Review

Customized Therapeutic Surface Coatings for Dental Implants

by
Muhammad Sohail Zafar
1,2,*,
Muhammad Amber Fareed
3,
Samiya Riaz
4,
Muhammad Latif
5,
Syed Rashid Habib
6 and
Zohaib Khurshid
7
1
Department of Restorative Dentistry, College of Dentistry, Taibah University, Al Madinah, Al Munawwarah 41311, Saudi Arabia
2
Department of Dental Materials, Islamic International Dental College, Riphah International University, Islamabad 44000, Pakistan
3
Adult Restorative Dentistry, Dental Biomaterials and Prosthodontics, Oman Dental College, Muscat 116, Oman
4
School of Dental Sciences, Universiti Sains Malaysia Health Campus, Kubang Kerian, Kelantan 16150, Malaysia
5
Centre for Genetics and Inherited Diseases (CGID), Taibah University, Madinah AlMunawwarah 42318, Saudi Arabia
6
Department of Prosthetic Dental Sciences, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia
7
Department of Prosthodontics and Dental Implantology, College of Dentistry, King Faisal University, Al-Ahsa 31982, Saudia Arabia
*
Author to whom correspondence should be addressed.
Coatings 2020, 10(6), 568; https://doi.org/10.3390/coatings10060568
Submission received: 23 May 2020 / Revised: 15 June 2020 / Accepted: 15 June 2020 / Published: 17 June 2020
(This article belongs to the Special Issue Advanced Coatings for Manufacturing Prosthetic Tubular Devices)

Abstract

:
Dental implants are frequently used to support fixed or removable dental prostheses to replace missing teeth. The clinical success of titanium dental implants is owed to the exceptional biocompatibility and osseointegration with the bone. Therefore, the enhanced therapeutic effectiveness of dental implants had always been preferred. Several concepts for implant coating and local drug delivery had been developed during the last decades. A drug is generally released by diffusion-controlled, solvent-controlled, and chemical controlled methods. Although a range of surface modifications and coatings (antimicrobial, bioactive, therapeutic drugs) have been explored for dental implants, it is still a long way from designing sophisticated therapeutic implant surfaces to achieve the specific needs of dental patients. The present article reviews various interdisciplinary aspects of surface coatings on dental implants from the perspectives of biomaterials, coatings, drug release, and related therapeutic effects. Additionally, the various types of implant coatings, localized drug release from coatings, and how released agents influence the bone–implant surface interface characteristics are discussed. This paper also highlights several strategies for local drug delivery and their limitations in dental implant coatings as some of these concepts are yet to be applied in clinical settings due to the specific requirements of individual patients.

1. Introduction

Natural teeth are commonly lost due to oral diseases such as tooth decay, periodontal diseases, and trauma [1,2,3] that affect appearance, speech, and the masticatory system. Aiming to improve patients’ quality of life by restoring lost teeth, function, and esthetics, dental implants are commonly used [3,4,5,6,7,8]. Dental implants are fixtures that are surgically embedded in the jaw bone to substitute the root part of the tooth [3]. Although intraosseous dental implants are usually cylindrically shaped, there are wide variations in terms of their dimensions and surface morphologies [9]. Dental implants are used to support fixed or removable dental prostheses following satisfactory osseointegration [10,11,12,13]. The term “osseointegration” was first devised by Brånemark, a Swedish orthopedic surgeon and a scientist who explored the growth and regeneration behavior of bone on titanium (Ti) implants [4]. Osseointegration was defined as a process of the formation of an effective and functional interface between the implant surface and bone [14]. The osseointegration of dental implants is essential for the long-term prognosis [14,15,16,17,18]. Osseointegration may be affected by a number of factors including the implant’s material properties, surface topography, and geometrical features [16,19]. Therefore, enhancement of the osseointegration of dental implants is always desired to achieve clinical success.
In terms of biomaterials, a variety of materials including metals [20,21,22,23], polymers [17,24,25,26,27,28], and ceramics [29,30,31,32,33] have been explored for dental implant applications. However, all materials have their own limitations; for example, metals have high-elastic-modulus and corrosion issues [34,35], polymers absorb water and usually have poor mechanical (wear, strength) properties [36], while ceramics are hard and brittle [36]. In the current scenario, Ti and its alloys are considered as the gold standard and material of choice for dental implants due to their excellent biocompatibility and osseointegration [37]. Commercially pure titanium (CpTi) has high strength, excellent biocompatibility, and corrosion resistance [23,34]. In addition, an oxide layer is formed upon air exposure that facilitates the material–bone interface through the apposition of bone matrix [38,39]. The commonly used titanium alloy included Ti-6 aluminum-4 vanadium (Ti6Al4V) that is preferred due to its better mechanical properties and excellent biocompatibility [36]. However, toxic effects from the release of vanadium and aluminum remain the main concern for these alloys [40]. Although the Young’s modulus of elasticity of Ti and its alloys (~110 GPa) is lower than that of cobalt chrome alloys, it is still remarkably greater than the Young’s modulus of elasticity of bone (10–30 GPa) [41]. Such a gross mismatch in the elastic moduli results in an uneven transfer of stresses (stress shielding), and atrophy of bone, leading to the loosening and failure of implants [42]. On the other hand, using an implant material with lower elastic moduli enhanced the homogeneous stress distribution at the implant–bone interface, thus reducing the bone atrophy [43]. To overcome such issues and to improve the implant material–bone interface, various surface treatment and coating options have been explored for the last few years. As a result, a few surface-modified dental implants are commercially available for clinical use [44].
Considering that the biological tissues establish an interface with the materials’ surface, the surface modifications (etching, sandblasting, and anodizing) enhance the materials’ biological response and osseointegration without affecting the bulk properties [45,46,47,48]. In addition to surface modifications, surface coatings of dental implants using a variety of materials and biomolecules have been explored in recent decades [49,50,51,52,53] to achieve certain beneficial effects. For example, the coating of bioactive materials (calcium phosphates and hydroxyapatite (HA)) enhances the surface bioactivity, leading to an improved bone–implant interface [54]. Similarly, coating implants with various pharmacological agents such as bisphosphonates [50,55,56,57], antibiotics [49,58], antimicrobial peptides, and biomolecules [59,60,61] has been reported with promising outcomes in terms of surface properties and therapeutic effects. Additionally, the release of medicaments from implant coatings may have certain therapeutic effects for a certain period of time depending on sustained or controlled release. Therefore, to achieve the targeted drug delivery and beneficial therapeutic effects (such as reduced bacterial activity, and enhanced osteoblastic proliferation and activity), drug elution is desired for a prolonged period of time. The present article reviews various interdisciplinary aspects of surface coatings on dental implants from the perspectives of materials, coatings, and drug release. Furthermore, the various types of implant coatings, localized drug release from coatings, and how released agents influence the bone–implant surface interface characteristics are discussed.

2. Mode of Action of Drug-Releasing Coatings

Drug release from implant coatings has attracted the attention of the scientific community around the globe. Classification of implantable drug-releasing devices is not straightforward, due to the presence of many complex implants belonging to hybrid categories [62]. Nevertheless, based on the release potential, drug releasing can be categorized as active or passive. Examples of the structures of different kinds of carrier-based drug delivery systems are shown (Figure 1). Generally, in passive implants, the drug-releasing characteristics are uncontrollable once installed clinically. In passive implants, the drug-releasing potential is eventually governed by the nature of the implant material and drug formulation. Biodegradable and non-biodegradable implants are two subtypes of passive implants. An encapsulated drug in a biocompatible polymeric matrix is a typical example of passive implants. In such implants, modification of numerous key parameters such as the nature of the polymer backbone, drug type or its concentration, implant design, and surface characteristics are varied to control the drug-release kinetics. However, implants are normally metallic in nature where the elution of therapeutic agent is activated by external stimuli targeting the optimal regulation of drug dosage according to the patients’ requirement and therapeutic effects [63].
Drug-eluting implants impart healing in addition to their regular task of support. For example, healing therapy is facilitated by controlled release of drug molecules from the implants into the surrounding environment. Drug release is a well-known research area of drug delivery. Due to the recent technological advancement, a plethora of new materials with improved functions and applications have been investigated and incorporated into the development of drug delivery biomaterials. Many macromolecules having natural or synthetic origin have shown excellent potential in controlled drug-release platforms. Most common platforms for sustained drug release include polymer coatings, the drug itself, or a ceramic material. Controlled drug release can be attained by coatings of pH-responsive, as well as enzymatically degradable, soluble polymers [65,66]. Controlled drug release plays a crucial role in maximization of the bio-efficacy and improvement in the quality of life. Drug elution is a process that involves the transfer of drug molecules (the solutes) from the original position to the matrix (biomaterials) to the external surface and then releases in the medium in a controlled or desired manner [67].
A drug carrier implant consists of active molecules (drugs) either on its surface or within the bulk structure, designed in such a manner that it should both retain the activity of the drug for a specific time period and control the release rate as well. Typically, the release of therapeutic agents around the local environment of an implant is governed by diffusion or osmatic pressure and via matrix degradation [68]. Generally, a drug is released through four main mechanisms: (1) Diffusion-controlled, (2) solvent-controlled, (3) chemically controlled (such as polymer degradation), and (4) pH-sensitive. Diffusion-controlled drug-eluting systems are of two types: (a) Reservoirs and (b) matrices. Similarly, chemically controlled drug release is achieved by two main routes: (a) Material biodegradation, and (b) chemical cleavage of the drug moiety from a biomaterial. On the other hand, solvent activation phenomena comprise either osmotic effects or swelling [67]. Many mechanisms have been investigated that describe how drug release behavior of a drug from a particular matrix is controlled (Figure 2).
Physiochemical and biological mechanisms such as dissolution, diffusion, portioning, erosion, osmosis, swelling, targeting, and molecular interactions between the matrix and drug are frequently involved in controlling the drug release [70,71,72]. A drug-eluting implant can exhibit either one or a combination of more than one mechanistic model for an effective controlled drug release. During a drug release process in targeted applications, these mechanisms either exhibit their role at different stages or in a simultaneous fashion. Therefore, the classification of controlled drug-releasing models pertaining to drug release is based on the main mechanisms [73,74]. The major aim of the drug-eluting models is to permit an effective, benign, and reliable supply of the drug to the target site during therapy, and to obtain an anticipated therapeutic response. To this end, the controlled drug release phenomenon is considered critical to keep the drug concentration in the blood (or in a localized area in the case of dental implants) within the therapeutic range [75].

3. Controlling the Drug Release from Coatings

The elution time period of the drug molecule strictly depends upon the technical topographies integrated in implant coatings and the drug load. A range of nanomaterials including polymeric systems [76,77], hydrogel-based models [78,79,80], and nanoporous materials [81,82] have been explored for the manufacturing of drug-eluting dental implants. A novel drug delivery model should ensure drug safeguard from a hostile environment, plausible controlled release (in response to environmental stimuli like temperature or pH), and selectivity of a drug to specific organs, cells, or tissues in order to show improved pharmacodynamic parameters of the drug [83,84]. Multiple factors influence drug release kinetics during therapy. A brief summary of these driving factors is shown in Figure 3.
Many drug-embedding approaches such as incorporation of the drug in the surface coatings, soaking, and chemical bonding have been used, but the burst release of drug molecules provides less control upon drug elution kinetics. Potential drug release around the local environment of an implant is directly related to molecule size, drug solubility in the released medium, ionic charges, and the molecular weight of drugs [85]. Therefore, fundamental characteristics of drug molecules have a strong association with the plausible release of the drug from the matrix for optimal therapeutics. Creel et al. showed that drug hydrophobicity and hydrophilicity have a strong association with drug release. The nature of the drug affects its aqueous solubility, protein binding, local drug concentrations, and tissue retention characteristics [86]. The physicochemical properties of the drug molecules are important in governing their transportation mechanism and binding potential with tissues during the course of drug delivery. Although hydrophilic drugs exhibit free distribution but rapid clearance remains the major concern. The hydrophilic nature of drugs encapsulated in a matrix is not adequate to control the drug release mechanisms, so nanogels have also been reported to delay release kinetics (rates) and offer multiple release kinetics, unlike the pure-Fickian mechanism [87,88]. However, hydrophobic drugs show insoluble behavior in aqueous media, binding potential with fixed tissue elements, and more tissue residence and biological effects [86]. Kamath et al. showed that diffusion or dissolution characteristics of drug molecules affect their release kinetics [89]. Drug release, if governed by the pure diffusion mechanism, is very quick due to the high in vivo clearance [78,79]. To attenuate the diffusional drug release of molecules, biorthogonal strategies were introduced to develop an affinity bond between the polymeric network and peptide (an affinity-based approach) that covalently links a small protein receptor and the observed tunable release rates [90]. Many other investigators have shown similar approaches but developed different functionalization methods for linking drug molecules to the polymeric network [78,91,92].
Venkatraman et al. [93] demonstrated that solubility in the polymer (matrix) also affects the release kinetics of drug molecules. The study inferred that in multilayered coating implants, the drug release was diffusion and degradation-controlled (dominant under high water intake), and the drug load did not affect the release kinetics [93,94]. Too fast a drug release before reaching the target site may lead to the toxicity and decrease in the drug’s concentration, while too slow a release can hamper the drug efficacy at the target site. Likewise, Ranade et al. found that the higher solubility of the drug molecule in release media showed a higher drug release rate, which is not required for optimal controlled release [95].
As the properties of rate controlling may influence the release kinetics of drug molecules, several characteristics such as initial molecular weight of the polymer, co-polymer ratio, pH of the medium, absorption rate, and time period significantly influence the degradation behavior and drug release time period in the case of biodegradable materials [96,97]. A number of studies have shown that thermal properties such as glass transition temperature and crystalline melting temperature of rate-controlling polymers also affect the degradation of the matrix, hydrophobicity, drug release, and solubility in the case of biodegradable materials [98,99]. For drug release from matrix systems, the degree of crystallinity is another factor that affects water diffusion and drug solubility, and influences biodegradation and drug-release biomaterials [99,100,101].
Processing parameters also play a crucial role in drug delivery and influence the drug release kinetics. Several studies have shown that a selection of coating methods such as air brush, ultrasonic atomization, and dip coating can affect coated film characteristics and drug release [102,103,104,105]. Furthermore, solvent properties such as the boiling point, and evaporation kinetics also significantly influence the residual solvent, merging of coatings, and release kinetics [106].
The coating design further influences the release kinetics of drug molecules. Kamath et al. found that the drug-to-matrix ratio influenced the drug loading capacity of matrix and drug elution [89]. A careful optimization of the drug-to-matrix ratio [89], drug density [107], compatibility between drug and matrix [108], physical dimensions of coatings or the coated device, and processing parameters can provide adequate control over the rate of drug release. Raval et al. [109] investigated that coating layer features such as composition and topography further influence the diffusion of the drug through the coating. An adequate control over drug release was achieved by coating the matrix and can be explained by an initial burst release and dissolution. Additionally, a process was recently reported in which a drug moves within the device in multiple layers to provide different drug release rates [109]. Balakrishnan et al. [110] showed that drug concentration and distribution within complex polymeric coatings can be comprehended by a simple Fickian’s diffusion model [89,110]. Furthermore, the microstructure of the coating can exhibit processing conditions and eventually affect drug release kinetics. The thickness of the surface layer of the coating and hydrophobicity of the biomaterial also control drug release kinetics by lowering the diffusion process [111]. Otsuka et al. found that mechanical properties of the coated film also affect coating integrity [112].

4. Desired Properties for Drug-Releasing Dental Implants

The main aim of the drug-eluting implant is to achieve a favorable host response and beneficial effects through the effectively controlled, benevolent, and reliable release of the active drug at the localized site. It is critical for eluting implants to release a drug in a controlled manner, maintain a therapeutic concentration at the local site for a feasible period of time [75], and a sustained release of the therapeutic drug [113]. Therefore, an ideal drug-eluting implant coating should release active agents in such a manner that it maintains the drug concentration for a specific period of time, which is required for the targeted therapeutic action. The implant coating should be biocompatible; the eluting active drug or the matrix biodegradation should not have any toxicity or harmful effects both locally and systemically. In addition to excellent biocompatibility, the dental implant coating is desired to improve the tissue–biomaterial interface and to enhance osseointegration. Consequently, bioactive material coatings are known to encourage bone formation and are preferred over bioinert and biotolerant coatings (Figure 4).
As discussed earlier, osseointegration is essential for the stability and clinical success of implants. According to the original definition, osseointegration is the direct contact between bone and a loaded implant surface at the microscopic level [14]; however, more recently, it is described as an immune-driven demarcation response (type IV hypersensitivity) to a foreign body Ti implant that is immovable (ankylose) in bone [114]. This biotolerant nature of commercially pure Ti encourages contact osteogenesis [115] due to close apposition of the bone on their surface (Figure 4). It is well established that Ti is stable in a biological environment and does not trigger a foreign body reaction. Several in vivo and in vitro studies have successfully demonstrated that the clinical success of a dental implant and the resultant osseointegration is directly linked to the implant surface properties such as chemical composition, micro/nano-structured surface topography, and hydrophilicity [37,116,117]. By contrast, failure to osseointegrate results in alveolar bone resorption, loosening, and, ultimately, failure of the implant [118].
The main reasons for failure to establish osseointegration include patient-related factors (poor bone quality and volume, presence of periodontitis, poor systematic health, and smoking) [119,120] and implant characteristics (such as surface texture, shape, and biomaterial) [17,121]. Accordingly, the current research [48,122,123,124] focused on improving the bone–implant interface and osseointegration while studying various surface treatments for dental implants. To further improve the osseointegration of dental implants, a number of surface modifications had been considered; the hydrophilic surfaces promote cellular adhesion by means of various surface modifications and coatings. Additionally, surface coatings of osseoconductive materials (calcium phosphate (CaP) and HA) promoted the surface properties [125,126].
Immobilization of bioactive materials, osseoconductive biomolecules, and growth factors has been reported to enhance the osseointegration [127]. Additional features (such as bactericidal activity, enhancement of cellular attachment, and inhibition of bacterial film formation) can be added to the implant coatings that are also beneficial in improving the implant–tissue interface and clinical success. In terms of mechanical properties, the implant material is required to have properties approximating the tissues to be replaced. For example, a gross mismatch of Young’s modulus of elasticity and compressive strength of the implant material and bone is likely to generate areas of stress concentration, bone atrophy, loosening, and failure of the implant [42]. Therefore, the implant surface should have a modulus of elasticity, strength, wear, and fracture resistance [128,129] approximating that of alveolar bone [36].

