1. Introduction
The International Plant Protection Convention predicted in 2021 a possible climate scenario for 2050 in which the global surface temperature will increase between 1.5
C and 2
C unless deep reductions of CO
are achieved in the following decades [
1]. Based on the latest report conducted by the international energy agency, this would imply that renewable energies should cover at least 70%, where the half is expected to be supplied by wind and sun [
2]. There is an implication that we will use PV systems, one of the fastest growing industries of renewable energies in recent years [
3]. Benefits are related to null emissions, avoidance of mechanical moving parts, and no generation of noise during its operation [
4].
A PV system is composed of several solar cells made of semiconductor materials where the role of these is to absorb photons to generate an electron-hole pair through a p-n junction [
5]. This action, which exposes an electron diffusion to produce voltage, is a complex process since not all the solar light spectrum is possible to be captured [
6]. Actually, this effect induces a PV conversion efficiency that tends to be lower than 20% [
7].
Solar cell technologies consider semiconductor materials such as types of crystalline, such as polycrystalline Silicon (poly-Si) and thin film type which are frequently produced from cadmium telluride (CdTe) or copper indium gallium selenide (CIGS). The CdTe’s major feature is its chemically stable composition which provides different production methods where the most popular at the moment is thin PV films [
8]. The CIGS is capable of providing a long-term reliability in terms of their degradation [
9]. Silicon solar cells can reach the highest among the three types which is around 15% [
10]. Considerable advances in efficiency improvement allowed the invention of Interdigitated back contact (IBC) n-type solar cells which reported a value up to 24.4% [
11]. However, IBC cells present a complex and expensive production method due to its novelty [
12]. Not only the efficiency of PV systems can be low but also, the end-user voltage is unstable and depends on the light intensity [
13].
A DC-DC converter can be linked to a PV to adjust the output voltage and current in a suitable operating point [
14]. As reported by Raghavendra et al. [
15], there are two main categories, which are isolated and non-isolated. The first mentioned refers to an electrical limit (such as a transformer) amid the inputs and outputs which allows the usage for high voltages. Examples of these types are flyback, forward, resonant, push-pull and bridge [
16,
17,
18,
19,
20]. In the non-isolated, the configuration indicates that the mentioned barrier is vanished and therefore, the efficiency tends to be higher since the number of components is lower [
21]. Known non-isolated architectures are Cuk, SEPIC, boost, buck-boost, positive superlift Luo, and ultra-lift Luo [
22,
23,
24,
25,
26,
27].
Since a PV setup has a low efficiency, the MPPT is an essential step because it helps the system to achieve the best overall performance [
28]. This can be generated through a designed control technique that can be embedded in a DC-DC converter [
29]. Therefore, in this paper, a revision of different MPPT for photovoltaic systems techniques are examined. Despite that, several authors provided reviews about MPPT methods for PV systems [
30,
31,
32], a major contribution of this work is the implementation of four of the revised algorithms in a real platform in combination with a neural reference generator. In regards to the PV test rig, because the solar panel had a low output-voltage, it increased with a boost converter that is known for this main feature [
33].
The article is summarized as follows.
Section 2 contains the analysis of different MPPT techniques with their advantages and disadvantages,
Section 3 shows the implementation of selected algorithms in a real PV rig which details are explained,
Section 4 exhibits the obtained results during the experiments and
Section 6 concludes with the major outcomes of this study.
2. Overview of MPPT Control Strategies
In 1954, a group of scientists from Bell Laboratories patented the first commercial solar cells with an efficiency of 6% [
34,
35]. Therefore in the same year, the MPPT was the objective of researchers to increase the efficiency and enhance the performance of this invention [
36]. Another involved reason was that the electricity produced by the PV system which changes along the time as the position of the sun is variable. Furthermore, the electricity produced by the PV system is dependent on solar light (irradiance) and environmental temperature [
37]. Thus, it becomes a significant challenge to harvest the MPPT of a PV system [
38].
Figure 1 summarizes the algorithms that had been highlighted in this review. Mainly there are two types of MPPT trackers: mechanical and electrical [
36]. In regards to the first type mentioned, which is also known as a “solar tracker”, it can increase the energy production up to more than 40% on average [
39]. Nevertheless, this configuration is recommended for industrial applications rather than for domestics due to the excessive cost involved of the mechanical tracking devices [
40].
On the other hand, electrical MPPT techniques are dependant on the power-voltage and linked to current-voltage curves to track the optimal operative point [
41]. Conventional curves for a PV system are revealed in
Figure 2 where the nonlinear feature is showed. Additionally, the MPP increases its complexity when the temperature, irradiation and partial shadowing vary to produce different curves with alternative shapes [
42,
43,
44]. Therefore, to force a PV system to work at the MPP, many algorithms were introduced by the researchers.
2.1. Offline Techniques
Known offline calculation algorithms advantages are related to their simplicity to be embedded and low computational demand [
45]. The mechanism is based on constant linear approximations to achieve the MPP. Fractional open-circuit voltage (FOCV) belongs to this group and focuses on the MPP through a proportional relation between the MPP voltage (
) and the open circuit voltage (
) [
46]. A similar approach is fractional short-circuit current (FSCC), which as its name suggests, it is related to a relation between the current at the MPP (
) and the short circuit current (
) [
47]. The accuracy of these methods is highly dependant on the proportional constant in which the FSCC has on a vastly with greater inaccuracies for MPPT [
48].
The FOCV method was implemented in experiments by Frezzetti et al. [
49] for a PV system. In this research, the authors used an adaptive scheme based on the irradiation to achieve acceptable results. FSCC has also been used in real time for a PV system based on the research made by Sher et al. [
50]. In the latter, a hybrid scheme linked to a P&O even-thought that the efficiency was lower than the conventional P&O.
2.2. Hill-Climbing Algorithms
Hill climbing (HC)-based algorithms are widely employed in research and industry due to their high efficiency with low computational requirements [
51]. These methods have the ability of avoiding the usage of empirical data for voltage and/or current tracking. Therefore, it is possible to achieve the MPP without a former knowledge of the PV features [
45]. The principle of HC is schematically explained through
Figure 3 where the slope calculation between power and voltage would give an idea about the position on the graph and thus, an action to be taken such as increasing or decreasing the voltage. In this section, main hill climbing algorithms like perturbation and observation (P&O), incremental conductance (INC), incremental resistance (INR), and drift-free (DF) are reviewed.
2.2.1. Perturb and Observation
This algorithm is based on an intentional and periodical perturbation on the control command with a following observation and evaluation of the system output [
52]. Applied to PV systems, the perturbation is generated through a change in the voltage
and current
, such that the power of the PV is measured. This implies that the slope
can be calculated, which helps with knowing whether the MPP is achieved, as
Figure 4 shows.
Based on the previous description and on the detailed logic of
Figure 4, the knowledge of
and
and its delay in
allows for the calculation of the slope. Therefore, if the latter mentioned value is positive, the duty cycle
d will increase such that the algorithm output
and aims to reach the MPP; on the contrary, when the position is at the right side of the MPP, the control signal decreases through
.
An interesting example of simulated implementation of P&O was carried out by Murtaza et al. [
53], where they used this algorithm for a two-stage coordinated PV system. Despite that this study lacks of experimental results, the authors showed that it is also effective in distributed systems. Another case where experiments were involved in a PV system showed that conventional P&O techniques are very sensitive to step size (which is related to the disadvantages of this method) [
51].
Despite the fact that P&O is one of the most popular MPPT algorithm in industry due to its simplicity [
54,
55]. Regardless of these assets, the major downsides are high chattering when the MPP is reached and the lack of success to achieve this point [
56]. The latter are majorly related to the changes in temperature and solar irradiance [
57].
2.2.2. Incremental Conductance
The incremental conductance technique is widely used for MPPT applications because it has higher accuracy in comparison to P&O. The calculation of the incremental change in conductance by evaluating the effect of voltage change [
58]. The conventional INC uses the slope of the P–V curve [
59]. The slope P–V curve at MPP is zero; the slope is positive when MPP is on the right side and negative when MPP is on the left side. The controller injects a slight change in the duty cycle and observes the behavior of the conductance [
60]. This algorithm was implemented in experimental conditions by authors of [
61], where they provided a regulated step size routine and the results showed a suitable performance. Disadvantages related to this scheme are reported to the trade-off between the system dynamics and the steady state accuracy that is managed within the controller tuning [
62]. The flowchart of the whole algorithm is shown in
Figure 5.
2.2.3. Incremental Resistance
Previously described algorithms worked in the power-voltage curve but alternatively, INR employs the power-current to determine the sign of the following perturbation [
63]. Differently to INC, the evaluation in this case is through the current change. Research by Raedani and Hanif conducted experimental implementation [
64]. The authors found that the convergence is slower than P&O and INC. The reported downsides of this method are related to the associated scaling factor for the change of reference voltage which can be complex to accomplish [
65]. A descriptive flow mechanism of this tool is displayed in
Figure 6.
2.2.4. Drift-Free
If a sudden change in irradiation occurs with any of the previous algorithms, it can happen that the new operative point lies on the opposite side of the MPP. For instance, an operative point that is in the left side of the MPP (based on a power-voltage curve), it can switch to the right side due to an irradiation change or likewise for the opposite situation. This effect is known a drift which can be harsh if large step-sizes are used [
63]. Nevertheless, Kili et al. [
66] proposed a modified P&O algorithm to overcome the drift where the mechanics is based on the addition of a new parameter that figures if the power change is produced by intentional (due to algorithm) or by irradiance. The procedure of this algorithm is explained in
Figure 7. A basic experiment carried by Mathew et al. was found where they used a drift-free algorithm [
67]. The authors found that the algorithm behaved better than INC under changing operative conditions.
In regards to the advantages, this algorithm can deal with unexpected irradiance variations with high efficiency in terms of the lost power [
68]. Nevertheless, the downsides occur when the load varies since it is ignored. A solution for this problem was proposed by Jately et al. [
63], although the algorithm and number of variables are higher.
2.3. Intelligent Techniques
Intelligent techniques are aimed to provide high performance in comparison to previous described ones. In this sense, the features are related to fast responses, overshoot avoidance and low fluctuations in irradiance or temperature changes so that the operative point can stay at the MPP [
69]. In this section, the algorithms to be revised are fuzzy logic control (FLC), particle swarm optimization (PSO) and genetic algorithm (GA).
2.3.1. Fuzzy Logic Control
FLC is based on the human experience rather than knowledge of the system’s mathematical model [
70]. In this review paper, type-1 fuzzy (which structure is displayed in
Figure 8) sets are revised which mechanism comprises a fuzzification, an inference and a defuzzification block [
71]. The fuzzification role is to map the inputs to a fuzzy variable [
72]. Later the inference block is where the real data from an expert takes places through membership rules within if-then statements [
73]. Finally, the output takes places in a defuzzification process where the linguistic rules of the inference are translated into numerical crisp values [
74].
The authors of [
75] showed (through a simulation case) that FLC combined with P&O is capable of dealing with drifting. In real-time systems, Bakkar et al. made an implementation in a commercial PV [
76]. In this case, they used a commercial PV with a flyback converter, commonly employed for low power applications [
77]. Results of this experiment showed that the stability and fast response could be achieved.
The mentioned features of FLC allows concluding that a main advantage of this approach is that a mathematical model is unnecessary for the control tuning since it can be based on trial and error made by the designer [
78]. Disadvantages are dependant on the available computational resources since the requirements will be higher as long as the number of rules are higher [
79]. An example of this is with adaptive neuro-fuzzy inference system (ANFIS) which is a fuzzy approach based on neural networks [
80]. In this latter, an improved simulation results were obtained for an MPPT approach in a PV system. Nevertheless, the computational costs are too high for implementation in real-systems [
81].
2.3.2. Particle Swarm Optimisation
This stochastic method was developed on basis of the biological behavior of fish and bird flocks during travel when they are seeking food [
82]. The animals are represented by multiple particles that are looking for a suitable path while they exchange information about the search among themselves [
31]. Therefore, each particle position converges to a particular solution for a right path which are all evaluated and the best particle experience (
) within the best global one (
) [
83]. Equations (
3) and (
4) are the mathematical representation for the velocity
and position
of each particle where
and
are the cognition coefficients to accelerate the particles to the suitable paths [
84]. The parameter
is called the inertia weight whereas
and
are arbitrary variables that belong in the range [0, 1] [
85].
In the case of a PV system, the particle position is considered to be the duty cycle of the DC-DC converter and the velocity is the duty-cycle change [
86]. The PSO algorithm is used for solving complex problems and optimization through a simple procedure that achieves high speed convergence [
87]. However, one of the main issues is related to the high probabilities to fall in a local optimal point [
88]. Additionally, the implementation in real time systems is complex since optimization algorithms require high computation time [
89]. A particular solution can be through offline tuning in a high fidelity model. Al-Majidi et al. [
90] provided this solution with a neural model trained with experimental data. Parameters were obtained through PSO and later an experimental test was configured to confirm the reliability of the strategy.
2.3.3. Genetic Algorithm
Based on Darwin’s natural principle, GA mechanics choose random potential solutions within a compatibility criterion [
91]. This heuristic search method chooses a random generation for the creation of a later one and each is concerned with a fitness value [
92]. There are two main operators for this case where the first one is the selection, in which the procedure is to pick the best chromosomes (bad ones are neglected) that will propagate a forward generation. The following operator is the reproduction that chooses two chromosomes from an ongoing generation to obtain individual for a future generation [
93].
The mathematical mechanics are described in Equations (
5) and (
6), where an objective function
is has constraints
till the total number
m as shown and a modification of this function defined as
[
94]. The constant K penalises the influence the following generation. As an example, the integral of the absolute error (IAE) can be a suitable objective function for MPPT [
95].
The GA is capable of avoiding being stuck in local MPP as it works with condition which can be related to this condition [
96]. This implies that it is able to work under a partial shadowing condition [
97]. Nevertheless, this algorithm requires a huge amount of computational resources due to the iterative and constrained calculation [
98]. This can also be mirrored at hardware implementation as in Attarmoghaddam et al. [
99] where they only implemented one GA module.
2.4. Other Techniques
In this section, additional techniques are summarized. The structures described in this section are sliding mode control (SMC), which is as a robust controller widely used in uncertain systems, and model predictive control (MPC), as a prediction-optimization scheme. Since an error is involved in these schemes, the explanations were based on current tracking to achieve the MPPT. The error is defined in Equation (
7) where
and
are MPP current and the PV output current, respectively.
2.4.1. Sliding Mode Control
SMC belongs to a robust control category since it is capable of dealing with parameter uncertainties, the design is simple and it has finite time convergence [
100,
101,
102]. Based on Kihal et al. [
103], three steps are necessary to achieve a suitable design:
Equation (
8) is the surface used for the following explanation. It is a proportional-integral surface that should accomplish with the Hurtwitz condition to guarantee that the error tends to zero when the system reaches a null value surface [
104]. The parameter
is a design value that should be tuned during experiments.
The control signal of a SMC is composed of an equivalent
and a switching term
, which are established in Equation (
9). The first mentioned is achieved based on the condition
[
28]; the switching, which guarantees robustness, is expressed in Equation (
10).
Based on the DC-DC boost converter model that was used in previous research [
105], obtaining the equivalent control signal implies that the surface derivative should be equal to zero. Therefore, as the error was formerly expressed in Equation (
7), and with the usage of the system (gathered from the authors previous work [
24], the equivalent control term is achieved as follows.
In the experimental field, this method was tested in PV systems by authors of [
106]. In this research, the authors implemented a SMC on a distributed MPPT that belonged to an electrical grid. Outcomes showed a proper accomplishment of the MPP with a correct control signal to avoid the system damaging.
Despite the mentioned advantages at the beginning of this section, disadvantages of SMC are related mainly to the switching feature of this method. Chattering is one of the most well-known disadvantages and it is caused because the switching is finite in real systems and due to unmodeled dynamics [
107]. This effect not only increases the energy consumption of the system but also the actuators detriment [
108].
2.4.2. Model Predictive Control
MPC is a method of constrained control that is based on the principles of feedback structures and numerical optimization [
109]. Through the usage of a system that is capable of capturing the involved dynamics, MPC uses this tool to predict future states and select an optimized control action that can accomplish a determined performance index and defined constraints [
110].
For this case, a discrete state-space model of the boost converter is obtained by means of the forward Euler approximation [
111] given in Equation (
12). Therefore, the discrete-time state-space model of the boost converter can be written as Equation (
13).
The designed MPC seeks for the error minimization among the predicted current value and the desired reference. The future path of the states is achieved by the established dynamical system which are controlled through the prediction horizon. In this case, it was settled at a value of 2. The usage of Equations (
14) and (
15) allows the calculation of the controlled variable
at each time
. Thus, a cost function is associated with this objective which can be achieved through the numerical reduction of
J, expressed in Equation (
16). Since the authors applied an MPC in previous works, further mathematical details can be found in [
112].
In terms of implementation, it was found that this method was implemented for a PV grid system by authors of [
113]. They used an MPC, which was contrasted against a PID and outcomes displayed an increment of performance even during the appearance of disturbances.
MPC advantages are related to its robustness because it is capable of dealing with constraints and uncertainties [
114]. Additionally, as it depends on a mathematical system, it is an intuitive method [
115]. Nevertheless, since several operations are being performed at the same time such as optimization and prediction, this method is very sensitive to time parameters (like prediction horizon) because it can increase dramatically the computational time [
116].
2.5. A Brief Resume of the Reviewed Techniques
Previous analysis settled to conclude a brief summary of MPPT techniques. The assets and weaknesses of each structure of the mentioned frameworks are concise in the following
Table 1. Nevertheless, extra details were obtained in the following sections where experiments were performed in a real PV system.
3. Experimental Case Study
In this section, four different MPPT algorithms were implemented and studied in a real PV system. The selection of the algorithms was based on the review previously made. In this sense, from the HC techniques, we selected the most used one that is P&O) which was compared with FLC, SMC, and MPC. Offline was not considered to be sufficient as non-linearities were expected during the experiments. Since SMC and MPC required a reference current/voltage that corresponded to the MPP, this was obtained via different techniques of previous works [
117,
118,
119,
120,
121,
122,
123]. However, most of these approaches have a lack of accuracy which results in a low tracking efficiency. In this work an artificial neural network (ANN) was designed to obtain the reference current
that corresponded to the MPP. First, different structures such as feed forward (FF), radial basis (RB), deep FF, etc., were tested to obtain an accurate prediction of
. However, a recurrent neural network (RNN) was finally selected since it provided high accuracy for both training and validation performance.
3.1. Hardware Description
The hardware workflow involved in the experiments is shown in
Figure 9. The PV panel was a commercial type manufactured particularly for residential and small industrial installations. The technical information of this device is listed in
Table 2. Regarding the power converter, a DC-DC high step up type TEP-192 manufactured by the research group of Huelva University (Spain) was used. This hardware is an adaptation stage circuit that is inserted between the load and the PV generator. It is usually desired not only for boosting the PV low voltage, but also to provide regulated output voltage for end use. The characteristics of the device used in this work are provided in
Table 3. To test the performance of the controllers, a programmable load resistance type 8500B manufactured by BK Precision Corporation (Yorba Linda, CA, USA) was used. The technical specifications of this device are listed in
Table 4. A MicroLabBox dSPACE DS1202 (DT Techsolutions Pte Ltd., Singapore CITY, Singapore) also was used for the acquisition and control signal generation. This device has various channels for the communication with the host PC and the converter. The configuration of these channels can be made via its real-time-interface libraries. Additional equipment such as the irradiation and temperature sensors, as well as the ControlDesk software for the visualisation, were also used in the experiments.
3.2. Recurrent Neural Network
A RNN is a class of artificial neural networks that uses information from the previous iteration to ameliorate the performance of the NN in current and future inputs. In comparison with other networks, it can be said that RNN is unique because is the only network that contains a hidden state (memory) and loops. This structure allows the RNN to store past information in the hidden state and operate on sequences. In other words, it gets part of its output as an input for the next time step. These features are well suited for solving different problems with sequential data of varying length. Different RNN architectures, such as fully recurrent (FRNN), long short-term memory (LSTM), gated recurrent units (GRUs), etc., were introduced in recent decades. Due to its simplicity, the RNN configuration were used in many filtering and modeling applications. The hidden layer and the output of the RNN can be calculated using Equation (
17).
where
,
,
, are, respectively, the input vector, the hidden layer vector, and the output vector;
W,
U, and
b, are parameter matrices and vector;
and
are activation functions, respectively, given in Equations (
19) and (
20).
To train the RNN model, we selected the temperature and irradiation as two input feature vectors while the output is the reference current vector
that corresponds to the ongoing of the MPP. The dataset used in this work contains 796 normalized samples where 70% was used for the training, 15% for the validation and 15% for the test. Different training algorithms were checked so as to obtain an accurate model. Finally, we set the configuration of the LRN with the following parameters: training algorithm = Levenberg-Marquardt (LM), learning rate = 0.1, hidden layers = 2, neurons = 41, maximum epochs = 5000. The training performance was measured using mean square error (MSE, defined in Equation (
21)), where the error is the difference between the predicted output and the target, and
N is the number of training data. The predicted output, the target and the error are presented in
Figure 10.
The performance of the trained model can be analyzed using the regression values presented in
Figure 11; where R represents the output-target relationship, which is ranged between 0 and 1 (0: low accuracy, 1: ideal accuracy). According to
Figure 11, it is clear that the obtained RNN model is characterised by high prediction accuracy since the R values for training, validation and test are, respectively, equal to 0.99566, 0.99521 and 0.9936.
The characteristics of the current corresponds to the MPP for each temperature and irradiation, which are plotted in
Figure 12. According to this figure, it is noticeable that the highest currents (yellow area) are found at high irradiation and low temperature, a reduction in the current can be occurred via an increase in temperature or via a decrease in irradiation. Moreover, the results from this figure show that the current is hardly affected by the irradiation in comparison with the temperature. Hence, for a constant irradiation and by increasing the temperature from 0
C to 50
C, the current of the maximum power is decreased around 2 A. On the other hand, for a constant temperature and by decreasing the irradiation from 900 W/m
2 to 100 W/m
2, the current of the maximum power is decreased around 7 A.
5. Discussion
This review article presented an analysis of several types of MPPT methods for PV systems linked to a DC-DC boost converter. This is an important and cutting-edge topic since it allows to provide the maximum performance of energy conversion in solar cells, which are widely used as an efficient renewable energy.
In the first part, it was seen that there are two main categories of MPPT, mechanical and electrical. An initial option are mechanical ones which are far better for industrial environments, although the initial investment is high. Nevertheless, in alternative situations, the MPPT can also be achieved through a control law that can be designed for a DC-DC boost converter that provides a PWM signal. In this sense, four categories were analyzed based on previous studies. Offline techniques such as FOCV and FSCC are the most simple to implement since these are based on linear approximations. Nevertheless, PV systems tend to have nonlinear behaviour because of the weather conditions (like temperature, irradiation and shadowing) that vary along each day.
A further step was analyzed in the HC algorithms (P&O, INC and INR) which principle is to locate the MPP by means of the power-voltage slope sign. Despite that the implementation and computational requirements are simple and low, the major disadvantage resides on the problems due to partial shadowing. The latter effect produces local MPP and the algorithms tend to fall in this place rather than in a global one. Furthermore, other issues are related to sudden changes in the load in advanced algorithms like Drift-Free, which is its weak-point.
Intelligent techniques can be capable of dealing with previously mentioned downsides of HC algorithms. PSO is a stochastic process that is capable of dealing with complex problems through a simple optimization and fast convergence. A problem found in the literature review of this method is the risk of falling in a local MPP. A similar approach studied was GA, which is based on biological principles of evolution; this frameworks is capable of avoiding the local maximum issue. Nevertheless, because PSO and GA are optimization methods, they require high computational resources in the case of implementation in hardware. Another intelligent technique analyzed was FLC, of which the principle is rather based on the designer’s experience, which provides a tuning from the knowledge of the system. Nevertheless, the deficiency of this technique arises whenever the membership functions need to be increase and this induces a high load in the computational resources.
Other common control techniques were reviewed, such as SMC and MPC. Despite the chattering issue which generates energy consumption and reduces the lifespan of actuators, it was found that SMC is a robust strategy when system uncertainties are present. The last analyzed approach was MPC, which a model-based controller that is capable of generating a control action from an optimization gathered from future predictions and constraints. Major disadvantages of the latter are related on the numerical capabilities of a hardware to compute the optimization.
After the revision of several algorithms for MPPT, four of them were chosen to be implemented in an experimental PV platform with commercial hardware. Since the weather conditions varied for every experimental test, the analysis of each was performed individually without a graph overlapping. The tests were also carried with variable load to check each controller capabilities. P&O was the first to be implemented as one of the most used ones in industry; its efficiency for robustness at load variations was demonstrated, but it also showed chattering and had difficulties to deliver low-power. The second implementation was carried with SMC which was easy to embedded and out-came with enough robustness, although the chattering was significant. The third try was with FLC, which was capable of showing a reduction of power consumption as a consequence of chattering decline. Nevertheless, the disadvantages appeared with the robustness deficiency at the disturbance change due to the variable load. The last tested controller was MPC which was known by the authors due to previous experience. In this sense, the results showed outstanding performance in resemblance to the former structures. With a simple configuration that could avoid the computational saturation of the hardware, the outcomes displayed high accuracy and robustness.
For future perspectives as guidelines, the authors expect to test different designs in order to enhance the obtained structures. A testing of the hardware capabilities in terms of the MPC can be performed, although this can induce delays and damage risks in the equipment. Linked to previous suggestion, the implementation of optimization algorithm such as PSO or GA can be performed but with certain limitations in computational resources. Additional tests such as Hammerstein-Wiener nonlinear system identification tools or nonlinear auto-regressive exogenous models can be used as alternatives to ANNs.