Omron E2el
Omron E2el
Omron E2el
E2EL
Increased response
frequency for high speed
applications
Ordering Information
Cable types
Brass housing
6,5
M8
Output
Length
Mounting
Sensing
Distance
NPN / NO
NPN / NC
PNP / NO
PNP / NC
30 mm
Shielded
1,5 mm
E2EL-C1R5E1 2M
E2EL-C1R5E2 2M
E2EL-C1R5F1 2M
E2EL-C1R5F2 2M
32 mm
Non-shielded
2,0 mm
E2EL-C2ME1 2M
E2EL-C2ME2 2M
E2EL-C2MF1 2M
E2EL-C2MF2 2M
45 mm
Shielded
1,5 mm
E2EL-C1R5E1-L 2M
E2EL-C1R5E2-L 2M
E2EL-C1R5F1-L 2M
E2EL-C1R5F2-L 2M
47 mm
Non-shielded
2,0 mm
E2EL-C2ME1-L 2M
E2EL-C2ME2-L 2M
E2EL-C2MF1-L 2M
E2EL-C2MF2-L 2M
30 mm
Shielded
1,5 mm
E2EL-X1R5E1 2M
E2EL-X1R5E2 2M
E2EL-X1R5F1 2M
E2EL-X1R5F2 2M
32 mm
Non-shielded
2,0 mm
E2EL-X2ME1 2M
E2EL-X2ME2 2M
E2EL-X2MF1 2M
E2EL-X2MF2 2M
45 mm
Shielded
1,5 mm
E2EL-X1R5E1-L 2M
E2EL-X1R5E2-L 2M
E2EL-X1R5F1-L 2M
E2EL-X1R5F2-L 2M
47 mm
Non-shielded
2,0 mm
E2EL-X2ME1-L 2M
E2EL-X2ME2-L 2M
E2EL-X2MF1-L 2M
E2EL-X2MF2-L 2M
Length
Mounting
Sensing
Distance
NPN / NO
NPN / NC
PNP / NO
PNP / NC
30 mm
Shielded
2,0 mm
E2EL-C2E1-DS 2M
E2EL-C2E2-DS 2M
E2EL-C2F1-DS 2M
E2EL-C2F2-DS 2M
45 mm
Shielded
2,0 mm
30 mm
Shielded
2,0 mm
E2EL-X2E1-DS 2M
E2EL-X2E2-DS 2M
E2EL-X2F1-DS 2M
E2EL-X2F2-DS 2M
45 mm
Shielded
2,0 mm
E2EL-X2E1-DSL 2M E2EL-X2E2-DSL 2M
E2EL-X2F1-DSL 2M
E2EL-X2F2-DSL 2M
Length
Mounting
Sensing
Distance
NPN / NO
NPN / NC
PNP / NO
PNP / NC
45 mm
Shielded
1,5 mm
E2EL-C1R5E1-M3
E2EL-C1R5E2-M3
E2EL-C1R5F1-M3
E2EL-C1R5F2-M3
47 mm
Non-shielded
2,0 mm
E2EL-C2ME1-M3
E2EL-C2ME2-M3
E2EL-C2MF1-M3
E2EL-C2MF2-M3
54 mm
Shielded
1,5 mm
E2EL-C1R5E1-M3L
E2EL-C1R5E2-M3L
E2EL-C1R5F1-M3L
E2EL-C1R5F2-M3L
Output
Plug types
Brass housing
Diameter
6,5 /
Plug M8
M8 /
Plug M8
M8 /
Plug M12
E2EL
Output
56 mm
Non-shielded
2,0 mm
E2EL-C2ME1-M3L
E2EL-C2ME2-M3L
E2EL-C2MF1-M3L
E2EL-C2MF2-M3L
45 mm
Shielded
1,5 mm
E2EL-X1R5E1-M3
E2EL-X1R5E2-M3
E2EL-X1R5F1-M3
E2EL-X1R5F2-M3
47 mm
Non-shielded
2,0 mm
E2EL-X2ME1-M3
E2EL-X2ME2-M3
E2EL-X2MF1-M3
E2EL-X2MF2-M3
54 mm
Shielded
1,5 mm
E2EL-X1R5E1-M3L
E2EL-X1R5E2-M3L
E2EL-X1R5F1-M3L
E2EL-X1R5F2-M3L
56 mm
Non-shielded
2,0 mm
E2EL-X2ME1-M3L
E2EL-X2ME2-M3L
E2EL-X2MF1-M3L
E2EL-X2MF2-M3L
44 mm
Shielded
1,5 mm
E2EL-X1R5E1-M1
E2EL-X1R5E2-M1
E2EL-X1R5F1-M1
E2EL-X1R5F2-M1
46 mm
Non-shielded
2,0 mm
E2EL-X2ME1-M1
E2EL-X2ME2-M1
E2EL-X2MF1-M1
E2EL-X2MF2-M1
60 mm
Shielded
1,5 mm
E2EL-X1R5E1-M1L
E2EL-X1R5E2-M1L
E2EL-X1R5F1-M1L
E2EL-X1R5F2-M1L
62 mm
Non-shielded
2,0 mm
E2EL-X2ME1-M1L
E2EL-X2ME2-M1L
E2EL-X2MF1-M1L
E2EL-X2MF2-M1L
D-99
E2EL
Diameter
Specifications
Brass type
Type
6,5
Operating voltage
Rated supply voltage
Current consumption
Sensing object
Mounting ((s)hielded, (n)on-shielded) *1
Operating distance in mm
Tolerance of operating distance
Standard target size in mm (L x W x H in mm, FE 37)
Differential travel
Max. response frequency in kHz
10 to 35 VDC
24 VDC
max. 15 mA at 24 VDC
Ferrous metals
s
n
s
n
1,5
2,0
1,5
2,0
10%
6,5x6,5x1
8x8x1
1 % ... 15 % of operating distance
5,0
E2EL-... E1 type: NPN-NO
E2 type: NPN-NC
F1 type: PNP-NO
F2 type: PNP-NC
200 mA
2,5 VDC (at 200mA load current and with 2 m cable)
Type
Control output
Max-Load
Max-on-state
Voltage drop
Circuit protection
Indicator
Ambient temperature
Humidity
Influence of temperature
Pre-wired
Connector
long
45
50
short
43
48
long
10
15
short
13
Case
Sensing face
Brass
PBTP
Dielectric strength
Electromagnetic compatibility EMC
Vibration resistance
Shock resistance
Enclosure rating
Connection *2
Pre-wired
Weight in g
Connector
Material
*1.
*2.
M8
D-100
Inductive Sensors
6,5
Operating voltage
Rated supply voltage
Current consumption
Sensing object
Mounting *1
Operating distance in mm
Tolerance of operating distance
Standard target size in mm (L x W x H in mm, FE 37)
Differential travel
Max. response frequency in kHz
10 to 35 VDC
24 VDC
max. 15 mA at 24 VDC
Ferrous metals
shielded
2,0
10%
6,5x6,5x1
1 % ... 15 % of operating distance
4,0
E2EL-... E1 type: NPN-NO
Control output
Max-Load
Max-on-state
Voltage drop
Circuit protection
Indicator
Ambient temperature
Humidity
Influence of temperature
Dielectric strength
Electromagnetic compatibility EMC
Vibration resistance
Shock resistance
Enclosure rating
Connection *2
Pre-wired
Weight in g
Connector
Material
*1.
*2.
Pre-wired
Connector
long
short
long
short
Case
Sensing face
8x8x1
E2 type: NPN-NC
F1 type: PNP-NO
F2 type: PNP-NC
200 mA
2,5 VDC (at 200mA load current and with 2 m cable)
Reverse polarity, output short-circuit
Operating indicator (yellow LED)
Operating: -25 to 70C
35 to 95 % RH
10 % max. of Sn at 23C in temperature range of -25 to 70C
1.500 VAC, 50/60 Hz for 1 min. between current carry parts and case
EN 60947-5-2
Destruction: 10 to 70 Hz, 1,5 mm double amplitude for 1 hour each in X, Y
and Z directions
Destruction: 300 m/s (approx. 30 G) for 6 times each in X, Y and Z directions
IP 67 (EN 60947-1)
2 m PVC-cable, 3 x 0,14 mm
M8 plug
45
50
43
48
10
stainless steel 1.4305 / AISI 303
PBTP
E2EL
D-101
E2EL
Type
M8
Engineering data
1,2
axial
approach
standard target
1
'switch-on' curve
' switch-off' curve
0,8
lateral approach
0,6
(s/sr)
on
off
0,4
0,2
0
-1
-0,8
-0,6
-0,4
-0,2
0,2
0,4
0,6
0,8
E2EL-@F@
PNP Output
Brown 1
Brown 1
Load
4,7 kW
Main
circuit
Black 4 (or 2)
Main
circuit
Black 4 (or 2)
4,7 kW
0V
Blue 3
Blue 3
E2EL-@E@
NPN Output
E2EL-@F@
PNP Output
NO
NC
Yes
No
Lit
Not lit
ON
OFF
Sensing object
Yellow indicator
Control output
Load
Sensing object
Yellow indicator
Yes
No
Lit
Not lit
NC
NO
ON
OFF
Control output
Output
D-102
NO
2 free
1 (+)
2 Output
1 (+)
3 (-)
4 Output
3 (-)
4 free
Inductive Sensors
Dimensions
Cable types
E2EL-C2M@ 2M
E2EL-C2M@-L 2M
E2ELX2M @ 2M
E2ELX2M@ L 2M
E2EL
E2EL
D-103
Plug types
E2EL-C1R5@-M3
E2EL-C2M@-M3
E2EL-C1R5@-M3L
E2EL-C2M@-M3L
E2ELX1R5@ M3
E2ELX2M@ M3
E2ELX2M @M3L
E2ELX1R5@ M1
E2ELX2M@ M1
E2ELX1R5@ M1L
E2ELX2M@ M1L
D-104
Inductive Sensors
Installation
Caution
Item
Examples
Power Supply
Do not impose an excessive voltage on the E2EL, otherwise it may
explode or burn.
Do not impose 24 VAC on any E2EL model, otherwise it may explode or burn.
Load short-circuit
Do not short-circuit the load, or the E2EL may explode or burn.
The E2EL's short-circuit protection function is valid, if the polarity of
the supply voltage imposed is incorrect and within the rated voltage
range.
Wiring
Be sure to wire the E2EL and load correctly, otherwise it may explode or burn.
Wiring
Installation
High-tension Lines
Power OFF
The Proximity Sensor may output a pulse signal when it is turned
off. Therefore, it is recommended to turn off the load before turning off the Proximity Sensor.
Sensing Object
Metal Coating:
The sensing distance of the Proximity Sensor vary with the metal
coating on sensing objects.
E2EL
Correct Use
Mounting
The Proximity Sensor must not be subjected to excessive shock
with a ha mmer when it is installed, otherwise the Proximity Sensor may be damaged or lose the water-resistivity.
Environment
Water-Resistivity
Do not use the Proximity Sensor underwater, outdoors or in the
rain.
Operating Environment
Be sure to use the Proximity Sensor within operating ambient
temperature range and do not use the Proximity Sensor outdoors
so that its reliability and life expectancy can be maintained. Although the Proximity Sensor is water resistive, a cover to protect
the Proximity Sensor from water or soluble machining oil is reco
mmended so that its reliability and life expectancy can be maintained. Do not use the Proximity Sensor in an environment with
chemical gas (e. G., strong alkaline or acid gases including nitric,
chromic, and concentrated sulfuric acid gases).
E2EL
D-105
Item
Examples
OR (parallel connection)
Item
The Sensors connected together must satisfy the
following conditions:
iL + (N-1) x i = Upper-limit of control output of each
Sensor
VS - N x VR = Load operating voltage
N=
No. of Sensors
VR =
Residual voltage of each Sensor
VS =
Supply voltage
i=
Current consumption of the Sensor
iL =
Load current
If the MY Relay, which operate at 24 VDC, is used as a
load for example, a maximum of two Proximity Sensors
can be connected to the load.
The number of Sensors connected in parallel varies
with the Proximity Sensor model.
Non-shielded types:
Shielded types allow direct installation on metal plates in an embedded manner without performance change. A minimum distance of 3sn is required between the active surface and a metallic
surface in front of the device. (Fig. 1).
For SUS shielded types the following minimum distances are required to avoid performance change (see Fig.2 and table below):
3sn
2sn
Free zone
0,5 mm
d 3d
3sn
3sn
D-106
In the interest of product improvement, specifications are subject to change without notice.