5. Methods of Drugs Coating on Dental Implants

The purpose of implant modification with drugs and biomolecules is not only to retain the bioactivity but also to minimize complications linked to uncontrolled drug delivery dose. Soon after the insertion of the dental implant in the bone, it is covered with a biofilm containing blood cells, proteins, extra cellular bone matrix ions, cytokines, and growth factors that influence migration, growth, adhesion, and differentiation of the bone cell [130,131]. Three main methods including physisorption, covalent binding, and carrier systems [132] are reported in the literature to describe the modification of implant surfaces with proteins, enzymes, and peptides immobilization (Table 1). Moreover, desirable results are obtained by immobilizing growth factors on a nano-coating surface having a higher surface area and affinity. A simple dipping method is used for the adsorption of biomolecules, but this has the drawback of a limited control over the release kinetics and drug delivery, resulting in a disturbance in the retention of the adsorbed molecules, which depends only on weak van der Waals forces (physisorption) [132,133]. Similarly, a controlled drug release is achieved by the physical entrapment of biomolecules in the carrier system, which is attached by a barrier but not chemically bound [134]. The covalent binding of biomolecules to surfaces is a more complex but alternate method of therapeutic agent delivery, which is covalently bonded to the implant surface and releases a lower amount of drug but has a higher loading potential [36,135,136].
The clinical use of localized drug delivery via dental implant surface coatings is still under research and development and not yet well established. In several experimental models, a variety of implant surface modifications to carry different therapeutic agents have effectively been studied. The most common methods for localized drug delivery include the surface treatment or surface modification of implants [58,137,138], microsphere loading [139,140], therapeutic agent loading via scaffolds with a miniature [141,142], loading a hollow cylindrical implant with growth factors and biological molecules [139,143], and photodynamic therapy of implants to drug delivery [144]. However, local pharmacokinetics and predictable quantitative drug elution to an individual targeted dental implant in the peri-implant space site are still at the experimental stage. A sufficient amount of drug delivery into the healthy/inflamed soft tissue around dental implants is also limited by the thickness of the gingival epithelium, and mucosal permeability [145,146]. Therefore, implant surface modifications offering controlled and effective drug elution over a control time due to biodegradable or non-degradable polymers at the nanoscale are possible via structural modification of implant coatings [145].
As discussed, the biochemical methods of implant surface modifications offer a good alternative to physiochemical treatment and topographical alterations of the dental implant (Table 1). These biochemical functionalization approaches study the interaction of host tissue cells (peptides and extracellular proteins) and the implant interface. A good review of in-vitro and in-vivo studies of surface modification by peptides or extracellular matrix proteins on the Ti implant surface reported that these physicochemical interactions of immobilized biological agents is an effective way to stimulate the bone regeneration and enhance cell adhesion remarkably [36,147]. For example, the increase in surface roughness from micron to sub-micron scales (Figure 5) resulted in enhanced differentiation of osteoblast and tissue regeneration, especially when a combination of both micro- and nano-sized surface roughness topographies are employed together [148,149].
Table 1. Methods of biochemical modification and immobilization approaches for bioactive molecules on dental implant surface.
Table 1. Methods of biochemical modification and immobilization approaches for bioactive molecules on dental implant surface.
DescriptionProblems/BenefitsConsequencesExamples
Physisorption or Adsorption [130,133,136,150,151]
Depending on the implant surface features (roughness, chemistry, surface energy, and wettability), which results in spontaneous adsorption of drugs and therapeutic agents on Ti implant surface via weaker van der Waals forces.Lack of control over the delivery of molecules.
Several parameters such as micro movement of the implant, pH, temperature, and solvent conditions
It is achieved by dipping method
Uncontrolled adsorption from the surface
A burst release system, (80%–90%) in 1 h of adsorbed molecule
Superficially adsorbed BMP-2 released rapidly in higher concentration
Covalent Binding [134,152,153,154,155]
Cellular adhesion of proteins via covalent bond to prevent systemic effects of drugsImmobilization of molecules promote mineralizationProteins bond to the implant surface directly or through a spacer such as hydroxyl (−OH) or amine (−NH) groups Cell-adhesive proteins (collagen, osteopontin, fibronectin, or vitronectin)
Carrier Systems or Self-Organized Nanoporous Surfaces on Silicon, Aluminum, and Titanium [132,136,156,157]
Direct integration of drug into the coating material via carrier molecules (polylactide, polyglycolic acid, hydrogels, polypyrrole, and CaP/HA coating)Growth factors or antibiotics are incorporated into a HA coating; can be delivered in a physiologic-like mannerAntibiotics, proteins, and growth factors are entrapped in crystals formed by precipitation of CaP/HA solutionA slow-release system,
protein loaded into the carrier can be 10 times higher than adsorption
More recently, there has been interesting developments related to the use of porous titanium-based implant materials. There are two common methods to produce porous implant surfaces modifications with highly defined external dimensions: Selective laser melting (SLM) and atomic layer deposition (ALD). In the SLM process, a selective consolidation of melted titanium powders coating layers generated a complex 3D personalized implant surface using focused thermal energy of a computer-controlled laser beam to produce an optimum surface [158,159]. Liu et al. compared surface coatings produced by SLM and sandblasted-large-grit-acid-etched (SLA) methods on dental implants and reported the higher mineral apposition rate of the SLM implant and enhanced osseointegration to the surrounding bone tissue after 12 weeks [160]. Moreover, coating of the SLM-fabricated porous Ti implant surface with CaP and magnesium to encourage bone formation is an attractive development [161]. Recently, investigators have reported a novel ALD method of CaCO3 films on the Ti6Al4V to coat HA and TiO2 nanotubes (TNT) to produce a bioactive Ti6Al4V/TNT/HA coating surface with optimal biocompatibility, antibacterial activity, topography, and mechanical properties. In addition, it was claimed that the ALD system has resulted in enhanced fibroblast cell adhesion and proliferation along with good antibacterial activity [162,163].

6. Understanding Coating–Implant Adhesion Interface

The interaction of the implant coating surface and the host tissues is considered one of the main factors for the long-term clinical survival of dental implants [164]. This implant–bone interface is determined using bone formation on the implant surface toward the bone (contact osteogenesis) and bone formation from the old bone toward the implant (distance osteogenesis) [115]. There is an influence of topographical and wetting characteristics on coating–implant adhesion. Surface modifications of the dental implant are important for the clinical outcome and implant–bone interface success and is achieved by a variety of coating procedures, as shown Figure 6 [37,115].
The influence of surface roughness, topographic characteristics, and wetting behavior of submicron- and nanocoatings on the differentiation of cells and tissues around dental implants is well-documented. To accelerate the osseointegration, the contact osteogenesis is largely dependent upon the modification of implant coating surfaces [115,165]. Therefore, several techniques have been reported regarding implant surface modification at submicron (1–10 micron)-level topographical modification and the addition of nanotechnological chemical features to the implant surface [165]. The fundamental coating principle of commercially pure titanium (cp-Ti) implant modification was intended to improve the early biological response (growth factors release from the bone matrix) to dental implants that commenced at the surgical osteotomy sites [166]. Additionally, the long-standing clinical survival of dental implants demands that the bone remodeling process should be harmonized with the modified implant surface to achieve predictable success. It is believed that the chemical and physical nature of the implant coating surface improves the quality and speed of the healing process [167]. Figure 6 describes two types of implant modifications of grade 4 CpTi, namely micro-roughened modification (sandblasted-large-grit-acid-etched (SLA) surface and anodic oxidation) and molecular modification (TiO2 nanotube, functional peptides, fluoride treatment, HA/CaP compounds, photo-functionalization, and laser ablation). However, some of the recent nano-level modifications presented in Figure 6 have not yet been clinically tested in humans, but these nanoscale surface-modification techniques have shown excellent in vitro and in vivo data; thus, they have promising potential for future clinical use. Nonetheless, biomechanical, micro-radiographic, histological, and drug-elution studies should be conducted in a controlled environment before such experimental coated implants are placed in humans.

7. Therapeutic Dental Implant Coatings

Current biomimetic approaches regarding dental implant coatings encompass the fabrication of biocompatible nanomaterials to effectively control the processes of tissue regeneration, cell adhesion, proliferation, and differentiation. A variety of organic and inorganic nanocoating agents have been studied to achieve optimum therapeutic outcomes from dental implant-coating materials (Table 2). Therefore, there is potential to improve osseointegration along with therapeutic effects by immobilization of bioactive agents, osseoconductive drugs, and growth factors on implant coatings via several possible surface treatments and coating agents [168].

7.1. Biomimetic and Bioactive Coatings

To improve the osteoconductivity and osseointegration of dental implants, the biomimetic layers of calcium phosphate (CaP) and hydroxyapatite (HA) coatings had been deposited on implants. One of the most successful current clinical therapeutic coatings of dental implants employed to achieve biocompatibility and enhanced peri-implant bone formation is CaP and HA [48,217,218]. Earlier, the plasma-sprayed HA coating was thick and rough, which resulted in clinical failures and cracking; however, new physical deposition and chemical techniques facilitated the deposition of thinner (100 nm) CaP/HA coatings having an accelerated and increased bone formation [37,219]. Similarly, organic implant nanocoatings comprising proteins, growth factors, polysaccharides, and drugs were incorporated into the latticework of CaP and HA for numerous therapeutic properties [173,215,217].
An accelerated osseointegration during the early healing phases can be obtained using implant coatings having a composition similar to the human bone [220]. For example, the CaP apatite composition is similar to the mineral bone phase and activates osteoblast cells to initiate bone tissue formation [221]. In addition, bioactive implant surfaces significantly reduced the time required for osseointegration of Ti implants due to improved wettability and better protein adsorption capacity. The bioactive implant coating is characterized by stimulation of the biological activity of surrounding bone tissues (Figure 1). Mostly, nanocoatings, where the coating thickness ranges from 1 to 100 nm, are bioactive [222,223]. Several organic and inorganic molecules have been reported to provide enhanced bioactive nanocoating bonds on the implant and bone interface (Table 2). It is well documented in the literature that the micron/submicron-scale surface roughness enhances osseointegration through osteoblast differentiation [58,115,173]. Moreover, Gittens et al. suggested that the combination of micro-/submicron-scale roughness along with nanoscale structures in vivo improves osteoblast differentiation to indicate the potential for improved implant osseointegration [149]. Bioactive interactions lead to a close adhesion and interconnection along the interface of the implant and surrounding tissues [224].
Following implantation of the CaP-coated implant, Ca and P are released into the surrounding tissues and stimulate precipitation of apatite on the implant surface [180,181]. The stimulation of new bone formation in the case of CaP-coated implants enhances the healing and the clinical success rate [225]. The biomimetic CaP-coated implants establish a greater bone-to-implant contact area compared to uncoated implants [226,227]. These findings and long-term success rate advocated an improved interface and osseointegration in the case of CaP-coated implants.

7.2. Antibacterial Coatings

Infections associated with dental implants are often very complex, multifactorial, and challenging to manage. The most common bacterial infections related to dental implants are Gram-positive bacteria, i.e., Staphylococcus epidermidis, Staphylococcus aureus, and Enterococcus spp., and Gram-negative bacteria, for example, Pseudomonas aeruginosa [191,228,229]. The implant surface provides a medium for bacterial adhesion by forming a physical defensive biofilm and diminishes the systemic antibiotic diffusion, resulting in relatively limited drug availability at the infection site [230]. Therefore, scientists are constantly making efforts to develop and optimize antibiotic-loaded therapeutic coatings for dental implants to treat chronic peri-implant infections [164,231,232]. Several therapeutic modifications of implant coatings treating localized implant–bone infections have been proposed by incorporating antibiotics, antimicrobial peptides, and disinfectants. In order to avoid and treat a potential infection adjacent to the implant–bone (host–device) interface, the following should always be considered regarding drug-loaded implant coatings [232,233]:
(a)
As acute infections occur immediately after implant surgery, short-term antimicrobial drug delivery coatings to the host tissues and device interface would help to prevent bacterial colonization, thus preventing the infection.
(b)
Similarly, long-term bacteria can colonize the implant surface; therefore, consistent antimicrobial drug delivery coatings are required to inhibit microbial colonization on the surface over time.
(c)
It is important that, while maintaining both long and short-term drug elution from implant coatings, there should be no alteration in the surface materials’ properties; otherwise, it may deteriorate the implant’s osseointegration.
A number of studies [58,228,231,234,235,236] have investigated the incorporation of antimicrobial agents to the implants’ coating using dip or spray coating methods. However, it is very challenging to meet the desired requirements during production of implant coatings. A controlled and sustained local drug delivery from dental implants has a substantial potential to replace the use of systematic drugs due to the adequate physiological stability and availability at the local implant site, thus reducing the toxicity risks and higher cost [233,237]. Antimicrobial agents are generally adsorbed on the surface via dip or spray coating methods, but the adsorption of antimicrobial molecules to the implant surface is very weak, which may precipitously cause damage in physiological situations. Due to this reason, the release of antimicrobial agents may either have a relatively short-term potency or result in rapid desorption of the antimicrobial from the implant surface [229].
Consequently, the antibiotic-loaded (gentamycin, amoxicillin, and vancomycin) bioactive coating on dental implants is an attractive possibility to treat the localized infection site by increasing infection prophylaxis confined at the implant site. Various antibacterial implant coatings showing antimicrobial activity to the implant–bone junction have been investigated (Table 2).
Gentamycin is a widely used broad-spectrum antibiotic for coating the implant surface along with the layer of HA to act as a local prophylactic agent [191,209]. Previously, a biodegradable gentamicin-polylactic acid-coated implant was investigated using a rat model. It was reported that adding 10% gentamicin to the polylactic acid coating remarkably decreased implant-related infections [209]. An in vitro study investigated titania nanotubes loaded with gentamicin and reported therapeutic release of the drug, reduction in bacterial adhesion, and enhanced osteoblastic activity [238]. Elution of therapeutic drugs significantly reduced the bacterial adhesion and enhanced osteoblastic differentiation [191,231,239]. Similarly, tetracycline coatings enhanced the attachment and retention of blood clots on the surface during an earlier phase of healing, thereby promoting osseointegration [58].
Vancomycin loaded silica sol–gel film on the implant demonstrated a slow release of vancomycin [210,211,212], resulting in a lower adherence of bacteria such as Staphylococcus aureus to the Ti implant. Vancomycin was covalently attached to the implant surface to make an antibacterial surface to prevent the bacteria attachment for a long time [240]. Ferreira et al. incorporated nanotubes loaded with doxycycline on the dental implant surface to deliver the antibiotic locally and reported that P. gingivalis growth was suppressed in the experimental media during a 28 day time interval [214]. Likewise, it was reported recently that an implant surface coated with doxycycline prevented bacterial colonization to control peri-implant mucositis and peri-implantitis [213].
Norfloxacin-biocompatible antibacterial nanocoatings for dental implants containing norfloxacin have been reported using the novel method of nano-spray drying technology along with nanocoatings of poly(lactic-co-glycolic acid) as a biodegradable polymer and norfloxacin as a model antibiotic [215]. The adsorption of the norfloxacin antibiotic was carried out on the nanoparticles obtained from CaP, demonstrating a controlled drug delivery from these nanorod-like structures with an antibacterial potential [241].
Chlorhexidine (CHX) is a broad-spectrum organic antimicrobial and antifungal agent, which is well known in the treatment of several periodontal pathogens [242]. It was absorbed on the Ti implant by inducing surface mineralization with the HA coating [58,216]; however, the resultant CHX-coated surface helped to reduce the bacterial load for a limited time due to short-term antibacterial properties. The CHX-hexametaphosphate nanoparticle was used to fabricate a porous coating on the Ti implant surface having a concentration equivalent to 5 mM of CHX for dental implant coatings [243]. Moreover, CHX delivery from the CHX-polybenzyl acrylate Ti implant coating resulted in inhibition of streptococci adhesion, particularly useful to control bacterial infection around the dental implant during the early phase of implant placement [244].

7.3. Antimicrobial Metallic/Metalloid Coatings

A range of metallic biomaterials with antimicrobial properties have been investigated for implant coatings (Table 2). Silver, zinc, and copper are the most widely used biocidal, bactericidal and bacteriostatic metallic agents having higher efficiency against broad spectrum pathogens [165] and no toxic effects when used in a controlled concentration. The antibacterial activity of silver electrodeposited on tricalcium phosphate (TCP)-coated titanium implants showed the desired bactericidal activity without toxicity in the optimal silver concentration [245,246]. Similarly, the cold-spray coating technique utilized polyether ether ketone (PEEK), silver-doped HA powder, and the chitosan–copper composite for creating antimicrobial implant coatings [247,248].
Recently, different types of graphene implant coatings (reduced graphene oxide and graphene oxide) have been explored as an attractive option for an implant surface coating material due to their higher biocompatibility and antibacterial effects. Several in vivo and in vitro studies have reported a very high surface area and improved osseointegration of a graphene-based implant coating [172,249]. Zeng at el. reported that a graphene/HA coating deposited on the Ti implant showed better biocompatibility, higher bond strength, and better bioactivity compared to only a HA coating or only CpTi [250]. Moreover, the antibacterial activity of graphene is due to the damaging of cell membranes through oxidative stress against multi-resistant bacteria and fungi species [251]. Although a very limited amount of research has been conducted for graphene application-coated dental implants, this material has created new horizons in drug delivery and tissue engineering applications in the near future. In addition, nano-diamonds have been reported for their bioactive and bactericidal potential for implant coatings, thereby enhancing osseointegration and reducing the incidence of peri-implantitis [50,178]. The nano-diamonds surface contains oxygen-carrying groups and charges that are responsible for antimicrobial properties [252]. Silver and nano-diamond implant coatings showed antimicrobial properties against Escherichia coli [169]. Biocompatibility of potential coating materials is essential. Vaitkuviene et al. [253,254] comprehensively investigated the biocompatibility of nano-diamond materials using neural cells. It was reported that the thin coating of oxygenated and boron-doped nanocrystalline diamond (BDD) significantly improves the cellular adhesion and proliferation of neural cells. These findings demonstrated the nano-diamond coatings’ good biocompatibility and potential for maintaining the cell viability and proliferation [253]. Another in vivo study [255] investigated the biocompatibility of BDD using an animal-based implantation model. Although the formation of a thin fibrous capsule and mild inflammation was observed, there were no significant differences comparing BDD and the control titanium alloy [255]. The biocompatibility of the nano-diamonds may vary depending on the materials’ properties and target tissues. The larger diamond particles (100 nm or more) showed better biocompatibility than smaller particles [256,257]. However, further studies are required to evaluate the nano-diamonds’ biocompatibility using various types of cells and materials’ parameters. In addition, the current literature determining the mechanical properties and bond strength of nano-diamond coatings on dental implants is scarce and requires further research.

7.4. Antimicrobial Peptides (AMPs) Coatings

Antimicrobial peptides (AMPs) are covalently bonded or physically adsorbed on the implant surface after being derived from human proteins. The broad spectrum capability of AMPs has an effect of antimicrobial activity; therefore, they are particularly useful due to the low host cytotoxicity and bacterial resistance [191,258]. Lee et al. reported that the dual-drug-eluting (gentamicin and bone morphogenetic proteins) Ti implant system can reduce infections and improve osteointegration [191]. In the last two decades, the resistance of antibiotics and microbial agents combating was compromised due to superbugs [259]. This problem is the main hurdle in the successful osseointegration of dental implants and has compromised the oral health in adult, as well as in geriatric, patients [260]. For this reason, new antimicrobial drug approaches are being investigated such as coatings of the antibiotics, laser treatments of the surface, and peptides binding with bioactive ingredients [261,262]. The human body is made up of millions of proteins and peptides and play their role in maintaining body defense, repair, and regeneration. Proteins are genetically coded for their specific functions. Therefore, studying the structures of these proteins and synthetically designing for specific functions can be very futuristic.
The antimicrobial peptides (AMPs) are a natural weapon for the defense against microbes [263]. These AMPs are present in the human body epithelial and non-epithelial surfaces, maintaining natural barriers and fighting against microbial invasions. The oral cavity has a dynamic environment and is lined by specialized mucosa and secretary glands, helping in expressing the defensins, cathelicidins, histatins, statherin, adrenomedullin, and neuropeptides [264]. All these antimicrobial peptides have different roles in the defense of the oral cavity against microbes, viruses, and fungi. In addition, the composition of human saliva is full of bioactive ingredients with potential diagnostic and monitoring capability. There are many proteins and peptides identified from human saliva such as the statherin family, which helps in the remineralization of the dental hard tissues. Table 3 enlisted various AMPs commonly found in the oral cavity.
The AMPs act against oral microbes by various approaches including the barrel-stave model, carpet model, and toroidal model (Figure 7). It is not proven which is more dominant, but in the last few decades, many experiments have been reported on the basis of the proposed models. In the barrel-stave model, peptides can position themselves to attach to the microbes’ cell membranes, leading to the aggregation process of peptides and bilayer formation (Figure 7a) [264]. A prolonged or carpet-like layer formation by the disruption of the cell membranes by peptides is known as the carpet model (Figure 7b). In the toroidal model, all the attached peptides begin to aggregate and bind to the lipid monolayer through pores (Figure 7c).
The use of AMPs in dentistry and medicine has been increasing in the last few decades due to the dynamic combating outcomes. In the past, extensive literature reported on the role of histatins, cathelicidins, and oral defensins peptides in dentistry such as dental implants coatings, and in periodontal tissue regeneration, reducing dental caries and remineralization of dental hard tissue [265,266,267]. Solid-phase peptide synthesis (SPPS) and recombinant DNA technology have been used to encounter the need for AMPs [268,269]. It has been observed by the coating of AMPs on the dental implant surface that it can actively reduce bacterial infection during the healing period.
The most common dental implant materials of titanium, zirconia, polyetheretherketone (PEEK), and polyetherketoneketone (PEKK) are available on the market [26,262]. All these materials have pros and cons according to their chemistry, biomechanics, physics, surface, and esthetic properties [262,270]. In the past, titanium was coated with antibiotics such as cephalothin, amoxicillin, and gentamycin [154] as discussed above. All these approaches can be applied onto three different dental implant surface biofunctionalization levels, as shown in Figure 8 [271]. The use of peptides in combination with the bioactive ingredients has proven to be a promising futuristic coating for the dental implants for better osseointegration, improved implant and soft tissue sealing, and reducing microbial attacks during healing time. A protocol was reported by Rodriguez et al. on the binding of KKLPDA and EEEEEEEE peptides on the Ti6Al4V and hydroxyapatite surfaces for reducing the bacterial infection, as well as bringing a new drug delivery system for the orthopedic and dental implant surface functionalization [59].
Another study reported on the biomodification of new zirconia-based implants with short-motif arginylglycylaspartic acid oligopeptides tailored on the surface and observed rapid osseointegration and improved peri-mucosal sealing, and AMPs reduced the chance of peri-implant infection [272]. With the help of GL13K, a cationic antimicrobial peptide that reduces the Porphyromonas gingivalis growth also inhibits its adhesion [273]. In this in vitro study, the GL13K peptides conjugation onto the titanium microgroove proved the improved antibacterial cytocompatibility and promoted the cell growth in the microgrooves [273]. In the in vitro study against the two oral stains of Streptococcus sanguinis and Lactobacillus salivarius with the titanium surface immobilized with the lactoferrin-derived hLf1-11 antibacterial peptide, it showed an outstanding reduction in the bacterial growth [274]. With the help of human lactoferrin-derived (hLf1-11) peptide, bacterial adhesion on the Ti surface was reduced, inhibited the formation of biofilm, and showed good compatibility with the human fibroblast [275]. Oral defensins peptides are another family member of AMPs found in the oral cavity. The six short motifs of defensins peptides were synthesized by SPPS and characterized against Streptococcus epidermidis and Pseudomonas aeruginosa [276]. In this study, DLAMP-3 (CRVRGGRCA) showed inhibitory effects against the S. epidermidis at 4.37 mg/mL. This DLAMP-3 showed an effect against P. aeruginosa at 35 mg/mL [276]. Human beta defensins peptides have an immuno-modulatory effect that promotes bone remodeling [267]. Similarly, Righino et al. reported the new approach for mimicking human antiviral salivary proline-rich peptide (PRP) for medical purposes [277]. Warnke et al. reported a recombinant human beta defensin-2 coating for biocompatibility assessment with the human mesenchymal stem cells (hMSCs) and human osteoblasts, and found no toxicity [278]. Bifunctional peptide binding (BPB) on the titanium discs were engineered in this study to combat the S. mutans bacteria, and the results were promising for the coating on dental implants due to antibacterial and antibiofouling activity over the four fouling/cleaning cycles [279]. Human saliva contains many antimicrobial proteins and peptides (defensins, cathelicidins, histatins, statherins, and proline-rich peptides), which are useful for oral health. In the previous discussion, we found that most of them are synthetically engineered and bonded to orthopedic and dental implant surface modifications [264].

