Enhancing Wire-Rope Damage Signals Based on a Radial Magnetic Concentrator Bridge Circuit

1
School of Mechanical Electronic and Information Engineering, China University of Mining & Technology, Beijing 100083, China
2
Key Laboratory of Intelligent Mining and Robotics, Ministry of Emergency Management, Beijing 100083, China
*
Author to whom correspondence should be addressed.
Sensors 2022, 22(10), 3654; https://doi.org/10.3390/s22103654
Submission received: 25 April 2022 / Revised: 8 May 2022 / Accepted: 9 May 2022 / Published: 11 May 2022
(This article belongs to the Section Electronic Sensors)

Abstract

:
Hall-effect sensors are used for the non-destructive testing of wire ropes owing to their low power consumption and high operation frequency. The high-speed operation of wire ropes causes vibration inclination at different frequencies, which makes it difficult to detect the ropes. Considering that the radial signal in the magnetic flux leakage (MFL) detection method can respond to damages to the maximum extent possible, this study proposes a radial magnetic concentrator suitable for the non-destructive testing of wire ropes based on theoretical analysis and transient magnetic field simulations. The concentrator improves the radial magnetic circuit, polymerizes the leakage of the magnetic field in the detection device, and the leakage of the magnetic field of the defect converges at the sensor position of the circumferential array to improve the signal-to-noise ratio of the Hall-effect sensor. In addition, the MFL field is homogenized through the structure of the magnetic concentrator when the wire rope is tilted, which weakens the influence of the vibration tilt of the wire rope on the test results. Finally, the experiments show that the amplitude of the wire-rope damage signal is effectively improved by using the proposed radial magnetic concentration technology, hence being convenient for defect analyses.

1. Introduction

Wire ropes are usually used in the continuous vibration environment, but may be broken, or exposed to wear, rust, and other damages [1]. Wire ropes are usually twisted from high-quality carbon structural steel wires, which are typical ferromagnetic materials. The magnetic flux leakage (MFL) detection technique is extensively used to diagnose the surface and internal defects of ferromagnetic parts such as wire ropes, oil and gas pipelines, and tracks, because of its advantages associated with a lack of pollution, lack of coupling agents, and its high reliability [2,3,4]. The vibration load on the part not only affects the structural stability but also interferes with leakage detection [5,6].
To solve the interference caused by the wire rope in the process of vibration, many scholars at home and abroad have made various improvements to the leakage detection method, excitation detection device, and leakage signal processing to reduce the impact of vibration on leakage detection. For example, Kaczmarczyk in Germany designed an electromagnetic sensor based on Hall-effect sensors by arranging 30 sensors in the circumferential direction of the wire rope to establish a three-dimensional signal associated with the rope’s damage, thus observing the distribution of defective damage in the axial and circumferential directions of the wire rope [7]. Wang et al. studied the effects of the lift-off value on the Hall-effect sensor and designed a magnetic circuit structure suitable for the Hall-effect sensor according to the variation law of the lift-off value that can ensure that the Hall-effect sensor maintains high sensitivity in detecting the wire rope [8]. Zhang et al. designed a magnetic concentrator sensor, which allows full acquisition of the MFL with a magnetic centralizer, and the number of Hall-effect sensors used was reduced; this simplified the subsequent signal processing [9]. Yu et al. used a combination of finite elements and genetic algorithms to optimize the excitation source and leakage distribution that improved the reliability of wire-rope detection [10]. Scholars have also used various signal processing methods to reduce vibration noise. For example, Liu et al. used a combined signal processing method based on a trap filter and wavelet denoising [11]. Zhao et al. used a two-dimensional Fourier transform approach to reduce vibration noise [12].
However, increasing the number of Hall-effect sensors through the ring array makes the signal processing more burdensome, and the subsequent eigenvalue extraction becomes cumbersome. The magnetoresistive sensors are used to improve the sensitivity of the sensor while lift-off values need to be operated within a very small variation range, which is difficult to apply in online wire-rope detection [13]. The rapid development of magnetic concentrating detection technology in the field of inspection [14,15] provides a new way of development to solve the wire-rope vibration. The principle of magnetic concentrating detection is achieved by adding ferromagnetic components to the air gap, thus improving the air-gap magnetic field in order to achieve wire-rope detection by a small number of magnetic sensitive elements [16]. Wang et al. [15] analyzed the performance of the magnetic concentrator to collect MFL by finite element simulation and proposed a structure suitable for the axial collection of leakage flux.
In the above magnetic concentration technique, the concentrator mainly acts as a homogenizer for the leakage magnetization parallel to the main magnetic flux. However, Hall-effect sensors for radial detection have smaller lift-off values, which is more beneficial for wire rope non-destructive testing. The radial magnetic concentrator provides the Hall-effect sensor with the ability to maintain a small lift-off value while acting as a convergent magnetic field.
In this study, a sensor consisting of a radial magnetic concentrator and a Hall-effect sensor array is designed to detect wire-rope damage. The structural parameters of the magnetic concentrator were optimized by the finite element method, and the relationship between the magnetic bridge and air gap of the radial magnetic concentrator and the performance of the magnetic concentrator collecting MFL were investigated. In addition, considering the effect of wire-rope tilting on radial leakage magnetic acquisition, we also studied the variation of leakage magnetic field when the wire rope was tilted following the installation of a radial magnetic concentrator. Finally, the sensor was applied to the wire breakage detection experiment, and the waveform was plotted in MATLAB; in this way, the MFL signal could be identified clearly.
The remainder of this article is organized as follows. In Section 2, the principle of wire-rope leakage scanning is introduced and the two-dimensional magnetic dipole model when the wire rope is tilted is analyzed. In Section 3, the mathematical and simulation models of the radial magnetic concentrator are described in detail. In Section 4, the design of sensors and experimental circuits in the study is presented. Experiments, steps, and the analysis of results are given in Section 5. Section 6 concludes the article.

