This article is missing information about Explanation of the mathematics of throat area and pressure ratios determining Mach number, explanation of the meaning of the symbols in "minimum required pressure ratio", and the promised examples.(October 2014) |
A supersonic wind tunnel is a wind tunnel that produces supersonic speeds (1.2<M<5) The Mach number and flow are determined by the nozzle geometry. The Reynolds number is varied by changing the density level (pressure in the settling chamber). Therefore, a high pressure ratio is required (for a supersonic regime at M=4, this ratio is of the order of 10). Apart from that, condensation of moisture or even gas liquefaction can occur if the static temperature becomes cold enough. This means that a supersonic wind tunnel usually needs a drying or a pre-heating facility. A supersonic wind tunnel has a large power demand, so most are designed for intermittent instead of continuous operation.
The first supersonic wind tunnel (with a cross section of 2 cm) was built in National Physical Laboratory in England, and started working in 1922.
Power requirements
editThe power required to run a supersonic wind tunnel is enormous, of the order of 50 MW per square meter of test section cross-sectional area. For this reason most wind tunnels operate intermittently using energy stored in high-pressure tanks. These wind tunnels are also called intermittent supersonic blowdown wind tunnels (of which a schematic preview is given below). Another way of achieving the huge power output is with the use of a vacuum storage tank. These tunnels are called indraft supersonic wind tunnels, and are seldom used because they are restricted to low Reynolds numbers. Some large countries have built major supersonic tunnels that run continuously; one is shown in the photo. Other problems operating a supersonic wind tunnel include:
- starting and unstart of the test section (related to maintaining at least a minimum pressure ratio)
- adequate supply of dry air
- wall interference effects due to shock wave reflection and (sometimes) blockage
- high-quality instruments capable of rapid measurements due to short run times in intermittent tunnels
Tunnels such as a Ludwieg tube have short test times (usually less than one second), relatively high Reynolds number, and low power requirements.
Further reading
edit- Pope, A.; Goin, K. (1978). High-speed Wind Tunnel Testing. Krieger. ISBN 0-88275-727-X.