7.5. Bisphosphonates Coatings

Bisphosphonates drugs are used to treat patients with resorptive bone disorders including hypercalcemia, osteoporosis, multiple myeloma, and Paget’s disease [280]. Commonly used bisphosphonate drugs (alendronate, etidronate, tiludronate, and zolendronate) act by stimulating osteoblasts and bone formation [281], as well as by inhibiting the osteoclastic activity and bone resorption [282]. In patients suffering from the resorptive bone disorders (such as osteoporosis), the altered metabolism and quality of bone may compromise the implant–bone interface and osseointegration [283,284]. Although bisphosphonate therapy may improve the bone metabolism, the long-term systemic administration may lead to bisphosphonate-related osteonecrosis of the jaws (BRONJ) [285] that can be prevented by localized delivery of such drugs. The localized application of bisphosphonates showed promising results for a range of conditions affecting the jaw bone specifically; for instance, improved periodontal healing following mechanical debridement [286], regeneration of the alveolar ridge following extraction [287], and prevention of root resorption [288,289]. Localized bisphosphonates delivery around dental implants reduced the postoperative marginal bone loss and improved the osseointegration [57,290].
A recent systematic review by Najeeb et al. [50] comprehensively analyzed the bisphosphonate-releasing dental implant in terms of osseointegration and advocated the positive effects on dental implant osseointegration. It was further reported that various bisphosphonate drugs (alendronate, pamidronate, and ibandronate) investigated for implant coatings in combination with other compounds (collagen, calcium phosphate, and chondroitin sulphate) showed a significant improvement in the bone formation [50]. Considering the promising benefits of bisphosphonate-coated dental implants, various researchers have further investigated the use of a variety of coating techniques and compositional variables [204,291,292]. For example, plasma spraying was used to apply biomimetic coatings of calcium phosphates and hydroxyapatite combined with bisphosphonates [291,292]. Similarly, techniques such as heat treatment, anodization [293], and immobilization on a porous surface [294] have been used to coat the Ti implants. Additional surface treatments such as surface anodization enhances surface porosity and the area of titania, hence facilitating the loading and delivery of coated bisphosphonates to the bone [20,293,294]. Similarly, using fibrinogen, an intermediate layer between the Ti implant and bisphosphonate coating may enhance the osseointegration [280]. Although, the clinical studies by Abtahi et al. [57,280] reported a reduction in the marginal bone loss while using the bisphosphonate-coated implants when patients were followed-up for a short period of time.
Currently, there is no consensus in terms of dosage and release of drugs from the bisphosphonate coatings. Increased bisphosphonates release (from 8 to 80 µg/mL) in an animal study promoted bone formation; however, no remarkable effects were observed on bone–implant contact [292]. By contrast, Abtahi et al. [57,280] used a bisphosphonate concentration (less than 1 µg/cm2), but the effects of varying dose or concentration on human subjects were not investigated. Although, the preliminary and experimental research has shown promising results in terms of new bone formation and osseointegration around bisphosphonate-coated dental implants. However, information regarding the long-term prognosis and effects of variables such as drug concentration is scarce. The systemic and localized effects of bisphosphonate release on peri-implant tissues have not been addressed adequately. Therefore, further clinical trials with a longer follow-up period are essential to validate the current evidence and clinical efficacy for using the bisphosphonate-coated dental implants.

7.6. Zirconia Coatings

In 1789, a German chemist, Martin Klaproth, discovered zirconium dioxide (ZrO2) during analysis of the mineral zircon (ZrSiO4). However, it was Swedish chemist, Jöns Jacob Berzelius, who isolated the zirconium/zirconia (Zr/ZrO2) in the pure form in 1914 [295,296]. There are three crystalline phases of ZrO2 (monoclinic, cubic, and tetragonal phases). The tetragonal phase is used for dental applications. However, in later years, due to research efforts, a combination of Zr-yttria was developed and named yttria-stabilized tetragonal ZrO2 polycrystals (Y-TZP) [297]. This was made available for usage and was considered the material of choice for hip implants in the late 1990s [296,298]. Use of ZrO2 as a biomaterial in orthopedics first started in 1984, mainly in the United States and Australia. This rapid shift toward Y-TZP in the late 1980s and 1990s was due to a much better strength and lower grain size, resulting in better wear properties and technical advantages in terms of sintering [299].
Today, due to excellent esthetics, biocompatibility, and physical properties, Y-TZP became the material of choice for all-ceramic-material indirect dental restorations [298,300]. Its use in dentistry started in the 1990s first for root canal posts and later for prosthetic abutments. The development of its use in the dental prosthetics started with the opportunity for manufacturing ceramic posterior-fixed partial prostheses [301] followed by its use as an intraosseous dental implant in late 1990s [302]. During the last decade, ZrO2 dental implants have emerged as a viable alternative to Ti dental implants due to its potential osseointegration and bioinert properties, in addition to its esthetic superiority [303,304,305]. Its radiopacity is similar to that of Ti and can be visualized radiographically [306]. Other advantages of ZrO2 over Ti are less bacterial colonization on ZrO2 and the absence of corrosion as Ti is reported to produce corrosion products at the site of dental implants [307,308].
Zirconia is known for excellent mechanical and physical properties [309]. Apart from superiority in the physical properties, research studies show better performance for ZrO2 implants over the Ti implants in terms of biocompatibility due to the non-release of ions and creation of an excellent osteoblast attachment and cellular proliferation that are essential for fast growth of the bone around the implant surface [308,310]. By contrast, Ti implants compromise cell viability, inducing apoptosis, with a decrease in active osteoblasts and compromising the quality of bone [311]. Evaluation of periodontal integration showed improved adhesion of fibroblasts on the ZrO2 surface and stronger attachment, respectively [312,313]. Despite possessing several advantages, current literature reported a limited number of long-term studies involving ZrO2 implants [29]. To date, although the Ti dental implant is still considered the gold standard for dental implant applications, some studies have reported allergic reactions related to Ti [314]. Besides, the generation of galvanic effects after contacting saliva intraorally [308] and wear particles leading to inflammatory responses are also reported due to Ti implants [315]. Therefore, more clinical studies are required to further explore the potential of ZrO2 implants without having adverse reactions [19]. In order to combine the advantages of both the commonly used dental implant materials, i.e., ZrO2 and Ti, a combination of Ti implants coated with ZrO2 particles seems a viable option to explore [19].
The quality of osseointegration mainly depends on the surface properties of dental implants [316]. It is logical to combine the superior osseointegration, biosecurity, and esthetic abilities of ZrO2 with the better fracture resistance of Ti [317]. A number of surface modifications to improve the surface chemistry/topography of coated ZrO2 interacting with biological tissues were studied. Mainly, these can be classified into three groups of physical (e.g., plasma spraying), chemical (acid etching), and biological (e.g., protein absorption) [124,317]. The methods used successfully for the surface modifications on Ti with ZrO2 includes sandblasting with or without acid etching (SLA), dip-coating, and plasma spraying [311,318]. Among these methods, plasma-sprayed coating can be considered a powerful tool due to the significant improvements in the physical/chemical properties of substrate materials. In addition, by manipulation of some parameters, the physical properties such as surface topography, roughness, porosity, and crystallization can be controlled [319,320].
In a recent study, Huang et al. [321] compared the plasma-sprayed nanostructured ZrO2-coated Ti implants and reported the superior osseointegration of plasma-sprayed ZrO2 implant coatings in all quantified parameters [321]. They also claimed an increased number of osteoblastic attachments on ZrO2-coated implants in the early stages. After two weeks, the histological analysis revealed increased osteoblasts attached on the ZrO2-coated implants, and this was further confirmed by micro-CT images, which showed an abundance of bone formation around the ZrO2-coated implants. The plasma-sprayed ZrO2 coating produces an ordered microscale surface layer that improved the osteoblastic attachment, proliferation, and differentiation [322]. These results validated the theory that a higher free-energy surface promotes the attachment of osteoblasts [323]. The difference in the osseointegration between the Zr-coated Ti implants and the Ti implants decreased at four weeks, whereas, at 12 weeks, an almost similar bone trabeculae thickness, a space indicating similar trabeculae arrangement, and the quality of bone were found [324]. The initial and better osseointegration exhibited by the Zr implants and similar osseointegration to that of Ti implants later in the healing period are reported in several research studies [310,322,323,324,325,326]. Though this finding may be non-significant in terms of final osseointegration outcome, the initial rapid and fast osseointegration shown by the Zr-coated implants can be useful in some clinical scenarios to achieve improved stability of the implants to enhance the osseointegration and prognosis [327,328]. Plasma-sprayed nanostructured Zr-coated Ti implants emerged as a promising alternative to commercially pure Ti implants, due to excellent biocompatibility, better esthetics, soft-tissue response, increased osteoblastic activity, and osseointegration at the early stages of healing. Further studies in different clinical scenarios at longer follow-up times are mandatory to validate these findings.

8. Limitations and Future Challenges for Coated Dental Implants

In the recent decades, although plenty of research studies have investigated various coating materials, drugs, and techniques, there are currently very few coated dental implants available for clinical applications. In order to translate implant coatings for clinical applications and to obtain benefits from the controlled targeted therapeutic release, additional clinical studies overcoming various obstacles are a prerequisite. Clinical failure of dental implants is still observed despite the promising outcomes from the outgoing research [118,329,330]. The peri-implant infections and malfunction of the bioactive surface coating are associated with implant failure [329,330]. For example, poorly bonded or undermined coatings may chip off under the mechanical stress of screwing or may laminate prematurely, resulting in an inadequate osseointegration and failure of dental implants [121]. Generally, mechanical properties (such as modulus, tensile, and fatigue strength) of coating materials are remarkably weaker compared to the underlying metal or alloy [331]. The poor mechanical characteristics of therapeutic coating materials resulted in the formation of surface microcracks, leading to fracture and failure [332]. Considering the complex dynamic stresses applied at the implant surface following fixation, further improvements in the mechanical properties of implant coatings are essential for long-term clinical success.
Plasma spraying is commonly used to coat HA on the implant surface [123,333,334,335]. However, there are certain limitations such as a thicker coating (few microns) and the need of substrate surface pretreatment such as grit blasting [121]. In addition, unfavorable porosity, crystallinity, and residual stresses at the implant–CaP coating interface remained the main concerns [331]. In the clinical prospects, the most important is delamination, that is, failure of the coating layer at the interface due to poor bond strength and residual stresses at the implant–CaP coating interface. Such delamination and release of coating particles may lead to implant failure [336,337]. The shortcomings of plasma-sprayed coatings can be overcome using simulated body fluid biomimetic biomineralization approaches to deposit a layer of CaP apatite [121]. In addition, a roughened substrate surface as a result of surface treatment enhanced the mechanical stability of the CaP coatings. Therefore, the coating–implant interface bond strength and mechanical properties are crucial, and there is need of future research to improve these properties.
The biocompatibility of coated dental implants needs special attention as current literature reporting long-term clinical studies about the biocompatibility of therapeutic coated implants is scarce. During the active release of drug molecules by diffusion or osmatic pressure, the coating matrix degrades [68]. The coating material and its dissolved agents and byproducts must be biocompatible to prevent any localized or systemic toxic effects. Although the main purpose of the drug-eluting coating is to permit an effective and reliable supply of the drug to the target site for an anticipated therapeutic effect, it is not a straightforward phenomenon. Nonetheless, controlling the drug release involves a number of factors including the materials’ chemical interaction and physical properties such as dissolution, diffusion, erosion, and osmosis [70,71,72]. The initial burst release of the drug upon implantation leads to poor control over drug elution kinetics and also compromises the sustained release required to achieve the therapeutic effects for a longer time. Therefore, it is important to control the drug release rate; drug elution at a faster rate may have unwanted toxic effects, while a slower release rate compromises the therapeutic efficacy. Significant research including in vitro experiments, animal models, and clinical studies has been conducted with promising outcomes; yet, the aforementioned limitations are the main obstacles for translating various coated implants from the laboratory bench to the market. Currently, a number of researchers are focusing on addressing the limitations and improving the properties of implant coatings. As a result, more therapeutic coated dental implants are expected to be available for clinical applications in the near future.

9. Conclusions and Future Trends

The present article reviewed various aspects of therapeutic surface coatings on dental implants from the perspectives of materials, coatings, drug release, and related beneficial effects. Various types of eluting implant coatings targeted to improve the surface properties, implant–bone interface, and osseointegration were reviewed. Currently, scientists are actively exploring the preclinical characteristics of a variety of medicaments, and inorganics and organic biomolecules including peptides and growth. Available data have indicated that the therapeutic coatings on dental implants effectively improved the surface properties and implant–bone interface by delivering various drug molecules or bioactive components locally without exerting any systemic side effects. Furthermore, the bioactive implant coating strategies clearly suggested the improvement in the osseointegration by mimicking bone remodeling characteristics at the submicron/nanoscale level and enhancing osteoblasts differentiation and bone regeneration. In addition, bioactive materials, bisphosphonates, and antibacterial and antimicrobial implant coatings effectively achieved the respective therapeutic actions. However, only a few of the coated implants are commercially available, while the majority of therapeutic coated dental implant research is at preclinical stage. Although plenty of in vitro and animal studies have been conducted to explore a variety of coating materials, drugs, and techniques, an inadequate number of clinical studies have investigated the long-term performance of coated implants under the complex dynamic conditions of the oral cavity. Future research should focus on bridging the gap between current evidence and clinical applications. To this end, additional clinical studies involving longer follow-up are essential. Additionally, extensive supplemental research is required to address the limitation of the coated implants, such as the poor coating–implant bonds; related mechanical properties need gross improvement to avoid chipping and biocompatibility issues; and biodegradation products should be focused on in the clinical settings. In terms of drug release kinetics, the controlled release of active biomolecules maintaining the required drug concentration for an optimal period of time at the target site is challenging and requires further investigations. Further developments and translating various coated dental implants to clinical applications have vital significance as the demand of dental implants is increasing sharply due to multiple factors such as population growth, increased life expectancy (aging population), and improved quality of life. In the coming decade, we hope that more therapeutic coated dental implants with improved physical/chemical/mechanical properties, biocompatibility, and controlled drug release will be available at a lower cost for clinical use and to benefit the enormous number of dental patients.

