Abstract
In this paper, we report a sensitivity-controllable refractive index (RI) sensor based on a reflective θ-shaped microfiber resonator cooperated with Vernier effect. The θ-shaped microfiber resonator is a reflective all-fiber device with comb spectrum under weak coupling condition. By cascading it with a fiber Fabry-Perot interferometer, Vernier effect is generated to demodulate surrounding RI with enhanced sensitivity. Theoretical analysis reveals that RI sensitivity of the combined structure with Vernier effect is m times higher than the sensitivity of singular θ-shaped microfiber resonator. Moreover, by adjusting cavity length of the θ-shaped microfiber resonator, magnification factor Mâ=â(mâ+â1) can be tuned which enables the RI sensitivity to be controlled. Experimental result demonstrates that the RI sensitivity can be widely tuned from 311.77ânm/RIU (Reflective index unit) to 2460.07ânm/RIU when the cavity length of the θ-shaped microfiber resonator is adjusted from 9.4âmm to 8.7âmm. The θ-shaped microfiber resonator based all-fiber RI sensor featuring controllable sensitivity and compact size can be widely used for chemical and biological detections. The proposed scheme of generating Vernier effect also offers a universal idea to increase measurement sensitivity for optical fiber sensing structures with comb spectrum.
Similar content being viewed by others
Introduction
Refractive index (RI) of liquid is a basic quantity that can be applied to characterize the changes of many chemical and biological measurands, such as gas concentration1, seawater salinity2, PH values3, DNA4, glucose concentration in serum5, etc. Resulting from the important roles in the chemical and biological fields, developing sensitive optical RI detectors is of fundamental interest and great significance6,7,8. Benefiting from the unique advantages of thin diameter and large evanescent field, microfiber is believed to be an excellent medium for constructing miniature RI sensors9, 10. Indeed, abundant microfiber refractometers were developed in the past years. Microfiber gratings once attracted considerable attention, due to their narrow bandwidth, small size and good measurement accuracy. But the complicated fabrication processes, fragile structures and rough packaging limit their practical applications11,12,13,14,15. Microfiber in-line interferometers such as modal interferometers and Fabry-Perot interferometers (FPIs) were also investigated for RI sensing16,17,18,19. As illustration, Wen Bin Jin et al. utilized a non-adiabatic microfiber assisted by facet reflection of a patch cord to realize an RI sensor with sensitivity high to 18681.82ânm/RIU (refractive index unit)18. Nevertheless, these sensing structures encounter problems of uncontrollable fabricating process and poor re-configurability. Moreover, due to the features of high Q-factor, further-reduced size, and easy fabrication, much effort has been dedicated to RI sensors based on microfiber resonators20,21,22. For instance, an embedded microfiber coil resonator was studied for RI detection with resolution as low as 10â10, whereas its sensitivity is only 700ânm/RIU even when the microfiber diameter is down to 300 nm20. Aside from the short sensitivity, the existing resonators always rely on additional fiber tapers to lead transmission signal out, which further makes the microfiber resonator systems fragile and lossy. A reflective microfiber resonator can cover the shortage but has not been reported yet.
As an efficient way to enhance measurement sensitivity, Vernier effect has attracted considerable attention from the optical sensing field. Vernier effect induced by two cascaded silicon micro-ring resonator has been abundantly studied for RI detection23,24,25. But the high cost and incompatibility with fiber devices are obstacles to their applications in the popular fiber systems. As for the fiber based Vernier effect, cascaded fiber ring resonators26 and cascaded intrinsic FPIs27 are demonstrated the ability of effectively measuring strain and magnetic field, respectively. Nevertheless, they are unable to measure RI due to lack of effective interaction with analyte. Furthermore, the existing structures with Venier effect are usually composed of two identical elements23,24,25,26,27, one as sensing element and the other as reference element. However, in these situations, the reference elements usually cannot fully isolate from the measurand and thus will disturb the sensing results.