2. Magnetic Field Modeling and Analysis

The principle of radial MFL detection is shown in Figure 1. The wire rope is magnetized to saturation by the permanent magnet in which a soft magnetic material is used as the armature in its peripheral circuit. The connect iron acts as fixed support for the permanent magnet and the conductive magnetic field and acts as a closed magnetic circuit between the external magnetic bridge and the wire rope. When the damaged wire rope passes through the flaw detector, the cross-sectional area of the wire rope changes, the saturation state of the wire rope is broken, and the internal magnetic field of the wire rope overflows and causes leakage. The radially mounted Hall-effect sensor scans the leakage distribution near the wire rope and determines the existence and extent of damage according to the amount of leakage [17].
According to the different scanning directions, the installation direction of the Hall-effect sensor is divided into circumferential, radial, and axial, as shown in Figure 2. Among them, the radial installation has a smaller lift-off value compared with the axial or circumferential Hall-effect sensor [18].
The practical engineering application shows that even if the defects of the same geometric shape are caused by the inclination of the wire rope, the change of the magnetization direction will also cause a completely different leakage magnetic field distribution. Figure 3a shows the wire rope and magnetic imaging scanner with the same frequency tilt, wherein the impact on the radial MFL detection degree is low, where ∆H1 is the angle of synchronous tilt between the magnetic imaging scanner and the target steel wire rope. Figure 3b shows the axis of the wire rope and magnetic imaging scanner offset, permanent magnets on the wire rope, and damage magnetization changes; in turn, ∆θ1 and ∆H2, respectively, indicate the horizontal line tilt angle of the wire rope in the flaw detector, and the offset radial distance of the wire rope in the magnetic imaging scanner. In this study, we mainly discuss the second case and its impact on MFL detection.
Figure 4 illustrates the dipole representation of the wire-rope tilt, the width of the rectangular groove is 2b and the depth is h. With the defect center as the origin and the magnetization direction as the X-axis, the Cartesian coordinate system X–Y can be established [19,20,21,22]. At this time, the magnetic field intensity dH1, and dH2 generated by the microelement on the two groove walls at the field point P (x, y) can be expressed as:
{ d H 1 = σ m s d ξ 2 π μ 0 r 1 2 r 1 d H 2 = σ m s d ξ 2 π μ 0 r 2 2 r 2
In the formula, μ0 is the vacuum permeability, r1 and r2 are the distances between the field point P and the positive and negative magnetic charge lines.
If the distance from the microlinear element to the material surface is noted as ξ, the distance can then be expressed as:
r 1 2 = ( x b ) 2 + ( y ξ ) 2 , r 2 2 = ( x + b ) 2 + ( y ξ ) 2
In the X–Y coordinate system, the magnetic field intensity generated by the two slot-wall microwire is expressed as:
{ d H 1 x = σ m s ( x + b ) d ξ 2 π μ 0 [ ( x + b ) 2 + ( y ξ ) 2 ] d H 2 x = σ m s ( x b ) d ξ 2 π μ 0 [ ( x b ) 2 + ( y ξ ) 2 ]
{ d H 1 y = σ m s ( y ξ ) d ξ 2 π μ 0 [ ( x + b ) 2 + ( y ξ ) 2 ] d H 2 y = σ m s ( y ξ ) d ξ 2 π μ 0 [ ( x b ) 2 + ( y ξ ) 2 ]
where dH1x and dH2x are the X components of the magnetic field intensities generated by the two slot-wall microstrip elements at point, and dH1y, dH2y are the Y components of the magnetic field intensities produced by two slot-wall elements at point P. Integrating the above equation along with the depth of the slot wall h, the magnitude of the X–Y axis components Hx and Hy of the leakage field formed by the two slot walls at the Hall-effect sensor calibration detection point P (x, y) can be obtained as follows:
H x = h 0 d H 1 X + h 0 d H 2 x = σ m s 2 π μ 0 ( tan 1 h ( x + b ) ( x + b ) 2 + y ( y + h ) tan 1 h ( x b ) ( x b ) 2 + y ( y + h ) ) H y = h 0 d H 1 y + h 0 d H 2 y = σ m s 2 π μ 0 ln [ ( x + b ) 2 + ( y + h ) 2 ] [ ( x b ) 2 + y 2 ] [ ( x b ) 2 + ( y + h ) 2 ] [ ( x + b ) 2 + y 2 ]
According to the principle of the magnetic dipole model, the value of σms can be calculated as follows:
σ ms = ( h / b + 1 h / ( b μ ) + 1 ) H 0
In the formula, μ is the relative permeability of the tested material, and b is the external magnetic field intensity.
The magnetic field intensities dH1 and dH2 produced at the point of P (x, y) on the wall of the two grooves are calibrated when the wire rope is running horizontally. When the wire rope vibrates, the external magnetic field B0 shifts, and the affective component of the groove wall decreases; thus, the linear infinitesimal value formed on the groove wall decreases [23]. B1 is the applied magnetic field acting on the surface of the wire rope after the deflection of B0. When the Hall-effect sensor measures the same leakage magnetic value as the calibration point P (x, y), the Hall-effect sensor needs to measure the leakage magnetic value of the moving point Pn1 (xn1, yn1), and the Hall-effect sensor is usually designed to operate at a fixed position for the actual detection.
Therefore, to improve the magnetization effect and the leakage magnetic field of the flaw detector, it is important to build a magnetic bridge between the wire-rope damage and the Hall-effect sensor.

