.2. Load–Deflection Curve
3.3. Load–Strain Curve
4. Theory of Concrete Beams Strengthened with CSPs
4.1. Theory of Inertia Moment of Composite Section
- (1)
- The contact surfaces of the steel plate and concrete exhibited the same strain and deformation compatibility.
- (2)
- Before and after the transformation, the joint forces in the section acted at the same location.
- (3)
- Before and after the transformation, the centroid and inertia moments were the same.
4.2. Theory of Flexural Capacity of Normal Section
- (1)
- In this study, the analysis of the one-time stress plastic flexural capacity of concrete beams strengthened with CSPs was based on the subsequent assumptions.
- (2)
- The entire stress process in the composite structure conforms to the assumption of a flat section, as shown in Figure 11.
- (3)
- Spalling and slippage at corrugated steel and concrete material interfaces are not negligible.
- (4)
- The mechanical effects of concrete in the tensile area are negligible.
- (5)
- When the concrete is crushed, the concrete strain in the compressed area is uniformly distributed over a rectangular area.
- (6)
- The corrugation height is small compared to the height of the composite section; thus, the strain value at the horizontal centroid axis of the CSP can be used as the strain value of the full section of the CSP for calculation, and the strain value at the centroid is determined by the strain value.
4.3. Validation
5. Conclusions
- (1)
- CSPs can significantly improve the flexural capacity of concrete beams, and their reinforcement effect is superior to that of flat steel plates.
- (2)
- CSPs can effectively increase the downward movement space of the plastic neutral axis of reinforced beams. The stress height of the concrete increases so that the load-bearing performance of the upper compression reinforcing bar can be fully utilized. Additionally, this makes the lower bars and CSP difficult to yield, or the CSP difficult to yield in the full section.
- (3)
- The theoretical calculation formula for the moment of inertia of a combined section of CSP-reinforced beams and the analytical, theoretical value of the formula for the flexural capacity of concrete beams with corrugated steel reinforcement in the positive section were both in good agreement with the value of the four-point bending test and exhibited high accuracy. This shows that the proposed analytical theory of CSP-reinforced beams is reasonable and can be applied in practical engineering.
Author Contributions
Funding
Data Availability Statement
Conflicts of Interest
References
- Beben, D. Field Performance of Corrugated Steel Plate Road Culvert under Normal Live-Load Conditions. J. Perform. Constr. Facil. 2013, 27, 807–817. [Google Scholar] [CrossRef]
- Chen, W.Q.; Liu, B.D.; Liu, R.; Jing, L.J. Analysis of working effect of corrugated steel lining on tunnel lining fall. Tunn. Constr. 2018, 38, 384–388. [Google Scholar]
- Liu, D.J.; Zhong, F.; Huang, H.W.; Zuo, J.P.; Xue, Y.D.; Zhang, D.M. Present status and development trend of diagnosis and treatment of tunnel lining diseases. China J. Highw. Transp. 2021, 34, 178–199. [Google Scholar]
- Sun, D.W.; Liu, C.Y.; Wang, Y.Y.; Xia, Q.L.; Liu, F.Q. Static performance of a new type of corrugated steel-concrete composite shell under mid-span loading. Structures 2022, 37, 109–124. [Google Scholar] [CrossRef]