Funding

This research received no external funding.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Mijiritsky, E.; Mazor, Z.; Lorean, A.; Levin, L. Implant diameter and length influence on survival: Interim results during the first 2 years of function of implants by a single manufacturer. Implant Dent. 2013, 22, 394–398. [Google Scholar] [CrossRef] [Green Version]
  2. Sullivan, R.M. Implant dentistry and the concept of osseointegration: A historical perspective. J. Calif. Dent. Assoc. 2001, 29, 737–745. [Google Scholar]
  3. Oshida, Y.; Tuna, E.B.; Aktören, O.; Gençay, K. Dental implant systems. Int. J. Mol. Sci. 2010, 11, 1580–1678. [Google Scholar] [CrossRef] [Green Version]
  4. Gaviria, L.; Salcido, J.P.; Guda, T.; Ong, J.L. Current trends in dental implants. J. Korean Assoc. Oral Maxillofac. Surg. 2014, 40, 50–60. [Google Scholar] [CrossRef]
  5. Ng, D.Y.; Wong, A.Y.C.; Liston, P.N. Multidisciplinary approach to implants: A review. N. Z. Dent. J. 2012, 108, 123–128. [Google Scholar]
  6. Misch, C.E. Dental Implant Prosthetics; Elsevier Health Sciences: Amsterdam, The Netherlands, 2004. [Google Scholar]
  7. Babbush, C.A. Dental Implants: Principles and Practice; WB Saunders Company: Philadelphia, PA, USA, 1991. [Google Scholar]
  8. Albrektsson, T.; Zarb, G.; Worthington, P.; Eriksson, A.R. The long-term efficacy of currently used dental implants: A review and proposed criteria of success. Int. J. Oral Maxillofac. Implant. 1986, 1, 11–25. [Google Scholar]
  9. Esposito, M.; Ardebili, Y.; Worthington, H.V. Interventions for replacing missing teeth: Different types of dental implants. Cochrane Database Syst. Rev. 2014, CD003815, 1–93. [Google Scholar] [CrossRef]
  10. AlHelal, A.; AlBader, B.; Kattadiyil, M.T.; Garbacea, A.; Proussaefs, P. CAD-CAM implant-supported fixed complete dental prosthesis with titanium milled molars: A clinical report. J. Prosthet. Dent. 2017, 117, 463–469. [Google Scholar] [CrossRef]
  11. Konstantinidis, I.K.; Jacoby, S.; Rädel, M.; Böning, K. Prospective evaluation of zirconia based tooth-and implant-supported fixed dental prostheses: 3-year results. J. Dent. 2015, 43, 87–93. [Google Scholar] [CrossRef]
  12. Ekfeldt, A.; Zellmer, M.; Carlsson, G.E. Treatment with implant-supported fixed dental prostheses in patients with congenital and acquired neurologic disabilities: A prospective study. Int. J. Prosthodont. 2013, 26, 517–524. [Google Scholar] [CrossRef] [Green Version]
  13. Ibrahim, W.I.; ElKhadem, A.H.; Alqutaibi, A.Y.; Kaddah, A.F. Prosthodontic Maintenance of Fixed Implant Restorations vs. Implant Overdentures: A Systematic Review. Indian J. Sci. Technol. 2016, 9, 1–16. [Google Scholar] [CrossRef] [Green Version]
  14. Albrektsson, T.; Brånemark, P.; Hansson, H.; Lindström, J. Osseointegrated titanium implants: Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man. Acta Orthop. 1981, 52, 155–170. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  15. Albrektsson, T.; Johansson, C. Osteoinduction, osteoconduction and osseointegration. Eur. Spine J. 2001, 10, S96–S101. [Google Scholar] [PubMed] [Green Version]
  16. Bressan, E.; Sbricoli, L.; Guazzo, R.; Tocco, I.; Roman, M.; Vindigni, V.; Stellini, E.; Gardin, C.; Ferroni, L.; Sivolella, S. Nanostructured surfaces of dental implants. Int. J. Mol. Sci. 2013, 14, 1918–1931. [Google Scholar] [CrossRef] [Green Version]
  17. Najeeb, S.; Khurshid, Z.; Zohaib, S.; Zafar, M.S. Bioactivity and osseointegration of PEEK are inferior to those of titanium—A systematic review. J. Oral Implantol. 2016, 42, 512–516. [Google Scholar] [CrossRef]
  18. Geurs, N.C.; Jeffcoat, R.L.; McGlumphy, E.A.; Reddy, M.S.; Jeffcoat, M.K. Influence of implant geometry and surface characteristics on progressive osseointegration. Int. J. Oral Maxillofac. Implant. 2002, 17, 811–815. [Google Scholar]
  19. Osman, R.B.; Swain, M.V. A critical review of dental implant materials with an emphasis on titanium versus zirconia. Materials 2015, 8, 932–958. [Google Scholar] [CrossRef] [Green Version]
  20. Nepal, M.; Li, L.; Bae, T.S.; Kim, B.I.; Soh, Y. Evaluation of Osseointegration around Tibial Implants in Rats by Ibandronate-Treated Nanotubular Ti-32Nb-5Zr Alloy. Biomol. Ther. 2014, 22, 563–569. [Google Scholar] [CrossRef] [Green Version]
  21. Vidigal, G.M.; Groisman, M.; Gregório, L.H.; Soares, G.d.A. Osseointegration of titanium alloy and HA-coated implants in healthy and ovariectomized animals: A histomorphometric study. Clin. Oral Implant. Res. 2009, 20, 1272–1277. [Google Scholar] [CrossRef]
  22. Chaturvedi, T.P. An overview of the corrosion aspect of dental implants (titanium and its alloys). Indian J. Dent. Res. 2009, 20, 91–98. [Google Scholar] [CrossRef]
  23. McCracken, M. Dental implant materials: Commercially pure titanium and titanium alloys. J. Prosthodont. 1999, 8, 40–43. [Google Scholar] [CrossRef] [PubMed]
  24. Rabiei, A.; Sandukas, S. Processing and evaluation of bioactive coatings on polymeric implants. J. Biomed. Mater. Res. Part A 2013, 101, 2621–2629. [Google Scholar] [CrossRef] [PubMed]
  25. Koutouzis, T.; Richardson, J.; Lundgren, T. Comparative soft and hard tissue responses to titanium and polymer healing abutments. J. Oral Implantol. 2011, 37, 174–182. [Google Scholar] [CrossRef] [PubMed]
  26. Najeeb, S.; Zafar, M.S.; Khurshid, Z.; Siddiqui, F. Applications of polyetheretherketone (PEEK) in oral implantology and prosthodontics. J. Prosthodont. Res. 2016, 60, 12–19. [Google Scholar] [CrossRef] [PubMed]
  27. Poulsson, A.H.; Eglin, D.; Zeiter, S.; Camenisch, K.; Sprecher, C.; Agarwal, Y.; Nehrbass, D.; Wilson, J.; Richards, R.G. Osseointegration of machined, injection moulded and oxygen plasma modified PEEK implants in a sheep model. Biomaterials 2014, 35, 3717–3728. [Google Scholar] [CrossRef]
  28. Schwitalla, A.; Müller, W. PEEK dental implants: A review of the literature. J. Oral Implantol. 2013, 39, 743–749. [Google Scholar] [CrossRef]
  29. Hashim, D.; Cionca, N.; Courvoisier, D.S.; Mombelli, A. A systematic review of the clinical survival of zirconia implants. Clin. Oral Investig. 2016, 20, 1403–1417. [Google Scholar] [CrossRef] [Green Version]
  30. Özkurt, Z.; Kazazoğlu, E. Zirconia dental implants: A literature review. J. Oral Implantol. 2011, 37, 367–376. [Google Scholar] [CrossRef]
  31. Stübinger, S.; Homann, F.; Etter, C.; Miskiewicz, M.; Wieland, M.; Sader, R. Effect of Er: YAG, CO2 and diode laser irradiation on surface properties of zirconia endosseous dental implants. Lasers Surg. Med. 2008, 40, 223–228. [Google Scholar] [CrossRef]
  32. Badran, Z.; Struillou, X.; Hughes, F.J.; Soueidan, A.; Hoornaert, A.; Ide, M. Silicon Nitride (Si3N4) Implants: The Future of Dental Implantology? J. Oral Implantol. 2017, 43, 240–244. [Google Scholar] [CrossRef] [Green Version]
  33. Webster, T.J.; Patel, A.A.; Rahaman, M.; Bal, B.S. Anti-infective and osteointegration properties of silicon nitride, poly (ether ether ketone), and titanium implants. Acta Biomater. 2012, 8, 4447–4454. [Google Scholar] [CrossRef]
  34. Elias, C.N.; Fernandes, D.J.; Resende, C.R.; Roestel, J. Mechanical properties, surface morphology and stability of a modified commercially pure high strength titanium alloy for dental implants. Dent. Mater. 2015, 31, e1–e13. [Google Scholar] [CrossRef] [PubMed]
  35. Elias, C.N.; Fernandes, D.J.; de Souza, F.M.; dos Santos Monteiro, E.; de Biasi, R.S. Mechanical and clinical properties of titanium and titanium-based alloys (Ti G2, Ti G4 cold worked nanostructured and Ti G5) for biomedical applications. J. Mater. Res. Technol. 2019, 8, 1060–1069. [Google Scholar] [CrossRef]
  36. Bauer, S.; Schmuki, P.; von der Mark, K.; Park, J. Engineering biocompatible implant surfaces: Part I: Materials and surfaces. Prog. Mater. Sci. 2013, 58, 261–326. [Google Scholar] [CrossRef]
  37. Rupp, F.; Liang, L.; Geis-Gerstorfer, J.; Scheideler, L.; Hüttig, F. Surface characteristics of dental implants: A review. Dent. Mater. 2018, 34, 40–57. [Google Scholar] [CrossRef]
  38. Triplett, R.G.; Frohberg, U.; Sykaras, N.; Woody, R.D. Implant materials, design, and surface topographies: Their influence on osseointegration of dental implants. J. Long. Term. Eff. Med. 2003, 13, 485–502. [Google Scholar] [CrossRef]
  39. Sykaras, N.; Iacopino, A.M.; Marker, V.A.; Triplett, R.G.; Woody, R.D. Implant materials, designs, and surface topographies: Their effect on osseointegration. A literature review. Int. J. Oral Maxillofac. Implant. 2000, 15, 675–690. [Google Scholar]
  40. Gepreel, M.A.; Niinomi, M. Biocompatibility of Ti-alloys for long-term implantation. J. Mech. Behav. Biomed. Mater. 2013, 20, 407–415. [Google Scholar] [CrossRef]
  41. Niinomi, M. Mechanical properties of biomedical titanium alloys. Mater. Sci. Eng. A 1998, 243, 231–236. [Google Scholar] [CrossRef]
  42. Sumitomo, N.; Noritake, K.; Hattori, T.; Morikawa, K.; Niwa, S.; Sato, K.; Niinomi, M. Experiment study on fracture fixation with low rigidity titanium alloy. J. Mater. Sci. Mater. Med. 2008, 19, 1581–1586. [Google Scholar] [CrossRef]
  43. Niinomi, M.; Nakai, M. Titanium-Based Biomaterials for Preventing Stress Shielding between Implant Devices and Bone. Int. J. Biomater. 2011, 2011, 836587. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  44. Bosco, R.; Van Den Beucken, J.; Leeuwenburgh, S.; Jansen, J. Surface engineering for bone implants: A trend from passive to active surfaces. Coatings 2012, 2, 95–119. [Google Scholar] [CrossRef] [Green Version]
  45. Suzuki, M.; Guimaraes, M.V.M.; Marin, C.; Granato, R.; Gil, J.N.; Coelho, P.G. Histomorphometric Evaluation of Alumina-Blasted/Acid-Etched and Thin Ion Beam-Deposited Bioceramic Surfaces: An Experimental Study in Dogs. J. Oral Maxillofac. Surg. 2009, 67, 602–607. [Google Scholar] [CrossRef] [PubMed]
  46. Wennerberg, A. The importance of surface roughness for implant incorporation. Int. J. Mach. Tools Manuf. 1998, 38, 657–662. [Google Scholar] [CrossRef]
  47. Elias, C.N.; Meirelles, L. Improving osseointegration of dental implants. Expert Rev. Med Devices 2010, 7, 241–256. [Google Scholar] [CrossRef]
  48. Zafar, M.S.; Farooq, I.; Awais, M.; Najeeb, S.; Khurshid, Z.; Zohaib, S. Chapter 11-Bioactive Surface Coatings for Enhancing Osseointegration of Dental Implants. Biomed. Ther. Clin. Appl. Bioact. Glasses 2019, 313–329. [Google Scholar] [CrossRef]
  49. Kulkarni Aranya, A.; Pushalkar, S.; Zhao, M.; LeGeros, R.Z.; Zhang, Y.; Saxena, D. Antibacterial and bioactive coatings on titanium implant surfaces. J. Biomed. Mater. Res. Part A 2017. [Google Scholar] [CrossRef] [Green Version]
  50. Najeeb, S.; Zafar, M.S.; Khurshid, Z.; Zohaib, S.; Hasan, S.M.; Khan, R.S. Bisphosphonate releasing dental implant surface coatings and osseointegration: A systematic review. J. Taibah Univ. Med. Sci. 2017, 12, 369–375. [Google Scholar] [CrossRef]
  51. Ballo, A.M.; Akca, E.; Ozen, T.; Moritz, N.; Lassila, L.; Vallittu, P.; Närhi, T. Effect of implant design and bioactive glass coating on biomechanical properties of fiber-reinforced composite implants. Eur. J. Oral Sci. 2014, 122, 303–309. [Google Scholar] [CrossRef]
  52. Barkarmo, S.; Wennerberg, A.; Hoffman, M.; Kjellin, P.; Breding, K.; Handa, P.; Stenport, V. Nano-hydroxyapatite-coated PEEK implants: A pilot study in rabbit bone. J. Biomed. Mater. Res. Part A 2013, 101, 465–471. [Google Scholar] [CrossRef]
  53. Mehdikhani-Nahrkhalaji, M.; Fathi, M.; Mortazavi, V.; Mousavi, S.; Hashemi-Beni, B.; Razavi, S. Novel nanocomposite coating for dental implant applications in vitro and in vivo evaluation. J. Mater. Sci. Mater. Med. 2012, 23, 1–11. [Google Scholar] [CrossRef] [PubMed]
  54. Palmquist, A.; Omar, O.M.; Esposito, M.; Lausmaa, J.; Thomsen, P. Titanium oral implants: Surface characteristics, interface biology and clinical outcome. J. R. Soc. Interface 2010, 7, S515–S527. [Google Scholar] [CrossRef] [PubMed]
  55. Kettenberger, U.; Luginbuehl, V.; Procter, P.; Pioletti, D.P. In vitro and in vivo investigation of bisphosphonate-loaded hydroxyapatite particles for peri-implant bone augmentation. J. Tissue Eng. Regen. Med. 2017, 11, 1974–1985. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  56. Alghamdi, H.S.; Bosco, R.; Both, S.K.; Iafisco, M.; Leeuwenburgh, S.C.; Jansen, J.A.; van den Beucken, J.J. Synergistic effects of bisphosphonate and calcium phosphate nanoparticles on peri-implant bone responses in osteoporotic rats. Biomaterials 2014, 35, 5482–5490. [Google Scholar] [CrossRef]
  57. Abtahi, J.; Tengvall, P.; Aspenberg, P. A bisphosphonate-coating improves the fixation of metal implants in human bone. A randomized trial of dental implants. Bone 2012, 50, 1148–1151. [Google Scholar] [CrossRef] [Green Version]
  58. Norowski, P.A.; Courtney, H.S.; Babu, J.; Haggard, W.O.; Bumgardner, J.D. Chitosan coatings deliver antimicrobials from titanium implants: A preliminary study. Implant Dent. 2011, 20, 56–67. [Google Scholar] [CrossRef]
  59. Rodriguez, G.M.; Bowen, J.; Grossin, D.; Ben-Nissan, B.; Stamboulis, A. Functionalisation of Ti6Al4V and hydroxyapatite surfaces with combined peptides based on KKLPDA and EEEEEEEE peptides. Colloids Surf. B Biointerfaces 2017, 160, 154–160. [Google Scholar] [CrossRef]
  60. Grischke, J.; Eberhard, J.; Stiesch, M. Antimicrobial dental implant functionalization strategies—A systematic review. Dent. Mater. J. 2016, 35, 545–558. [Google Scholar] [CrossRef] [Green Version]
  61. Alves, D.; Olívia Pereira, M. Mini-review: Antimicrobial peptides and enzymes as promising candidates to functionalize biomaterial surfaces. Biofouling 2014, 30, 483–499. [Google Scholar] [CrossRef]
  62. Stewart, S.A.; Domínguez-Robles, J.; Donnelly, R.F.; Larrañeta, E. Implantable polymeric drug delivery devices: Classification, manufacture, materials, and clinical applications. Polymers 2018, 10, 1379. [Google Scholar] [CrossRef] [Green Version]
  63. Stevenson, C.L.; Santini, J.T.; Langer, R. Reservoir-based drug delivery systems utilizing microtechnology. Adv. Drug Deliv. Rev. 2012, 64, 1590–1602. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  64. Liang, J.; Peng, X.; Zhou, X.; Zou, J.; Cheng, L. Emerging Applications of Drug Delivery Systems in Oral Infectious Diseases Prevention and Treatment. Molecules 2020, 25, 516. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  65. Ibekwe, V.C.; Fadda, H.M.; Parsons, G.E.; Basit, A.W. A comparative in vitro assessment of the drug release performance of pH-responsive polymers for ileo-colonic delivery. Int. J. Pharm. 2006, 308, 52–60. [Google Scholar] [CrossRef] [PubMed]
  66. Pan, C.; Zhou, Z.; Yu, X. Coatings as the useful drug delivery system for the prevention of implant-related infections. J. Orthop. Surg. Res. 2018, 13, 1–11. [Google Scholar] [CrossRef] [Green Version]
  67. Langer, R. New methods of drug delivery. Science 1990, 249, 1527–1533. [Google Scholar] [CrossRef]
  68. Gultepe, E.; Nagesha, D.; Sridhar, S.; Amiji, M. Nanoporous inorganic membranes or coatings for sustained drug delivery in implantable devices. Adv. Drug Deliv. Rev. 2010, 62, 305–315. [Google Scholar] [CrossRef]
  69. Son, G.; Lee, B.; Cho, C. Mechanisms of drug release from advanced drug formulations such as polymeric-based drug-delivery systems and lipid nanoparticles. J. Pharm. Investig. 2017, 47, 287–296. [Google Scholar] [CrossRef]
  70. Siepmann, J.; Peppas, N.A. Modeling of drug release from delivery systems based on hydroxypropyl methylcellulose (HPMC). Adv. Drug Deliv. Rev. 2012, 64, 163–174. [Google Scholar] [CrossRef]
  71. Korsmeyer, R.W.; Gurny, R.; Doelker, E.; Buri, P.; Peppas, N.A. Mechanisms of solute release from porous hydrophilic polymers. Int. J. Pharm. 1983, 15, 25–35. [Google Scholar] [CrossRef]
  72. Siepmann, J.; Siepmann, F. Modeling of diffusion controlled drug delivery. J. Control. Release 2012, 161, 351–362. [Google Scholar] [CrossRef]
  73. Costa, P.; Sousa Lobo, J.M. Modeling and comparison of dissolution profiles. Eur. J. Pharm. Sci. 2001, 13, 123–133. [Google Scholar] [CrossRef]
  74. Peppas, N.A.; Narasimhan, B. Mathematical models in drug delivery: How modeling has shaped the way we design new drug delivery systems. J. Control. Release 2014, 190, 75–81. [Google Scholar] [CrossRef] [PubMed]
  75. Siepmann, J.; Siegel, R.A.; Rathbone, M.J. Fundamentals and Applications of Controlled Release Drug Delivery; Springer: Boston, MA, USA, 2012; Volume 3. [Google Scholar]
  76. Exner, A.A.; Saidel, G.M. Drug-eluting polymer implants in cancer therapy. Expert Opin. Drug Deliv. 2008, 5, 775–788. [Google Scholar] [CrossRef]
  77. Wolinsky, J.B.; Colson, Y.L.; Grinstaff, M.W. Local drug delivery strategies for cancer treatment: Gels, nanoparticles, polymeric films, rods, and wafers. J. Control. Release 2012, 159, 14–26. [Google Scholar] [CrossRef] [Green Version]
  78. Mauri, E.; Rossi, F.; Sacchetti, A. Tunable drug delivery using chemoselective functionalization of hydrogels. Mater. Sci. Eng. C 2016, 61, 851–857. [Google Scholar] [CrossRef] [PubMed]
  79. Rossi, F.; Castiglione, F.; Ferro, M.; Moioli, M.; Mele, A.; Masi, M. The role of drug–drug interactions in hydrogel delivery systems: Experimental and model study. ChemPhysChem 2016, 17, 1615–1622. [Google Scholar] [CrossRef]