3. Mathematical Model and Simulation Model

According to the characteristics of the radial acquisition mode, the radial magnetic gathering sensor is designed to comprise two parts: a Hall-effect sensor array, and a magnetic concentrator bridge. The magnetic concentrator bridge is divided into short- and long-neck magnetic concentrator bridges. The Hall-effect sensor array is located between the short- and the long-neck magnetic bridges. The MFL signal is aggregated into the Hall-effect sensor through the short-neck magnetic concentrator bridge and returns to the wire rope through the long-neck magnetic concentrator bridge to form a closed magnetic circuit. A three-dimensional model of the radial magnetic concentrator is shown in Figure 5.
In this study, the radial magnetic concentrator sensor is designed according to the radial MFL detection equipment, and the mathematical model of the radial magnetic concentrator is established according to the established radial magnetic concentrator bridge, as shown in Figure 6.
Ignoring the edge effect of the magnetic resistance of the magnetic structure, the calculation method of the air-gap permeability between the magnetic paths of the magnetic structure is derived. The air-gap permeability G1 between the side of the sixteen magnetic concentrators is:
G 1 = 8 μ 0 π ( N / 2 ) 2 H
In the formula listed above, N is the diameter of the header, ∆H is the air-gap length between the header and the long arm, and μ0 is the permeability of air.
According to the loop direction of the radial MFL, the radial MFL loop is simplified, and the air-gap permeance G2 between the upper side of the two concentrators in the radial loop is:
G 2 = μ 0 [ 2 π R D 8 π ( N 2 ) 2 ] L 1 + L 2 + L 3 + M + H
where L1, L2, and L3 are the lengths of the first, second, and third sections of the long-arm shank, respectively, M is the platform height, D is the bearing length, R is the inner diameter of the bush, and T is the bearing width.
If the ratio of the magnetic flux detected by the Hall-effect sensor to the total magnetic flux flowing through the magnetic ring is the magnetic concentration efficiency, then
η = G 1 G 1 + G 2 = 8 μ 0 π ( N / 2 ) 2 H 8 μ 0 π ( N / 2 ) 2 H + μ 0 [ 2 π R D 8 π ( N 2 ) 2 ] L 1 + L 2 + L 3 + M + H = ( 1 + H ( R D N 2 1 ) L 1 + L 2 + L 3 + M + H ) 1
As shown in Equation (9), to increase the value of η, we can increase N, L1, L2, L3, and M, or reduce ∆H.
To verify the influences of the variations of L1, L2, L3, and M on the effect of magnetic gathering, the magnetic field model of the wire-rope excitation is analyzed by numerical finite element simulations, and the detection effect which is subject to the condition of existing magnetic gathering devices is compared and analyzed. A wire rope with a length of 270 mm and a diameter of 8 mm is set as the origin of the coordinate axis, and the axial length of 8 mm and the depth of damage of 4 mm are set above the origin. The lifting-off value y is set as 6 mm. The selected magnet was an N48 NdFeB permanent magnet, the coercive force was set to 920,000 A/m, and the permanent magnetization was 1.36 T. The observation line with the length of the observation line Ln with a length of 40 mm was set at a distance of 10 mm from the origin in the Y direction and from −24 mm to 16 mm in the X-direction.
Figure 7, Figure 8, Figure 9 and Figure 10 clearly show the effect on the leakage magnetism when the parameters of L1, L2, L3, and M are changed. To further analyze the influence law of each parameter, the peak values of L1, L2, L3, and M are extracted, as shown in Figure 11. As L1 and L3 increase, the magnetic induction intensity value at the defect increases, and when L1 and L3 increase to 5 mm the magnetic field inside the magnetic concentrator gradually saturates, which makes the magnetic flux detected by the Hall-effect sensor reach saturation quickly, and the growth rate of η decreases. Therefore, L1 and L3 are chosen to be 5 mm to make the magnetic concentrator reach the best efficiency. L2 has a slower effect on η, and L2 determines the axial length of the magnetic concentrator; thus, the minimum size of the flexible printed circuit (FPC) board installation should be maintained when L2 is chosen. As M increases, the magnetic induction intensity value at the defect increases, however, the height of M will affect the detection performance of the Hall-effect sensor. Excessively large M values will increase the lift-off value of the Hall-effect sensor. Thus, setting M to 4 mm is optimal, and the size of N needs to be matched with the width of the selected Hall-effect sensor sensing surface. Therefore, N should be the maximum value of the surface width of the Hall-effect sensor.
Based on the above analysis, ∆H is simulated in the optimal L1, L2, L3, and M environments, and the effect of ∆H on the magnetic concentration is determined by measuring the flux leakage at the center of the reference line. According to Figure 12, with the increase in ∆H, the defect magnetic induction intensity decreases. When ∆H continues to increase, the lift-off value between the long- and the short-neck magnetic concentrators is too large, and the magnetic concentrator cannot concentrate the air-gap magnetic field. Therefore, to achieve the best magnetic field aggregation effect, the lift-off value of the convex end-face between the long- and the short-neck magnetic concentrators should be kept at a small distance.
A ∆H of 2 mm is used as the air-gap distance of the convex platform of the magnetic concentrator to verify the magnetic concentrator effect on the inclined wire rope. The swing angle of the wire rope is determined by the inner hole radius of the flaw detector. The inner lining radius of the flaw detector was 22 mm. Therefore, the swing angle θ of the wire-rope axis and the horizontal axis was set to values in the range of 0.5–3° and the angle increment to 0.5°. The MFL induction intensity with the defect axial length of 8 mm and the depth of 4 mm was measured at position Ln.
Figure 13a shows the magnetic induction intensity value of the magnetic concentrator installed in the angular swing range of 0.5–3°. According to the results shown in Figure 13a, with the increase in the swing angle, the peak value of the magnetic induction intensity does not decrease considerably, and the peak value at the damage location remains at approximately 426 mT. Figure 13b shows the magnetic induction intensity value in the case in which there was no magnetic concentrator in the angular swing range of 0.5–3°. According to the results shown in Figure 13b, with the increase in the swing angle, the peak value of magnetic induction intensity decreases gradually, the peak value at the damage is maintained at approximately 236 mT, and the peak slows down at a low rate.