- Cao, Q.; Huang, J. Experimental study and numerical simulation of corrugated steel plate shear walls subjected to cyclic loads. Thin-Walled Struct. 2018, 127, 306–317. [Google Scholar] [CrossRef]
- Emami, F.; Mofid, M.; Vafai, A. Experimental study on cyclic behavior of trapezoidally corrugated steel shear walls. Eng. Struct. 2013, 48, 750–762. [Google Scholar] [CrossRef]
- Farzampour, A.; Laman, J.A.; Mofid, M. Behavior prediction of corrugated steel plate shear walls with openings. J. Constr. Steel Res. 2015, 114, 258–268. [Google Scholar] [CrossRef]
- Huang, M.L.; Sun, T.; Zhang, Y.Q.; Song, Y. Experimental research on mechanical properties of corrugated steel structure joint of primary support. Tunn. Constr. 2021, 41, 43–49. [Google Scholar]
- Nie, J.-G.; Zhu, L.; Tao, M.-X.; Tang, L. Shear strength of trapezoidal corrugated steel webs. J. Constr. Steel Res. 2013, 85, 105–115. [Google Scholar] [CrossRef]
- Peng, S.Q.; Fan, L.; Jiang, C.-R.; Zhou, J. Calculation and sensitivity analysis of corrugated steel bridge and culvert structure. J. Tongji Univ. (Nat. Sci.) 2005, 33, 1571–1575. [Google Scholar]
- Qiu, J.; Zhao, Q.; Yu, C.; Li, Z. Experimental Studies on Cyclic Behavior of Corrugated Steel Plate Shear Walls. J. Struct. Eng. 2018, 144, 04018200. [Google Scholar] [CrossRef]
- Rauch, A.F.; Sargand, S.M.; Hazen, G.A. Behavior of deeply corrugated steel plate in culvert. J. Struct. Eng. 1994, 120, 1651–1655. [Google Scholar] [CrossRef]
- Shahmohammadi, A.; Mirghaderi, R.; Hajsadeghi, M.; Khanmohammadi, M. Application of corrugated plates as the web of steel coupling beams. J. Constr. Steel Res. 2013, 85, 178–190. [Google Scholar] [CrossRef]
- Wang, X.R. Theoretics Analysis and Computation for Ribbed Shell Structure of 3D Ribbed Shell Plate and Concrete. Ph.D. Dissertation, Northwestern Polytechnical University, Xi’an, China, 2004. [Google Scholar]
- Sun, X.B.; Liu, B.D.; Li, C.H.; Li, T.S.; Zuo, X. Model test and numerical simulation of primary tunnel support structure using corrugated steel. Tunn. Constr. 2021, 41, 2058–2065. [Google Scholar]
- Wang, W.; Song, J.-L.; Su, S.-Q.; Cai, H.-L.; Zhang, R.-F. Experimental and numerical studies of an axial tension-compression corrugated steel plate damper. Thin-Walled Struct. 2021, 163, 107498. [Google Scholar] [CrossRef]
- Ye, L.D.; Yu, C.S.; Wu, T.X.; Li, J.J. Optimization of the Initial Support Structure form of Corrugated Steel in Mountain Tunnel. Mod. Tunn. Technol. 2020, S1, 158–164. [Google Scholar]
- Che, H.; Tong, L.; Liu, S.; Yang, Q. Field investigation on the mechanical performance of corrugated steel utility tunnel (CSUT). J. Constr. Steel Res. 2021, 183, 106693. [Google Scholar] [CrossRef]
- Li, G.F.; Ding, W.Q.; Ye, H.; Zhang, Q.Z.; Wang, Z. Study on construction Technology of corrugated steel prefabricated support structure in tunnel. Chin. J. Undergr. Space Eng. 2020, 16, 178–184. [Google Scholar] [CrossRef]
- Sun, T. Experimental Research on the Supporting Mechanism of Corrugated Steel Initial Support and the Mechanical Performance of Joints in Mined Tunnels. Master’s Thesis, Beijing Jiaotong University, Beijing, China, 2023. [Google Scholar]
- Wang, Z.; Zhang, Q.Z.; Pan, Q.; Liu, W.T.; Luo, Z.J. Construction method and mechanical characteristics of prefabricated corrugated steel shed tunnel. Chin. J. Undergr. Space Eng. 2020, 16, 185–193+207. [Google Scholar]
- Wei, D.Q. Suitability Study of Corrugated Steel Primary Lining Structure for Soft Rock Tunnel. Master’s Thesis, Chengdu University of Technology, Chengdu, China, 2021. [Google Scholar]
- Xu, J.D.; Li, G.F.; Li, L.; Jiang, H.; Li, W.H. A Preliminary Study of Assembled Corrugated Steel Arch Shed Cavern Structure. Mod. Tunn. Technol. 2018, S2, 1091–1098. [Google Scholar]
- Zhang, Z.; Li, G.Q.; Sun, F.F. Flexural behavior of the composite beam with corrugated webs. China Civ. Eng. J. 2014, 5, 34–39. [Google Scholar]
- He, J.; Liu, Y.; Chen, A.; Wang, D.; Yoda, T. Bending Behavior of Concrete-Encased Composite I-Girder with Corrugated Steel Web. Thin-Walled Struct. 2014, 74, 70–84. [Google Scholar] [CrossRef]
- Xie, M.J.; Zou, Y.; Wang, C.Q.; Qian, H.C.; Cao, L.; Chen, M. Experiment study on bending behavior of novel prestressed steel-encased concrete composite beam with corrugated steel webs. Eng. Mech. 2021, 38, 64–74. [Google Scholar]
- Kang, J.S.; Davidson, J.S. Structural effects of concrete lining for concrete-lined corrugated steel pipes. Struct. Infrastruct. Eng. 2013, 9, 130–140. [Google Scholar] [CrossRef]
- Liu, B.; Zhang, Z.; Zhang, M.; Wang, X. Experimental Study of the Mechanical Performance of Corrugated Steel Plate-Concrete Composite Structures. Int. J. Steel Struct. 2019, 19, 733–746. [Google Scholar] [CrossRef]
- Song, J.; Wang, W.; Su, S.; Wang, B.; Li, Y.; Lu, Z. Experimental investigation of the bond-slip behaviour between corrugated steel plates and concrete in CSRC structures. Constr. Build. Mater. 2021, 299, 124315. [Google Scholar] [CrossRef]
- Xia, Q.; Wang, Y.; Jelovica, J.; Liu, C.; Sun, D. Experimental study on corrugated steel–concrete composite semicircular arches under midspan loading. Structures 2022, 38, 1137–1150. [Google Scholar] [CrossRef]
- Zhong, T. Study on Axial Compression and Bending Performance of Corrugated Steel Tube-Concrete Steel Tube Member. Master’s Thesis, China University of Mining and Technology, Beijing, China, 2021. [Google Scholar]
- Wang, B.; Huang, Q.; Rong, X.L. ABAQUS-based load capacity analysis and validation of bolted joints. Sino-Foreign Highw. 2017, 37, 126–131. [Google Scholar]
- GBT 10433-2002; Cheese Head Studs for Arc Stud Welding. General Administration of Quality Supervision, Inspection and Quarantine of the People’s Republic of China: Beijing, China, 2002.
- Li, W.X. Theoretical and Experimental Study of Steel-Concrete Primary Stressed Beams with Different Degrees of Connection. Unpublished Master’s Thesis, Southeast University, Nanjing, China, 2018. [Google Scholar]
- Davies, C. Tests on Half-Scale Steel-Concrete Primary Stressed Beams with Welded Stud Connectors. Struct. Eng. 1969, 47, 29–40. [Google Scholar]
- Zhang, Z.N. Experimental Study on Mechanical Performance of CSP-Concrete Composite Structure. Master’s Thesis, Beijing Jiaotong University (BJTU), Beijing, China, 2018. [Google Scholar]
- Liao, C.Y. Research on Mechanical Properties of Prefabricated Corrugated Plate Lining in Mined Tunnel. Master’s Thesis, China University of Geosciences, Beijing, China, 2022. [Google Scholar]
Crack Characterization | Regularity Summary |
---|---|
Timing of crack appearance | Cracks appeared later in steel-plate reinforced beams than in unreinforced concrete beams. For the same amount of steel used, cracks appeared later in corrugated steel-plate-reinforced beams than in flat steel-plate-reinforced beams. For the same steel-plate material, cracks appeared later in steel-plate-reinforced beams with large thicknesses than in those with small thicknesses. |
Crack location | Cracks appeared at approximately the same locations in all five specimens, i.e., cracks were most likely to appear in and around the loaded sections. |
Crack type | The cracks in the five specimens underwent similar changes, and with an increasing amount of steel used, the cracks gradually changed from bending to bending-shear cracks. |
Crack length | The larger the amount of steel used in the five specimens, the shorter the vertical length of the cracks. |
Number of cracks | The number of cracks was significantly lower in RCBs than in steel-plate-reinforced beams and was similar among the four types of steel-plate-reinforced beams. |
Crack spacing | The crack spacing was more uniform in all five specimens. |
Crack distribution | Cracks in RCBs were distributed in the pure bending section. With an increasing amount of steel, the crack distribution in steel-plate-reinforced beams tended to move from pure bending toward bending and shear sections. |
Corrugation Thickness (mm) | Theoretical Calculation Results (mm4) | CAD Calculation Results | Deviation (%) | Composite Section Inertia Moment of Concrete Beams Strengthened with Flat Steel Plates with the Same Amount of Steel Used (mm4) | Improvement Rate of Inertia Moment of Concrete Beams Strengthened with Corrugated Steel Plates (%) |
---|---|---|---|---|---|
2 | 102,019,271 | 101,994,077 | 0.024701 | 77,765,606 | 23.77361 |
3 | 107,925,602 | 107,869,975 | 0.051569 | 82,139,723 | 23.89227 |
4 | 113,658,003 | 113,570,653 | 0.076912 | 86,696,520 | 23.72159 |
5 | 119,262,237 | 119,108,796 | 0.128824 | 91,398,600 | 23.36334 |
6 | 124,713,489 | 124,496,347 | 0.174416 | 95,199,596 | 23.66536 |
7 | 130,034,201 | 129,743,201 | 0.224289 | 99,174,510 | 23.73198 |
8 | 135,221,162 | 134,858,096 | 0.269221 | 102,980,529 | 23.84289 |
Specimen | Material Status | Test Bearing Capacity (kN) | Theoretical Bearing Capacity (kN) | Deviation Rate | Reasonableness |
---|---|---|---|---|---|
CSPCB-T3.0 | Concrete crushed Upper bars did not yield Lower bars yielded Corrugated steel plate yielded | 104.64 | 103.06 | 1.5% | Reasonable |
CSPCB-T5.0 | Concrete crushed Upper bars yielded Lower bars yielded Corrugated steel plate yielded | 147.01 | 154.47 | 5.1% | Reasonable |
SPCB-T3.5 | Concrete crushed Upper bars did not yield Lower bars yielded Flat steel plate yielded | 90.58 | 94.12 | 3.9% | Reasonable |
SPCB-T6.0 | Concrete crushed Upper bars yielded Lower bars yielded Flat steel plate yielded | 138.73 | 142.11 | 2.4% | Reasonable |
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2024 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
Share and Cite
Feng, X.; Liu, D.; Long, X.; Duan, K.; Zuo, J.; Liu, W.; Dong, H. Flexural Capacity of the Normal Sections of Concrete Beams Strengthened with Corrugated Steel Plates. Buildings 2024, 14, 1398. https://doi.org/10.3390/buildings14051398
Feng X, Liu D, Long X, Duan K, Zuo J, Liu W, Dong H. Flexural Capacity of the Normal Sections of Concrete Beams Strengthened with Corrugated Steel Plates. Buildings. 2024; 14(5):1398. https://doi.org/10.3390/buildings14051398
Chicago/Turabian StyleFeng, Xianda, Dejun Liu, Xiao Long, Kang Duan, Jianping Zuo, Wei Liu, and Haiyang Dong. 2024. "Flexural Capacity of the Normal Sections of Concrete Beams Strengthened with Corrugated Steel Plates" Buildings 14, no. 5: 1398. https://doi.org/10.3390/buildings14051398