  80. Reza Saboktakin, M.; Tabatabaei, R.M. Supramolecular hydrogels as drug delivery systems. Int. J. Biol. Macromol. 2015, 75, 426–436. [Google Scholar] [CrossRef]
  81. Aw, M.S.; Gulati, K.; Losic, D. Controlling drug release from titania nanotube arrays using polymer nanocarriers and biopolymer coating. J. Biomater. Nanobiotechnology 2011, 2, 477–484. [Google Scholar] [CrossRef] [Green Version]
  82. Han, C.; Jang, T.; Kim, H.; Koh, Y. Creation of nanoporous TiO2 surface onto polyetheretherketone for effective immobilization and delivery of bone morphogenetic protein. J. Biomed. Mater. Res. Part A 2014, 102, 793–800. [Google Scholar] [CrossRef]
  83. Tibbitt, M.W.; Rodell, C.B.; Burdick, J.A.; Anseth, K.S. Progress in material design for biomedical applications. Proc. Natl. Acad. Sci. USA 2015, 112, 14444–14451. [Google Scholar] [CrossRef] [Green Version]
  84. Kaur, P.; Garg, T.; Rath, G.; Murthy, R.; Goyal, A.K. Surfactant-based drug delivery systems for treating drug-resistant lung cancer. Drug Deliv. 2016, 23, 717–728. [Google Scholar] [CrossRef] [PubMed]
  85. Zelikin, A.N. Drug releasing polymer thin films: New era of surface-mediated drug delivery. ACS Nano 2010, 4, 2494–2509. [Google Scholar] [CrossRef] [PubMed]
  86. Creel, C.J.; Lovich, M.A.; Edelman, E.R. Arterial paclitaxel distribution and deposition. Circ. Res. 2000, 86, 879–884. [Google Scholar] [CrossRef] [Green Version]
  87. Pakulska, M.M.; Donaghue, I.E.; Obermeyer, J.M.; Tuladhar, A.; McLaughlin, C.K.; Shendruk, T.N.; Shoichet, M.S. Encapsulation-free controlled release: Electrostatic adsorption eliminates the need for protein encapsulation in PLGA nanoparticles. Sci. Adv. 2016, 2, e1600519. [Google Scholar] [CrossRef] [Green Version]
  88. Chang, M.; Zhang, F.; Wei, T.; Zuo, T.; Guan, Y.; Lin, G.; Shao, W. Smart linkers in polymer–drug conjugates for tumor-targeted delivery. J. Drug Target. 2016, 24, 475–491. [Google Scholar] [CrossRef]
  89. Kamath, K.R.; Barry, J.J.; Miller, K.M. The Taxus™ drug-eluting stent: A new paradigm in controlled drug delivery. Adv. Drug Deliv. Rev. 2006, 58, 412–436. [Google Scholar] [CrossRef] [PubMed]
  90. Vulic, K.; Shoichet, M.S. Tunable growth factor delivery from injectable hydrogels for tissue engineering. J. Am. Chem. Soc. 2012, 134, 882–885. [Google Scholar] [CrossRef] [PubMed]
  91. Ossipov, D.; Kootala, S.; Yi, Z.; Yang, X.; Hilborn, J. Orthogonal chemoselective assembly of hyaluronic acid networks and nanogels for drug delivery. Macromolecules 2013, 46, 4105–4113. [Google Scholar] [CrossRef]
  92. Rossi, F.; van Griensven, M. Polymer functionalization as a powerful tool to improve scaffold performances. Tissue Eng. Part A 2014, 20, 2043–2051. [Google Scholar] [CrossRef]
  93. Venkatraman, S.; Boey, F. Release profiles in drug-eluting stents: Issues and uncertainties. J. Control. Release 2007, 120, 149–160. [Google Scholar] [CrossRef]
  94. Wang, X.; Venkatraman, S.S.; Boey, F.Y.C.; Loo, J.S.C.; Tan, L.P. Controlled release of sirolimus from a multilayered PLGA stent matrix. Biomaterials 2006, 27, 5588–5595. [Google Scholar] [CrossRef]
  95. Ranade, S.V.; Richard, R.E.; Helmus, M.N. Styrenic block copolymers for biomaterial and drug delivery applications. Acta Biomater. 2005, 1, 137–144. [Google Scholar] [CrossRef] [PubMed]
  96. Shameem, M.; Lee, H.; DeLuca, P.P. A short-term (accelerated release) approach to evaluate peptide release from PLGA depot formulations. AAPS PharmSci 1999, 1, 1. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  97. Miyajima, M.; Koshika, A.; Okada, J.; Ikeda, M. Mechanism of drug release from poly(l-lactic acid) matrix containing acidic or neutral drugs. J. Control. Release 1999, 60, 199–209. [Google Scholar] [CrossRef]
  98. Jonnalagadda, S.; Robinson, D.H. A bioresorbable, polylactide reservoir for diffusional and osmotically controlled drug delivery. AAPS PharmSciTech 2000, 1, 26–34. [Google Scholar] [CrossRef]
  99. Frank, A.; Kumar Rath, S.; Boey, F.; Venkatraman, S. Study of the initial stages of drug release from a degradable matrix of poly(d,l-lactide-co-glycolide). Biomaterials 2004, 25, 813–821. [Google Scholar] [CrossRef]
  100. Hurrell, S.; Cameron, R.E. The effect of initial polymer morphology on the degradation and drug release from polyglycolide. Biomaterials 2002, 23, 2401–2409. [Google Scholar] [CrossRef]
  101. Grassi, M.; Grassi, G. Mathematical modelling and controlled drug delivery: Matrix systems. Curr. Drug Deliv. 2005, 2, 97–116. [Google Scholar] [CrossRef]
  102. Chen, M.; Liang, H.; Chiu, Y.; Chang, Y.; Wei, H.; Sung, H. A novel drug-eluting stent spray-coated with multi-layers of collagen and sirolimus. J. Control. Release 2005, 108, 178–189. [Google Scholar] [CrossRef]
  103. Acharya, G.; Park, K. Mechanisms of controlled drug release from drug-eluting stents. Adv. Drug Deliv. Rev. 2006, 58, 387–401. [Google Scholar] [CrossRef]
  104. Pan, C.J.; Tang, J.J.; Weng, Y.J.; Wang, J.; Huang, N. Preparation, characterization and anticoagulation of curcumin-eluting controlled biodegradable coating stents. J. Control. Release 2006, 116, 42–49. [Google Scholar] [CrossRef] [PubMed]
  105. Sternberg, K.; Kramer, S.; Nischan, C.; Grabow, N.; Langer, T.; Hennighausen, G.; Schmitz, K. In vitro study of drug-eluting stent coatings based on poly (L-lactide) incorporating cyclosporine A–drug release, polymer degradation and mechanical integrity. J. Mater. Sci. Mater. Med. 2007, 18, 1423–1432. [Google Scholar] [CrossRef] [PubMed]
  106. Saylor, D.M.; Kim, C.; Patwardhan, D.V.; Warren, J.A. Modeling microstructure development and release kinetics in controlled drug release coatings. J. Pharm. Sci. 2009, 98, 169–186. [Google Scholar] [CrossRef]
  107. Alexis, F.; Venkatraman, S.S.; Rath, S.K.; Boey, F. In vitro study of release mechanisms of paclitaxel and rapamycin from drug-incorporated biodegradable stent matrices. J. Control. Release 2004, 98, 67–74. [Google Scholar] [CrossRef] [PubMed]
  108. Finkelstein, A.; McClean, D.; Kar, S.; Takizawa, K.; Varghese, K.; Baek, N.; Park, K.; Fishbein, M.C.; Makkar, R.; Litvack, F. Local drug delivery via a coronary stent with programmable release pharmacokinetics. Circulation 2003, 107, 777–784. [Google Scholar] [CrossRef] [Green Version]
  109. Raval, A.; Choubey, A.; Engineer, C.; Kotadia, H.; Kothwala, D. Novel biodegradable polymeric matrix coated cardiovascular stent for controlled drug delivery. Trends Biomater. Artif. Organs 2007, 20, 101–110. [Google Scholar]
  110. Balakrishnan, B.; Dooley, J.F.; Kopia, G.; Edelman, E.R. Intravascular drug release kinetics dictate arterial drug deposition, retention, and distribution. J. Control. Release 2007, 123, 100–108. [Google Scholar] [CrossRef] [Green Version]
  111. Leon, M.; Abizaid, A.; Moses, J. The Cypher Stent: A New Gold Standard in the Treatment of Coronary Artery Disease; The Cardiovascular Research Foundation: New York, NY, USA, 2003. [Google Scholar]
  112. Otsuka, Y.; Chronos, N.A.; Apkarian, R.P.; Robinson, K.A. Scanning electron microscopic analysis of defects in polymer coatings of three commercially available stents: Comparison of BiodivYsio, Taxus and Cypher stents. J. Invasive Cardiol. 2007, 19, 71–76. [Google Scholar]
  113. Rajurkar, R.M.; Rathod, C.P.; Thonte, S.S.; Sugave, R.V.; Sugave, B.K.; Phadtare, A.A.; Bhosale, P.H. Gastroretentive Mucoadhesive Microsphere As Carriers In Drug Delivery: A Review. Indo Am. J. Pharm. Res. 2013, 3, 2751–2777. [Google Scholar]
  114. Albrektsson, T.; Jemt, T.; Mölne, J.; Tengvall, P.; Wennerberg, A. On inflammation-immunological balance theory—A critical apprehension of disease concepts around implants: Mucositis and marginal bone loss may represent normal conditions and not necessarily a state of disease. Clin. Implant Dent. Relat. Res. 2019, 21, 183–189. [Google Scholar] [CrossRef] [Green Version]
  115. Yeo, I.L. Modifications of Dental Implant Surfaces at the Micro- and Nano-Level for Enhanced Osseointegration. Materials 2020, 13, 89. [Google Scholar] [CrossRef] [Green Version]
  116. Lavenus, S.; Rozé, J.; Hoornaert, A.; Louarn, G.; Layrolle, P. Chapter 5-Impact of Nanotechnology on Dental Implants. Emerg. Nanotechnol. Dent. 2012, 71–84. [Google Scholar] [CrossRef]
  117. Subramani, K.; Ahmed, W.; Pachauri, P. Chapter 7-Titanium nanotubes as carriers of osteogenic growth factors and antibacterial drugs for applications in dental implantology. Emerg. Nanotechnol. Dent. 2018, 125–136. [Google Scholar] [CrossRef]
  118. Sakka, S.; Coulthard, P. Implant failure: Etiology and complications. Med. Oral Patol. Oral Cir. Bucal 2011, 16, 42–44. [Google Scholar] [CrossRef] [Green Version]
  119. Chen, H.; Liu, N.; Xu, X.; Qu, X.; Lu, E. Smoking, radiotherapy, diabetes and osteoporosis as risk factors for dental implant failure: A meta-analysis. PLoS ONE 2013, 8, e71955. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  120. Baqain, Z.H.; Moqbel, W.Y.; Sawair, F.A. Early dental implant failure: Risk factors. Br. J. Oral Maxillofac. Surg. 2012, 50, 239–243. [Google Scholar] [CrossRef] [PubMed]
  121. Le Guéhennec, L.; Soueidan, A.; Layrolle, P.; Amouriq, Y. Surface treatments of titanium dental implants for rapid osseointegration. Dent. Mater. 2007, 23, 844–854. [Google Scholar] [CrossRef] [PubMed]
  122. Javed, F.; Vohra, F.; Zafar, S.; Almas, K. Significance of Osteogenic Surface Coatings on Implants to Enhance Osseointegration Under Osteoporotic-like Conditions. Implant Dent. 2014, 23, 679–686. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  123. Stewart, M.; Welter, J.F.; Goldberg, V.M. Effect of hydroxyapatite/tricalcium-phosphate coating on osseointegration of plasma-sprayed titanium alloy implants. J. Biomed. Mater. Res. Part A 2004, 69, 1–10. [Google Scholar] [CrossRef]
  124. Alzubaydi, T.L.; AlAmeer, S.S.; Ismaeel, T.; AlHijazi, A.Y.; Geetha, M. In vivo studies of the ceramic coated titanium alloy for enhanced osseointegration in dental applications. J. Mater. Sci. Mater. Med. 2009, 20, 35. [Google Scholar] [CrossRef]
  125. Zafar, M.S.; Al-Samadani, K.H. Potential use of natural silk for bio-dental applications. J. Taibah Univ. Med. Sci. 2014, 9, 171–177. [Google Scholar] [CrossRef] [Green Version]
  126. Matinlinna, J.P.; Tsoi, J.K.; de Vries, J.; Busscher, H.J. Characterization of novel silane coatings on titanium implant surfaces. Clin. Oral Implant. Res. 2013, 24, 688–697. [Google Scholar] [CrossRef]
  127. Bose, S.; Tarafder, S. Calcium phosphate ceramic systems in growth factor and drug delivery for bone tissue engineering: A review. Acta Biomater. 2012, 8, 1401–1421. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  128. Parr, G.R.; Gardner, L.K.; Toth, R.W. Titanium: The mystery metal of implant dentistry. Dental materials aspects. J. Prosthet. Dent. 1985, 54, 410–414. [Google Scholar] [CrossRef]
  129. Smith, D.C. Dental implants: Materials and design considerations. Int. J. Prosthodont. 1993, 6, 106–117. [Google Scholar] [PubMed]
  130. Wilson, C.J.; Clegg, R.E.; Leavesley, D.I.; Pearcy, M.J. Mediation of biomaterial–cell interactions by adsorbed proteins: A review. Tissue Eng. 2005, 11, 1–18. [Google Scholar] [CrossRef] [PubMed]
  131. Rammelt, S.; Illert, T.; Bierbaum, S.; Scharnweber, D.; Zwipp, H.; Schneiders, W. Coating of titanium implants with collagen, RGD peptide and chondroitin sulfate. Biomaterials 2006, 27, 5561–5571. [Google Scholar] [CrossRef]
  132. Bruschi, M.; Steinmüller-Nethl, D.; Goriwoda, W.; Rasse, M. Composition and modifications of dental implant surfaces. J. Oral Implant. 2015, 2015, 1–15. [Google Scholar] [CrossRef] [Green Version]
  133. Steinmüller-Nethl, D.; Kloss, F.R.; Najam-Ul-Haq, M.; Rainer, M.; Larsson, K.; Linsmeier, C.; Köhler, G.; Fehrer, C.; Lepperdinger, G.; Liu, X.; et al. Strong binding of bioactive BMP-2 to nanocrystalline diamond by physisorption. Biomaterials 2006, 27, 4547–4556. [Google Scholar] [CrossRef]
  134. Mistry, S.; Kundu, D.; Datta, S.; Basu, D. Comparison of bioactive glass coated and hydroxyapatite coated titanium dental implants in the human jaw bone. Aust. Dent. J. 2011, 56, 68–75. [Google Scholar] [CrossRef]
  135. Kellesarian, S.V.; Abduljabbar, T.; Vohra, F.; Malignaggi, V.R.; Malmstrom, H.; Romanos, G.E.; Javed, F. Role of local alendronate delivery on the osseointegration of implants: A systematic review and meta-analysis. Int. J. Oral Maxillofac. Surg. 2017, 46, 912–921. [Google Scholar] [CrossRef] [PubMed]
  136. Romanò, C.L.; Scarponi, S.; Gallazzi, E.; Romanò, D.; Drago, L. Antibacterial coating of implants in orthopaedics and trauma: A classification proposal in an evolving panorama. J. Orthop. Surg. Res. 2015, 10, 157. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  137. Bozzini, B.; Barca, A.; Bogani, F.; Boniardi, M.; Carlino, P.; Mele, C.; Verri, T.; Romano, A. Electrodeposition of nanostructured bioactive hydroxyapatite-heparin composite coatings on titanium for dental implant applications. J. Mater. Sci. Mater. Med. 2014, 25, 1425–1434. [Google Scholar] [CrossRef] [PubMed]
  138. Han, Y.; Zeng, Q.; Lingling, E.; Wang, D.; He, H.; Liu, H. Sustained Topical Delivery of Insulin From Fibrin Gel Loaded With Poly(Lactic-Co-Glycolic Acid) Microspheres Improves the Biomechanical Retention of Titanium Implants in Type 1 Diabetic Rats. J. Oral Maxillofac. Surg. 2012, 70, 2299–2308. [Google Scholar] [CrossRef]
  139. Wang, F.; Song, Y.; Li, C.; Li, D.; Zhang, H.; Ma, A.; Xi, X.; Zhang, N.; Wang, B.; Wang, Y.; et al. Sustained release of insulin-like growth factor-1 from poly(lactide-co-glycolide) microspheres improves osseointegration of dental implants in type 2 diabetic rats. Eur. J. Pharmacol. 2010, 640, 226–232. [Google Scholar] [CrossRef]
  140. Hanisch, O.; Sorensen, R.G.; Kinoshita, A.; Spiekermann, H.; Wozney, J.M.; Wikesjö, U.M. Effect of recombinant human bone morphogenetic protein-2 in dehiscence defects with non-submerged immediate implants: An experimental study in Cynomolgus monkeys. J. Periodontol. 2003, 74, 648–657. [Google Scholar] [CrossRef]
  141. Wen, B.; Karl, M.; Pendrys, D.; Shafer, D.; Freilich, M.; Kuhn, L. An evaluation of BMP-2 delivery from scaffolds with miniaturized dental implants in a novel rat mandible model. J. Biomed. Mater. Res. Part B Appl. Biomater. 2011, 97, 315–326. [Google Scholar] [CrossRef]
  142. Jiang, Q.; Liu, L.; Peel, S.; Yang, G.; Zhao, S.; He, F. Bone response to the multilayer BMP-2 gene coated porous titanium implant surface. Clin. Oral Implant. Res. 2013, 24, 853–861. [Google Scholar] [CrossRef]
  143. Sykaras, N.; Iacopino, A.M.; Triplett, R.G.; Marker, V.A. Effect of recombinant human bone morphogenetic protein-2 on the osseointegration of dental implants: A biomechanics study. Clin. Oral Investig. 2004, 8, 196–205. [Google Scholar] [CrossRef]
  144. Schuckert, K.; Jopp, S.; Muller, U. De novo grown bone on exposed implant surfaces using photodynamic therapy and recombinant human bone morphogenetic protein-2: Case report. Implant Dent. 2006, 15, 361–365. [Google Scholar] [CrossRef]
  145. Pokrowiecki, R. The paradigm shift for drug delivery systems for oral and maxillofacial implants. Drug Deliv. 2018, 25, 1504–1515. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  146. Huang, T.; Chen, C.; Hung, C.; Kao, C. Comparison of antibacterial activities of root-end filling materials by an agar diffusion assay and Alamar blue assay. J. Dent. Sci. 2012, 7, 336–341. [Google Scholar] [CrossRef] [Green Version]
  147. Morra, M. Biochemical modification of titanium surfaces: Peptides and ECM proteins. Eur. Cell. Mater. 2006, 12, 15. [Google Scholar] [CrossRef] [PubMed]
  148. Giacomino, C.M.; Wealleans, J.A.; Kuhn, N.; Diogenes, A. Comparative Biocompatibility and Osteogenic Potential of Two Bioceramic Sealers. J. Endod. 2019, 45, 51–56. [Google Scholar] [CrossRef] [PubMed]
  149. Gittens, R.A.; McLachlan, T.; Olivares-Navarrete, R.; Cai, Y.; Berner, S.; Tannenbaum, R.; Schwartz, Z.; Sandhage, K.H.; Boyan, B.D. The effects of combined micron-/submicron-scale surface roughness and nanoscale features on cell proliferation and differentiation. Biomaterials 2011, 32, 3395–3403. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  150. Kloss, F.R.; Singh, S.; Hächl, O.; Rentenberger, J.; Auberger, T.; Kraft, A.; Klima, G.; Mitterlechner, T.; Steinmüller-Nethl, D.; Lethaus, B. BMP-2 immobilized on nanocrystalline diamond–coated titanium screws; demonstration of osteoinductive properties in irradiated bone. Head Neck 2013, 35, 235–241. [Google Scholar] [CrossRef]
  151. Liu, Y.; Huse, R.O.; de Groot, K.; Buser, D.; Hunziker, E.B. Delivery mode and efficacy of BMP-2 in association with implants. J. Dent. Res. 2007, 86, 84–89. [Google Scholar] [CrossRef]
  152. Pye, A.; Lockhart, D.; Dawson, M.; Murray, C.; Smith, A. A review of dental implants and infection. J. Hosp. Infect. 2009, 72, 104–110. [Google Scholar] [CrossRef]
  153. Shi, Z.; Neoh, K.; Kang, E.; Poh, C.K.; Wang, W. Surface functionalization of titanium with carboxymethyl chitosan and immobilized bone morphogenetic protein-2 for enhanced osseointegration. Biomacromolecules 2009, 10, 1603–1611. [Google Scholar] [CrossRef]