4. Design of Wire-Rope Detector

4.1. Circuit Design of Sensor

The FPC plate was used as the carrier of the sensor in synergy with the magnetic concentrator, and the Hall-effect sensor was uniformly distributed on the FPC plate. The FPC is easy to bend, but the radial lift-off value can be controlled and can be maintained at its minimum. When the FPC plate is bent with the inner cavity of the flaw detector, the Hall-effect sensor array is arranged into a radial circular array, and the Hall-effect sensor array corresponds to the convex position of the magnetic concentrator, as shown in Figure 14.
The damage to the wire rope may occur at any position in its circumferential direction. To ensure the comprehensive detection of wire-rope damage, multiple Hall-effect sensors should be arranged uniformly and densely along the circumference of the same section of the wire rope. The specific number should meet the following condition:
N h = C I N T [ S p S s ]
In the formula listed above, Sp is the perimeter of the ring surface of the Hall-effect sensor, Ss is the circumferential coverage area of the single Hall-effect sensor, and CINT [•] is the round-off integral function. The Hall-effect sensors of the THS119 series were used in the experiment. According to the number of circumferential arrangements of the existing flawed detector, the maximum outer contour radius of the antiwear lining of the flawed detector was 22 mm, and the inner arc radius of the concentrator was 27 mm. When the FPC plate was installed in the radius range of 22–27, the Sp was in the range of 139–170, and the circumferential coverage range of the THS119 series Hall-effect sensors was in the range of 17–20. According to the actual measurements, the Ss value was 20, and the input was equal to 10. The theoretical value of Nh was in the range of 7–8.5. Thus, Nh was assumed to be equal to eight.
As shown in Figure 15, pins 1 and 3 are input, namely, they are the power pins, while pins 2 and 4 are the differential outputs (The red letters 1, 2, 3 and 4 in Figure 15 indicate the pin locations of the Hall-effect sensors.). When the power is supplied to the Hall-effect sensor, a constant current in the range of 5 or 10 mA is achieved when the Hall-effect sensor works in a linear region. According to Nh = 8, the FPC board, which is unfolded in the plane shown in Figure 16, is equipped with eight Hall-effect sensors, each of which was 20 mm apart. These sensors were powered in series by a constant current source that simultaneously supplied two Hall-effect sensors, such as A1 and A2, as shown in Figure 15. In the A1 and A2 sensors, the positive electrode of the constant current source was connected to the first pin of A1, and the negative electrode was connected to the third pin of A2. At the same time, the third pin of A1 was connected to the first pin of A2.

4.2. Mounting of FPC Boards

The FPC plate was installed in the wire-rope detector in a curved way, the working surface of the Hall-effect sensor was parallel to the surface of the wire rope, and the lift-off value was controlled in the minimum range. The wire-rope detector consisted of upper and lower parts with permanent magnets made of neodymium boron as the excitation source. Additionally, the left and right permanent magnets were wrapped around the wire rope once, thus forming a closed magnetic circuit with the wire rope. The FPC plate is wrapped around the liner, which is used to isolate the wire rope and to support the FPC and the magnetic concentrator. The magnetic concentrator was mounted in the gap between the liner and the armature, and the tab of the magnetic concentrator corresponded to the position of the Hall-effect sensor on the FPC board at the end (near the tab shank), as shown in Figure 17. There are two types of samplings: temporal and spatial. In the process of using equally spaced pulse signals to control the damage signal sampling to ensure that no slippage was generated between the roller and the wire rope, the elastic damping member was added to the wire-rope detector.

