FACULTAD DE INGENIERÍA
ESCUELA DE INGENIERÍA CIVIL
AUTORES
DIRECTOR
RESUMEN
PALABRAS CLAVE
ABSTRACT
This project shows the structural analysis of various sections of prefabricated and pre-
stressed concrete beams exposed to bending, shear and torsion. The beam sections
analyzed are: rectangular, rectangular hollow, T, I, and double T. In the bending analysis,
the cables used are straight prestressed of high strength, at a certain eccentricity; In the
torsional analysis we use two parabolic paths with opposite concavities and an established
separation between the parabolas, each parabola will sustain one or more pre-stressing
cables necessary for an acceptable pre-tensioned force such that it will generate a resistant
torque. And for the shear analysis we use the sections that do not require reinforcing steel
by cutting, so that don´t transverse nor longitudinal steel is required. Thus the only steel
that is required in the analysis are the pre-stressing cables.
For the analysis of the different sections we work in technical documentation programs with
numeric and symbolic computational presentations, PTC Mathcad Prime. These analyzes
of parabolic path for torsion or bending are not common in our environment so these paths
need to be deeply investigated either in post-tensioned or prestressed, so that the use of
this method becomes convenient and practical.
KEYWORDS
Contenido
CAPITULO I: INTRODUCCION ............................................................................................ 1
1.1 Introducción y antecedentes........................................................................................ 1
1.2 Objetivo general .......................................................................................................... 1
1.3 Objetivos específicos .................................................................................................. 2
1.4 Justificación ................................................................................................................. 2
CAPITULO II: MARCO TEORICO ........................................................................................ 3
2.1 Hormigón pretensado .................................................................................................. 3
2.1.1 Conceptos generales ............................................................................................ 3
2.1.2 Procedimiento de pretensado ............................................................................... 3
2.1.3 Materiales del hormigón pretensado ..................................................................... 3
2.1.3.1 Hormigón de pretensado ................................................................................ 3
2.1.3.1.1 Propiedades del hormigón pretensado ..................................................... 4
2.1.3.2 Acero de pretensado....................................................................................... 5
2.1.3.2.1 Propiedades del acero de pretensado ...................................................... 7
2.2 Pérdidas en el hormigón pretensado ........................................................................... 9
2.2.1 Generalidades ....................................................................................................... 9
2.2.2 Procedimiento para calcular las pérdidas ............................................................10
2.2.2.1 Acortamiento elástico instantáneo del hormigón ...........................................10
2.2.2.2 Retracción del hormigón ................................................................................12
2.2.2.3 Fluencia plástica del hormigón ......................................................................13
2.2.2.4 Corrimiento y ajuste de cuñas .......................................................................13
2.2.2.5 Relajación del acero ......................................................................................14
2.2.2.6 Recomendaciones para reducir las pérdidas .................................................15
2.3 Cargas ........................................................................................................................15
2.3.1 Generalidades ......................................................................................................15
2.3.2 Cargas muertas....................................................................................................16
2.3.3 Cargas vivas ........................................................................................................16
2.3.4 Cargas ambientales .............................................................................................17
2.4 Análisis a flexión .........................................................................................................17
2.4.1 Generalidades ......................................................................................................17
2.5 Análisis a cortante ......................................................................................................20
2.5.1 Conceptos generales ...........................................................................................20
Índice de gráficos
Índice de tablas
Simbología
Momento estático de la sección sobre la altura y1, hasta la fibra extrema respecto al
E.N.
Momento Torsor actuante ultimo
Momento Torsor resistente nominal
Momento flector ultimo
Relación entre módulos de elasticidad del acero y hormigón
Relación entre módulos de elasticidad inicial del acero y hormigón
Fuerza de tensado inicial
Radio de giro de la sección
: Superficie
: Espaciamiento del acero transversal por cortante
Módulo resistente de la sección, con respecto a la fibra superior
Módulo resistente de la sección, con respecto a la fibra inferior
t : tiempo en general
: Fuerza Cortante
Fuerza Cortante que actúa en la sección
Resistencia nominal a cortante de una sección de hormigón
Resistencia nominal a cortante de una sección
Resistencia nominal a corte de una sección debida al refuerzo de cortante
Esfuerzo cortante máximo
w: carga uniformemente repartida
Carga por peso propio
Densidad del hormigón
Ancho y alto donde fluye el corte de flujo
: Carga viva uniformemente repartida
Peso específico del hormigón
Factor que depende de la resistencia del hormigón
Elongación o deformación total, contraflecha o camber
Deformación unitaria en general
Deformación unitaria del acero de preesfuerzo
Deformación unitaria máxima de la fibra superior
Flecha o contraflecha de un elemento
Pérdida total en lo torones expresada en kg/cm2
Pérdida por corrimiento y ajuste de cuñas
Pérdida por relajación del acero de preesfuerzo
Pérdida por el acortamiento elástico instantáneo del hormigón
Pérdida por retracción del hormigón
Pérdida por fluencia plástica del hormigón
Factor debido a las propiedades mecánicas del hormigón
Factor que depende de las propiedades del acero de preesfuerzo
Cuantía de acero pasivo
Cuantía de acero de preesfuerzo
Factor de reducción de resistencia
u : Corrimiento de cuñas
Índice de refuerzo a tracción
Índice de refuerzo a compresión
Índice de acero de preesfuerzo
DEDICATORIAS
Este proyecto dedico a mis padres Nancy Peralta y Tarquino Valverde y familia que
apoyaron para hacer posible seguir y culminar esta carrera, siendo un ejemplo de
superación y esfuerzo, inculcando principios y valores que me permitieron finalizar una de
mis metas.
Diego.