  154. Zhao, L.; Chu, P.K.; Zhang, Y.; Wu, Z. Antibacterial coatings on titanium implants. J. Biomed. Mater. Res. 2009, 91B, 470–480. [Google Scholar] [CrossRef]
  155. McLean, K.M.; McArthur, S.L.; Chatelier, R.C.; Kingshott, P.; Griesser, H.J. Hybrid biomaterials: Surface-MALDI mass spectrometry analysis of covalent binding versus physisorption of proteins. Colloids Surf. B Biointerfaces 2000, 17, 23–35. [Google Scholar] [CrossRef]
  156. De Giglio, E.; De Gennaro, L.; Sabbatini, L.; Zambonin, G. Analytical characterization of collagen- and/or hydroxyapatite-modified polypyrrole films electrosynthesized on Ti-substrates for the development of new bioactive surfaces. J. Biomater. Sci. Polym. Ed. 2001, 12, 63–76. [Google Scholar] [CrossRef] [PubMed]
  157. Suzuki, Y.; Tanihara, M.; Suzuki, K.; Saitou, A.; Sufan, W.; Nishimura, Y. Alginate hydrogel linked with synthetic oligopeptide derived from BMP-2 allows ectopic osteoinduction in vivo. J. Biomed. Mater. Res. 2000, 50, 405–409. [Google Scholar] [CrossRef]
  158. Wysocki, B.; Idaszek, J.; Zdunek, J.; Rożniatowski, K.; Pisarek, M.; Yamamoto, A.; Święszkowski, W. The influence of selective laser melting (SLM) process parameters on in-vitro cell response. Int. J. Mol. Sci. 2018, 19, 1619. [Google Scholar] [CrossRef] [Green Version]
  159. Zhang, G.; Li, J.; Li, J.; Zhou, X.; Wang, A. Structure and properties of a personalized bio-fixed implant prepared with selective laser melting. Comput. Methods Biomech. Biomed. Engin. 2019, 22, 1034–1042. [Google Scholar] [CrossRef]
  160. Liu, J.Y.; Chen, F.; Ge, Y.J.; Wei, L.; Pan, S.X.; Feng, H.L. Influence of implants prepared by selective laser melting on early bone healing. Beijing Da Xue Xue Bao Yi Xue Ban 2018, 50, 117–122. [Google Scholar]
  161. Mroz, W.; Budner, B.; Syroka, R.; Niedzielski, K.; Golański, G.; Slosarczyk, A.; Schwarze, D.; Douglas, T.E. In vivo implantation of porous titanium alloy implants coated with magnesium-doped octacalcium phosphate and hydroxyapatite thin films using pulsed laser depostion. J. Biomed. Mater. Res. Part B Appl. Biomater. 2015, 103, 151–158. [Google Scholar] [CrossRef]
  162. Radtke, A.; Ehlert, M.; JÄ™drzejewski, T.; Sadowska, B.; WiÄ™ckowska-Szakiel, M.; Holopainen, J.; Ritala, M.; Leskelä, M.; Bartmański, M.; Szkodo, M. Titania nanotubes/hydroxyapatite nanocomposites produced with the use of the atomic layer deposition technique: Estimation of bioactivity and nanomechanical properties. Nanomaterials 2019, 9, 123. [Google Scholar] [CrossRef] [Green Version]
  163. George, S.M. Atomic layer deposition: An overview. Chem. Rev. 2010, 110, 111–131. [Google Scholar] [CrossRef]
  164. Ripamonti, U.; Roden, L.C.; Renton, L.F. Osteoinductive hydroxyapatite-coated titanium implants. Biomaterials 2012, 33, 3813–3823. [Google Scholar] [CrossRef]
  165. Gotfredsen, K. Implant coatings and its application in clinical reality. In Implant Surfaces and Their Biological and Clinical Impact; Springer: Berlin/Heidelberg, Germany, 2015; pp. 147–155. [Google Scholar]
  166. Yeo, I. Surface modification of dental biomaterials for controlling bone response. Bone Response Dent. Implant Mater. 2017, 43–64. [Google Scholar] [CrossRef]
  167. Kunrath, M.; Hübler, R. A bone preservation protocol that enables evaluation of osseointegration of implants with micro-and nanotextured surfaces. Biotech. Histochem. 2019, 94, 261–270. [Google Scholar] [CrossRef] [PubMed]
  168. Manickavasagam, D.; Oyewumi, M.O. Critical assessment of implantable drug delivery devices in glaucoma management. J. Drug Deliv. 2013, 2013, 1–13. [Google Scholar] [CrossRef] [PubMed]
  169. Xu, T.; Wu, L.; Yu, Y.; Li, W.; Zhi, J. Synthesis and characterization of diamond–silver composite with anti-bacterial property. Mater. Lett. 2014, 114, 92–95. [Google Scholar] [CrossRef]
  170. Najeeb, S.; Khurshid, Z.; Agwan, A.S.; Zafar, M.S.; Alrahabi, M.; Qasim, S.B.; Sefat, F. Dental Applications of Nanodiamonds. Sci. Adv. Mater. 2016, 8, 2064–2070. [Google Scholar] [CrossRef] [Green Version]
  171. Gonçalves, J.P.L.; Shaikh, A.Q.; Reitzig, M.; Kovalenko, D.A.; Michael, J.; Beutner, R.; Cuniberti, G.; Scharnweber, D.; Opitz, J. Detonation nanodiamonds biofunctionalization and immobilization to titanium alloy surfaces as first steps towards medical application. Beilstein J. Org. Chem. 2014, 10, 2765–2773. [Google Scholar] [CrossRef] [Green Version]
  172. Park, C.; Park, S.; Lee, D.; Choi, K.S.; Lim, H.; Kim, J. Graphene as an enabling strategy for dental implant and tissue regeneration. Tissue Eng. Regen. Med. 2017, 14, 481–493. [Google Scholar] [CrossRef]
  173. Kaviya, M.; Ramakrishnan, P.; Mohamed, S.; Ramakrishnan, R.; Gimbun, J.; Veerabadran, K.; Kuppusamy, M.; Kaviyarasu, K.; Sridhar, T. Synthesis and characterization of nano-hydroxyapatite/graphene oxide composite materials for medical implant coating applications. Mater. Today Proc. 2020. [Google Scholar] [CrossRef]
  174. Kaya, C.; Singh, I.; Boccaccini, A.R. Multi-walled carbon nanotube-reinforced hydroxyapatite layers on Ti6Al4V medical implants by Electrophoretic Deposition (EPD). Adv. Eng. Mater. 2008, 10, 131–138. [Google Scholar] [CrossRef]
  175. Hirata, E.; Uo, M.; Takita, H.; Akasaka, T.; Watari, F.; Yokoyama, A. Multiwalled carbon nanotube-coating of 3D collagen scaffolds for bone tissue engineering. Carbon 2011, 49, 3284–3291. [Google Scholar] [CrossRef]
  176. Hahn, B.; Lee, J.; Park, D.; Choi, J.; Ryu, J.; Yoon, W.; Lee, B.; Shin, D.; Kim, H. Mechanical and in vitro biological performances of hydroxyapatite–carbon nanotube composite coatings deposited on Ti by aerosol deposition. Acta Biomater. 2009, 5, 3205–3214. [Google Scholar] [CrossRef] [PubMed]
  177. Terada, M.; Abe, S.; Akasaka, T.; Uo, M.; Kitagawa, Y.; Watari, F. Multiwalled carbon nanotube coating on titanium. Biomed. Mater. Eng. 2009, 19, 45–52. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  178. Zhao, L.; Wang, H.; Huo, K.; Cui, L.; Zhang, W.; Ni, H.; Zhang, Y.; Wu, Z.; Chu, P.K. Antibacterial nano-structured titania coating incorporated with silver nanoparticles. Biomaterials 2011, 32, 5706–5716. [Google Scholar] [CrossRef] [PubMed]
  179. Pallavicini, P.; Arciola, C.; Bertoglio, F.; Curtosi, S.; Dacarro, G.; D’Agostino, A.; Ferrari, F.; Merli, D.; Milanese, C.; Rossi, S. Silver nanoparticles synthesized and coated with pectin: An ideal compromise for anti-bacterial and anti-biofilm action combined with wound-healing properties. J. Colloid Interface Sci. 2017, 498, 271–281. [Google Scholar] [CrossRef] [PubMed]
  180. De Groot, K.; Wolke, J.G.C.; Jansen, J.A. Calcium phosphate coatings for medical implants. Proc. Inst. Mech. Eng. Part H J. Eng. Med. 1998, 212, 137–147. [Google Scholar] [CrossRef]
  181. Kay, J.F. Calcium phosphate coatings for dental implants. Current status and future potential. Dent. Clin. N. Am. 1992, 36, 1–18. [Google Scholar]
  182. Alghamdi, H.S.; Cuijpers, V.M.J.I.; Wolke, J.G.C.; van den Beucken, J.J.J.P.; Jansen, J.A. Calcium-phosphate-coated Oral Implants Promote Osseointegration in Osteoporosis. J. Dent. Res. 2013, 92, 982–988. [Google Scholar] [CrossRef]
  183. Leeuwenburgh, S.C.; Wolke, J.G.; Siebers, M.C.; Schoonman, J.; Jansen, J.A. In vitro and in vivo reactivity of porous, electrosprayed calcium phosphate coatings. Biomaterials 2006, 27, 3368–3378. [Google Scholar] [CrossRef]
  184. Bjursten, L.M.; Rasmusson, L.; Oh, S.; Smith, G.C.; Brammer, K.S.; Jin, S. Titanium dioxide nanotubes enhance bone bonding in vivo. J. Biomed. Mater. Res. Part A 2010, 92, 1218–1224. [Google Scholar]
  185. Hilbig, H.; Kirsten, M.; Rupietta, R.; Graf, H.; Tbalbammer, S.; Strasser, S.; Armbruster, F. Implant surface coatings with bone sialoprotein, collagen, and fibronectin and their effects on cells derived from human maxillar bone. Eur. J. Med. Res. 2007, 12, 6. [Google Scholar]
  186. Raphel, J.; Karlsson, J.; Galli, S.; Wennerberg, A.; Lindsay, C.; Haugh, M.G.; Pajarinen, J.; Goodman, S.B.; Jimbo, R.; Andersson, M.; et al. Engineered protein coatings to improve the osseointegration of dental and orthopaedic implants. Biomaterials 2016, 83, 269–282. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  187. Werner, S.; Huck, O.; Frisch, B.; Vautier, D.; Elkaim, R.; Voegel, J.; Brunel, G.; Tenenbaum, H. The effect of microstructured surfaces and laminin-derived peptide coatings on soft tissue interactions with titanium dental implants. Biomaterials 2009, 30, 2291–2301. [Google Scholar] [CrossRef] [PubMed]
  188. El-Ghannam, A.; Starr, L.; Jones, J. Laminin-5 coating enhances epithelial cell attachment, spreading, and hemidesmosome assembly on Ti-6Al-4V implant material in vitro. J. Biomed. Mater. Res. 1998, 41, 30–40. [Google Scholar] [CrossRef]
  189. Graf, H.L.; Stoeva, S.; Armbruster, F.P.; Neuhaus, J.; Hilbig, H. Effect of bone sialoprotein and collagen coating on cell attachment to TICER® and pure titanium implant surfaces. Int. J. Oral Maxillofac. Surg. 2008, 37, 634–640. [Google Scholar] [CrossRef]
  190. Fiorellini, J.P.; Glindmann, S.; Salcedo, J.; Weber, H.; Park, C.; Sarmiento, H.L. The effect of osteopontin and an osteopontin-derived synthetic peptide coating on osseointegration of implants in a canine model. Int. J. Periodontics Restor. Dent. 2016, 36, e88–e94. [Google Scholar] [CrossRef] [Green Version]
  191. Lee, D.; Yun, Y.; Park, K.; Kim, S.E. Gentamicin and bone morphogenic protein-2 (BMP-2)-delivering heparinized-titanium implant with enhanced antibacterial activity and osteointegration. Bone 2012, 50, 974–982. [Google Scholar] [CrossRef]
  192. Liu, Y.; de Groot, K.; Hunziker, E.B. BMP-2 liberated from biomimetic implant coatings induces and sustains direct ossification in an ectopic rat model. Bone 2005, 36, 745–757. [Google Scholar] [CrossRef]
  193. Aebli, N.; Stich, H.; Schawalder, P.; Theis, J.; Krebs, J. Effects of bone morphogenetic protein-2 and hyaluronic acid on the osseointegration of hydroxyapatite-coated implants: An experimental study in sheep. J. Biomed. Mater. Res. Part A Off. J. Soc. Biomater. Jpn. Soc. Biomater. Aust. Soc. Biomater. Korean Soc. Biomater. 2005, 73, 295–302. [Google Scholar] [CrossRef]
  194. Tao, Z.; Zhou, W.; Tu, K.; Huang, Z.; Zhou, Q.; Sun, T.; Lv, Y.; Cui, W.; Yang, L. The effects of combined human parathyroid hormone (1–34) and simvastatin treatment on osseous integration of hydroxyapatite-coated titanium implants in the femur of ovariectomized rats. Injury 2015, 46, 2164–2169. [Google Scholar] [CrossRef]
  195. Ardura, J.A.; Portal-Núñez, S.; Lozano, D.; Gutiérrez-Rojas, I.; Sánchez-Salcedo, S.; López-Herradón, A.; Mulero, F.; Villanueva-Peñacarrillo, M.L.; Vallet-Regí, M.; Esbrit, P. Local delivery of parathyroid hormone-related protein-derived peptides coated onto a hydroxyapatite-based implant enhances bone regeneration in old and diabetic rats. J. Biomed. Mater. Res. Part A 2016, 104, 2060–2070. [Google Scholar] [CrossRef] [Green Version]
  196. Yu, X.; Wang, L.; Jiang, X.; Rowe, D.; Wei, M. Biomimetic CaP coating incorporated with parathyroid hormone improves the osseointegration of titanium implant. J. Mater. Sci. Mater. Med. 2012, 23, 2177–2186. [Google Scholar] [CrossRef] [PubMed]
  197. Li, T.; Wang, N.; Chen, S.; Lu, R.; Li, H.; Zhang, Z. Antibacterial activity and cytocompatibility of an implant coating consisting of TiO2 nanotubes combined with a GL13K antimicrobial peptide. Int. J. Nanomed. 2017, 12, 2995–3007. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  198. Chen, X.; Hirt, H.; Li, Y.; Gorr, S.U.; Aparicio, C. Antimicrobial GL13K peptide coatings killed and ruptured the wall of Streptococcus gordonii and prevented formation and growth of biofilms. PLoS ONE 2014, 9, e111579. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  199. Hwang, D.S.; Waite, J.H.; Tirrell, M. Promotion of osteoblast proliferation on complex coacervation-based hyaluronic acid – recombinant mussel adhesive protein coatings on titanium. Biomaterials 2010, 31, 1080–1084. [Google Scholar] [CrossRef] [Green Version]
  200. Bumgardner, J.D.; Wiser, R.; Gerard, P.D.; Bergin, P.; Chestnutt, B.; Marini, M.; Ramsey, V.; Elder, S.H.; Gilbert, J.A. Chitosan: Potential use as a bioactive coating for orthopaedic and craniofacial/dental implants. J. Biomater. Sci. Polym. Ed. 2003, 14, 423–438. [Google Scholar] [CrossRef]
  201. Husain, S.; Al-Samadani, K.H.; Najeeb, S.; Zafar, M.S.; Khurshid, Z.; Zohaib, S.; Qasim, S.B. Chitosan Biomaterials for Current and Potential Dental Applications. Materials 2017, 10, 602. [Google Scholar] [CrossRef] [Green Version]
  202. Kokkonen, H.; Cassinelli, C.; Verhoef, R.; Morra, M.; Schols, H.; Tuukkanen, J. Differentiation of osteoblasts on pectin-coated titanium. Biomacromolecules 2008, 9, 2369–2376. [Google Scholar] [CrossRef]
  203. Kokkonen, H.; Niiranen, H.; Schols, H.A.; Morra, M.; Stenbäck, F.; Tuukkanen, J. Pectin-coated titanium implants are well-tolerated in vivo. J. Biomed. Mater. Res. Part A 2010, 93, 1404–1409. [Google Scholar] [CrossRef]
  204. Abtahi, J.; Agholme, F.; Sandberg, O.; Aspenberg, P. Effect of Local vs. Systemic Bisphosphonate Delivery on Dental Implant Fixation in a Model of Osteonecrosis of the Jaw. J. Dent. Res. 2013, 92, 279–283. [Google Scholar] [CrossRef]
  205. Zuffetti, F.; Bianchi, F.; Volpi, R.; Trisi, P.; Del Fabbro, M.; Capelli, M.; Galli, F.; Capsoni, F.; Testori, T. Clinical application of bisphosphonates in implant dentistry: Histomorphometric evaluation. Int. J. Periodontics Restor. Dent. 2009, 29, 31–39. [Google Scholar]
  206. Yang, G.; Song, L.; Guo, C.; Zhao, S.; Liu, L.; He, F. Bone responses to simvastatin-loaded porous implant surfaces in an ovariectomized model. Int. J. Oral Maxillofac. Implant. 2012, 27, 369–374. [Google Scholar]
  207. Du, Z.; Chen, J.; Yan, F.; Xiao, Y. Effects of Simvastatin on bone healing around titanium implants in osteoporotic rats. Clin. Oral Implant. Res. 2009, 20, 145–150. [Google Scholar] [CrossRef] [Green Version]
  208. Maïmoun, L.; Brennan, T.C.; Badoud, I.; Dubois-Ferriere, V.; Rizzoli, R.; Ammann, P. Strontium ranelate improves implant osseointegration. Bone 2010, 46, 1436–1441. [Google Scholar] [CrossRef] [PubMed]
  209. Lucke, M.; Schmidmaier, G.; Sadoni, S.; Wildemann, B.; Schiller, R.; Haas, N.P.; Raschke, M. Gentamicin coating of metallic implants reduces implant-related osteomyelitis in rats. Bone 2003, 32, 521–531. [Google Scholar] [CrossRef]
  210. Radin, S.; Ducheyne, P. Controlled release of vancomycin from thin sol–gel films on titanium alloy fracture plate material. Biomaterials 2007, 28, 1721–1729. [Google Scholar] [CrossRef]
  211. Adams, C.S.; Antoci, V., Jr.; Harrison, G.; Patal, P.; Freeman, T.A.; Shapiro, I.M.; Parvizi, J.; Hickok, N.J.; Radin, S.; Ducheyne, P. Controlled release of vancomycin from thin sol-gel films on implant surfaces successfully controls osteomyelitis. J. Orthop. Res. 2009, 27, 701–709. [Google Scholar] [CrossRef]
  212. Antoci, V., Jr.; King, S.B.; Jose, B.; Parvizi, J.; Zeiger, A.R.; Wickstrom, E.; Freeman, T.A.; Composto, R.J.; Ducheyne, P.; Shapiro, I.M. Vancomycin covalently bonded to titanium alloy prevents bacterial colonization. J. Orthop. Res. 2007, 25, 858–866. [Google Scholar] [CrossRef]
  213. Xing, R.; Witsø, I.L.; Jugowiec, D.; Tiainen, H.; Shabestari, M.; Lyngstadaas, S.P.; Lönn-Stensrud, J.; Haugen, H.J. Antibacterial effect of doxycycline-coated dental abutment surfaces. Biomed. Mater. 2015, 10, 055003. [Google Scholar] [CrossRef]
  214. Ferreira, C.F.; Babu, J.; Hamlekhan, A.; Patel, S.; Shokuhfar, T. Efficiency of Nanotube Surface-Treated Dental Implants Loaded with Doxycycline on Growth Reduction of Porphyromonas gingivalis. Int. J. Oral Maxillofac. Implant. 2017, 32, 322–328. [Google Scholar] [CrossRef] [Green Version]
  215. Baghdan, E.; Pinnapireddy, S.R.; Vögeling, H.; Schäfer, J.; Eckert, A.W.; Bakowsky, U. Nano spray drying: A novel technique to prepare well-defined surface coatings for medical implants. J. Drug Deliv. Sci. Technol. 2018, 48, 145–151. [Google Scholar] [CrossRef]
  216. Vitti, R.P.; Pacheco, R.R.; Silva, E.J.N.L.; Prati, C.; Gandolfi, M.G.; Piva, E.; Ogliari, F.A.; Zanchi, C.H.; Sinhoreti, M.A.C. Addition of phosphates and chlorhexidine to resin-modified MTA materials. J. Biomed. Mater. Res. Part B Appl. Biomater. 2019, 107, 2195–2201. [Google Scholar] [CrossRef]
  217. Nasar, A. Hydroxyapatite and its coatings in dental implants. In Applications of Nanocomposite Materials in Dentistry; Elsevier: Amsterdam, The Netherlands, 2019; pp. 145–160. [Google Scholar]
  218. Xiong, J.Y.; Li, Y.C.; Hodgson, P.D.; Wen, C.E. Bioactive hydroxyapatite coating on titanium-niobium alloy through a sol-gel process. In Materials Science Forum; Trans Tech Publ.: Zurich, Switzerland, 2009; Volume 618, pp. 325–328. [Google Scholar]
  219. Visentin, F.; El Habra, N.; Fabrizio, M.; Brianese, N.; Gerbasi, R.; Nodari, L.; Zin, V.; Galenda, A. TiO2-HA bi-layer coatings for improving the bioactivity and service-life of Ti dental implants. Surf. Coat. Technol. 2019, 378, 125049. [Google Scholar] [CrossRef]
  220. Junker, R.; Dimakis, A.; Thoneick, M.; Jansen, J.A. Effects of implant surface coatings and composition on bone integration: A systematic review. Clin. Oral Implant. Res. 2009, 20, 185–206. [Google Scholar] [CrossRef]