In this paper, we propose a sensitivity-controllable RI probe based on a robust θ-shaped microfiber resonator cooperated with Vernier effect. The θ-shaped microfiber resonator is a specially designed all-fiber reflective device with comb spectrum under weak coupling condition. By cascading the θ-shaped microfiber resonator with a fiber Fabry-Perot interferometer (FFPI), Vernier effect is generated to demodulate surrounding RI variation with enhanced sensitivity. Both theoretical analyses and experimental demonstration are conducted to investigate the sensing performances of the proposed RI sensor.
Results
Optical and RI sensing characteristics of the θ-shaped microfiber resonator
Schematic of the θ-shaped microfiber resonator is shown in Fig. 1, where an elliptical cavity is divided by a âmicro-bridgeâ into shape of character âθâ. In the structure, coupling efficiencies and coupling losses of two couplers I, II are (κ 1, γ 1) and (κ 2, γ 2) respectively, as marked in Fig. 1(a). In this work, κ 1â=âκ 2â=âκ and γ 1â=âγ 2â=âγ are taken for simplification, since the two couplers are symmetric for the resonator. Referring to Fig. 1(a), light is launched into the cavity through port 1, and clockwise (CW) mode oscillation along path of 2-5-7-4-2-5-7-â¦â¦is initially generated. In the propagation process, the CW mode arriving at the coupler I or the coupler II will be divided into two branches. One branch straightly passing through the coupler maintains oscillation as the CW mode, while the other branch being routed to the micro-bridge is converted into a counter clockwise (CCW) mode along the path of 4-7-5-2-4-7-5-â¦â¦A part of CCW signal can be output as reflection through port 1, as indicated in Fig. 1(a). By using coupled mode theory, reflectance of the resonator can be derived as:
Here, β is the propagation constant of resonant modes in the θ-shaped microfiber resonator. l 0, l 1 and l 2 are the distances of micro-bridge (port 3-port 6), upper arm (port 2-port 5), lower arm (port 7-port 4), respectively. Lâ=âl 1â+âl 2 is the length of main cavity. Then the reflection amplitude can be calculated by \({\rm{R}}={|r|}^{2}\). It can be inferred from Eq. (1) that under weak coupling condition, namely the coupling coefficient κ is relatively small (κâ<â0.2) and coupling loss γ is relatively high (γâ>â0.1), the reflective θ-shaped microfiber resonator is comb spectrum. A typical reflection spectrum of the θ-shaped microfiber resonator with κâ=â0.1 and γâ=â0.5 is shown in Fig. 1(b).
Equation (1) also indicates that the reflection spectrum of the θ-shaped microfiber resonator is partly determined by the propagation constant β. Since light in the θ-shaped microfiber resonator is guided as evanescent wave, change of the RI in surrounding medium will result in the change of the propagation constant β, causing the resonant wavelength in the reflection spectrum to be shifted. Assuming that the surrounding RI n a is varied by În a , the resonant wavelength λ 1 will be changed by:
Then, RI sensitivity of the θ-shaped microfiber resonator can be expressed as:
where n eff1 and În eff1 are the original effective RI of modes in θ-shaped microfiber resonator and its variation. În eff1/În a means the rate of change of effective mode RI to the change of surrounding RI, which is determined by the microfiber diameter. λ 1is the operating wavelength. By applying the parameters in Table 1 into Eqs (1â3), we calculate the RI sensitivity of the θ-shaped microfiber to be 24.58ânm/RIU, which, however, is ultra-limited for most chemical and biological applications. Although decreasing the microfiber diameter might increase the RI sensitivity due to a larger value of În eff1/În a 28, the increment would still be too little to be counted on. Therefore, another effective way to enhance the RI sensitivity is highly desired.
Vernier effect between θ-shaped microfiber resonator and FFPI
Considering its ability of effectively enhancing measurement sensitivity, Vernier effect occurs to us as a potential method to increase the RI sensitivity. Since the refection spectrum of the θ-shaped microfiber resonator is comb spectrum, another comb spectrum should be employed to induce Vernier effect. As an optically stable and commercially accessible fiber device, FFPI is definitely a good candidate for achieving the other comb spectrum. Based on the above analysis, the θ-shaped microfiber resonator is cascaded with a FFPI to generate Vernier effect, as shown in Fig. 2(b). This also offers a universal idea of generating Vernier effect to increase measurement sensitivity for other fiber sensing structures with comb spectra.
In order to generate Vernier effect, free spectrum ranges (FSRs) of the θ-shaped microfiber resonator (FSR 1) and the FFPI (FSR 2) should meet the rule of \(FS{R}_{1}/FS{R}_{2}=m/(m+1)\,(m=1,\,2,\,3,\ldots )\). Then, periodicity of the resulting Vernier spectrum (FSR r ) can be deduced as23,24,25,26,27:
where FSR 1 can be obtained by \(FS{R}_{1}={\lambda }^{2}/{n}_{eff1}L\), and FSR 2 can be chosen from the commercial FFPI. It is obvious that FSR r is m times higher than FSR 1, as illustrated in Fig. 3. Due to the spectrum magnification function of the Vernier effect, the RI sensitivity of the θ-shaped microfiber resonator after cascading with the FFPI will be magnified, and can be inferred as23:
It is found from Eqs (3) and (5) that compared with the sensitivity of singular θ-shaped microfiber resonator, the sensitivity after combining with a FFPI is enhanced by \(M=[FS{R}_{2}/(FS{R}_{2}-FS{R}_{1})]=(m+1)\), because of which M is defined as the magnification factor. Additionally, since FSR 1 can be tuned by adjusting the cavity length of the θ-shaped microfiber resonator, the M can also be tuned, enabling the RI sensitivity of the combined structure to be controllable. The RI sensitivity-controllability of the θ-shaped microfiber resonator endorses it to meet different requirements of various applications.
Experimental spectra of the θ-shaped microfiber resonator and Vernier effect
FSR of the FFPI (FSR 2) utilized in this paper is 0.2ânm. Therefore, the FSR of the θ-shaped microfiber resonator (FSR 1) should be controlled approaching 0.2ânm in accordance with the rule in Eq. (4). An experimentally measured reflection spectrum of the θ-shaped microfiber resonator and the induced Vernier spectrum are shown in Fig. 4(a) and (b), where the FSRs are 0.194ânm and 6.253ânm, respectively. About 31 fringes exist within a Vernier period, corresponding to a Vernier effect induced magnification factor of Mâ=â31. Then, we changed the FSR 1 into 0.196ânm by adjusting the cavity length of θ-shaped microfiber resonator as shown in Fig. 4(c). FSR r was changed accordingly to 8.917ânm, as illustrated in Fig. 4(d), which demonstrates the tunablity of the Vernier spectrum.
Basic RI detection performance
In the experiment, the surrounding RI was changed from 1.3319 to 1.3550 by using glycerin solution with different concentration. Transmission spectra under different surrounding RIs are presented in Fig. 5(a). To accurately locate the peak of Vernier envelope and continuously measure the RI changing, Lorentz fitting algorithm is applied to a chosen period of the Vernier spectra, as illustrated by black lines in Fig. 5(a) 25. The center of the Lorentz fitting curve is regarded as the Vernier peak of the chosen period. It is clearly observed from Fig. 5(a) that the Vernier peak shifts to longer wavelength as the RI increasing. Wavelength shift of the Vernier peak as a function of surrounding RI is displayed in Fig. 5(b). The RI sensitivity is measured to be 514.4ânm/RIU, with linearity of R 2â=â0.998.
RI sensitivity controllability
In order to demonstrate the controllability of RI sensitivity, we adjusted the cavity length of the fabricated θ-shaped microfiber resonator by manually pulling the microfiber pigtail. In the experiment, we recorded the spectra of the θ-shaped microfiber resonator when its cavity length L was tuned to be 9.4âmm, 9âmm and 8.7âmm. The FSRs in the reflection spectra of the θ-shaped microfiber resonator under the three conditions #1, #2 and #3 are calculated as 0.184ânm, 0.194ânm and 0.198ânm, respectively. After cascading with a FFPI with FSR of 0.2ânm, the induced Vernier spectra has different periods of 2.22ânm, 6.01ânm and 14.45ânm, respectively, as shown in Fig. 6(a). The sub-fringes contained in the three Vernier spectra can be counted as 11, 30 and 72, which means their magnification factors M are 12, 31 and 73 respectively. The relationships between the wavelength shifts of three microfiber resonators and surrounding RIs are shown in Fig. 6(b). Their RI sensitivities are 311.77ânm/RIU, 514.41ânm/RIU, and 2460.07ânm/RIU separately, indicating that the RI sensitivity of the θ-shaped microfiber resonator can be controlled by adjusting the cavity length.
Discussions
In the investigation of RI sensitivity controllability, the sensitivities do not strictly follow the ratio of magnification factors M, which may result from the un-absolutely uniform microfiber diameter. According to Eq. (5), the deceasing of microfiber diameter will cause the increasing of În eff1/În a 28 and thus lead the RI sensitivity to be enhanced. In the experiment, limited by the manufacturing platform, the shape of fabricated microfiber is not a cylinder with uniform diameter along the length, but a circular cone with slowly increasing diameter. When pulling the pigtail to adjust cavity length of the θ-shaped microfiber resonator, the microfiber diameter forming the main cavity alters, inducing the sensitivity of the proposed RI sensor to change more or less. In order to conquer this problem, we need to increase the length of microfiber waist, which can be realized by stretching the fiber on both ends and scanning the oxyhydrogen flame over lengths of several tens ofâmm along the fiber during the fabrication process.
As indicated by Eq. (5), the magnification factor M is also related to the effective RI of the modes in the θ-shaped microfiber resonator which is susceptible to surrounding temperature. Therefore, in the future work, we can tune the sensitivity through controlling the temperature around the packaged θ-shaped microfiber resonator, which can be easily implemented by putting it onto a temperature-controllable hotplate.
In summary, we have experimentally demonstrated a reflective θ-shaped microfiber resonator based RI sensor with controllable sensitivity. The θ-shaped microfiber resonator is a specially designed all-fiber structure with comb spectrum under weak coupling condition. By analyzing the mode propagation process, we show that the θ-shaped microfiber resonator could act as a reflective device, which makes it compact, portable, and easily compatible with other fiber devices in practical applications. Benefitting from the large evanescent field of microfiber, the θ-shaped microfiber resonator can perceive the change of surrounding RI, whereas the RI sensitivity is ultra-limited as investigated. In order to enhance the RI sensitivity, we cascade the θ-shaped microfiber resonator with a FFPI to generate Vernier effect. It is because of the Vernier effect and the tunability of the θ-shaped microfiber resonator that the RI sensitivity is enhanced and controllable. Our theoretical analysis and experimental results verify the above expectation. Theoretically, we show that the RI sensitivity of the combined structure with Vernier effect is m times higher than the sensitivity of singular θ-shaped microfiber resonator. Moreover, by accommodating cavity length of the θ-shaped microfiber resonator, the magnification factor Mâ=â(mâ+â1) can be tuned which enables the RI sensitivity to be controled. Experimentally, we verify that the RI sensitivity can be widely tuned from 311.77ânm/RIU to 2460.07ânm/RIU when the cavity length of the θ-shaped microfiber resonator is adjusted from 9.4âmm to 8.7âmm. The θ-shaped microfiber resonator based all-fiber RI sensor featuring controllable sensitivity and compact size can be widely used for chemical and biological detections. The proposed scheme of generating Vernier effect also offers a universal idea to increase measurement sensitivity for other optical fiber sensing structures with comb spectrum.
Methods
Fabrication
Fabrication process of the θ-shaped microfiber resonator is outlined in the schematic of Fig. 2(a). Firstly, a microfiber fabricated by flame-heated taper-drawing technique is cut off to form a free microfiber pigtail. Then, after being anchored onto the ridge of a substrate, the free microfiber pigtail is bent and tied twice, forming a θ-shaped cavity. Finally, by slightly adjusting the cavity length and two couplers, a θ-shaped microfiber resonator is completed. In the experiment, by using a microfiber with length of 75âmm and waist diameter of 2âμm, a θ-shaped microfiber resonator with size of 4âmmâÃâ2âmm is assembled, as presented in the inset of Fig. 2(b). The propagation loss of microfibers is measured as low as 1âdB. Due to the thin diameter and the extremely good flexibility of microfiber, its bending loss can be ignored. In order to keep stable, the fabricated θ-shaped microfiber resonator is placed on a silica substrate coated by Teflon with RI of 1.292429.
Experimental setup
Experimental setup for RI sensing characterization of the θ-shaped microfiber resonator is displayed in Fig. 2(b). The light launched from a static optical sensing interrogator (Micron Optics, SM125) flows to the θ-shaped microfiber resonator through the port 2 and port 3 of a circulator. Then the reflected light from the θ-shaped microfiber resonator enters the FFPI (FSR 2â=â0.2ânm, Micron Optics, FFP-I) through port 4 of the circulator. Finally, the transmitted light from FFPI comes back to the interrogator through port 1 of the circulator and is detected by the interrogator. Measurement and recording of the spectra are conducted in a computer with a bundled software.
RI sensing experiment
To change the surrounding RI of the θ-shaped microfiber resonator, a batch of glycerin solution with different concentration is tested in the experiment. After each test, we drain out the used glycerin solution, thoroughly clean the substrate on which the θ-shaped microfiber resonator is supported, and then carefully drop new glycerin solution. The corresponding RI of the glycerin solution is calibrated by an Abbe refractometer.
References
Yao, B. C. et al. Graphene enhanced evanescent field in microfiber multimode interferometer for highly sensitive gas sensing. Opt. Express 22, 28154â28162 (2014).
Liao, Y., Wang, J., Wang, S., Yang, H. & Wang, X. Simultaneous measurement of seawater temperature and salinity based on microfiber MZ interferometer with a knot resonator. J. Lightwave Technol. 34, 5378â5384 (2016).
Li, W., Cheng, H., Xia, M. & Yang, K. An experimental study of pH optical sensor using a section of no-core fiber. Sens. Actuators A 199, 260â264 (2013).
Sun, D., Guo, T., Ran, Y., Huang, Y. & Guan, B. O. In-situ DNA hybridization detection with a reflective microfiber grating biosensor. Biosens. Bioelectron. 641, 541â546 (2014).
Luo, B., Yan, Z., Sun, Z., Li, J. & Zhang, L. Novel glucose sensor based on enzyme-immobilized 81° tilted fiber grating. Opt. Express 22, 30571â30578 (2014).
Zhu, H., Wang, Y. & Li, B. Tunable refractive index sensor with ultracompact structure twisted by poly (trimethylene terephthalate) nanowires. Nano 3, 3110â3114 (2009).
Tai, Y. H. & Wei, P. K. Sensitive liquid refractive index sensors using tapered optical fiber tips. Opt. Lett. 35, 944â946 (2010).
Xu, Z. et al. Highly sensitive refractive index sensor based on cascaded microfiber knots with Vernier effect. Opt. Express 23, 6662â6672 (2015).
Tong, L. et al. Subwavelength-diameter silica wires for low-loss optical wave guiding. Nature 426, 816â819 (2003).
Brambilla, G. et al. Optical fiber nanowires and microwires: fabrication and applications. Adv. Opt. and Photon. 1, 107â161 (2009).
Zhang, Y. et al. Refractive index sensing based on higher-order mode reflection of a microfiber Bragg grating. Opt. Express 18, 26345â26350 (2010).
Liang, R., Sun, Q., Zhang, J. & Liu, D. Investigation on micro/nanofiber Bragg grating for refractive index sensing. Opt. Commun. 285, 1128â1133 (2012).
Xuan, H. F., Jin, W. & Zhang, M. CO2 laser induced long period gratings in optical microfibers. Opt. Express 17, 21882â21890 (2009).
Zhang, J. et al. Microfiber FabryâPerot interferometer for dual-parameter sensing. J. Lightwave Technol. 31, 1608â1615 (2013).
Jin, W., Xuan, H. & Jin, W. Long period gratings in highly birefringent microfibers. Proc. SPIE 9157, (91577N (2014).
Kou, J., Feng, J., Wang, Q., Xu, F. & Lu, Y. Q. Microfiber-probe-based ultrasmall interferometric sensor. Opt. Lett. 35, 2308â2310 (2010).
Zhang, J. et al. Microfiber FabryâPerot interferometer fabricated by taper-drawing technique and its application as a radio frequency interrogated refractive index sensor. Opt. Lett. 37, 2925â2927 (2012).
Ji, W. B., Liu, H. H., Tjin, S. C., Chou, K. K. & Lim, A. Ultrahigh sensitivity refractive index sensor based on optical microfiber. IEEE Photon. Technol. Lett. 24, 1872â1874 (2012).
Salceda-Delgado, G., Monzon-Hernandez, D., Martinez-Rios, A., Cardenas-Sevilla, G. A. & Villatoro, J. Optical microfiber mode interferometer for temperature-independent refractometric sensing. Opt. Lett. 37, 1974â1976 (2012).
Xu, F., Horak, P. & Brambilla, G. Optical microfiber coil resonator refractometric sensor. Opt. Express 15, 7888â7893 (2007).
Guo, X. & Tong, L. Supported microfiber loops for optical sensing. Opt. Express 16, 14429â14434 (2008).
Xu, F., Pruneri, V., Finazzi, V. & Brambilla, G. An embedded optical nanowire loop resonator refractometric sensor. Opt. Express 16, 1062â1067 (2008).
Dai, D. Highly sensitive digital optical sensor based on cascaded high-Q ring-resonators. Opt. Express 17, 23817â23822 (2009).
Hu, J. & Dao, D. Cascaded-ring optical sensor with enhanced sensitivity by using suspended Si-nanowires. IEEE Photon. Technol. Lett. 23, 842â844 (2011).
Claes, T., Bogaerts, W. & Bienstman, P. Experimental characterization of a silicon photonic biosensor consisting of two cascaded ring resonators based on the Vernier-effect and introduction of a curve fitting method for an improved detection limit. Opt. Express 18, 22747â22761 (2010).
Xu, R., Liu, S., Sun, Q., Lu, P. & Liu, D. Experimental characterization of a Vernier strain sensor using cascaded fiber rings. IEEE Photon. Technol. Lett. 24, 2125â2128 (2012).
Zhang, P. et al. Cascaded fiber-optic Fabry-Perot interferometers with Vernier effect for highly sensitive measurement of axial strain and magnetic field. Opt. Express 22, 19581â19588 (2014).
Wo, J. et al. Refractive index sensor using microfiber-based MachâZehnder interferometer. Opt. Lett. 37, 67â69 (2012).
Yang, M. K., French, R. H. & Tokarsky, E. W. Optical properties of Teflon® AF amorphous fluoropolymers. J. Micro/Nanolithography, MEMS, and MOEMS 7, 033010-033010-9 (2008).
Acknowledgements
This work is supported by the National Natural Science Foundation of China (No. 61290315, 61275004), the Natural Science Foundation of Hubei Province for Distinguished Young Scholars (No. 2014CFA036). and the European Commissionâs Marie Curie International Incoming fellowship (Grant No. 912263). Zhilin Xu acknowledges the funding from Ministry of Education of Singapore Tier 2 project (MOE2014-T2-1-076).
Author information
Authors and Affiliations
Contributions
Z.L.X. and Y.Y.L. proposed the idea, designed the study and jointly conducted the experiment. Z.L.X. wrote the manuscript, analyzed the data and drew the figures. P.P.S. and D.L. provided advice and instructional discussion. Q.Z.S. supervised the study. All authors reviewed the manuscript.
Corresponding author
Ethics declarations
Competing Interests
The authors declare that they have no competing interests.
Additional information
Publisher's note: Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the articleâs Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the articleâs Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Xu, Z., Luo, Y., Liu, D. et al. Sensitivity-controllable refractive index sensor based on reflective θ-shaped microfiber resonator cooperated with Vernier effect. Sci Rep 7, 9620 (2017). https://doi.org/10.1038/s41598-017-10163-x
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-017-10163-x
This article is cited by
-
Efficiently Writing Bragg Grating in High-Birefringence Elliptical Microfiber for Label-Free Immunosensing with Temperature Compensation
Advanced Fiber Materials (2021)
-
Recent Progress in Microfiber-Optic Sensors
Photonic Sensors (2021)
-
Experimental demonstration of tunable refractometer based on orbital angular momentum of longitudinally structured light
Light: Science & Applications (2018)
Comments
By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.