Este proyecto dedico a mis padres Jorge Ullaguari y Beatriz Guamán y demás familiares y
amigos compañeros cercanos, que apoyaron para hacer posible seguir y culminar esta
carrera, siendo un ejemplo de superación y esfuerzo, inculcando principios y valores que
me permitieron finalizar una de mis metas.
Klever.
AGRADECIMIENTOS
CAPITULO I: INTRODUCCION
1.1 Introducción y antecedentes
En la actualidad, la expansión urbana y el desarrollo de las ciudades van
innovando sus sistemas constructivos permitiendo así la integración de nuevos
métodos, como el uso de elementos prefabricados sometidos a preesfuerzo. La
inclusión de este sistema constructivo permite obtener estructuras más
económicas y livianas, de forma más práctica que realizarlas con los métodos
tradicionales.
1.4 Justificación
Dada la creciente aplicación de este sistema constructivo y aplicación a
esfuerzos no solo bidireccionales si no espaciales, se ve la necesidad de
recurrir a nuevos análisis, que permita obtener trazados que resistan los
esfuerzos aplicados a esas secciones.
Resistencia a la tracción:
Es un poco más complicada y se la obtiene en laboratorio mediante el ensayo
brasileño, midiendo la tracción en flexión pura para obtener el modulo ruptura
del hormigón fr, con probetas cuadradas de 15cm de lado y una luz de 45.7cm,
cargándolas en los tercios centrales para obtener una tramo de momento
constante.
Resistencia al corte:
Realizarlo es aún un poco más complicado que los anteriores, ya que es difícil
hacer ensayos de corte puro sin que haya presencia de otro tipo de esfuerzos;
para el caso de elementos no preesforzados, el ACI especifica una valor de
cortante dador por √ en kg/cm2, para elementos sometidos únicamente
a cortante y flexión. En el caso de elementos preesforzados que tienen una
fuerza activa mínima del 40% de la resistencia a la tracción del refuerzo de
flexión, se puede tomar el valor dado por √ , donde Vu: es la
fuerza cortante mayorada, dp: distancia desde la fibra extrema en compresión
al centroide del acero preesforzado, Mu: momento mayorado de la sección.
Este valor debe ser mayor a √ y menor que √ , además de otras
consideraciones adicionales que se deberán revisar en el ACI. Como se puede
observar el pretensado aumenta la resistencia al corte .En la práctica no se
encuentra elementos sometidos a corte puro, ya que siempre están asociados
con flexión, compresión y torsión.
Rigidez:
La rigidez es la capacidad que tiene el cuerpo para resistir deformaciones
producidas por la acción de fuerzas externas, de manera general se puede
expresar como una relación entre la fuerza y la deformación. Para el hormigón
se utiliza el módulo de elasticidad Ec, entendido como rigidez del material, ya
que es un parámetro de mucha importancia en los cálculos. Según el ACI el
módulo de Elasticidad se puede tomar como √ en kg/cm2,
donde Wc: es la densidad del hormigón en kg/m3, la cual está entre 1440 y
2480 kg/m3, pero para hormigones de densidad normal Ec se puede tomar
como √ .
grado 250ksi. Según la norma ASTM A416. El módulo de elasticidad varía cada
cable y debe ser proporcionado por el fabricante.
Ilustración 1: Curva esfuerzo deformación de los aceros usado en hormigón armado y pretensado
(Carrasco Castro 2010)
Ilustración 2: Cable toron estándar de 7 hilos para pretensar (Carrasco Castro 2010)
Ilustración 3: Comportamiento gráfico de las pérdidas por relajación (Carrasco Castro 2010)
Longitud de desarrollo
Longitud de desarrollo o longitud de adherencia, es la longitud de acero que
necesariamente debe estar empotrada en el hormigón para que esta no se
desprenda y llegue al esfuerzo de fluencia (ver Ilustración 4), esto indica el
grado de adherencia entre el acero y el hormigón; pues, casi todo el esfuerzo
de compresión en el hormigón se desarrolla por la adherencia.
( ) ( ) Donde:
Longitud de desarrollo en cm
Ilustración 5: Longitud de desarrollo para cables de pretensar según el ACI (Carrasco Castro 2010)
2.2.1 Generalidades
La fuerza de pretensado puede disminuir instantáneamente y con el paso del
tiempo, quitándole capacidad al elemento. Se pueden calcularlas hasta un
Diego Javier Valverde Peralta
Klever Rolando Ullaguari Guaman
9
Universidad de Cuenca
Existen dos tipos de pérdidas: las instantáneas y las diferidas en el tiempo (ver
Tabla 2).
Tabla 2: Pérdidas por pretensado
Hormigón Acero
Instantáneas -Acortamiento elástico -Corrimiento y ajuste
instantáneo de las cuñas de
pretensar
Diferidas en el -Retracción del -Relajación del acero
tiempo hormigón
-Fluencia plástica del
hormigón
acorta; análogamente sucede con el acero (ver Ilustración 6), el cual pierde
esfuerzo. La deformación del acero viene dada por la fórmula de la ley de
Hooke.
Y se expresa como:
Ilustración 6: Acortamiento Elástico del hormigón debido a la fuerza de pretensar 𝑃𝑖 (Carrasco Castro 2010)
( )
Y con este valor se obtiene las pérdidas del acero de pretensar, que viene dado
por la siguiente expresión, donde es la relación de módulos de acero y
hormigón, el último se obtiene de √ , donde es la resistencia al
momento de cortar los cables.
( )
En donde se expresa:
Y en kg/cm2
V en cm3
S en cm2
HR en %
Es necesario recalcar que todas las formulas con las que se puede estimar la
retracción son obtenidas de forma experimental, así pues en el PCI existen
más fórmulas para calcular la retracción a distintas edades del hormigón.