5. Experiments

5.1. Experimental Setting

To verify the radial magnetic concentration effect of the wire rope, the following experiments are designed:
  • Wire rope and the axis of the flawed detector overlap.
    We selected 7 × 6 × 19 FS wire ropes prefabricated with external damage with a fixed number of broken wire roots, a starting value of the length of the broken wire of 3 mm, and regular production damage with a length gain of 2 mm. The detailed parameters for the damage to the prefabricated wire rope are shown in Figure 18. To reduce the influence of adjacent damage, it is recommended that the axial distance between the prefabricated damage (300 mm) is greater than the length of the flaw detector (270 mm). Figure 19 shows the experiment associated with the installation of the magnetic concentrator in which the implementation of the long- and the short-neck magnetic concentrator is shown. The sensor with the concentrator removed is used to detect damage (conventional detection method). Figure 20 clearly illustrates the detector composition for the conventional detection method. The FPC board was wound in the gap of the three-dimensional printed liner, and the end of the FPC board was welded with an external circuit quick plug to realize the power input and the output of the signal outside the detector.
  • Axis deviation of wire rope and flaw detector.
    The tilt experiment was performed using the magnetic concentrator method and the conventional detection method, where the magnetic concentrator method used the structure in Figure 19 and the conventional detection method was the device in Figure 20. This part of the experiment was conducted on the non-destructive testing platform of the wire rope. By lifting the wheel shaft of the experimental platform, the inclination angle of the wire rope relative to the flaw detector was adjusted. As shown in Figure 21, the red-dotted line shows the horizontal position of the bearing seat, the yellow-dotted line shows the horizontal position of the wheel shaft, the blue-dotted line shows the adjustment height of the wheel shaft, the double-dotted yellow line shows the horizontal position of the wire rope, and the rough yellow solid line shows the inclined angle of the wire rope after adjustment. A closed-loop wire rope wound on the detection platform was selected, and the damage with 19 broken wires and 10 mm broken wires were produced at an interval of 30 mm. Taking the running direction V of the wire rope as the positive direction of the X-axis, the wire rope was set to deflect by an angle θ in the positive direction of the X-axis. On the detection platform, the vertical position of the wheel disc was changed by adjusting the wheel shaft ∆G, so as to realize the change of the wire-rope inclination. In this case, θ was in the range of 0.5–3.0°, and the change angle increment was 0.5°.
According to the damage location, the broken line signal was detected many times. Firstly, the amplifier circuit was used to amplify the differential voltage signal output of the Hall-effect sensor. The data acquisition card was used to collect signals, and the collected signals were saved on the computer. The USB 5633 data acquisition card of Beijing Altay Technology Development Company Ltd. (Beijing, China) was used. The highest acquisition frequency of this data acquisition card can be set to 260 kHz.

5.2. Data Analysis

In the signal processing section, the acquired damage signals were converted first and were then saved in an Excel table in a text format. The data in the table were plotted using MATLAB (version 2020b, MathWorks, Natick, MA, USA). The wire rope level controls experimental data for Figure 22. Experiments measured damage from large to small values, the horizontal coordinate in the graph is the detection time in milliseconds (ms), and the vertical coordinate is the detection voltage amplitude in volts (V).
In the wire-rope tilt experiment shown in Figure 23, the traditional leakage detection method with the wire-rope running tilt angle becomes larger. In the detection of the same damage, the amplitude of the damage signal is gradually reduced. Furthermore, because the wire rope tilted, the detected damage signal was mixed with more odd signals. In the magnetic concentrator detection signal, the amplitude of the damage signal increased, thus indicating that the air-gap magnetic field at the damage is aggregated by the magnetic concentrator.
To further explore the relationship between the number of broken wires and signals, it is necessary to conduct in-depth processing of the obtained signals. The peak value, valley value, and peak and valley areas of the two groups of the experimentally interrupted rope signals were derived, and the derived signals were properly counted. These included the axial overlap magnetic concentration experiment of the wire rope (Table 1) and the inclined magnetic concentration of the wire rope (Table 2).
Given that there are errors in each damage detection, the average percentage increase in the peak, valley, and peak and valley areas of the damage signal at the same experimental conditions should be regarded as the analysis object. Table 3 shows the overall improved performance of the concentrator on the peak-to-peak value and the waveform area at two experimental conditions.
From the horizontal experiment of the wire rope in Table 3, the magnetic concentrator increases the peak value by 46% and the waveform area by 145%. The magnetic concentrator generates a polymerization magnetic field at the damage sites of the wire rope with uniform length changes and improves the MFL collection efficiency of the Hall-effect sensor. In the tilt experiment, the peak value and waveform areas were increased by 130% and 177%, respectively, and the average peak value and waveform area were maintained at 1300 mV and 7200 mV, respectively. The signal-to-noise ratio (SNR) is the main characterization parameter of the quality of the detected signal, which reflects the ratio of the effective work of the signal and the noise in the original signal. Table 3 clearly shows that the SNR increased by 7.29 dB (21.89 dB > 14.60 dB) after the installation of the concentrator in the wire-rope level experiment, and by 7.72 dB (25.12 dB > 17.40 dB) after the installation of the concentrator in the wire-rope tilt experiment. It is clearly shown that when the magnetic concentrator is installed, the Hall-effect sensor can still effectively collect the leakage magnetic field at the damage location when the wire rope is tilted, and the leakage magnetic field at the damage location remains stable so that the problem of wire-rope tilt jitter is solved to a certain extent when using the MFL detection.

6. Conclusions

  • To solve the influence of wire-rope inclination on damage magnetic field leakage, this study proposed a radial magnetic concentration method of the wire rope based on the magnetic circuit law. To construct a radial magnetic concentrator bridge, a magnetic circuit was established inside the flaw detector, and a sensor based on radial magnetic concentration was designed. The research contents of this study mainly include:
  • The analysis of installation methods of Hall-effect sensors in typical MFL detection arrangements, and the comparison of the characteristics of different installation methods. According to the damage detection method and principle of radial installation, the radial detection was selected as the best strategy for the construction of magnetic concentrator bridges;
  • The inclined vibration type of the wire rope in the flawed detector case was clarified, and the two-dimensional magnetic dipole model was established at the damage point to determine the basic variation law of MFL;
  • The establishment of a radial magnetic concentrator bridge, an analysis of the effect of magnetic concentrator size and air-gap distance on the leakage field, and the selection of a suitable structure size to make the efficiency optimal;
  • The horizontal and tilt detection experiments of wire rope based on a radial magnetic concentrator bridge were designed. The horizontal experiment adopted seven types of wire-rope damage assessments and the tilt experiment adopted a single type of damage. The control variable method of different tilt angles was used for evaluation;
  • Compared with the experimental results of the two groups, it was shown that the radial magnetic concentrator can be used to obtain more disrupted line signals. From the horizontal experimental results, the peak value of the radial magnetic concentrator for different lengths of damage increased by 46%, and the waveform area increased by 145%. The magnetic concentrator had an efficient magnetic effect on the axial length change in the horizontal test experiment. According to the tilt test results, the peak value of the radial magnetic concentrator can be increased by 130% and the waveform area can be increased by 177%. In the tilt test, the magnetic concentrator not only polymerized the leakage magnetic field of the damage but also stabilized the leakage magnetic field of the damage.

Author Contributions

Conceptualization, J.T., H.W., and W.W.; methodology, Q.B.; software, P.L.; validation, Z.Z., W.W. and Q.B.; formal analysis, J.T.; investigation, Q.B.; resources, Z.Z.; data curation, J.T.; writing—original draft preparation, W.W.; writing—review and editing, J.T. and H.W.; visualization, W.W.; supervision, Q.B.; project administration, P.L.; funding acquisition, J.T. and H.W. All authors have read and agreed to the published version of the manuscript.

Funding

This work was supported by the Fundamental Research Funds for the Central Universities under Grant 2021YQJD02, 2022JCCXJD02 and 2022YJSJD09. And was also supported by Open Research Fund of Key Laboratory of Nondestructive Testing (Nanchang Hangkong University), Ministry of Education (EW202180222), the National Natural Science Foundation of China under Grant 51774293.

Acknowledgments

The authors would like to thank Project from the China University of Mining and Technology, Beijing, China, and the Fundamental Research Funds for the Central Universities for providing the financial support to conduct this research.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Kim, J.-W.; Park, S. Magnetic Flux Leakage Sensing and Artificial Neural Network Pattern Recognition-Based Automated Damage Detection and Quantification for Wire Rope Non-Destructive Evaluation. Sensors 2018, 18, 109. [Google Scholar] [CrossRef] [Green Version]
  2. Ravan, M.; Amineh, R.K.; Koziel, S.; Nikolova, N.K.; Reilly, J.P. Sizing of 3-D Arbitrary Defects Using Magnetic Flux Leakage Measurements. IEEE Trans. Magn. 2010, 46, 1024–1033. [Google Scholar] [CrossRef]
  3. Park, S.; Kim, J.W.; Lee, C.; Lee, J.J. Magnetic Flux Leakage Sensing-Based Steel Cable NDE Technique. Shock. Vib. 2014, 2014, 929341. [Google Scholar] [CrossRef] [Green Version]
  4. Kim, H.M.; Heo, C.G.; Cho, S.H.; Park, G.S. Determination Scheme for Accurate Defect Depth in Underground Pipeline Inspection by Using Magnetic Flux Leakage Sensors. IEEE Trans. Magn. 2018, 54, 1–5. [Google Scholar] [CrossRef]
  5. Sanchis, R.; Cardona, S.; Martinez, J. Determination of the Vertical Vibration of a Ballasted Railway Track to Be Used in the Experimental Detection of Wheel Flats in Metropolitan Railways. J. Vib. Acoust. Trans. ASME 2019, 141, 16. [Google Scholar] [CrossRef]
  6. Pan, S.M.; Zhang, D.L.; Zhang, E.C. Analysis of the Eccentric Problem of Wire Rope Magnetic Flux Leakage Testing. In Proceedings of the IEEE 3rd Information Technology, Networking, Electronic and Automation Control Conference (ITNEC), Chengdu, China, 15–17 March 2019; pp. 1597–1601. [Google Scholar]
  7. Kaczmarczyk, S.; Ostachowicz, W. Transient vibration phenomena in deep mine hoisting cables. Part 1: Mathematical model. J. Sound Vibr. 2003, 262, 219–244. [Google Scholar] [CrossRef]
  8. Hua, G.; Wang, H.Y.; Chen, F.J.; Lu, Y.H.; Xu, Z.; Tian, J.; Zhou, B.B. Improving SNR of MFL Signal in Flaw Detection of Coal Mine Wire Ropes. In Proceedings of the 2nd International Congress on Image and Signal Processing, Tianjin, China, 17–19 October 2009; pp. 4674–4679. [Google Scholar]
  9. Zhang, Y.Q.; Jing, L.Y.; Xu, W.X.; Zhan, W.X.; Tan, J.W. A Sensor for Broken Wire Detection of Steel Wire Ropes Based on the Magnetic Concentrating Principle. Sensors 2019, 19, 14. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  10. Chang, Y.; Jiao, J.P.; Li, G.H.; Liu, X.C.; He, C.F.; Wu, B. Effects of excitation system on the performance of magnetic-flux-leakage-type non-destructive testing. Sens. Actuators A Phys. 2017, 268, 201–212. [Google Scholar] [CrossRef]
  11. Liu, S.W.; Sun, Y.H.; Ma, W.J.; Xie, F.; Jiang, X.Y.; He, L.S.; Kang, Y.H. A New Signal Processing Method Based on Notch Filtering and Wavelet Denoising in Wire Rope Inspection. J. Nondestruct. Eval. 2019, 38, 14. [Google Scholar] [CrossRef]
  12. Zhao, M.; Zhang, D.; Zhou, Z. The research on quantitative inspection technology to wire rope defect based on Hall sensor array. Nondestruct. Test. 2012, 34, 57–60. [Google Scholar]
  13. Wu, B.; Wang, Y.J.; Liu, X.C.; He, C.F. A novel TMR-based MFL sensor for steel wire rope inspection using the orthogonal test method. Smart Mater. Struct. 2015, 24, 12. [Google Scholar] [CrossRef]
  14. Gu, Y.; Zhang, D.L.; Zhang, X.F.; Zhou, Z.C. A Modified Full Bridge Converter with Magnetic Integration Technique. In Proceedings of the 46th Annual Conference of the IEEE-Industrial-Electronics-Society (IECON), Singapore, 19–21 October 2020; pp. 1171–1174. [Google Scholar]
  15. Wang, H.Y.; Tian, J.; Li, X.W.; Lv, X. Inspection of Mine Wire Rope Using Magnetic Aggregation Bridge Based on Magnetic Resistance Sensor Array. IEEE Trans. Instrum. Meas. 2020, 69, 7437–7448. [Google Scholar] [CrossRef]
  16. Yan, X.L.; Zhang, D.L.; Wang, H.P. Increasing Detection Resolution of Wire Rope Metallic Cross-Sectional Area Damage Based on Magnetic Aggregation Structure. IEEE Trans. Instrum. Meas. 2020, 69, 4487–4495. [Google Scholar] [CrossRef]
  17. Zhang, D.L.; Zhang, E.C.; Pan, S.M.; Yan, X.L.; Gao, W. Fast Quantitative Method to Detect the Cross-Sectional Loss of Wire Rope Defects. IEEE Trans. Instrum. Meas. 2021, 70, 11. [Google Scholar] [CrossRef]
  18. Tian, J.; Zhao, C.Y.; Wang, W.; Sun, G.G. Detection Technology of Mine Wire Rope Based on Radial Magnetic Vector with Flexible Printed Circuit. IEEE Trans. Instrum. Meas. 2021, 70, 10. [Google Scholar] [CrossRef]
  19. Wu, J.B.; Sun, Y.H.; Kang, Y.H.; Yang, Y. Theoretical Analyses of MFL Signal Affected by Discontinuity Orientation and Sensor-Scanning Direction. IEEE Trans. Magn. 2015, 51, 7. [Google Scholar] [CrossRef]
  20. Zhao, Y.; Baharuddin, M.H.; Smartt, C.; Zhao, X.; Yan, L.P.; Liu, C.J.; Thomas, D.W.P. Measurement of Near-Field Electromagnetic Emissions and Characterization Based on Equivalent Dipole Model in Time-Domain. IEEE Trans. Electromagn. Compat. 2020, 62, 1237–1246. [Google Scholar] [CrossRef]
  21. Dutta, S.M.; Ghorbel, F.H.; Stanley, R.K. Dipole Modeling of Magnetic Flux Leakage. IEEE Trans. Magn. 2009, 45, 1959–1965. [Google Scholar] [CrossRef]
  22. Hosseingholizadeh, S.; Filleter, T.; Sinclair, A.N. Evaluation of a Magnetic Dipole Model in a DC Magnetic Flux Leakage System. IEEE Trans. Magn. 2019, 55, 7. [Google Scholar] [CrossRef]
  23. Wu, D.H.; Liu, Z.T.; Wang, X.H.; Su, L.X. Mechanism analysis of influence of surface-breaking orientation on magnetic leakage field distribution. Acta Phys. Sin. 2017, 66, 11. [Google Scholar] [CrossRef]
Figure 1. Principle diagram of MFL detection.
Figure 1. Principle diagram of MFL detection.
Sensors 22 03654 g001
Figure 2. Schematic diagram of circumferential, radial, and axial positions of Hall-effect sensor: (a) Circumferential installation; (b) Radial installation; (c) Axial installation.
Figure 2. Schematic diagram of circumferential, radial, and axial positions of Hall-effect sensor: (a) Circumferential installation; (b) Radial installation; (c) Axial installation.
Sensors 22 03654 g002
Figure 3. Tilt-type diagram of wire rope: (a) Tilting at the same frequency; (b) Axis offset tilt.
Figure 3. Tilt-type diagram of wire rope: (a) Tilting at the same frequency; (b) Axis offset tilt.
Sensors 22 03654 g003
Figure 4. Mathematical model of tilt magnetization.
Figure 4. Mathematical model of tilt magnetization.
Sensors 22 03654 g004
Figure 5. Three-dimensional model of radial magnetic concentrator.
Figure 5. Three-dimensional model of radial magnetic concentrator.
Sensors 22 03654 g005
Figure 6. Mathematical model of radial magnetic concentrator.
Figure 6. Mathematical model of radial magnetic concentrator.
Sensors 22 03654 g006
Figure 7. Effect of L1 on the magnetic concentrator.
Figure 7. Effect of L1 on the magnetic concentrator.
Sensors 22 03654 g007
Figure 8. Effect of L2 on the magnetic concentrator.
Figure 8. Effect of L2 on the magnetic concentrator.
Sensors 22 03654 g008
Figure 9. Effect of L3 on the magnetic concentrator.
Figure 9. Effect of L3 on the magnetic concentrator.
Sensors 22 03654 g009
Figure 10. Effect of M on the magnetic concentrator.
Figure 10. Effect of M on the magnetic concentrator.
Sensors 22 03654 g010
Figure 11. Leakage density at different parameters.
Figure 11. Leakage density at different parameters.
Sensors 22 03654 g011
Figure 12. Effect of ∆H on the magnetic concentrator.
Figure 12. Effect of ∆H on the magnetic concentrator.
Sensors 22 03654 g012
Figure 13. Comparison of magnetic induction intensity after installing the magnetic concentrator. (a) The magnetic induction intensity when the wire rope is inclined. (b) Inclined magnetic induction intensity of wire rope without concentrator.
Figure 13. Comparison of magnetic induction intensity after installing the magnetic concentrator. (a) The magnetic induction intensity when the wire rope is inclined. (b) Inclined magnetic induction intensity of wire rope without concentrator.
Sensors 22 03654 g013
Figure 14. Installation diagram of Hall-effect sensor and radial magnetic concentrator.
Figure 14. Installation diagram of Hall-effect sensor and radial magnetic concentrator.
Sensors 22 03654 g014
Figure 15. Circuit diagram of integrated Hall-effect sensor.
Figure 15. Circuit diagram of integrated Hall-effect sensor.
Sensors 22 03654 g015
Figure 16. FPC circuit diagram.
Figure 16. FPC circuit diagram.
Sensors 22 03654 g016
Figure 17. Installation of magnetic concentrator and FPC board.
Figure 17. Installation of magnetic concentrator and FPC board.
Sensors 22 03654 g017
Figure 18. Axial variation damage of steel wire rope.
Figure 18. Axial variation damage of steel wire rope.
Sensors 22 03654 g018
Figure 19. Radial magnetic concentration experiment.
Figure 19. Radial magnetic concentration experiment.
Sensors 22 03654 g019
Figure 20. Non-aggregation magnetic experiment.
Figure 20. Non-aggregation magnetic experiment.
Sensors 22 03654 g020
Figure 21. Tilting experiment of steel wire rope.
Figure 21. Tilting experiment of steel wire rope.
Sensors 22 03654 g021
Figure 22. Magnetic contrast experiments with different damage lengths.
Figure 22. Magnetic contrast experiments with different damage lengths.
Sensors 22 03654 g022
Figure 23. Comparative experiments of magnetic concentration at different tilt angles.
Figure 23. Comparative experiments of magnetic concentration at different tilt angles.
Sensors 22 03654 g023
Table 1. Signal characteristic statistics.
Table 1. Signal characteristic statistics.
Broken Distance15 mm13 mm11 mm9 mm7 mm5 mm3 mm
Orthodox MethodPeak (mV)335273246263177140168
Valley (mV)−327−304−366−185−224−159−55
Peak-to-peak (mV)662577612448401299223
Peak-area (mV * ms)8690138913074095185320591679
Valley-area (mV * ms)−9569−5404−4167−2707−2611−1810−914
Waveform (mV * ms)18,259679354746802446438692593
Magnetic ConcentratorPeak (mV)532450446318178193163
Valley (mV)−609−612−408−304−345−213−109
Peak-to-peak (mV)11411062854622523406272
Peak-area (mV * ms)15,77214,66813,731316642910292762
Valley-area (mV * ms)−25,916−27,009−6820−5373−3357−1875−2795
Waveform (mV * ms)41,68841,67720,5518539378629045557
Table 2. Signal characteristic statistics.
Table 2. Signal characteristic statistics.
Bevel Angle 0.5°1.0°1.5°2.0°2.5°3.0°
Orthodox MethodPeak (mV)358205332232248192
Valley (mV)−317−431−264−316−216−276
Peak-to-peak (mV)675636596548464468
Peak-area (mV * ms)1442141520681010930990
Valley-area (mV * ms)−1511−1500−1274−1397−1590−996
Waveform (mV * ms)295329153342240725201986
Magnetic ConcentratorPeak (mV)607648614658577633
Valley (mV)−707−644−695−629−700−567
Peak-to-peak (mV)131412921309128712771200
Peak-area (mV * ms)302540753055577732274374
Valley-area (mV * ms)−4186−2548−4338−2874−3140−2728
Waveform (mV * ms)721166237393865163677102
Table 3. Signal characteristic statistics.
Table 3. Signal characteristic statistics.
Predictable PatternAverage ValueProportionSNR of Conventional Method/dBSNR of Magnetic Concentration Method/dB
Level detection
of wire rope
Peak-to-peak (mV)46.14%14.6021.89
Waveform (mV * ms)145.28%
Tilt detection
of wire rope
Peak-to-peak (mV)130.65%17.4025.12
Waveform (mV * ms)177.05%
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Tian, J.; Wang, W.; Wang, H.; Bai, Q.; Zhou, Z.; Li, P. Enhancing Wire-Rope Damage Signals Based on a Radial Magnetic Concentrator Bridge Circuit. Sensors 2022, 22, 3654. https://doi.org/10.3390/s22103654

AMA Style

Tian J, Wang W, Wang H, Bai Q, Zhou Z, Li P. Enhancing Wire-Rope Damage Signals Based on a Radial Magnetic Concentrator Bridge Circuit. Sensors. 2022; 22(10):3654. https://doi.org/10.3390/s22103654

Chicago/Turabian Style

Tian, Jie, Wei Wang, Hongyao Wang, Qiang Bai, Zeyang Zhou, and Pengbo Li. 2022. "Enhancing Wire-Rope Damage Signals Based on a Radial Magnetic Concentrator Bridge Circuit" Sensors 22, no. 10: 3654. https://doi.org/10.3390/s22103654