56-Calculo Recipientes A Presión
56-Calculo Recipientes A Presión
56-Calculo Recipientes A Presión
CLIENTE: PDVSA
INSTALACIN:
HOJA DE CLCULO - RECIPIENTES A PRESIN
SITIO: SERVICIO:
PROYECTO: DESCRIPCIN: SEPARADOR BIFASICO HORIZONTAL
No. HOJA DE DATOS: ROTULO (# TAG):
CARACTERSTICAS DE DISEO
CARCASA ----- CILNDRICA TEMPERATURA DE DISEO F 244.00
CLIENTE: PDVSA
INSTALACIN:
HOJA DE CLCULO - RECIPIENTES A PRESIN
SITIO: SERVICIO:
PROYECTO: DESCRIPCIN: SEPARADOR BIFASICO HORIZONTAL
No. HOJA DE DATOS: ROTULO (# TAG):
ESPESOR REQUERIDO
Pulg 0.3700 0.4531 0.3140 0.2598
(MNIMO DE TUBERA)
ESPESOR SELECCIONADO
Pulg 0.3780 0.5740 0.3833 0.3001
(MNIMO DE TUBERA)
ESPESOR REQUERIDO
Pulg 0.2598 0.2598 0.2598 0.2239
(MNIMO DE TUBERA)
ESPESOR SELECCIONADO
Pulg 0.3001 0.3001 0.3001 0.2695
(MNIMO DE TUBERA)
SCHEDULE DE TUBERA ----- SCH. 160 SCH. 160 SCH. 160 SCH. XXS
CLIENTE: PDVSA
INSTALACIN:
HOJA DE CLCULO - RECIPIENTES A PRESIN
SITIO: SERVICIO:
PROYECTO: DESCRIPCIN: SEPARADOR BIFASICO HORIZONTAL
No. HOJA DE DATOS: ROTULO (# TAG):
ESPESOR REQUERIDO
Pulg 0.2598 0.3140 0.3140 0.3324
(MNIMO DE TUBERA)
ESPESOR SELECCIONADO
Pulg 0.3001 0.3833 0.3833 0.3833
(MNIMO DE TUBERA)
SCHEDULE DE TUBERA ----- SCH. 160 SCH. 160 SCH. 160 SCH. 120
ESPESOR REQUERIDO
Pulg 0.3324 0.2414 0.4531
(MNIMO DE TUBERA)
ESPESOR SELECCIONADO
Pulg 0.3833 0.3133 0.4918
(MNIMO DE TUBERA)
CLIENTE: PDVSA
INSTALACIN:
HOJA DE CLCULO - RECIPIENTES A PRESIN
SITIO: SERVICIO:
PROYECTO: DESCRIPCIN: SEPARADOR BIFASICO HORIZONTAL
No. HOJA DE DATOS: ROTULO (# TAG):
d
b 0.375 0.000 0.000 ----------
b c 0.263 0.263 0.263 ----------
Re
d 0.263 0.263 0.263 ----------
CLIENTE: PDVSA
INSTALACIN:
HOJA DE CLCULO - RECIPIENTES A PRESIN
SITIO: SERVICIO:
PROYECTO: DESCRIPCIN: SEPARADOR BIFASICO HORIZONTAL
No. HOJA DE DATOS: ROTULO (# TAG):
d
b ---------- ---------- ---------- ----------
b c ---------- ---------- ---------- ----------
Re
d ---------- ---------- ---------- ----------
CLIENTE: PDVSA
INSTALACIN:
HOJA DE CLCULO - RECIPIENTES A PRESIN
SITIO: SERVICIO:
PROYECTO: DESCRIPCIN: SEPARADOR BIFASICO HORIZONTAL
No. HOJA DE DATOS: ROTULO (# TAG):
d
b ---------- 0.000 0.000 0.000
b c ---------- 0.263 0.263 0.263
Re
d ---------- 0.263 0.263 0.263
CLIENTE: PDVSA
INSTALACIN:
HOJA DE CLCULO - RECIPIENTES A PRESIN
SITIO: SERVICIO:
PROYECTO: DESCRIPCIN: SEPARADOR BIFASICO HORIZONTAL
No. HOJA DE DATOS: ROTULO (# TAG):
d
b 0.000 ---------- 0.000
b c 0.263 ---------- 0.263
Re
d 0.263 ---------- 0.263
ENTES A PRESIN
ASICO HORIZONTAL
IN
D1
CARCASA
SA-106-B
15000
2.000
0.125
0.2598
0.3001
SCH. 160
0.3430
2971.92
4898.60
1635.31
F1
CARCASA
SA-106-B
15000
0.750
0.125
0.2239
0.2695
SCH. XXS
0.3080
6075.70
11498.26
799.91
ENTES A PRESIN
ASICO HORIZONTAL
IN
G3
CARCASA
SA-106-B
15000
4.000
0.125
0.3324
0.3833
SCH. 120
0.4380
2209.62
3166.57
2199.47
ENTES A PRESIN
ASICO HORIZONTAL
D1
NO
1.313
0.845
0.343
0.000
----------
----------
SIN REFUERZO
----------
----------
----------
----------
----------
----------
NO SE REQUIERE
----------
----------
----------
----------
----------
----------
----------
----------
----------
----------
----------
----------
----------
ENTES A PRESIN
ASICO HORIZONTAL
NT.)
F1
NO
1.313
0.217
0.308
0.000
----------
----------
SIN REFUERZO
----------
----------
----------
----------
----------
----------
NO SE REQUIERE
----------
----------
----------
----------
----------
----------
----------
----------
----------
----------
----------
----------
----------
ENTES A PRESIN
ASICO HORIZONTAL
NT.)
G3
NO
1.313
1.812
0.438
0.000
0.375
0.000
4.462
0.234
0.363
----------
0.121
0.718
NO
SA-516-70
17500
0.375
4.000
0.375
0.000
0.263
0.263
0.234
0.479
----------
0.189
1.313
2.215
NO
ENTES A PRESIN
ASICO HORIZONTAL
NT.)
CLIENTE: PDVSA
INSTALACIN:
HOJA DE CLCULO - RECIPIENTES A PRESIN
SITIO: SERVICIO:
PROYECTO: DESCRIPCIN: SEPARADOR BIFASICO HORIZONTAL
No. HOJA DE DATOS: ROTULO (# TAG):
COEFICIENTE DEL SUELO ----- 1.2 VELOCIDAD DEL VIENTO mph 80.5
MOMENTO MXIMO EN LA
Lb.Pulg 6,015,248.91
BASE (M) ESFUERZO DEL RECIPIENTE Psi 5,146.99
MXIMO PERODO DE VIBRACIN PERMITIDO POR VIENTO: 2.21 seg POR SISMO: 0.78 seg
ENTES A PRESIN
ASICO HORIZONTAL
RTICALES
80.5
1,667.02
1.55
485.33
0.1579
0.00
5,146.99
0.4743
0.18 seg
0.78 seg
CLIENTE: PDVSA
HOJA DE CLCULO - RECIPIENTES A PRESIN
INSTALACIN:
SITIO: SERVICIO:
PROYECTO: DESCRIPCIN: SEPARADOR BIFASICO HORIZONTAL
No. HOJA DE DATOS: ROTULO (# TAG):
REA TRANSVERSAL
ESFUERZO DE CORTE Lb 2,321.94 FUERZA DEL VIENTO Lb 2,208.93
MOMENTO MXIMO EN LA PRESIN DEL VIENTO Psi 0.14
Lb.Pulg 152,812.59
BASE (M) ESFUERZO DEL RECIPIENTE Psi 130.76
MOMENTO EN EL PUNTO EN ESPESOR REQUERIDO
CONSIDERACIN (MT) Lb.Pulg 115,004.11 Pulg 0.1339
(INCLUYENDO CORROSIN)
ENTES A PRESIN
ASICO HORIZONTAL
ZONTALES
DO
tS
SA-516-70
17500
100.00
3
85.0
13,005.11
0.14
511.82
0.1597
2,208.93
0.14
130.76
0.1339
0.00
6,430.07
0.5613
0.21 seg
0.88 seg