  221. Jalota, S.; Bhaduri, S.B.; Tas, A.C. Osteoblast proliferation on neat and apatite-like calcium phosphate-coated titanium foam scaffolds. Mater. Sci. Eng. C 2007, 27, 432–440. [Google Scholar] [CrossRef]
  222. Choi, A.H.; Ben-Nissan, B.; Matinlinna, J.P.; Conway, R.C. Current perspectives: Calcium phosphate nanocoatings and nanocomposite coatings in dentistry. J. Dent. Res. 2013, 92, 853–859. [Google Scholar] [CrossRef]
  223. Ben-Nissan, B.; Choi, A.H. Sol-gel production of bioactive nanocoatings for medical applications. Part 1: An introduction. Nanomedicine 2006, 1, 311–319. [Google Scholar] [CrossRef]
  224. Lin, O.C.; Chao, E. Perspectives on Biomaterials: Proceedings of the 1985 International Symposium on Biomaterials, Taipei, Taiwan, 25–27 February 1985; Elsevier Publishing Company: Amsterdam, The Netherlands, 1986; Volume 33. [Google Scholar]
  225. Morris, H.F.; Ochi, S.; Spray, J.R.; Olson, J.W. Periodontal-Type Measurements Associated With Hydroxyapatite-Coated and Non—HA-Coated Implants: Uncovering to 36 Months. Ann. Periodontol. 2000, 5, 56–67. [Google Scholar] [CrossRef]
  226. Habibovic, P.; Li, J.; Van Der Valk, C.M.; Meijer, G.; Layrolle, P.; Van Blitterswijk, C.A.; De Groot, K. Biological performance of uncoated and octacalcium phosphate-coated Ti6Al4V. Biomaterials 2005, 26, 23–36. [Google Scholar] [CrossRef]
  227. Barrere, F.; Van Der Valk, C.; Meijer, G.; Dalmeijer, R.; De Groot, K.; Layrolle, P. Osteointegration of biomimetic apatite coating applied onto dense and porous metal implants in femurs of goats. J. Biomed. Mater. Res. Part B Appl. Biomater. 2003, 67, 655–665. [Google Scholar] [CrossRef]
  228. Yarramaneni, V.; Aparna, I.; Sachdeva, A.; Balakrishnan, D.; Prabhu, N. Emerging antibacterial coated dental implants: A preventive measure for peri-implantitis. World J. Dent. 2016, 7, 195–198. [Google Scholar] [CrossRef]
  229. Inzana, J.A.; Schwarz, E.M.; Kates, S.L.; Awad, H.A. Biomaterials approaches to treating implant-associated osteomyelitis. Biomaterials 2016, 81, 58–71. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  230. Chen, W.; Shen, X.; Hu, Y.; Xu, K.; Ran, Q.; Yu, Y.; Dai, L.; Yuan, Z.; Huang, L.; Shen, T. Surface functionalization of titanium implants with chitosan-catechol conjugate for suppression of ROS-induced cells damage and improvement of osteogenesis. Biomaterials 2017, 114, 82–96. [Google Scholar] [CrossRef] [PubMed]
  231. Karacan, I.; Ben-Nissan, B.; Wang, H.A.; Juritza, A.; Swain, M.V.; Müller, W.H.; Chou, J.; Stamboulis, A.; Macha, I.J.; Taraschi, V. Mechanical testing of antimicrobial biocomposite coating on metallic medical implants as drug delivery system. Mater. Sci. Eng. C 2019, 104, 109757. [Google Scholar] [CrossRef]
  232. De Avila, E.D.; Castro, A.G.; Tagit, O.; Krom, B.P.; Löwik, D.; van Well, A.A.; Bannenberg, L.J.; Vergani, C.E.; van den Beucken, J.J. Anti-bacterial efficacy via drug-delivery system from layer-by-layer coating for percutaneous dental implant components. Appl. Surf. Sci. 2019, 488, 194–204. [Google Scholar] [CrossRef]
  233. Mandracci, P.; Mussano, F.; Rivolo, P.; Carossa, S. Surface treatments and functional coatings for biocompatibility improvement and bacterial adhesion reduction in dental implantology. Coatings 2016, 6, 7. [Google Scholar] [CrossRef] [Green Version]
  234. Sani, E.S.; Lara, R.P.; Aldawood, Z.; Bassir, S.H.; Nguyen, D.; Kantarci, A.; Intini, G.; Annabi, N. An antimicrobial dental light curable bioadhesive hydrogel for treatment of peri-implant diseases. Matter 2019, 1, 926–944. [Google Scholar] [CrossRef] [Green Version]
  235. Water, J.J.; Bohr, A.; Boetker, J.; Aho, J.; Sandler, N.; Nielsen, H.M.; Rantanen, J. Three-dimensional printing of drug-eluting implants: Preparation of an antimicrobial polylactide feedstock material. J. Pharm. Sci. 2015, 104, 1099–1107. [Google Scholar] [CrossRef]
  236. De Cremer, K.; Braem, A.; Gerits, E.; De Brucker, K.; Vandamme, K.; Martens, J.A.; Michiels, J.; Vleugels, J.; Cammue, B.P.; Thevissen, K. Controlled release of chlorhexidine from a mesoporous silica-containing macroporous titanium dental implant prevents microbial biofilm formation. Eur. Cell. Mater. 2017, 33, 13–27. [Google Scholar] [CrossRef]
  237. Baghdan, E.; Raschpichler, M.; Lutfi, W.; Pinnapireddy, S.R.; Pourasghar, M.; Schäfer, J.; Schneider, M.; Bakowsky, U. Nano spray dried antibacterial coatings for dental implants. Eur. J. Pharm. Biopharm. 2019, 139, 59–67. [Google Scholar] [CrossRef]
  238. Popat, K.C.; Eltgroth, M.; LaTempa, T.J.; Grimes, C.A.; Desai, T.A. Decreased Staphylococcus epidermis adhesion and increased osteoblast functionality on antibiotic-loaded titania nanotubes. Biomaterials 2007, 28, 4880–4888. [Google Scholar] [CrossRef]
  239. Cox, S.C.; Jamshidi, P.; Eisenstein, N.M.; Webber, M.A.; Hassanin, H.; Attallah, M.M.; Shepherd, D.E.; Addison, O.; Grover, L.M. Adding functionality with additive manufacturing: Fabrication of titanium-based antibiotic eluting implants. Mater. Sci. Eng. C 2016, 64, 407–415. [Google Scholar] [CrossRef] [Green Version]
  240. Swanson, T.; Cheng, X.; Friedrich, C. Development of chitosan–vancomycin antimicrobial coatings on titanium implants. J. Biomed. Mater. Res. Part A 2011, 97, 167–176. [Google Scholar] [CrossRef]
  241. Rojas-Montoya, I.D.; Fosado-Esquivel, P.; Henao-Holguín, L.V.; Esperanza-Villegas, A.E.; Bernad-Bernad, M.; Gracia-Mora, J. Adsorption/desorption studies of norfloxacin on brushite nanoparticles from reverse microemulsions. Adsorption 2019, 1–10. [Google Scholar] [CrossRef]
  242. Russell, A.D.; Day, M.J. Antibacterial activity of chlorhexidine. J. Hosp. Infect. 1993, 25, 229–238. [Google Scholar] [CrossRef]
  243. Wood, N.J.; Jenkinson, H.F.; Davis, S.A.; Mann, S.; O’Sullivan, D.J.; Barbour, M.E. Chlorhexidine hexametaphosphate nanoparticles as a novel antimicrobial coating for dental implants. J. Mater. Sci. Mater. Med. 2015, 26, 201. [Google Scholar] [CrossRef] [Green Version]
  244. Cortizo, M.C.; Oberti, T.G.; Cortizo, M.S.; Cortizo, A.M.; de Mele, M.A.F.L. Chlorhexidine delivery system from titanium/polybenzyl acrylate coating: Evaluation of cytotoxicity and early bacterial adhesion. J. Dent. 2012, 40, 329–337. [Google Scholar] [CrossRef] [Green Version]
  245. Dias, H.B.; Bernardi, M.I.B.; Bauab, T.M.; Hernandes, A.C.; de Souza Rastelli, A.N. Titanium dioxide and modified titanium dioxide by silver nanoparticles as an anti biofilm filler content for composite resins. Dent. Mater. 2019, 35, e36–e46. [Google Scholar] [CrossRef]
  246. Roy, M.; Bandyopadhyay, A.; Bose, S. In vitro antimicrobial and biological properties of laser assisted tricalcium phosphate coating on titanium for load bearing implant. Mater. Sci. Eng. C 2009, 29, 1965–1968. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  247. Rottmar, M.; Müller, E.; Guimond-Lischer, S.; Stephan, M.; Berner, S.; Maniura-Weber, K. Assessing the osteogenic potential of zirconia and titanium surfaces with an advanced in vitro model. Dent. Mater. 2019, 35, 74–86. [Google Scholar] [CrossRef] [PubMed]
  248. Sanpo, N.; Ang, S.M.; Cheang, P.; Khor, K.A. Antibacterial Property of Cold Sprayed Chitosan-Cu/Al Coating. J. Therm. Spray Technol. 2009, 18, 600. [Google Scholar] [CrossRef]
  249. Xie, Y.; Li, H.; Ding, C.; Zheng, X.; Li, K. Effects of graphene plates’ adoption on the microstructure, mechanical properties, and in vivo biocompatibility of calcium silicate coating. Int. J. Nanomed. 2015, 10, 3855–3863. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  250. Zeng, Y.; Pei, X.; Yang, S.; Qin, H.; Cai, H.; Hu, S.; Sui, L.; Wan, Q.; Wang, J. Graphene oxide/hydroxyapatite composite coatings fabricated by electrochemical deposition. Surf. Coat. Technol. 2016, 286, 72–79. [Google Scholar] [CrossRef]
  251. Chen, J.; Peng, H.; Wang, X.; Shao, F.; Yuan, Z.; Han, H. Graphene oxide exhibits broad-spectrum antimicrobial activity against bacterial phytopathogens and fungal conidia by intertwining and membrane perturbation. Nanoscale 2014, 6, 1879–1889. [Google Scholar] [CrossRef]
  252. Mochalin, V.N.; Neitzel, I.; Etzold, B.J.M.; Peterson, A.; Palmese, G.; Gogotsi, Y. Covalent incorporation of aminated nanodiamond into an epoxy polymer network. ACS Nano 2011, 5, 7494–7502. [Google Scholar] [CrossRef] [PubMed]
  253. Vaitkuviene, A.; McDonald, M.; Vahidpour, F.; Noben, J.; Sanen, K.; Ameloot, M.; Ratautaite, V.; Kaseta, V.; Biziuleviciene, G.; Ramanaviciene, A. Impact of differently modified nanocrystalline diamond on the growth of neuroblastoma cells. New Biotechnol. 2015, 32, 7–12. [Google Scholar] [CrossRef]
  254. Vaitkuviene, A.; Ratautaite, V.; Ramanaviciene, A.; Sanen, K.; Paesen, R.; Ameloot, M.; Petrakova, V.; McDonald, M.; Vahidpour, F.; Kaseta, V. Impact of diamond nanoparticles on neural cells. Mol. Cell. Probes 2015, 29, 25–30. [Google Scholar] [CrossRef]
  255. Alcaide, M.; Taylor, A.; Fjorback, M.; Zachar, V.; Pennisi, C.P. Boron-doped nanocrystalline diamond electrodes for neural interfaces: In vivo biocompatibility evaluation. Front. Neurosci. 2016, 10, 87. [Google Scholar] [CrossRef] [Green Version]
  256. Mohan, N.; Chen, C.; Hsieh, H.; Wu, Y.; Chang, H. In vivo imaging and toxicity assessments of fluorescent nanodiamonds in Caenorhabditis elegans. Nano Lett. 2010, 10, 3692–3699. [Google Scholar] [CrossRef]
  257. Liu, K.; Cheng, C.; Chang, C.; Chao, J. Biocompatible and detectable carboxylated nanodiamond on human cell. Nanotechnology 2007, 18, 325102. [Google Scholar] [CrossRef]
  258. Townsend, L.; Williams, R.L.; Anuforom, O.; Berwick, M.R.; Halstead, F.; Hughes, E.; Stamboulis, A.; Oppenheim, B.; Gough, J.; Grover, L. Antimicrobial peptide coatings for hydroxyapatite: Electrostatic and covalent attachment of antimicrobial peptides to surfaces. J. R. Soc. Interface 2017, 14, 20160657. [Google Scholar] [CrossRef] [Green Version]
  259. Frieden, T. Antibiotic Resistance Threats in the United States; Centers for Disease Control and Prevention: Atlanta, GA, USA, 2013; pp. 1–114.
  260. Bazli, L.; Chahardehi, A.M.; Arsad, H.; Malekpouri, B.; Jazi, M.A.; Azizabadi, N. Factors influencing the failure of dental implants: A Systematic Review. J. Compos. Compd. 2020, 2, 18–25. [Google Scholar]
  261. Kelly, M.; Williams, R.; Aojula, A.; O’Neill, J.; Trzińscka, Z.; Grover, L.; Scott, R.A.; Peacock, A.F.; Logan, A.; Stamboulis, A. Peptide aptamers: Novel coatings for orthopaedic implants. Mater. Sci. Eng. C 2015, 54, 84–93. [Google Scholar] [CrossRef] [PubMed]
  262. Najeeb, S.; Mali, M.; Yaqin, S.A.U.; Zafar, M.S.; Khurshid, Z.; Alwadaani, A.; Matinlinna, J.P. Dental implants materials and surface treatments. In Advanced Dental Biomaterials; Elsevier: Amsterdam, The Netherlands, 2019; pp. 581–598. [Google Scholar]
  263. Zhang, L.; Gallo, R.L. Antimicrobial peptides. Curr. Biol. 2016, 26, R14–R19. [Google Scholar] [CrossRef] [PubMed]
  264. Khurshid, Z.; Naseem, M.; Sheikh, Z.; Najeeb, S.; Shahab, S.; Zafar, M.S. Oral Antimicrobial Peptides: Types and Role in the Oral Cavity. Saudi Pharm. J. 2015, 24, 515–524. [Google Scholar] [CrossRef] [Green Version]
  265. Khurshid, Z.; Naseem, M.; Yahya I Asiri, F.; Mali, M.; Sannam Khan, R.; Sahibzada, H.A.; Zafar, M.S.; Faraz Moin, S.; Khan, E. Significance and Diagnostic Role of Antimicrobial Cathelicidins (LL-37) Peptides in Oral Health. Biomolecules 2017, 7, 80. [Google Scholar] [CrossRef] [Green Version]
  266. Khurshid, Z.; Zohaib, S.; Najeeb, S.; Zafar, M.S.; Rehman, R.; Rehman, I.U. Advances of Proteomic Sciences in Dentistry. Int. J. Mol. Sci. 2016, 17, 728. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  267. Khurshid, Z.; Zafar, M.S.; Naseem, M.; Khan, R.S.; Najeeb, S. Human Oral Defensins Antimicrobial Peptides: A Future Promising Antimicrobial Drug. Curr. Pharm. Des. 2018, 24, 1130–1137. [Google Scholar] [CrossRef]
  268. Lepage, P.; Heckel, C.; Humbert, S.; Stahl, S.; Rautmann, G. Recombinant technology as an alternative to chemical peptide synthesis: Expression and characterization of HIV-1 Rev recombinant peptides. Anal. Biochem. 1993, 213, 40–48. [Google Scholar] [CrossRef]
  269. Coin, I.; Beyermann, M.; Bienert, M. Solid-phase peptide synthesis: From standard procedures to the synthesis of difficult sequences. Nat. Protoc. 2007, 2, 3247–3256. [Google Scholar] [CrossRef]
  270. Javaid, M.A.; Khurshid, Z.; Zafar, M.S.; Najeeb, S. Immediate Implants: Clinical Guidelines for Esthetic Outcomes. Dent. J. 2016, 4, 21. [Google Scholar] [CrossRef]
  271. Yoshinari, M.; Matsuzaka, K.; Inoue, T. Surface modification by cold-plasma technique for dental implants—Bio-functionalization with binding pharmaceuticals. Jpn. Dent. Sci. Rev. 2011, 47, 89–101. [Google Scholar] [CrossRef] [Green Version]
  272. Fernandez-Garcia, E.; Chen, X.; Gutierrez-Gonzalez, C.F.; Fernandez, A.; Lopez-Esteban, S.; Aparicio, C. Peptide-functionalized zirconia and new zirconia/titanium biocermets for dental applications. J. Dent. 2015, 43, 1162–1174. [Google Scholar] [CrossRef]
  273. Zhou, L.; Lai, Y.; Huang, W.; Huang, S.; Xu, Z.; Chen, J.; Wu, D. Biofunctionalization of microgroove titanium surfaces with an antimicrobial peptide to enhance their bactericidal activity and cytocompatibility. Colloids Surf. B Biointerfaces 2015, 128, 552–560. [Google Scholar] [CrossRef] [PubMed]
  274. Godoy-Gallardo, M.; Mas-Moruno, C.; Yu, K.; Manero, J.M.; Gil, F.J.; Kizhakkedathu, J.N.; Rodriguez, D. Antibacterial properties of hLf1–11 peptide onto titanium surfaces: A comparison study between silanization and surface initiated polymerization. Biomacromolecules 2015, 16, 483–496. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  275. Godoy-Gallardo, M.; Mas-Moruno, C.; Fernández-Calderón, M.C.; Pérez-Giraldo, C.; Manero, J.M.; Albericio, F.; Gil, F.J.; Rodríguez, D. Covalent immobilization of hLf1-11 peptide on a titanium surface reduces bacterial adhesion and biofilm formation. Acta Biomater. 2014, 10, 3522–3534. [Google Scholar] [CrossRef] [PubMed]
  276. Khurshid, Z. Synthesis and Characterization of Antimicrobial Peptides for Medical and Dental Applications; University of Birmingham: Birmingham, England, 2015. [Google Scholar]
  277. Righino, B.; Pirolli, D.; Radicioni, G.; Marzano, V.; Longhi, R.; Arcovito, A.; Sanna, M.T.; De Rosa, M.C.; Paoluzi, S.; Cesareni, G. Structural studies and SH3 domain binding properties of a human antiviral salivary proline-rich peptide. Pept. Sci. 2016, 106, 714–725. [Google Scholar] [CrossRef]
  278. Warnke, P.H.; Voss, E.; Russo, P.A.; Stephens, S.; Kleine, M.; Terheyden, H.; Liu, Q. Antimicrobial peptide coating of dental implants: Biocompatibility assessment of recombinant human beta defensin-2 for human cells. Int. J. Oral Maxillofac. Implant. 2013, 28, 982–988. [Google Scholar] [CrossRef] [Green Version]
  279. Wisdom, C.; Chen, C.; Yuca, E.; Zhou, Y.; Tamerler, C.; Snead, M.L. Repeatedly applied peptide film kills bacteria on dental implants. JOM 2019, 71, 1271–1280. [Google Scholar] [CrossRef] [Green Version]
  280. Abtahi, J.; Tengvall, P.; Aspenberg, P. Bisphosphonate coating might improve fixation of dental implants in the maxilla: A pilot study. Int. J. Oral Maxillofac. Surg. 2010, 39, 673–677. [Google Scholar] [CrossRef]
  281. Im, G.; Qureshi, S.A.; Kenney, J.; Rubash, H.E.; Shanbhag, A.S. Osteoblast proliferation and maturation by bisphosphonates. Biomaterials 2004, 25, 4105–4115. [Google Scholar] [CrossRef]
  282. Jobke, B.; Milovanovic, P.; Amling, M.; Busse, B. Bisphosphonate-osteoclasts: Changes in osteoclast morphology and function induced by antiresorptive nitrogen-containing bisphosphonate treatment in osteoporosis patients. Bone 2014, 59, 37–43. [Google Scholar] [CrossRef] [PubMed]
  283. Keller, J.C.; Stewart, M.; Roehm, M.; Schneider, G.B. Osteoporosis-like bone conditions affect osseointegration of implants. Int. J. Oral Maxillofac. Implant. 2004, 19, 687–694. [Google Scholar]
  284. Giro, G.; Chambrone, L.; Goldstein, A.; Rodrigues, J.A.; Zenobio, E.; Feres, M.; Figueiredo, L.C.; Cassoni, A.; Shibli, J.A. Impact of osteoporosis in dental implants: A systematic review. World J. Orthop. 2015, 6, 311–315. [Google Scholar] [CrossRef] [PubMed]
  285. Curi, M.M.; Cossolin, G.S.; Koga, D.H.; Zardetto, C.; Christianini, S.; Feher, O.; Cardoso, C.L.; dos Santos, M.O. Bisphosphonate-related osteonecrosis of the jaws—An initial case series report of treatment combining partial bone resection and autologous platelet-rich plasma. J. Oral Maxillofac. Surg. 2011, 69, 2465–2472. [Google Scholar] [CrossRef] [PubMed]
  286. Sharma, A.; Pradeep, A. Clinical efficacy of 1% alendronate gel in adjunct to mechanotherapy in the treatment of aggressive periodontitis: A randomized controlled clinical trial. J. Periodontol. 2012, 83, 19–26. [Google Scholar] [CrossRef]
  287. De Sarkar, A.; Singhvi, N.; Shetty, J.N.; Ramakrishna, T.; Shetye, O.; Islam, M.; Keerthy, H. The local effect of alendronate with intra-alveolar collagen sponges on post extraction alveolar ridge resorption: A clinical trial. J. Maxillofac. Oral Surg. 2015, 14, 344–356. [Google Scholar] [CrossRef] [Green Version]
  288. Levin, L.; Bryson, E.C.; Caplan, D.; Trope, M. Effect of topical alendronate on root resorption of dried replanted dog teeth. Dent. Traumatol. 2001, 17, 120–126. [Google Scholar] [CrossRef]
  289. Najeeb, S.; Siddiqui, F.; Khurshid, Z.; Zohaib, S.; Zafar, M.S.; Ansari, S.A. Effect of bisphosphonates on root resorption after tooth replantation–a systematic review. Dent. Traumatol. 2017, 33, 77–83. [Google Scholar] [CrossRef] [Green Version]
  290. Pura, J.A.; Bobyn, J.D.; Tanzer, M. Implant-delivered Alendronate Causes a Dose-dependent Response on Net Bone Formation Around Porous Titanium Implants in Canines. Clin. Orthop. Relat. Res. 2016, 474, 1224–1233. [Google Scholar] [CrossRef] [Green Version]
  291. Denissen, H.; Montanari, C.; Martinetti, R.; van Lingen, A.; van den Hooff, A. Alveolar bone response to submerged bisphosphonate-complexed hydroxyapatite implants. J. Periodontol. 2000, 71, 279–286. [Google Scholar] [CrossRef]
  292. Pyo, S.W.; Kim, Y.M.; Kim, C.S.; Lee, I.S.; Park, J.U. Bone formation on biomimetic calcium phosphate-coated and zoledronate-immobilized titanium implants in osteoporotic rat tibiae. Int. J. Oral Maxillofac. Implant. 2014, 29, 478–484. [Google Scholar] [CrossRef]
  293. Lee, S.; Oh, T.; Bae, T.; Lee, M.; Soh, Y.; Kim, B.; Kim, H.S. Effect of bisphosphonates on anodized and heat-treated titanium surfaces: An animal experimental study. J. Periodontol. 2011, 82, 1035–1042. [Google Scholar] [CrossRef] [Green Version]
  294. Karlsson, J.; Harmankaya, N.; Allard, S.; Palmquist, A.; Halvarsson, M.; Tengvall, P.; Andersson, M. Ex vivo alendronate localization at the mesoporous titania implant/bone interface. J. Mater. Sci. Mater. Med. 2015, 26, 1–8. [Google Scholar] [CrossRef]
  295. Pilathadka, S.; Vahalová, D.; Vosáhlo, T. The Zirconia: A new dental ceramic material. An overview. Prague Med. Rep. 2007, 108, 5–12. [Google Scholar] [PubMed]
  296. Piconi, C.; Maccauro, G. Zirconia as a ceramic biomaterial. Biomaterials 1999, 20, 1–25. [Google Scholar] [CrossRef]
  297. Luthardt, R.; Holzhüter, M.; Sandkuhl, O.; Herold, V.; Schnapp, J.; Kuhlisch, E.; Walter, M. Reliability and properties of ground Y-TZP-zirconia ceramics. J. Dent. Res. 2002, 81, 487–491. [Google Scholar] [CrossRef]
  298. Bona, A.D.; Pecho, O.E.; Alessandretti, R. Zirconia as a dental biomaterial. Materials 2015, 8, 4978–4991. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  299. Becher, P.F.; Swain, M.V. Grain-size-dependent transformation behavior in polycrystalline tetragonal zirconia. J. Am. Ceram. Soc. 1992, 75, 493–502. [Google Scholar] [CrossRef]
  300. Nistor, L.; Grădinaru, M.; Rîcă, R.; Mărășescu, P.; Stan, M.; Manolea, H.; Ionescu, A.; Moraru, I. Zirconia use in dentistry-manufacturing and properties. Curr. Health Sci. J. 2019, 45, 28. [Google Scholar] [PubMed]
  301. Malkondu, Ö.; Tinastepe, N.; Akan, E.; Kazazoğlu, E. An overview of monolithic zirconia in dentistry. Biotechnol. Biotechnol. Equip. 2016, 30, 644–652. [Google Scholar] [CrossRef] [Green Version]
  302. Apratim, A.; Eachempati, P.; Krishnappa Salian, K.K.; Singh, V.; Chhabra, S.; Shah, S. Zirconia in dental implantology: A review. J. Int. Soc. Prev. Community Dent. 2015, 5, 147–156. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  303. Scarano, A.; Di Carlo, F.; Quaranta, M.; Piattelli, A. Bone response to zirconia ceramic implants: An experimental study in rabbits. J. Oral Implantol. 2003, 29, 8–12. [Google Scholar] [CrossRef]
  304. Kohal, R.J.; Weng, D.; Bächle, M.; Strub, J.R. Loaded custom-made zirconia and titanium implants show similar osseointegration: An animal experiment. J. Periodontol. 2004, 75, 1262–1268. [Google Scholar] [CrossRef] [PubMed]
  305. Akagawa, Y.; Ichikawa, Y.; Nikai, H.; Tsuru, H. Interface histology of unloaded and early loaded partially stabilized zirconia endosseous implant in initial bone healing. J. Prosthet. Dent. 1993, 69, 599–604. [Google Scholar] [CrossRef]
  306. Pekkan, G.; Pekkan, K.; Hatipoglu, M.G.; Tuna, S.H. Comparative radiopacity of ceramics and metals with human and bovine dental tissues. J. Prosthet. Dent. 2011, 106, 109–117. [Google Scholar] [CrossRef]
  307. Rimondini, L.; Cerroni, L.; Carrassi, A.; Torriceni, P. Bacterial colonization of zirconia ceramic surfaces: An in vitro and in vivo study. Int. J. Oral Maxillofac. Implant. 2002, 17, 793–798. [Google Scholar]
  308. Tschernitschek, H.; Borchers, L.; Geurtsen, W. Nonalloyed titanium as a bioinert metal—A review. Quintessence Int. 2005, 36, 523–530. [Google Scholar] [CrossRef]
  309. Madfa, A.A.; Al-Sanabani, F.A.; Al-Qudami, N.H.; Al-Sanabani, J.S.; Amran, A.G. Use of zirconia in dentistry: An overview. Open Biomater. J. 2014, 5, 1–9. [Google Scholar] [CrossRef]
  310. Depprich, R.; Zipprich, H.; Ommerborn, M.; Naujoks, C.; Wiesmann, H.; Kiattavorncharoen, S.; Lauer, H.; Meyer, U.; Kübler, N.R.; Handschel, J. Osseointegration of zirconia implants compared with titanium: An in vivo study. Head Face Med. 2008, 4, 30. [Google Scholar] [CrossRef] [Green Version]
  311. Bächle, M.; Butz, F.; Hübner, U.; Bakalinis, E.; Kohal, R.J. Behavior of CAL72 osteoblast-like cells cultured on zirconia ceramics with different surface topographies. Clin. Oral Implant. Res. 2007, 18, 53–59. [Google Scholar] [CrossRef]
  312. Degidi, M.; Artese, L.; Scarano, A.; Perrotti, V.; Gehrke, P.; Piattelli, A. Inflammatory infiltrate, microvessel density, nitric oxide synthase expression, vascular endothelial growth factor expression, and proliferative activity in peri-implant soft tissues around titanium and zirconium oxide healing caps. J. Periodontol. 2006, 77, 73–80. [Google Scholar] [CrossRef] [PubMed]
  313. Größner-Schreiber, B.; Herzog, M.; Hedderich, J.; Dück, A.; Hannig, M.; Griepentrog, M. Focal adhesion contact formation by fibroblasts cultured on surface-modified dental implants: An in vitro study. Clin. Oral Implant. Res. 2006, 17, 736–745. [Google Scholar] [CrossRef] [PubMed]
  314. Ko, N.; Mine, A.; Egusa, H.; Shimazu, T.; Ko, R.; Nakano, T.; Yatani, H. Allergic Reaction to Titanium-Made Fixed Dental Restorations: A Clinical Report. J. Prosthodont. 2014, 23, 501–503. [Google Scholar] [CrossRef] [PubMed]
  315. Sterner, T.; Schutze, N.; Saxler, G.; Jakob, F.; Rader, C.P. Effects of clinically relevant alumina ceramic, zirconia ceramic and titanium particles of different sizes and concentrations on TNF-alpha release in a human macrophage cell line. Biomed. Tech. 2004, 49, 340–344. [Google Scholar] [CrossRef] [PubMed]
  316. Alghamdi, H.S. Methods to improve osseointegration of dental implants in low quality (type-IV) bone: An overview. J. Funct. Biomater. 2018, 9, 7. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  317. Stanford, C. Surface modifications of dental implants. Aust. Dent. J. 2008, 53, S26–S33. [Google Scholar] [CrossRef]
  318. Ferguson, S.J.; Langhoff, J.D.; Voelter, K.; von Rechenberg, B.; Scharnweber, D.; Bierbaum, S.; Schnabelrauch, M.; Kautz, A.R.; Frauchiger, V.M.; Mueller, T.L.; et al. Biomechanical comparison of different surface modifications for dental implants. Int. J. Oral Maxillofac. Implant. 2008, 23, 1037–1046. [Google Scholar]
  319. Gahlert, M.; Gudehus, T.; Eichhorn, S.; Steinhauser, E.; Kniha, H.; Erhardt, W. Biomechanical and histomorphometric comparison between zirconia implants with varying surface textures and a titanium implant in the maxilla of miniature pigs. Clin. Oral Implant. Res. 2007, 18, 662–668. [Google Scholar] [CrossRef]
  320. Yang, Y.; Ong, J.L.; Tian, J. Deposition of highly adhesive ZrO2 coating on Ti and CoCrMo implant materials using plasma spraying. Biomaterials 2003, 24, 619–627. [Google Scholar] [CrossRef]
  321. Huang, Z.; Wang, Z.; Li, C.; Yin, K.; Hao, D.; Lan, J. Application of Plasma-Sprayed Zirconia Coating in Dental Implants: Study in Implants. J. Oral Implantol. 2018, 44, 102–109. [Google Scholar] [CrossRef]
  322. Shon, W.; Chung, S.H.; Kim, H.; Han, G.; Cho, B.; Park, Y. Peri-implant bone formation of non-thermal atmospheric pressure plasma–treated zirconia implants with different surface roughness in rabbit tibiae. Clin. Oral Implant. Res. 2014, 25, 573–579. [Google Scholar] [CrossRef] [PubMed]
  323. Gongadze, E.; Kabaso, D.; Bauer, S.; Slivnik, T.; Schmuki, P.; van Rienen, U.; Iglic, A. Adhesion of osteoblasts to a nanorough titanium implant surface. Int. J. Nanomed. 2011, 6, 1801–1816. [Google Scholar]
  324. Salem, N.A.; Abo Taleb, A.L.; Aboushelib, M.N. Biomechanical and histomorphometric evaluation of osseointegration of fusion-sputtered zirconia implants. J. Prosthodont. 2013, 22, 261–267. [Google Scholar] [CrossRef] [PubMed]
  325. Sivaraman, K.; Chopra, A.; Narayan, A.I.; Balakrishnan, D. Is zirconia a viable alternative to titanium for oral implant? A critical review. J. Prosthodont. Res. 2018, 62, 121–133. [Google Scholar] [CrossRef] [PubMed]
  326. Wenz, H.J.; Bartsch, J.; Wolfart, S.; Kern, M. Osseointegration and clinical success of zirconia dental implants: A systematic review. Int. J. Prosthodont. 2008, 21, 27–36. [Google Scholar]
  327. Alam, M.N.; Anand, N.; Chandrasekaran, S.; Kovendhan, Y. Is primary stability the gold standard factor in implant success. Dent. Hypotheses 2014, 5, 70. [Google Scholar]
  328. Cobo-Vazquez, C.; Reininger, D.; Molinero-Mourelle, P.; Gonzalez-Serrano, J.; Guisado-Moya, B.; Lopez-Quiles, J. Effect of the lack of primary stability in the survival of dental implants. J. Clin. Exp. Dent. 2018, 10, e14–e19. [Google Scholar] [CrossRef]
  329. Esposito, M. Biological factors contributing to failures of osseointegrated oral implants. (l). Success criteria and epidemiology. Eur. J. Oral Sci. 1998, 106, 527–551. [Google Scholar] [CrossRef]
  330. Esposito, M.; Hirsch, J.; Lekholm, U.; Thomsen, P. Biological factors contributing to failures of osseointegrated oral implants, (II). Etiopathogenesis. Eur. J. Oral Sci. 1998, 106, 721–764. [Google Scholar] [CrossRef]
  331. Filiaggi, M.J.; Coombs, N.A.; Pilliar, R.M. Characterization of the interface in the plasma-sprayed HA coating/Ti-6Al-4V implant system. J. Biomed. Mater. Res. 1991, 25, 1211–1229. [Google Scholar] [CrossRef]
  332. Munting, E. The contributions and limitations of hydroxyapatite coatings to implant fixation. Int. Orthop. 1996, 20, 1–6. [Google Scholar] [CrossRef] [PubMed]
  333. Aebli, N.; Krebs, J.; Stich, H.; Schawalder, P.; Walton, M.; Schwenke, D.; Gruner, H.; Gasser, B.; Theis, J. In vivo comparison of the osseointegration of vacuum plasma sprayed titanium- and hydroxyapatite-coated implants. J. Biomed. Mater. Res. Part A 2003, 66A, 356–363. [Google Scholar] [CrossRef] [PubMed]
  334. Roy, M.; Bandyopadhyay, A.; Bose, S. Induction plasma sprayed nano hydroxyapatite coatings on titanium for orthopaedic and dental implants. Surf. Coat. Technol. 2011, 205, 2785–2792. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  335. Sun, L.; Berndt, C.C.; Gross, K.A.; Kucuk, A. Material fundamentals and clinical performance of plasma-sprayed hydroxyapatite coatings: A review. J. Biomed. Mater. Res. Part A 2001, 58, 570–592. [Google Scholar] [CrossRef] [PubMed]
  336. Wheeler, S.L. Eight-year clinical retrospective study of titanium plasma-sprayed and hydroxyapatite-coated cylinder implants. Int. J. Oral Maxillofac. Implant. 1996, 11, 340–350. [Google Scholar] [CrossRef]
  337. Tinsley, D.; Watson, C.J.; Russell, J.L. A comparison of hydroxylapatite coated implant retained fixed and removable mandibular prostheses over 4 to 6 years. Clin. Oral Implant. Res. 2001, 12, 159–166. [Google Scholar] [CrossRef]
Figure 1. Drug release from implantable biomaterials and description of various types of carrier-based drug-releasing biomaterials [64].
Figure 1. Drug release from implantable biomaterials and description of various types of carrier-based drug-releasing biomaterials [64].
Coatings 10 00568 g001
Figure 2. Different drug release mechanisms from nano-carriers have been presented schematically: (a) Diffusion-controlled; (b) solvent-controlled; (c) polymer-degraded; (d) pH-sensitive; (from Son et al. [69]); Reprinted with permission from [69]. Copyright 2017 Springer.
Figure 2. Different drug release mechanisms from nano-carriers have been presented schematically: (a) Diffusion-controlled; (b) solvent-controlled; (c) polymer-degraded; (d) pH-sensitive; (from Son et al. [69]); Reprinted with permission from [69]. Copyright 2017 Springer.
Coatings 10 00568 g002
Figure 3. A summary of main factors influencing drug release kinetics.
Figure 3. A summary of main factors influencing drug release kinetics.
Coatings 10 00568 g003
Figure 4. Possible biological responses to different materials when placed in human body.
Figure 4. Possible biological responses to different materials when placed in human body.
Coatings 10 00568 g004
Figure 5. The interaction of bone and implant surface compared at different scales (Gittens et al. [149]); Reprinted with permission from [149]. Copyright 2011 Elsevier.
Figure 5. The interaction of bone and implant surface compared at different scales (Gittens et al. [149]); Reprinted with permission from [149]. Copyright 2011 Elsevier.
Coatings 10 00568 g005
Figure 6. Schematic presentation of surface modification of grade IV commercially pure titanium (cp-Ti). * Sa (the arithmetic mean height of the surface), ^ SLActive (Straumann Institute AG, Basel, Switzerland), $ TiUnite surface (Brånemark System, Nobel Biocare, Göteborg, Sweden), £ Osseospeed (Astra Tech, Dentsply, Waltham, MA, USA), & MicroVent (Zimmer Dental, Carlsbad, CA, USA), = Laser-Lok (BioHorizons, Birmingham, AL, USA).
Figure 6. Schematic presentation of surface modification of grade IV commercially pure titanium (cp-Ti). * Sa (the arithmetic mean height of the surface), ^ SLActive (Straumann Institute AG, Basel, Switzerland), $ TiUnite surface (Brånemark System, Nobel Biocare, Göteborg, Sweden), £ Osseospeed (Astra Tech, Dentsply, Waltham, MA, USA), & MicroVent (Zimmer Dental, Carlsbad, CA, USA), = Laser-Lok (BioHorizons, Birmingham, AL, USA).
Coatings 10 00568 g006
Figure 7. Presentation of various models showing antimicrobial activity of AMP: (a) Barrel-stave model, (b) carpet model, and (c) toroidal model [264]. Reprinted with permission from [264]. Copyright 2016 Elsevier.
Figure 7. Presentation of various models showing antimicrobial activity of AMP: (a) Barrel-stave model, (b) carpet model, and (c) toroidal model [264]. Reprinted with permission from [264]. Copyright 2016 Elsevier.
Coatings 10 00568 g007
Figure 8. Bio-functionalization of dental implants with surface modification and various interfaces [271] Reprinted with permission from [271]. Copyright 2011 Elsevier.
Figure 8. Bio-functionalization of dental implants with surface modification and various interfaces [271] Reprinted with permission from [271]. Copyright 2011 Elsevier.
Coatings 10 00568 g008
Table 2. List of various materials and biomolecules studied as potential therapeutic dental implant coating agents.
Table 2. List of various materials and biomolecules studied as potential therapeutic dental implant coating agents.
TypeSubgroupSubstance/BiomoleculeReferences
InorganicElementalNano-diamond[169,170,171]
Graphene [172,173]
Carbon nanotube[174,175,176,177]
Silver[178,179]
Ca-P[180,181,182,183]
Titanium [117,184]
OrganicProteinFibronectin[185]
Elastin[186]
Laminin[187,188]
Collagen[131,185,189]
Bone sialoprotein[185,189]
Osteopontin[190]
Growth factorsBone morphogenetic proteins[133,191,192,193]
PeptidesArginylglycylaspartic acid[131]
Parathyroid hormone[194,195,196]
Antimicrobial GL13K[197,198]
PolysaccharidesHyaluronic acid[193,199]
Chondroitin 4-sulfate[131]
Chitosan[58,200,201]
Pectin[179,202,203]
DrugsBisphosphonate[50,57,204,205]
Simvastatin[194,206,207]
Strontium ranelate[208]
Gentamycin[191,209]
Tetracycline [58]
Vancomycin[210,211,212]
Doxycycline[213,214]
Norfloxacin[215].
Chlorhexidine[58,216]
Table 3. List of key antimicrobial peptides (AMPs) present in the oral cavity [264].
Table 3. List of key antimicrobial peptides (AMPs) present in the oral cavity [264].
Antimicrobial PeptidesTypeSite of Expression
α-DefensinsHNP-1Neutrophils (azurophilic granules), gingival crevicular fluid, and bone marrow
HNP-2
HNP-3
HNP-4Neutrophils
β-DefensinshBD-1Saliva and suprabasal layer of stratified epithelium
hBD-2Gingival epithelium and saliva
hBD-3Skin and salivary gland
Histatin1Saliva (parotid and submandibular)
3
5
Adrenomedullin-Epithelium
CathelicidinsLL-37Neutrophils, inflamed epithelia, and saliva and submandibular glands

Share and Cite

MDPI and ACS Style

Zafar, M.S.; Fareed, M.A.; Riaz, S.; Latif, M.; Habib, S.R.; Khurshid, Z. Customized Therapeutic Surface Coatings for Dental Implants. Coatings 2020, 10, 568. https://doi.org/10.3390/coatings10060568

AMA Style

Zafar MS, Fareed MA, Riaz S, Latif M, Habib SR, Khurshid Z. Customized Therapeutic Surface Coatings for Dental Implants. Coatings. 2020; 10(6):568. https://doi.org/10.3390/coatings10060568

Chicago/Turabian Style

Zafar, Muhammad Sohail, Muhammad Amber Fareed, Samiya Riaz, Muhammad Latif, Syed Rashid Habib, and Zohaib Khurshid. 2020. "Customized Therapeutic Surface Coatings for Dental Implants" Coatings 10, no. 6: 568. https://doi.org/10.3390/coatings10060568

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop