Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
Next Article in Journal / Special Issue
Optimal Siting and Sizing of Distributed Generators in Distribution Systems Considering Cost of Operation Risk
Previous Article in Journal
A Carbon Price Forecasting Model Based on Variational Mode Decomposition and Spiking Neural Networks
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Capacitor Voltage Ripple Suppression for Z-Source Wind Energy Conversion System

College of Electrical and Information Engineering, Hunan University, Changsha 410082, China
*
Author to whom correspondence should be addressed.
Energies 2016, 9(1), 56; https://doi.org/10.3390/en9010056
Submission received: 8 December 2015 / Revised: 12 January 2016 / Accepted: 13 January 2016 / Published: 19 January 2016
(This article belongs to the Special Issue Distributed Renewable Generation)

Abstract

:
This paper proposes an improved pulse-width modulation (PWM) strategy to reduce the capacitor voltage ripple in Z-source wind energy conversion system. In order to make sure that Z-source capacitor voltage has symmetrical maximum and minimum amplitudes in each active state, the shoot-through time is divided into six unequal parts. According to the active state and zero state, the shoot-through time is rearranged to match the charging time and discharging time of the Z-source capacitors. Theoretically, it is indicated that the voltage ripple of the Z-source capacitors can be reduced effectively by means of the proposed PWM scheme. Finally, simulation and experimental results are given to verify the performance of the presented method.

1. Introduction

In recent years, wind energy conversion systems (WECSs) have attracted more and more interest from researchers and engineers on a global scale. In the work of Jamil et al. [1], a traditional conversion system including a diode rectifier and a three-phase inverter is presented. In spite of the merits, such as simple construction and low cost, the bus voltage in such a system is relatively high due to the buck voltage characteristics of the voltage source inverter. This leads to an influence on the operational range of the wind power generation with variable speed and constant frequency. To solve this problem, a boost dc–dc converter is introduced between the diode rectifier and three-phase inverter [2,3,4,5,6]. However, the two-stage structure will result in efficiency reduction and total costs increase of the conversion system.
As a novel and attractive technology for power electronic conversion [7,8,9,10], the Z-source inverter (ZSI) can either boost or buck its output voltage in a single stage without an extra power switch. In addition, the reliability of the inverter is substantially improved, because the shoot-through state, forbidden in voltage source inverter, is feasible in ZSI. Moreover, the output voltage distortion of the inverter is reduced, since there is no need to set dead time. As a result, the Z-source inverter is widely used in wind power and other renewable energy power generation systems in recent years [11,12,13,14].
However, the additional Z-source network greatly increases the size and weight of the system to which it is connected. Therefore, there are difficulties in equipment installation and transportation. At the same time, the system power density is also reduced. Recently, some research has shown that the size of Z-source capacitors can be reduced by ZSI topology improvement. Anderson et al. [15] proposed a quasi-Z-source inverter which reduces one capacitor voltage stress of Z-source network. Compared to the previous Z-source inverter, the quasi-Z-source inverter is smaller and cheaper under the same operating conditions. Moreover, an improved Z-source inverter topology is presented in [16]. In comparison with the traditional Z-source inverter, the capacitor voltage stress of the Z-source network is reduced greatly with the same voltage boost ability, as the DC-side diode and inverter bridge are transposed. Thus, the low-voltage capacitors can be utilized to achieve a reduction in system volume and costs. Additionally, an enhanced Z-source inverter comprised by four inductors, two capacitors, and seven diodes is proposed in [17]. With more passive components utilized, it can also reduce the Z-source capacitor voltage stress in higher power density. Although the mentioned structures are suitable for different specific applications [18], it is significant that the capacitor voltage stress of the Z-source inverter can be reduced by improved pulse width modulation (PWM).
In the traditional PWM strategy for a Z-source inverter, the shoot-through time interval is divided into six equal parts [19]. However, it needs to use relatively large capacitors to cope with the problem of different maximum and minimum amplitudes of the Z-source capacitor voltage, which thus results in increased ripple in capacitor voltage. In this paper, an improved PWM strategy is proposed. The shoot-through time is divided into six unequal parts to suppress capacitor voltage ripple in a Z-source network. The operating principle of the improved pulse width modulation strategy is analyzed in detail, and the comparison of Z-source capacitor voltage ripple under existing and improved pulse width modulation strategy is provided. Simulations and experiments are demonstrated to verify the performance of the proposed PWM strategy.

2. Working Principle

2.1. System Structure and Model Analysis

The configuration of the Z-source grid-connected wind generation system is shown in Figure 1. This system consists of the wind turbine, the permanent-magnet synchronous generator (PMSG), the diode rectifier, the Z-source inverter, and the grid-connected transformer.
Figure 1. The topology of Z-source grid-connected wind generation system. PMSG: permanent-magnet synchronous generator.
Figure 1. The topology of Z-source grid-connected wind generation system. PMSG: permanent-magnet synchronous generator.
Energies 09 00056 g001
As shown in Figure 2, the inverter bridge is equivalent to a current source when it works in the non-shoot-through zero state. Consider the symmetry of the Z-source network [20], we have:
V C 1 = V C 2 = V C   V L 1 = V L 2 = V L
where VC1, VC2 are the voltage of Z-source capacitors, and VL1, VL2 are the voltages of Z-source inductors.
From the equivalent circuits shown in Figure 2, the equations can be obtained as follows:
{ I D = 2 I L I i V i n = V L + V C V i = 2 V C V i n d I L d t = V i n V C L Z
where ID is the current through D7, IL is the current through the Z-source inductor, Ii is the equivalent current through the inverter bridge, Vin is the output voltage of the diode rectifier, Vi is the input voltage of the inverter bridge, and LZ is the inductance of the Z-source inductor.
Figure 2. Equivalent circuit of the Z-source inverter (ZSI) in the non-shoot-through zero state.
Figure 2. Equivalent circuit of the Z-source inverter (ZSI) in the non-shoot-through zero state.
Energies 09 00056 g002
As illustrated in Figure 3, the inverter bridge is equivalent to a short circuit when it operates in the shoot-through zero state. In this case, the diode D7 is in the OFF state. From Figure 3, the following equations are obtained:
{ V L = V C d I L d t = V C L V i = 0
Figure 3. Equivalent circuit of the Z-source inverter in the shoot-through zero state.
Figure 3. Equivalent circuit of the Z-source inverter in the shoot-through zero state.
Energies 09 00056 g003
In steady state, it is noticed that the average voltage of the Z-source inductors in one switching period is zero. According to Equations (2) and (3), it can be calculated as:
V C V i n = T T 0 T 2 T 0 = 1 D 0 1 2 D 0
where T0 is the time of shoot-through zero state in a switching period, and D0 is the shoot-through duty cycle.
Based on Equations (3) and (4), it can be obtained by:
V D = 2 ( 1 D 0 ) 1 2 D 0 V i n = ( 1 + 1 1 2 D 0 ) V i n 2 V i n
where VD is the voltage of diode D7.
In Equation (5), we can clearly see that diode D7 will be shut off when the Z-source inverter is in the shoot-through zero state. In this case, the Z-source network can no longer get power from the PMSG.
In the non-shoot-through zero state, from Equations (2) and (4), we have:
d I L d t = 2 3 D 0 L Z ( 1 2 D 0 )
In the shoot-through zero state, from Equations (3) and (4), it can be obtained that:
d I L d t = 1 D 0 L Z ( 1 2 D 0 )

2.2. Traditional PWM Strategy for ZSI

In traditional ZSI PWM strategy, the shoot-through time is divided into six equal parts. They are distributed to the adjacent active state vectors and both sides of the zero vectors. The traditional PWM scheme for ZSI is shown in Figure 4, where TS represents a switching period, TZ is the zero state time in a switching period, T0 is the shoot-through time in a switching period, T1 and T2 are the active state time in a switching period, Tsh is one-sixth of T0, and t1t6 are the moments of switching operations in a half of a switching period.
Figure 4. Diagram of traditional pulse-width modulation (PWM) scheme for ZSI.
Figure 4. Diagram of traditional pulse-width modulation (PWM) scheme for ZSI.
Energies 09 00056 g004
The diagram of Z-source capacitor voltage ripple with the traditional PWM scheme is shown in Figure 5. It can be seen that the Z-source inductor is charged by the Z-source capacitor when the Z-source inverter works in the shoot-through zero state, which can decrease the voltage of the Z-source capacitor. However, the voltage will increase as the capacitor is charged by the inductor when the Z-source inverter operates in the non-shoot-through zero state. Since the shoot-through time is equally distributed to the adjacent state vectors, the capacitor voltage has identical decreasing time, while the increasing time is determined by the non-shoot-through zero state. Therefore, the Z-source capacitor voltage ripple is not optimized.
Figure 5. Diagram of Z-source capacitor voltage ripple with traditional PWM scheme.
Figure 5. Diagram of Z-source capacitor voltage ripple with traditional PWM scheme.
Energies 09 00056 g005
From Figure 5, the moments of switching operations can be calculated by:
{ t 1 = T Z 4 3 T s h 2 t 2 = T Z 4 T s h 2 t 3 = t 2 + T 1 2 t 4 = t 3 + T s h t 5 = t 4 + T 2 2 t 6 = t 5 + T s h
The Z-source capacitor voltage from t1 to t6 can be expressed as follows:
{ V C ( t 1 ) = V C + 2 3 D 0 L ( 1 2 D 0 ) t 1 V C ( t 2 ) = V C ( t 1 ) 1 D 0 L ( 1 2 D 0 ) ( t 2 t 1 ) V C ( t 3 ) = V C ( t 2 ) + 2 3 D 0 L ( 1 2 D 0 ) ( t 3 t 2 ) V C ( t 4 ) = V C ( t 3 ) 1 D 0 L ( 1 2 D 0 ) ( t 4 t 3 ) V C ( t 5 ) = V C ( t 4 ) + 2 3 D 0 L ( 1 2 D 0 ) ( t 5 t 4 ) V C ( t 6 ) = V C ( t 5 ) 1 D 0 L ( 1 2 D 0 ) ( t 6 t 5 )
And the Z-source capacitor voltage ripple is the maximum value of six peaks within half a switching period, which can be described as:
V C r i p p l e = max ( | V C ( t 1 ) V C | , | V C ( t 2 ) V C | , | V C ( t 3 ) V C | , | V C ( t 4 ) V C | , | V C ( t 5 ) V C | , | V C ( t 6 ) V C | )

2.3. Improved PWM Strategy for ZSI

In this paper, an improved PWM strategy is proposed to minimize Z-source capacitor voltage ripple. In contrast to the traditional scheme, the shoot-through time of the proposed method is divided into six unequal parts. And they are distributed to the adjacent active state vectors and both sides of the zero vectors. The total shoot-through time in a switching period is kept constant, because of its influence on the boost voltage ability. Meanwhile, the active states are maintained the same, because the shoot-through zero states only take parts of zero states. It is obvious that the arrangement of the shoot-through time affects the voltage of the Z-source capacitor. Therefore, the Z-source capacitor voltage ripple can be optimized.
In Figure 6, the improved PWM scheme for ZSI is shown, where Ta, Tb, and Tc are the reassigned shoot-through time according to the increasing and decreasing time of the Z-source capacitor voltage. The sum of Ta, Tb and Tc is half of the total shoot-through time in a switching period. The diagram of Z-source capacitor voltage ripple with improved PWM scheme is illustrated in Figure 7, where a, b, and c are the increased values of the Z-source capacitor voltage. From Figure 7, the following equations can be obtained:
{ | V C ( t 2 ) V C | + | V C ( t 3 ) V C | = a | V C ( t 4 ) V C | + | V C ( t 5 ) V C | = b | V C ( t 6 ) V C | + | V C ( t 1 ) V C | = c
On the basis of Equations (10) and (11), the Z-source capacitor voltage ripple can be expressed as:
V C r i p p l e max ( a 2 , b 2 , c 2 )
In order to minimize the ripple of the Z-source capacitor voltage, the following equations should be established:
{ | V C ( t 2 ) V C | = | V C ( t 3 ) V C | = a 2 | V C ( t 4 ) V C | = | V C ( t 5 ) V C | = b 2 | V C ( t 6 ) V C | = | V C ( t 1 ) V C | = c 2
And the decreased values of the Z-source capacitor voltage in shoot-through time Ta, Tb, and Tc are:
{ Δ V C T a = c 2 + a 2 Δ V C T b = a 2 + b 2 Δ V C T c = b 2 + c 2
Therefore, the shoot-through time Ta, Tb, and Tc can be obtained as:
{ T a = ( a + c ) 4 ( a + b + c ) T 0 T b = ( a + b ) 4 ( a + b + c ) T 0 T c = ( b + c ) 4 ( a + b + c ) T 0
As a, b, and c are proportional to the corresponding state time, it can be expressed as:
a : b : c = T 1 2 : T 2 2 : T Z T 0 2
From Equation (16), it can be calculated as:
{ T a = T 0 4 ( T a T 0 ) ( T Z + T 1 T 0 ) T b = T 0 4 ( T a T 0 ) ( T 1 + T 2 ) T c = T 0 4 ( T a T 0 ) ( T Z + T 2 T 0 )
The maximum and minimum values of Z-source capacitor voltage are kept equal in each active state. In the same working conditions, the Z-source capacitor voltage ripple is reduced. Therefore, smaller capacitors can be utilized under the same ripple requirements.
Figure 6. Diagram of improved PWM scheme for ZSI.
Figure 6. Diagram of improved PWM scheme for ZSI.
Energies 09 00056 g006
Figure 7. Diagram of Z-source capacitor voltage ripple with improved PWM scheme.
Figure 7. Diagram of Z-source capacitor voltage ripple with improved PWM scheme.
Energies 09 00056 g007

2.4. Control Strategy of the Z-Source Grid-Connected Wind Generation System

Generally, the double closed-loop controller, including the voltage outer-loop and current inner-loop, is always adopted in the existing three-phase voltage-source inverter for grid connection [21]. Based on this, the control system of the proposed Z-source grid-connected wind generation also combines the double closed-loop controller, which includes the speed outer-loop and current inner-loop. From Equations (3) and (4), the average dc voltage on the inverter bridge can be expressed as:
V i = [ T 0 × 0 + T 1 × ( 2 V C V in ) ] / T   = T T 0 T 2 T 0 V i n = 1 D 0 1 2 D 0 V i n = V C
It can be seen that the average dc voltage on the inverter bridge will remain stable as long as the Z-source capacitor voltage stays constant when the shoot-through duty cycle is fixed. Therefore, the Z-source capacitor voltage is controlled directly in voltage outer-loop. And the speed of the PMSG can be controlled flexibly by controlling the shoot-through duty cycle when the Z-source capacitor voltage remains stable.
In this paper, the current control based on the synchronously rotating coordinates is utilized in the current inner-loop. The d-axis of the d–q coordinates is made being coincided with the grid voltage vector E . Thus, the following can be obtained:
{ e d = E e q = 0
The double value logical switch function SK (K = a, b, c) is defined as:
  • when SK = 1, the top switch of the phase leg is being turned on and the bottom switch of the phase leg is being turned off;
  • when SK = 0, the top switch of the phase leg is being turned off and the bottom switch of the phase leg is turned on.
Through the synchronous rotating transformation, it can be expressed as:
{ L d i d d t = R i d + ω L i q + e d S d V i n L d i q d t = R i q + ω L i d + e q S q V i n C d V C d t = 3 2 ( i q S q + i d S d )
where ed and eq are the d-axis and q-axis component of the electromotive force vector of the grid, respectively; id and iq are the d-axis and q-axis component of the grid current vector, respectively; and Sd and Sq are the quantities transformed by Sa, Sb, and Sc in the synchronously rotating coordinates.
The state feedback decoupled control is applied to achieve good performance. The output voltage of the Z-source inverter can be expressed by:
{ v q = ( K P + K I s ) ( i q * i q ) ω L i d + e q v d = ( K P + K I s ) ( i d * i d ) + ω L i q + e d
where KP and KI are the P-gain and I-gain of the PI controllers, respectively; vd and vq are the d-axis and q-axis component of the output voltage vector of the Z-source inverter, respectively; and id* and iq* are the d-axis and q-axis component of instruction current vector of the grid, respectively.
The mechanical power delivered by a wind turbine is expressed as [6]:
P m e c h = 0.5 C P ( λ , β ) π ρ r 2 v w 3
where CP is the power coefficient defined as the ratio of turbine power to wind power and depends on the aerodynamic characteristics of blades. ρ is the air density, r is the radius of the turbine blades, vw is the wind velocity.
The tip speed ratio λ is defined as:
λ = r ω s v w
where ωs is the angular speed of the rotor.
The wind speed and wind turbine angular speed is proportional when the state of the wind machine is running at the optimum tip speed ratio:
v w = r ω s λ o p t
where λopt is the optimum tip speed ratio.
The maximum power output by the wind turbine is given by:
P max = 0.5 ρ C P max π r 2 ( r ω s λ o p t ) 3 = K o p t ω s 3
and then the maximum torque is:
T max = P max ω s = K o p t ω s 2
where Kopt is a constant determined by the wind turbine characteristics.
Figure 8a is mechanical power versus rotor angular speed curves calculated by Equation (25). Figure 8b is mechanical torque versus rotor angular speed curves calculated by Equation (26).
Figure 8. Wind turbine characteristics (a) Mechanical power versus rotor angular speed; (b) Mechanical torque versus rotor angular speed.
Figure 8. Wind turbine characteristics (a) Mechanical power versus rotor angular speed; (b) Mechanical torque versus rotor angular speed.
Energies 09 00056 g008
The instruction shoot-through duty cycle is determined by controlling the Z-source inductor current, and the inductor instruction current is determined by speed controlling of the PMSG. The structure of the control system for Z-source grid-connected wind generation is shown in Figure 9.
Figure 9. The control system of three-phase Z-source grid-connected inverter.
Figure 9. The control system of three-phase Z-source grid-connected inverter.
Energies 09 00056 g009

3. Simulation and Experimental Results

In order to verify the theoretical analysis, simulation model and experimental system are established based on the following parameters:
(1)
Rated speed of PMSG: 1500 RPM;
(2)
Rated capacity: 7.5 kW;
(3)
Grid line-line voltage: 380 V/50 Hz;
(4)
Z-source capacitor voltage: 573 V;
(5)
Capacitance of Z-source capacitor: 1000 μF;
(6)
Inductance of Z-source inductor: 1.5 mH.
The simulation waveforms with traditional PWM scheme in 0.2 s are shown in Figure 10, where the output three-phase current, the Z-source inductor current, the input voltage of the inverter bridge, and the Z-source capacitor voltage are included. It can be seen that the grid-connected current is a sinusoidal wave; the input voltage of inverter bridges is controlled at 637 V; the Z-source inductor current is relatively stable; the maximum voltage ripple through the Z-source capacitor is about 6 V. The simulation waveforms with traditional PWM scheme in a switching period is shown in Figure 11. It can be seen that there are 6 equal shoot-through states in a switching period. Therefore, Z-source capacitor voltage has equivalent decreasing time, while the increasing time of Z-source capacitor voltage is determined by the non-shoot-through zero state. The Z-source capacitor voltage ripple is relatively large.
The simulation waveforms with improved PWM scheme in 0.2 s are shown in Figure 12. It can be seen that the grid-connected current is a sinusoidal wave; the input voltage of inverter bridges is also controlled at 637 V; the Z-source inductor current is relatively stable; the maximum voltage ripple through the Z-source capacitor is about 3.8 V, which has obviously been decreased compared to the traditional PWM strategy shown in Figure 10. The simulation waveforms with improved PWM scheme in a switching period is shown in Figure 13. It can be seen that there are six unequal shoot-through states in a switching period. Therefore, Z-source capacitor voltage has symmetrical maximum amplitude and minimum amplitude in one state. Z-source capacitor voltage ripple is improved.
Figure 10. Simulation waveforms in the traditional PWM scheme.
Figure 10. Simulation waveforms in the traditional PWM scheme.
Energies 09 00056 g010
Figure 11. Amplified waveforms of the input voltage of the inverter bridge and the Z-source capacitor voltage corresponding to Figure 10.
Figure 11. Amplified waveforms of the input voltage of the inverter bridge and the Z-source capacitor voltage corresponding to Figure 10.
Energies 09 00056 g011
Figure 12. Simulation waveforms in the improved PWM scheme.
Figure 12. Simulation waveforms in the improved PWM scheme.
Energies 09 00056 g012
Figure 13. Amplified waveforms of the input voltage of the inverter bridge and the Z-source capacitor voltage corresponding to Figure 12.
Figure 13. Amplified waveforms of the input voltage of the inverter bridge and the Z-source capacitor voltage corresponding to Figure 12.
Energies 09 00056 g013
An experimental platform has been built to compare the improved PWM strategy and traditional PWM strategy. TMS320F28335DSP is used to realize the control strategy. An induction motor is utilized to drag the PMSG to imitate a wind turbine. The energy generated by PMSG pass diode rectifier and Z-source inverter then flow into the grid. Figure 14 shows the experimental prototype. The switching frequency is 10 kHz. The experimental results are collected by the Tektronix oscilloscope.
Figure 14. A picture of the experimental system.
Figure 14. A picture of the experimental system.
Energies 09 00056 g014
The experimental waveforms with traditional PWM scheme in 0.6 s are shown in Figure 15, where the Z-source inductor current, the input voltage of inverter bridge, the Z-source capacitor voltage, and the output three-phase current can be seen. The ripple voltage of the Z-source capacitor is about 6 V, which is consistent with the simulation results. The experimental waveforms with the traditional PWM scheme in two switching periods is shown in Figure 16. It can be seen that twelve equal shoot-through states exist in two switching periods.
Figure 15. Experimental waveforms in the traditional PWM scheme.
Figure 15. Experimental waveforms in the traditional PWM scheme.
Energies 09 00056 g015
Figure 16. Amplified waveforms of the input voltage of the inverter bridge and the Z-source capacitor voltage corresponding to Figure 15.
Figure 16. Amplified waveforms of the input voltage of the inverter bridge and the Z-source capacitor voltage corresponding to Figure 15.
Energies 09 00056 g016
The experimental waveforms with the improved PWM scheme in 0.6 s is shown in Figure 17. It can be seen that the ripple voltage of Z-source capacitor is about 3.8 V, which has obviously been decreased compared to the traditional PWM strategy shown in Figure 15. Figure 18 shows that twelve unequal shoot-through states exist in two switching periods, which agrees with the simulation results.
With the improved PWM scheme, the ripple voltage of the Z-source capacitor is significantly reduced by 37% compared with the traditional strategy. Thus, the cost of the Z-source capacitor can be reduced under the same ripple requirements.
The experimental result-based efficiency comparison of the proposed method and the conventional one is shown in Figure 19. It can be seen from Figure 19 that the converter’s efficiency of the proposed PWM scheme is higher than that of the conventional one in different typical power conversion levels.
Figure 17. Experimental waveforms in the improved PWM scheme.
Figure 17. Experimental waveforms in the improved PWM scheme.
Energies 09 00056 g017
Figure 18. Amplified waveforms of the input voltage of the inverter bridge and the Z-source capacitor voltage corresponding to Figure 17.
Figure 18. Amplified waveforms of the input voltage of the inverter bridge and the Z-source capacitor voltage corresponding to Figure 17.
Energies 09 00056 g018
Figure 19. ZSI efficiency curves when using the proposed PWM scheme and the conventional PWM scheme.
Figure 19. ZSI efficiency curves when using the proposed PWM scheme and the conventional PWM scheme.
Energies 09 00056 g019

4. Conclusions

In this paper, an improved PWM strategy is proposed for a Z-source grid-connected wind generation system to reduce the voltage ripple of the Z-source capacitor. The Z-source capacitor ripple voltage is analyzed in detail under the traditional and improved PWM scheme. In comparison with the traditional PWM scheme, the shoot-through time is rearranged according to the active state and zero state under the same total shoot-through time in the proposed scheme. Simulation and experimental results demonstrate that with the improved PWM scheme, the ripple voltage of the Z-source capacitor is significantly reduced by 37% compared with the traditional strategy. As a result, smaller capacitors can be utilized under the same ripple requirements in a Z-source grid-connected wind generation system.

Acknowledgments

This work is supported from the National Natural Science foundation of China (Project No. 51377050).

Author Contributions

Shoudao Huang and Yang Zhang conceived and designed the proposed control strategy and model. Yang Zhang performed experimental analysis, and modelling and simulation. Zhikang Shuai significantly contributed to the analysis of the simulation and the writing of the paper.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Jamil, M.; Gupta, R. A Review of Power Converter Topology used with PMSG Based Wind Power Generation. In Proceedings of the IEEE 5th Power India Conference, Murthal, India, 14–22 December 2012; pp. 1–6.
  2. Chen, J.; Hung, W. Blade Fault Diagnosis in Small Wind Power Systems Using MPPT with Optimized Control Parameters. Energies 2015, 8, 9191–9210. [Google Scholar] [CrossRef]
  3. Jeong, H.G.; Seung, R.H.; Lee, K.B. An Improved Maximum Power Point Tracking Method for Wind Power Systems. Energies 2012, 5, 1339–1354. [Google Scholar] [CrossRef]
  4. Chen, J.; Yau, H.; Hung, W. Design and Study on Sliding Mode Extremum Seeking Control of the Chaos Embedded Particle Swarm Optimization for Maximum Power Point Tracking in Wind Power Systems. Energies 2014, 7, 1706–1720. [Google Scholar] [CrossRef]
  5. Song, S.; Kang, S.; Hahm, N. Implementation and Control of Grid Connected AC-DC-AC Power Converter for Variable Speed Wind Energy Conversion System. In Proceedings of the 18th IEEE Applied Power Electronics Conference and Exposition, Miami, FL, USA, 9–13 February 2003; pp. 154–158.
  6. Amei, K.; Takayasu, Y.; Ohji, T.; Sakui, M. A Maximum Power Control of Wind Generator System Using a Permanent Magnet Synchronous Generator and a Boost Chopper Circuit. In Proceedings of the Power Conversion Conference, Osaka, Japan, 2–5 April 2002; pp. 1447–1452.
  7. Peng, F.; Shen, M.; Qian, Z. Maximum Boost Control of the Z-Source Inverter. IEEE Trans. Power Electron. 2005, 20, 833–838. [Google Scholar] [CrossRef]
  8. Peng, F.; Joseph, A.; Wang, J. Z-Source Inverter for Motor Drives. IEEE Trans. Power Electron. 2005, 20, 857–863. [Google Scholar] [CrossRef]
  9. Liu, J.; Hu, J.; Xu, L. Dynamic Modeling and Analysis of Z Source Converter—Derivation of AC Small Signal Model and Design-Oriented Analysis. IEEE Trans. Power Electron. 2007, 22, 1786–1796. [Google Scholar] [CrossRef]
  10. Tran, Q.; Chun, T.; Ahn, J.; Lee, H. Algorithms for Controlling Both the DC Boost and AC Output Voltage of Z-Source Inverter. IEEE Trans. Ind. Electron. 2007, 54, 2745–2750. [Google Scholar] [CrossRef]
  11. Dehghan, S.M.; Mohamadian, M.; Varjani, A.Y. A New Variable-Speed Wind Energy Conversion System Using Permanent-Magnet Synchronous Generator and Z-Source Inverter. IEEE Trans. Energy Convers. 2009, 24, 714–724. [Google Scholar] [CrossRef]
  12. Zhang, S.; Tseng, K.; Vilathgamuwa, D.M. Design of a Robust Grid Interface System for PMSG-Based Wind Turbine Generators. IEEE Trans. Ind. Electron. 2011, 58, 316–328. [Google Scholar] [CrossRef]
  13. Yu, Y.; Zhang, Q.; Liang, B.; Liu, X.; Cui, S. Analysis of a Single-Phase Z-Source Inverter for Battery Discharging in Vehicle to Grid Applications. Energies 2011, 4, 2224–2235. [Google Scholar] [CrossRef]
  14. Ahmed, T.; Soon, T.K.; Mekhilef, S. A Single Phase Doubly Grounded Semi-Z-Source Inverter for Photovoltaic (PV) Systems with Maximum Power Point Tracking (MPPT). Energies 2014, 7, 3618–3641. [Google Scholar] [CrossRef]
  15. Anderson, J.; Peng, F.Z. Four Quasi-Z-Source Inverters. In Proceedings of the 39th IEEE Annual Power Electronics Specialists Conference, Rhodes, Greece, 15–19 June 2008; pp. 2743–2749.
  16. Tang, Y.; Xie, S.; Zhang, C. Improved Z-Source Inverter with Reduced Z-Source Capacitor Voltage Stress and Soft-Start Capability. IEEE Trans. Power Electron. 2009, 24, 409–415. [Google Scholar] [CrossRef]
  17. Cai, C.; Qu, Y.; Sheng, K. Novel Modulation of Enhanced Z-source Inverter to Minimize Switching Frequency and Volume of the Z-source Passive Components. Electr. Inf. Eng. Mech. 2011, 138, 295–303. [Google Scholar]
  18. Siwako, Y.P.; Peng, F.Z.; Blaabjerg, F.; Loh, P.C.; Town, G.E. Impedance-Source Networks for Electric Power Conversion Part I: A Topological Review. IEEE Trans. Power Electron. 2015, 30, 699–716. [Google Scholar] [CrossRef]
  19. Siwako, Y.P.; Peng, F.Z.; Blaabjerg, F.; Loh, P.C.; Town, G.E.; Yang, S.T. Impedance-Source Networks for Electric Power Conversion Part II: Review of Control and Modulation Techniques. IEEE Trans. Power Electron. 2015, 30, 1887–1906. [Google Scholar] [CrossRef]
  20. Peng, F.Z. Z-Source Inverter. IEEE Trans. Ind. Appl. 2003, 39, 504–510. [Google Scholar] [CrossRef]
  21. Kim, Y.S.; Yop, Y., II; Moon, S., II. Tuning of the PI Controller Parameters of a PMSG Wind Turbine to Improve Control Performance under Various Wind Speeds. Energies 2015, 8, 1406–1425. [Google Scholar] [CrossRef]

Share and Cite

MDPI and ACS Style

Huang, S.; Zhang, Y.; Shuai, Z. Capacitor Voltage Ripple Suppression for Z-Source Wind Energy Conversion System. Energies 2016, 9, 56. https://doi.org/10.3390/en9010056

AMA Style

Huang S, Zhang Y, Shuai Z. Capacitor Voltage Ripple Suppression for Z-Source Wind Energy Conversion System. Energies. 2016; 9(1):56. https://doi.org/10.3390/en9010056

Chicago/Turabian Style

Huang, Shoudao, Yang Zhang, and Zhikang Shuai. 2016. "Capacitor Voltage Ripple Suppression for Z-Source Wind Energy Conversion System" Energies 9, no. 1: 56. https://doi.org/10.3390/en9010056

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop