Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Omron E2el

Descargar como pdf o txt
Descargar como pdf o txt
Está en la página 1de 8

F502-EN2-04.book Seite 99 Dienstag, 26.

Juli 2005 5:48 17

High Frequency Inductive Proximity Sensor

E2EL
Increased response
frequency for high speed
applications

Max 5 kHz, switching frequency


M8 or dia
6.5 mm housing
Brass or stainless steel housing

Ordering Information
Cable types
Brass housing

6,5

M8

Output

Length

Mounting

Sensing
Distance

NPN / NO

NPN / NC

PNP / NO

PNP / NC

30 mm

Shielded

1,5 mm

E2EL-C1R5E1 2M

E2EL-C1R5E2 2M

E2EL-C1R5F1 2M

E2EL-C1R5F2 2M

32 mm

Non-shielded

2,0 mm

E2EL-C2ME1 2M

E2EL-C2ME2 2M

E2EL-C2MF1 2M

E2EL-C2MF2 2M

45 mm

Shielded

1,5 mm

E2EL-C1R5E1-L 2M

E2EL-C1R5E2-L 2M

E2EL-C1R5F1-L 2M

E2EL-C1R5F2-L 2M

47 mm

Non-shielded

2,0 mm

E2EL-C2ME1-L 2M

E2EL-C2ME2-L 2M

E2EL-C2MF1-L 2M

E2EL-C2MF2-L 2M

30 mm

Shielded

1,5 mm

E2EL-X1R5E1 2M

E2EL-X1R5E2 2M

E2EL-X1R5F1 2M

E2EL-X1R5F2 2M

32 mm

Non-shielded

2,0 mm

E2EL-X2ME1 2M

E2EL-X2ME2 2M

E2EL-X2MF1 2M

E2EL-X2MF2 2M

45 mm

Shielded

1,5 mm

E2EL-X1R5E1-L 2M

E2EL-X1R5E2-L 2M

E2EL-X1R5F1-L 2M

E2EL-X1R5F2-L 2M

47 mm

Non-shielded

2,0 mm

E2EL-X2ME1-L 2M

E2EL-X2ME2-L 2M

E2EL-X2MF1-L 2M

E2EL-X2MF2-L 2M

Length

Mounting

Sensing
Distance

NPN / NO

NPN / NC

PNP / NO

PNP / NC

30 mm

Shielded

2,0 mm

E2EL-C2E1-DS 2M

E2EL-C2E2-DS 2M

E2EL-C2F1-DS 2M

E2EL-C2F2-DS 2M

45 mm

Shielded

2,0 mm

E2EL-C2E1-DSL 2M E2EL-C2E2-DSL 2M E2EL-C2F1-DSL 2M E2EL-C2F2-DSL 2M

30 mm

Shielded

2,0 mm

E2EL-X2E1-DS 2M

E2EL-X2E2-DS 2M

E2EL-X2F1-DS 2M

E2EL-X2F2-DS 2M

45 mm

Shielded

2,0 mm

E2EL-X2E1-DSL 2M E2EL-X2E2-DSL 2M

E2EL-X2F1-DSL 2M

E2EL-X2F2-DSL 2M

Length

Mounting

Sensing
Distance

NPN / NO

NPN / NC

PNP / NO

PNP / NC

45 mm

Shielded

1,5 mm

E2EL-C1R5E1-M3

E2EL-C1R5E2-M3

E2EL-C1R5F1-M3

E2EL-C1R5F2-M3

47 mm

Non-shielded

2,0 mm

E2EL-C2ME1-M3

E2EL-C2ME2-M3

E2EL-C2MF1-M3

E2EL-C2MF2-M3

54 mm

Shielded

1,5 mm

E2EL-C1R5E1-M3L

E2EL-C1R5E2-M3L

E2EL-C1R5F1-M3L

E2EL-C1R5F2-M3L

Stainless steel housing


Diameter
6,5
M8

Output

Plug types
Brass housing
Diameter

6,5 /
Plug M8

M8 /
Plug M8

M8 /
Plug M12

E2EL

Output

56 mm

Non-shielded

2,0 mm

E2EL-C2ME1-M3L

E2EL-C2ME2-M3L

E2EL-C2MF1-M3L

E2EL-C2MF2-M3L

45 mm

Shielded

1,5 mm

E2EL-X1R5E1-M3

E2EL-X1R5E2-M3

E2EL-X1R5F1-M3

E2EL-X1R5F2-M3

47 mm

Non-shielded

2,0 mm

E2EL-X2ME1-M3

E2EL-X2ME2-M3

E2EL-X2MF1-M3

E2EL-X2MF2-M3

54 mm

Shielded

1,5 mm

E2EL-X1R5E1-M3L

E2EL-X1R5E2-M3L

E2EL-X1R5F1-M3L

E2EL-X1R5F2-M3L

56 mm

Non-shielded

2,0 mm

E2EL-X2ME1-M3L

E2EL-X2ME2-M3L

E2EL-X2MF1-M3L

E2EL-X2MF2-M3L

44 mm

Shielded

1,5 mm

E2EL-X1R5E1-M1

E2EL-X1R5E2-M1

E2EL-X1R5F1-M1

E2EL-X1R5F2-M1

46 mm

Non-shielded

2,0 mm

E2EL-X2ME1-M1

E2EL-X2ME2-M1

E2EL-X2MF1-M1

E2EL-X2MF2-M1

60 mm

Shielded

1,5 mm

E2EL-X1R5E1-M1L

E2EL-X1R5E2-M1L

E2EL-X1R5F1-M1L

E2EL-X1R5F2-M1L

62 mm

Non-shielded

2,0 mm

E2EL-X2ME1-M1L

E2EL-X2ME2-M1L

E2EL-X2MF1-M1L

E2EL-X2MF2-M1L

D-99

E2EL

Diameter

F502-EN2-04.book Seite 100 Dienstag, 26. Juli 2005 5:48 17

Specifications
Brass type
Type

6,5

Operating voltage
Rated supply voltage
Current consumption
Sensing object
Mounting ((s)hielded, (n)on-shielded) *1
Operating distance in mm
Tolerance of operating distance
Standard target size in mm (L x W x H in mm, FE 37)
Differential travel
Max. response frequency in kHz

10 to 35 VDC
24 VDC
max. 15 mA at 24 VDC
Ferrous metals
s
n
s
n
1,5
2,0
1,5
2,0
10%
6,5x6,5x1
8x8x1
1 % ... 15 % of operating distance
5,0
E2EL-... E1 type: NPN-NO
E2 type: NPN-NC
F1 type: PNP-NO
F2 type: PNP-NC
200 mA
2,5 VDC (at 200mA load current and with 2 m cable)

Type
Control output
Max-Load
Max-on-state
Voltage drop
Circuit protection
Indicator
Ambient temperature
Humidity
Influence of temperature

Pre-wired
Connector

Reverse polarity, output short-circuit


Operating indicator (yellow LED)
Operating: -25 to 70C
35 to 95 % RH
10 % max. of Sn at 23C in temperature range of -25 to 70C
1.500 VAC, 50/60 Hz for 1 min. between current carry parts and
case
EN 60947-5-2
Destruction: 10 to 70 Hz, 1,5 mm double amplitude for 1 hour each
in X, Y and Z directions
Destruction: 300 m/s (approx. 30 G) for 6 times each in X, Y and Z
directions
IP 67 (EN 60947-1)
2 m PVC-cable, 3 x 0,14 mm
M8 plug

long

45

50

short

43

48

long

10

15

short

13

Case
Sensing face

Brass
PBTP

Dielectric strength
Electromagnetic compatibility EMC
Vibration resistance
Shock resistance
Enclosure rating
Connection *2
Pre-wired
Weight in g
Connector
Material
*1.
*2.

M8

For detailed mounting instruction please refer to page D-105


PUR cable and different length on request.

D-100

Inductive Sensors

F502-EN2-04.book Seite 101 Dienstag, 26. Juli 2005 5:48 17

Stainless steel type


Type

6,5

Operating voltage
Rated supply voltage
Current consumption
Sensing object
Mounting *1
Operating distance in mm
Tolerance of operating distance
Standard target size in mm (L x W x H in mm, FE 37)
Differential travel
Max. response frequency in kHz

10 to 35 VDC
24 VDC
max. 15 mA at 24 VDC
Ferrous metals
shielded
2,0
10%
6,5x6,5x1
1 % ... 15 % of operating distance
4,0
E2EL-... E1 type: NPN-NO

Control output
Max-Load
Max-on-state
Voltage drop
Circuit protection
Indicator
Ambient temperature
Humidity
Influence of temperature
Dielectric strength
Electromagnetic compatibility EMC
Vibration resistance
Shock resistance
Enclosure rating
Connection *2
Pre-wired
Weight in g
Connector
Material
*1.
*2.

Pre-wired
Connector
long
short
long
short
Case
Sensing face

8x8x1

E2 type: NPN-NC
F1 type: PNP-NO
F2 type: PNP-NC
200 mA
2,5 VDC (at 200mA load current and with 2 m cable)
Reverse polarity, output short-circuit
Operating indicator (yellow LED)
Operating: -25 to 70C
35 to 95 % RH
10 % max. of Sn at 23C in temperature range of -25 to 70C
1.500 VAC, 50/60 Hz for 1 min. between current carry parts and case
EN 60947-5-2
Destruction: 10 to 70 Hz, 1,5 mm double amplitude for 1 hour each in X, Y
and Z directions
Destruction: 300 m/s (approx. 30 G) for 6 times each in X, Y and Z directions
IP 67 (EN 60947-1)
2 m PVC-cable, 3 x 0,14 mm
M8 plug
45
50
43
48
10
stainless steel 1.4305 / AISI 303
PBTP

For detailed mounting instruction please refer to page D-105


PUR cable and different length on request.

E2EL

D-101

E2EL

Type

M8

F502-EN2-04.book Seite 102 Dienstag, 26. Juli 2005 5:48 17

Engineering data

1,2
axial
approach

standard target

1
'switch-on' curve
' switch-off' curve

0,8

lateral approach

0,6

(s/sr)

axial distance related to effective operating distance

Standardized characteristic for lateral approach

on

off
0,4

0,2

0
-1

-0,8

-0,6

-0,4

-0,2

0,2

0,4

0,6

0,8

lateral distance related to radius of 'active surface' (r/ract)

Output Circuit Diagram and Timing Chart


E2EL-@E@
NPN Output

E2EL-@F@
PNP Output
Brown 1

Brown 1

Load

4,7 kW
Main
circuit

Black 4 (or 2)

Main
circuit

Black 4 (or 2)

4,7 kW

0V

Blue 3

Blue 3

E2EL-@E@
NPN Output

E2EL-@F@
PNP Output
NO

NC

Yes
No
Lit
Not lit
ON
OFF

Sensing object
Yellow indicator
Control output

Load

Sensing object
Yellow indicator

Yes
No
Lit
Not lit

NC

NO

ON
OFF

Control output

Pin Arrangement at Connector Types


1. Connector M8 (viewed to plug pins)

Output

D-102

2. Connector M12 (viewed to plug pins)


NC

NO
2 free

1 (+)

2 Output

1 (+)

3 (-)

4 Output

3 (-)

4 free

Inductive Sensors

F502-EN2-04.book Seite 103 Dienstag, 26. Juli 2005 5:48 17

Dimensions
Cable types
E2EL-C2M@ 2M

E2EL-C1R5@-L 2M, E2EL-C2@-DSL 2M

E2EL-C2M@-L 2M

E2ELX1R5@ 2M, E2ELX2@ DS 2M

E2ELX2M @ 2M

E2ELX1R5@ L 2M, E2ELX2 @DSL 2M

E2ELX2M@ L 2M

E2EL

E2EL-C1@R5 2M, E2EL-C2@-DS 2M

E2EL

D-103

F502-EN2-04.book Seite 104 Dienstag, 26. Juli 2005 5:48 17

Plug types
E2EL-C1R5@-M3

E2EL-C2M@-M3

E2EL-C1R5@-M3L

E2EL-C2M@-M3L

E2ELX1R5@ M3

E2ELX2M@ M3

E2ELX1R5@ M3L, E2ELX2 @DM3S

E2ELX2M @M3L

E2ELX1R5@ M1

E2ELX2M@ M1

E2ELX1R5@ M1L

E2ELX2M@ M1L

D-104

Inductive Sensors

F502-EN2-04.book Seite 105 Dienstag, 26. Juli 2005 5:48 17

Installation
Caution
Item

Examples

Power Supply
Do not impose an excessive voltage on the E2EL, otherwise it may
explode or burn.
Do not impose 24 VAC on any E2EL model, otherwise it may explode or burn.

Load short-circuit
Do not short-circuit the load, or the E2EL may explode or burn.
The E2EL's short-circuit protection function is valid, if the polarity of
the supply voltage imposed is incorrect and within the rated voltage
range.

Wiring
Be sure to wire the E2EL and load correctly, otherwise it may explode or burn.

Wiring

Installation

High-tension Lines

Power Reset Time

Wiring through Metal Conduit


If there is a power or high-tension line near the cord of the Proximity Sensor, wire the cord through an independent metal conduit
to prevent against Proximity Sensor damage or malfunctioning.

The Proximity Sensor is ready to operate within 100 ms after


power is supplied. If power supplies are connected to the Proximity Sensor and load respectively, be sure to supply power to the
Proximity Sensor before supplying power to the load.

Power OFF
The Proximity Sensor may output a pulse signal when it is turned
off. Therefore, it is recommended to turn off the load before turning off the Proximity Sensor.

Power Supply Transformer


When using a DC power supply, make sure that the DC power
supply has an insulated transformer. Do not use a DC power supply with an auto-transformer.

Sensing Object
Metal Coating:
The sensing distance of the Proximity Sensor vary with the metal
coating on sensing objects.

E2EL

Correct Use

Core Tractive Force


Do not pull cords with the tractive force exceeding the following:
pull force (N) = 20 x cable diameter ( mm)

Mounting
The Proximity Sensor must not be subjected to excessive shock
with a ha mmer when it is installed, otherwise the Proximity Sensor may be damaged or lose the water-resistivity.

Environment
Water-Resistivity
Do not use the Proximity Sensor underwater, outdoors or in the
rain.

Operating Environment
Be sure to use the Proximity Sensor within operating ambient
temperature range and do not use the Proximity Sensor outdoors
so that its reliability and life expectancy can be maintained. Although the Proximity Sensor is water resistive, a cover to protect
the Proximity Sensor from water or soluble machining oil is reco
mmended so that its reliability and life expectancy can be maintained. Do not use the Proximity Sensor in an environment with
chemical gas (e. G., strong alkaline or acid gases including nitric,
chromic, and concentrated sulfuric acid gases).

E2EL

D-105

F502-EN2-04.book Seite 106 Dienstag, 26. Juli 2005 5:48 17

Item

Examples

AND (serial connection)

OR (parallel connection)

Item
The Sensors connected together must satisfy the
following conditions:
iL + (N-1) x i = Upper-limit of control output of each
Sensor
VS - N x VR = Load operating voltage
N=
No. of Sensors
VR =
Residual voltage of each Sensor
VS =
Supply voltage
i=
Current consumption of the Sensor
iL =
Load current
If the MY Relay, which operate at 24 VDC, is used as a
load for example, a maximum of two Proximity Sensors
can be connected to the load.
The number of Sensors connected in parallel varies
with the Proximity Sensor model.

Effects of Surrounding Metal


Shielded types:

Non-shielded types:

Shielded types allow direct installation on metal plates in an embedded manner without performance change. A minimum distance of 3sn is required between the active surface and a metallic
surface in front of the device. (Fig. 1).
For SUS shielded types the following minimum distances are required to avoid performance change (see Fig.2 and table below):

Installation of non-shielded types in metal require the minimum


distances according to Fig. 3.

Shielded SUS Types


E2EL-2@-DS

3sn

2sn

Free zone
0,5 mm
d 3d

3sn

Fig.3: Non-shielded type

Fig.1: Shielded type (except SUS)


Freezone

3sn

Fig.2: Shielded SUS type

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.


To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. D06E-EN-Cat04-01

D-106

In the interest of product improvement, specifications are subject to change without notice.

Inductive Sensors

También podría gustarte