Dónde:
Si llamamos ”u” al corrimiento total, L a la longitud total del cable entre anclajes
se puede calcular la deformación unitaria (cm/cm) que se produce como:
Ilustración 7: Pérdidas por corrimiento y ajuste de cuñas, con relación a la longitud de la cama de
pretensado (Carrasco Castro 2010)
A pesar de que los fabricantes dan valores de relajación existe una forma de
estimarlo con la siguiente expresión:
( )( )
( )
2.3 Cargas
2.3.1 Generalidades
Las estructuras y sus elementos deben diseñarse para resistir diferentes tipos
de cargas aplicadas según lo especificado en las normas de diseño, deben
considerarse las cargas que se pueden presentar con una probabilidad de
Las cargas de impacto son las que cusan vibración en las estructuras; estas
cargas causan mayores fuerzas que las que se presentarían si las cargas se
aplicaran gradualmente; estas constituyen la diferencia entre las cargas
realmente generadas y las consideradas como muertas.
Las cargas de hielo y nieve se presentan en los países más fríos; en algunas
ocasiones son de considerable magnitud y rigen el diseño. Las cargas de lluvia
pueden ser muy perjudiciales en techos horizontales, la carga hace que el
techo se flexione en forma de plato, y a su vez, cause más deflexiones. La
carga de viento es una de las que ha causado más fallas estructurales; la
magnitud y duración de las cargas de viento varían de acuerdo a la ubicación
geográfica, la altura de las estructuras, los tipos de suelo alrededor,
construcciones cercanas y la fuerza del viento en sí misma.
2.4.1 Generalidades
La mayoría de los elementos están sometidos a esfuerzos de flexión, por lo
cual es indispensable tomar en cuenta estos esfuerzos, ya que en muchos
casos domina en el diseño. En vigas y otros elementos sometidos
principalmente a flexión, la fuerza axial es muy pequeña que se la puede
considerar despreciable para el diseño. Posterior al diseño de flexión se debe
verificar por cortante y torsión, para comprobar las deflexiones y el control de
fisuras a ver si son o no de importancia.
En estado elástico, los esfuerzos en las fibras extrema superior e inferior están
dadas por las siguientes expresiones de flexión básica en estado elástico:
( )
( )
La AASHTO específica que no debe forrarse más del 25% del total de todos los
cables, de modo que ninguna fila del número de cables forrados deberá
superar el 40%.
: Ancho de la sección
( )
Ilustración 11: Distribución de los esfuerzos cortantes en una sección rectangular (Carrasco Castro 2010)
Por lo tanto:
Ilustración 14: Comportamiento de tubo de pared delgada bajo torsión (Nilson 1999)
El esfuerzo cortante unitario que actúa dentro de las paredes del tubo es
expresa como:
√ 2
√ , lb-pulg
2.7 Deflexiones
Ilustración 15: Contraflecha inicial o Camber en una viga pretensada (Carrasco Castro 2010)
Tabla 4: Tolerancias del camber diferencial entre dos elementos según el PCI
Para calcular las deflexiones, hay que tener como dato el módulo de elasticidad
del elemento y el momento de Inercia , para secciones tipo U donde el
esfuerzo máximo a tracción no supera el límite √ puede usarse la sección
total del elemento para obtener el momento de inercia, ya que el elemento no
está fisurado y trabaja toda su sección a los esfuerzo de flexión. En cambio en
elementos tipo C y T; para calcular la inercia se debe tomar la sección
agrietada. Para estimar las deflexiones a largo plazo, influyen los efectos de la
fluencia plástica, retracción del hormigón, relajación del acero lo cuales hacen
que varié .
( )
( * +)
( ) ( )
Ilustración 16: Elemento bajo flexión con acero adicional de tracción (Carrasco Castro 2010)
( ) ( ) ( )
Ilustración 17: Elemento bajo flexión con acero adicional en tracción y compresión (Carrasco Castro 2010)
Para garantizar que una sección no tenga fallas frágiles, es decir, no contenga
muy poco acero, el ACI recomienda una cantidad mínima de acero, de modo
que: ØMn≥1.2Mcr, siendo Mcr el momento de fisuración. Esta comprobación se
realiza en secciones con cargas uniformemente repartidas, donde el máximo
momento se produce en el centro de la luz, con esto se advierte la falla
presentando una deformación notoria, o de lo contrario llegaría a fisurarse y a
fallar sin previo aviso.
( ) √
[ ( )]
De igual modo para no obtener una falla frágil por compresión en el hormigón,
debido a que haya demasiado acero, el ACI limita la cantidad máxima, de
manera que indique que hay fisuraciones, deformaciones previas a la falla (ver
Ilustración 18).
Ilustración 18: Deformaciones unitarias para falla por tracción (Carrasco Castro 2010)
Para las secciones controladas por tracción de 0.005 para el acero extremo, el
ACI recomienda usar un wp =0.32β1, en donde las secciones son rectangulares
y tienen solo acero de preesfuerzo.
Se puede calcular el cortante último a una distancia h/2, medido desde la cara
del apoyo, donde h es la altura del elemento, siempre y cuando se cumpla lo
siguiente:
Ilustración 19: Sección transversal efectiva para corte (Carrasco Castro 2010)
( √ )
√ √
Pero
Dónde:
Ilustración 20: Perspectiva de la viga y los esfuerzos generados debido a una fuerza excéntrica
Ilustración 21: Perspectiva del trazado parabólico con medias parábolas y parábolas enteras, donde P es
la fuerza de pretensado der los cables
q = n*Cos(α) + t*Sen(α)
h = fn*Sen(α) + ft*Cos(α)
m = h*(Ycdg - Yp)
Ilustración 23: Fuerzas equivalentes de pretensado proyectadas en x,y referidas al centro de gravedad de la
sección
Dónde:
α: Ángulo que forma el cable de pretensado respecto de la horizontal
: Distancia de la fibra de pretensado respecto una fibra de referencia
cualquiera
: Distancia del centro de gravedad de la sección a una fibra de referencia
arbitraria
En sección 1: En Sección 2:
De modo que:
Equilibrio de momentos:
( )
Esto indica que como es el momento producido por h, que como se acabó de
demostrar es 0, así pues de forma simplificada las fuerzas equivalentes de
pretensado se reducen a:
Ilustración 25: Planteamiento del trazado para realizar el análisis con parábolas completas
Entonces:
Convención de signos utilizada; positivo: giro a favor de las agujas del reloj,
negativo: giro anti-horario
Dónde:
Dónde:
Ilustración 27: Planteamiento del trazado para realizar el análisis con medias parábolas
Dónde:
Donde se despeja P:
Cabe destacar también que una sección rectangular b,h; los trazados no solo
se pueden plantear en planos horizontales como se ha hecho hasta ahora, sino
que también se los puede obtener en planos verticales de la sección; es decir,
en las caras frontal y posterior paralelas a la altura h, de modo que, planteando
el mismo sistema de análisis anterior e imponiendo los mismos recubrimientos;
el análisis tanto del trazado como de su fuerza P resulta en las siguientes
expresiones, siendo las mismas a las antes obtenidas pero con un cambio en
las constantes de recubrimiento:
Tabla 7: Multiplicadores dador por el ACI para el Camber y deflexiones a largo plazo (Carrasco Castro
2010)
Las secciones analizadas deben resistir como mínimo las solicitaciones de este
ejemplo, para ello se realizó iteraciones de: la geometría de la sección, la
cantidad de refuerzo que debe colocarse y del peralte efectivo del acero de
preesfuerzo utilizado; de esta manera se obtuvo la siguiente Tabla 9 de
resultados para las 5 secciones:
cm cm2
Seccion Ancho Alto Alma b Ala t dp rec A
1) Rectangular 50 65 58.5 5.865 3250
2) Rect-Hueca 65 65 58.5 5.865 3425
Parte Hueca 20 40
3) Tee 100 75 35 15 68.3 6.065 3600
4) Doble Tee 160 65 22.5 15 58.2 6.165 4650
5) I 70 75 35 15 68.5 5.865 3675
BIBLIOGRAFÍA
(American Concrete Intitute), ACI 318S-08. Requisitos y Reglamentos para
Concreto Estructural. 2008.
b ≔ 65 : ancho de sección
h ≔ 65 : altura de la seción
L ≔ 12 : Logitud de la viga considerada
‾‾‾‾‾‾‾
Ec ≔ 15100 ⋅ f'c ⋅ ――= 302000 ――
2 2
‾‾‾‾‾‾‾‾
Eci ≔ 15100 ⋅ f'ci ⋅ ――= 282495.1 ――
2 2
2
∴ A ≔ 1.387 :Area del acero de 0.6 pulgadas (ver tabla 1 de tipos de cables )
2
Ap ≔ #cables ⋅ A = 8.322 :Area total de acero de preesfuerzo
fpi
ε ≔ ― = 0.007
Ep
⎛ (b − 2 ⋅ recp) ⎞
Sp ≔ ⎜#cables > 1 , ――――, 0 ⎟⎠
⎝ #cables − 1
65
58.5
52
45.5
39
32.5
26
19.5
13
6.5
0
0 6.5 13 19.5 26 32.5 39 45.5 52 58.5 65
‐Debido a la fuerza del gato de preesforazdo :
Y el máximo establecido
pero no mayor que el mínimo entre: 0.80 ⋅ fpu = 15200 ―― por el fabricante o por
2
los diposi vos de anclaje
∴ con = “cumple”
‐Justo después de la trasferencia del esfuerzo de preesfuerzo:
∴ con1 = “cumple”
En estado elás co, los esfuerzos en las fibras extrema superior e inferior de la sección
( , ), están dadas por las siguientes expresiones de flexión básica en estado elás co:
2
L
MD ≔ WD ⋅ ―― = 1479600 ⋅ :Momento flector máximo por peso propio
8
Ct ≔ 0.5 ⋅ h = 32.5 :Distancia desde la L.N. a la fibra superior
Ix 3
St ≔ ― = 42488.782 :Módulo de la sección respecto a la fibra superior
Ct
Ix 3
Sb ≔ ― = 42488.782 :Módulo de la sección respecto a la fibra inferior
Cb
r = 20.079 :Radio de giro de la sección
Calculando los esfuerzos en el centro de la viga, que es donde actua el Momento Maximo
por peso propio:
−Pi ⎛ e ⋅ C t ⎞ MD
ft ≔ ―― ⋅ ⎜1 − ―― − ――= 2.45 ―― :Esfuerzo en fibra superior (+) Tracción
2 ⎟ 2
Ac ⎝ r ⎠ St
‾‾‾‾‾‾‾‾
Esfuerzo maximo en tracción ( no en extremos) 0.80 ⋅ f'ci ⋅ ――= 14.967 ――
2 2
= “cumple”
−Pi ⎛ e ⋅ Cb ⎞ MD
fb ≔ ―― ⋅ ⎜1 + ――⎟ + ―― = −70.5 ―― :Esfuerzo en fibra inferior (-) Compresión
2 2
Ac ⎝ r ⎠ Sb
= “cumple”
Calculando los esfuerzos en los extremos de la viga , donde el peso propio no actua:
−Pi ⎛ e ⋅ Ct ⎞
ft1 ≔ ―― ⋅ ⎜1 − ―― = 37.28 ―― :Esfuerzo en fibra superior (+) Tracción
2 ⎟ 2
Ac ⎝ r ⎠
‾‾‾‾‾‾‾‾
Esfuerzo maximo en tracción ( en los extremos) 1.60 ⋅ f'ci ⋅ ――= 29.933 ――
2 2
= “no cumple”
−Pi ⎛ e ⋅ Cb ⎞
fb1 ≔ ―― ⋅ ⎜1 + ―― = −105.3 ―― :Esfuerzo en fibra inferior (-) Compresión
2 ⎟ 2
Ac ⎝ r ⎠
= “cumple”
Graficos de Esfuerzos iniciales al cortar los cables, en la fibra superior e inferior ‐
Grafico de Esfuerzos en la mitad de la viga
65
58.5
52
45.5
39
32.5
26
esfuerzos_mitad ( )
19.5
13
6.5
0
-72 -64 -56 -48 -40 -32 -24 -16 -8 0 8
⎛ ⎞
esf_en_x ⎜――
2 ⎟
⎝ ⎠
Grafico de Esfuerzos en los extremos de la viga
65
58.5
52
45.5
39
32.5
26
esf_extremos ( )
19.5
13
6.5
0
-120-105 -90 -75 -60 -45 -30 -15 0 15 30 45
⎛ ⎞
esf2_en_x ⎜――
2 ⎟
⎝ ⎠
Mu = 73000 ⋅ :MOMENTO FLECTOR EXTERIOR ACTUANTE SOBRE A VIGA
Fy ≔ 4200 ―― :Esfuerzo de fluencia de acero normal
2
fps Se puede calcular con la siguiente fórmula siempre y cuando el esfuerzo efectivo de trabajo fpe
luego de que se den las pérdidas, no sea menor a 0.50fpu, es decir el 50% del esfuerzo último
especificado (19000kg/cm2) para aceros de grado 270ksi.
fpy
―― = 0.901
fpu
f'c
β1 ≔ 1.05 − 0.05 ⋅ ―――= 0.76 :Coeficiente para calcular la profundidad del
70 ―― bloque de compresion, en funcion de f'c
2
*En este caso no te ul liza acero adicional ni a tensión ni a compresión:
∴ ρ' ≔ 0 :Cuan a de acero a compresión
∴ d' ≔ 0 :Peralte de acero a compresión
∴ ρ≔0 :Cuan a de acero a tensión
∴ d≔0 :Peralte de acero a tensión
Fy
w ≔ ρ ⋅ ―― =0
f'c
Fy ⎛ fpu d ⎞
w' ≔ ρ' ⋅ ―― =0 ∴ cond ≔ ⎜ρp ⋅ ―― + ―⋅ (w − w')⎟ = 0.104
f'c ⎝ f'c dp ⎠
∴ val ≔ (w' > 0 ∧ cond ≤ 0.17 , 0.17 , cond) = 0.104
*y tambien d' no debe ser mayor a 0.15 dp , de no cumplirse
esto, w' se toma = 0 d' ≔ 0 0.15 ⋅ dp = 8.775
∴ = “cumple”
⎛ γp ⎞
∴ fps ≔ fpu ⋅ ⎜1 − ― ⋅ (val)⎟ = 18276.4 ――
2
⎝ β1 ⎠
Ap ⋅ fps
a ≔ ―――― = 6.88
0.85 ⋅ f'c ⋅ b
∴ obs = “a no sobrepasa la parte hueca”
⎛ a⎞
∴ Mn ≔ Ap ⋅ fps ⋅ ⎜dp − ―
⎝ 2 ⎟⎠
∴ ϕMn ≔ 0.9 ⋅ Mn = 75368 ⋅ : Cuando solo hay cable de pretensado
Mu
Demand_capacidad ≔ ――⋅ 100 = 97 : % al que trabaja la sección
ϕMn
3) FLEXIÓN SECCIÓN T
3.1-.introduccion de datos por el usuario
Geometira de la sección
2
Ac ≔ tf ⋅ b + tw ⋅ ⎛⎝h − tf⎞⎠ = 3600
3 3
k1 2 tf 2 4
Ix ≔ tw ⋅ ―― + ⎛⎝tw ⋅ k1⎞⎠ ⋅ (0.5 ⋅ k1 − ŷ) + b ⋅ ―― + ⎛⎝b ⋅ tf⎞⎠ ⋅ (k2 − ŷ) = 1888593.75
12 12
‾‾‾
Ix
r≔ ― = 22.9
Ac
‾‾‾‾‾‾‾
Ec ≔ 15100 ⋅ f'c ⋅ ――= 302000 ――
2 2
‾‾‾‾‾‾‾‾
Eci ≔ 15100 ⋅ f'ci ⋅ ――= 282495.1 ――
2 2
2
∴ A ≔ 1.387 :Area del acero de 0.6 pulgadas (ver tabla 1 de tipos de cables )
2
Ap ≔ #cables ⋅ A = 6.935 :Area total de acero de preesfuerzo
fpi
ε ≔ ― = 0.007
Ep
ŷ = 45.63
⎛ ⎛⎝tw − 2 ⋅ recp⎞⎠ ⎞
Sp ≔ ⎜#cables > 1 , ――――― ,0 ⎟
⎝ #cables − 1 ⎠
75
67.5
60
52.5
45
37.5
30
22.5
15
7.5
0
-50 -40 -30 -20 -10 0 10 20 30 40 50 60 70 80
‐Debido a la fuerza del gato de preesforazdo :
Y el máximo establecido
pero no mayor que el mínimo entre: 0.80 ⋅ fpu = 15200 ―― por el fabricante o por
2
los diposi vos de anclaje
∴ con = “cumple”
‐Justo después de la trasferencia del esfuerzo de preesfuerzo:
∴ con1 = “cumple”
En estado elás co, los esfuerzos en las fibras extrema superior e inferior de la sección
( , ), están dadas por las siguientes expresiones de flexión básica en estado elás co:
2
L
MD ≔ WD ⋅ ―― = 1555200 ⋅ :Momento flector máximo por peso propio
8
Ct ≔ h − ŷ = 29.375 :Distancia desde la L.N. a la fibra superior
Ix 3
St ≔ ― = 64292.553 :Módulo de la sección respecto a la fibra superior
Ct
Ix 3
Sb ≔ ― = 41393.836 :Módulo de la sección respecto a la fibra inferior
Cb
r = 22.904 :Radio de giro de la sección
Calculando los esfuerzos en el centro de la viga, que es donde actua el Momento Maximo
por peso propio:
−Pi ⎛ e ⋅ C t ⎞ MD
ft ≔ ―― ⋅ ⎜1 − ―― − ――= 7.74 ―― :Esfuerzo en fibra superior (+) Tracción
2 ⎟ 2
Ac ⎝ r ⎠ St
‾‾‾‾‾‾‾‾
Esfuerzo maximo en tracción ( no en extremos) 0.80 ⋅ f'ci ⋅ ――= 14.967 ――
2 2
= “cumple”
−Pi ⎛ e ⋅ Cb ⎞ MD
fb ≔ ―― ⋅ ⎜1 + ――⎟ + ―― = −80.9 ―― :Esfuerzo en fibra inferior (-) Compresión
2 2
Ac ⎝ r ⎠ Sb
= “cumple”
Calculando los esfuerzos en los extremos de la viga , donde el peso propio no actua:
−Pi ⎛ e ⋅ Ct ⎞
ft1 ≔ ―― ⋅ ⎜1 − ―― = 31.93 ―― :Esfuerzo en fibra superior (+) Tracción
2 ⎟ 2
Ac ⎝ r ⎠
‾‾‾‾‾‾‾‾
Esfuerzo maximo en tracción ( en los extremos) 1.60 ⋅ f'ci ⋅ ――= 29.933 ――
2 2
= “no cumple”
−Pi ⎛ e ⋅ Cb ⎞
fb1 ≔ ―― ⋅ ⎜1 + ――⎟ = −118.4 ―― :Esfuerzo en fibra inferior (-) Compresión
2 2
Ac ⎝ r ⎠
= “cumple”
Graficos de Esfuerzos iniciales al cortar los cables, en la fibra superior e inferior ‐
Grafico de Esfuerzos en la mitad de la viga
75
67.5
60
52.5
45
37.5
30
esfuerzos_mitad ( )
22.5
15
7.5
0
-81 -72 -63 -54 -45 -36 -27 -18 -9 0 9
⎛ ⎞
esf_en_x ⎜――
2 ⎟
⎝ ⎠
Grafico de Esfuerzos en los extremos de la viga
75
67.5
60
52.5
45
37.5
30
esf_extremos ( )
22.5
15
7.5
0
-120-105 -90 -75 -60 -45 -30 -15 0 15 30 45
⎛ ⎞
esf2_en_x ⎜――
2 ⎟
⎝ ⎠
Mu = 73000 ⋅ :MOMENTO FLECTOR EXTERIOR ACTUANTE SOBRE A VIGA
Fy ≔ 4200 ―― :Esfuerzo de fluencia de acero normal
2
fps Se puede calcular con la siguiente fórmula siempre y cuando el esfuerzo efectivo de trabajo fpe
luego de que se den las pérdidas, no sea menor a 0.50fpu, es decir el 50% del esfuerzo último
especificado (19000kg/cm2) para aceros de grado 270ksi.
fpy
―― = 0.901
fpu
dp ≔ h − ŷ + e = 68.38 :distanncia de la fibra superior al centroide del
cable
γp = 0.55 :usualmente para barras de
pretensar
f'c
β1 ≔ 1.05 − 0.05 ⋅ ―――= 0.76 :Coeficiente para calcular la profundidad del
70 ―― bloque de compresion, en funcion de f'c
2
*En este caso no te ul liza acero adicional ni a tensión ni a compresión:
∴ ρ' ≔ 0 :Cuan a de acero a compresión
∴ d' ≔ 0 :Peralte de acero a compresión
∴ ρ≔0 :Cuan a de acero a tensión
∴ d≔0 :Peralte de acero a tensión
Fy
w ≔ ρ ⋅ ―― =0
f'c
Fy ⎛ fpu d ⎞
w' ≔ ρ' ⋅ ―― =0 ∴ cond ≔ ⎜ρp ⋅ ―― + ―⋅ (w − w')⎟ = 0.048
f'c ⎝ f'c dp ⎠
∴ val ≔ (w' > 0 ∧ cond ≤ 0.17 , 0.17 , cond) = 0.048
*y tambien d' no debe ser mayor a 0.15 dp , de no cumplirse
esto, w' se toma = 0 d' ≔ 0 0.15 ⋅ dp = 10.256
∴ = “cumple”
⎛ γp ⎞
∴ fps ≔ fpu ⋅ ⎜1 − ― ⋅ (val)⎟ = 18341.3 ――
2
⎝ β1 ⎠
Ap ⋅ fps
a ≔ ―――― = 3.74
0.85 ⋅ f'c ⋅ b
⎛ a⎞
∴ Mn ≔ Ap ⋅ fps ⋅ ⎜dp − ―
⎝ 2 ⎟⎠
∴ ϕMn ≔ 0.9 ⋅ Mn = 76132 ⋅ : Cuando solo hay cable de pretensado
Mu
Demand_capacidad ≔ ――⋅ 100 = 96 : % al que trabaja la sección
ϕMn
2
Ac ≔ tf ⋅ b + 2 ⋅ tw ⋅ ⎛⎝h − tf⎞⎠ = 4650
3 3
⎛ k1 ⎞ 2 tf 2 4
Ix ≔ 2 ⋅ ⎜tw ⋅ ―― ⎟ + 2 ⋅ ⎛⎝tw ⋅ k1⎞⎠ ⋅ (0.5 ⋅ k1 − ŷ) + b ⋅ ―― + ⎛⎝b ⋅ tf⎞⎠ ⋅ (k2 − ŷ) = 1740362.9
⎝ 12 ⎠ 12
‾‾‾
Ix
r≔ ― = 19.3
Ac
‾‾‾‾‾‾‾
Ec ≔ 15100 ⋅ f'c ⋅ ――= 302000 ――
2 2
‾‾‾‾‾‾‾‾
Eci ≔ 15100 ⋅ f'ci ⋅ ――= 282495.1 ――
2 2
2
∴ A ≔ 1.387 :Area del acero de 0.6 pulgadas (ver tabla 1 de tipos de cables )
"El numero de caables debe ser par para que se distribuya uniformemente en las 2 almas"
2
Ap ≔ #cables ⋅ A = 8.322 :Area total de acero de preesfuerzo
fpi
ε≔― = 0.007
Ep
ŷ = 41.774
⎛ ⎛⎝tw − 2 ⋅ recp⎞⎠ ⎞
Sp ≔ ⎜#cables > 1 , ―――――― ,0 ⎟
⎝ 0.5 ⋅ #cables − 1 ⎠
80
72
64
56
48
40
32
24
16
0
-90 -75 -60 -45 -30 -15 0 15 30 45 60 75 90
‐Debido a la fuerza del gato de preesforazdo :
Y el máximo establecido por
pero no mayor que el mínimo entre: 0.80 ⋅ fpu = 15200 ―― el fabricante o por los
2
diposi vos de anclaje
∴ con = “cumple”
‐Justo después de la trasferencia del esfuerzo de preesfuerzo:
∴ con1 = “cumple”
En estado elás co, los esfuerzos en las fibras extrema superior e inferior de la sección
( , ), están dadas por las siguientes expresiones de flexión básica en estado elás co:
2
L
MD ≔ WD ⋅ ―― = 2008800 ⋅ :Momento flector máximo por peso propio
8
Ct ≔ h − ŷ = 23.226 :Distancia desde la L.N. a la fibra superior
Ix 3
St ≔ ―= 74932.292 :Módulo de la sección respecto a la fibra superior
Ct
Ix 3
Sb ≔ ― = 41661.197 :Módulo de la sección respecto a la fibra inferior
Cb
r = 19.346 :Radio de giro de la sección
Calculando los esfuerzos en el centro de la viga, que es donde actua el Momento Maximo
por peso propio:
−Pi ⎛ e ⋅ C t ⎞ MD
ft ≔ ―― ⋅ ⎜1 − ―― − ――= 2.56 ―― :Esfuerzo en fibra superior (+) Tracción
2 ⎟ 2
Ac ⎝ r ⎠ St
‾‾‾‾‾‾‾‾
Esfuerzo maximo en tracción ( no en extremos) 0.80 ⋅ f'ci ⋅ ――= 14.967 ――
2 2
= “cumple”
−Pi ⎛ e ⋅ Cb ⎞ MD
fb ≔ ―― ⋅ ⎜1 + ―― + ―― = −74.7 ―― :Esfuerzo en fibra inferior (-) Compresión
2 ⎟ 2
Ac ⎝ r ⎠ S b
= “cumple”
Calculando los esfuerzos en los extremos de la viga , donde el peso propio no actua:
−Pi ⎛ e ⋅ Ct ⎞
ft1 ≔ ―― ⋅ ⎜1 − ―― = 29.36 ―― :Esfuerzo en fibra superior (+) Tracción
2 ⎟ 2
Ac ⎝ r ⎠
‾‾‾‾‾‾‾‾
Esfuerzo maximo en tracción ( en los extremos) 1.60 ⋅ f'ci ⋅ ――= 29.933 ――
2 2
= “cumple”
−Pi ⎛ e ⋅ Cb ⎞
fb1 ≔ ―― ⋅ ⎜1 + ―― = −122.9 ―― :Esfuerzo en fibra inferior (-) Compresión
2 ⎟ 2
Ac ⎝ r ⎠
= “cumple”
Graficos de Esfuerzos iniciales al cortar los cables, en la fibra superior e inferior ‐
Grafico de Esfuerzos en la mitad de la viga
65
58.5
52
45.5
39
32.5
26
esfuerzos_mitad ( )
19.5
13
6.5
0
-76.5 -68 -59.5 -51 -42.5 -34 -25.5 -17 -8.5 0 8.5
⎛ ⎞
esf_en_x ⎜――
2 ⎟
⎝ ⎠
Grafico de Esfuerzos en los extremos de la viga
65
58.5
52
45.5
39
32.5
26
esf_extremos ( )
19.5
13
6.5
0
-135-120-105-90 -75 -60 -45 -30 -15 0 15 30
⎛ ⎞
esf2_en_x ⎜――
2 ⎟
⎝ ⎠
Mu = 73000 ⋅ :MOMENTO FLECTOR EXTERIOR ACTUANTE SOBRE A VIGA
Fy ≔ 4200 ―― :Esfuerzo de fluencia de acero normal
2
fps Se puede calcular con la siguiente fórmula siempre y cuando el esfuerzo efectivo de trabajo fpe
luego de que se den las pérdidas, no sea menor a 0.50fpu, es decir el 50% del esfuerzo último
especificado (19000kg/cm2) para aceros de grado 270ksi.
fpy
―― = 0.901
fpu
dp ≔ h − ŷ + e = 58.23 :distanncia de la fibra superior al centroide del
cable
γp = 0.55 :usualmente para barras de
pretensar
f'c
β1 ≔ 1.05 − 0.05 ⋅ ―――= 0.76 :Coeficiente para calcular la profundidad del
70 ―― bloque de compresion, en funcion de f'c
2
*En este caso no te ul liza acero adicional ni a tensión ni a compresión:
∴ ρ' ≔ 0 :Cuan a de acero a compresión
∴ d' ≔ 0 :Peralte de acero a compresión
∴ ρ≔0 :Cuan a de acero a tensión
∴ d≔0 :Peralte de acero a tensión
Fy
w ≔ ρ ⋅ ―― =0
f'c
Fy ⎛ fpu d ⎞
w' ≔ ρ' ⋅ ―― =0 ∴ cond ≔ ⎜ρp ⋅ ―― + ―⋅ (w − w')⎟ = 0.042
f'c ⎝ f'c dp ⎠
∴ val ≔ (w' > 0 ∧ cond ≤ 0.17 , 0.17 , cond) = 0.042
*y tambien d' no debe ser mayor a 0.15 dp , de no cumplirse
esto, w' se toma = 0 d' ≔ 0 0.15 ⋅ dp = 8.734
∴ = “cumple”
⎛ γp ⎞
∴ fps ≔ fpu ⋅ ⎜1 − ― ⋅ (val)⎟ = 18419.8 ――
2
⎝ β1 ⎠
Ap ⋅ fps
a ≔ ―――― = 2.82
0.85 ⋅ f'c ⋅ b
⎛ a⎞
∴ Mn ≔ Ap ⋅ fps ⋅ ⎜dp − ―
⎝ 2 ⎟⎠
∴ ϕMn ≔ 0.9 ⋅ Mn = 78385 ⋅ : Cuando solo hay cable de pretensado
Mu
Demand_capacidad ≔ ――⋅ 100 = 93 : % al que trabaja la sección
ϕMn
5) FLEXIÓN SECCIÓN I
5.1-.introduccion de datos por el usuario
Geometira de la sección
b ≔ 70 : ancho de sección I
h ≔ 75 : altura de la seción I
L ≔ 12 : Logitud de la viga considerada
2
Ac ≔ ⎛⎝2 ⋅ tf ⋅ b⎞⎠ + tw ⋅ ⎛⎝h − 2 ⋅ tf⎞⎠ = 3675
: Ordenada del
b ⋅ tf ⋅ 0.5 ⋅ tf + tw ⋅ ⎛⎝h − 2 ⋅ tf⎞⎠ ⋅ ⎛⎝tf + 0.5 ⋅ ⎛⎝h − 2 ⋅ tf⎞⎠⎞⎠ + b ⋅ tf ⋅ ⎛⎝h − 0.5 ⋅ tf⎞⎠
ŷ ≔ ――――――――――――――――――――― C.G. de la sección
tw ⋅ ⎛⎝h − 2 ⋅ tf⎞⎠ + 2 ⋅ b ⋅ tf
∴ ŷ = 37.5
k1 ≔ h − 2 ⋅ tf
k2 ≔ h − 0.5 ⋅ tf
3 3
tf 2 k1 2 2
Ix ≔ 2 ⋅ b ⋅ ―― + b ⋅ tf ⋅ ⎛⎝0.5 ⋅ tf − ŷ⎞⎠ + tw ⋅ ―― + tw ⋅ k1 ⋅ ⎛⎝tf + 0.5 ⋅ k1 − ŷ⎞⎠ + b ⋅ tf ⋅ (k2 − ŷ)
12 12
4
∴ Ix = 2195156.25
‾‾‾
Ix
r≔ ― = 24.4
Ac
‾‾‾‾‾‾‾
Ec ≔ 15100 ⋅ f'c ⋅ ――= 302000 ――
2 2
‾‾‾‾‾‾‾‾
Eci ≔ 15100 ⋅ f'ci ⋅ ――= 282495.1 ――
2 2
2
∴ A ≔ 1.387 :Area del acero de 0.6 pulgadas (ver tabla 1 de tipos de cables )
2
Ap ≔ #cables ⋅ A = 6.935 :Area total de acero de preesfuerzo
fpi
ε≔― = 0.007
Ep
ŷ = 37.5
⎛ ⎛⎝tw − 2 ⋅ recp⎞⎠ ⎞
Sp ≔ ⎜#cables > 1 , ――――― ,0 ⎟
⎝ #cables − 1 ⎠
75
67.5
60
52.5
45
37.5
30
22.5
15
7.5
0
-40 -30 -20 -10 0 10 20 30 40 50 60 70 80
‐Debido a la fuerza del gato de preesforazdo :
Y el máximo establecido
pero no mayor que el mínimo entre: 0.80 ⋅ fpu = 15200 ―― por el fabricante o por
2
los diposi vos de anclaje
∴ con = “cumple”
‐Justo después de la trasferencia del esfuerzo de preesfuerzo:
∴ con1 = “cumple”
En estado elás co, los esfuerzos en las fibras extrema superior e inferior de la sección
( , ), están dadas por las siguientes expresiones de flexión básica en estado elás co:
2
L
MD ≔ WD ⋅ ―― = 1587600 ⋅ :Momento flector máximo por peso propio
8
Ct ≔ h − ŷ = 37.5 :Distancia desde la L.N. a la fibra superior
Ix 3
St ≔ ― = 58537.5 :Módulo de la sección respecto a la fibra superior
Ct
Ix 3
Sb ≔ ― = 58537.5 :Módulo de la sección respecto a la fibra inferior
Cb
r = 24.44 :Radio de giro de la sección
Calculando los esfuerzos en el centro de la viga, que es donde actua el Momento Maximo
por peso propio:
−Pi ⎛ e ⋅ C t ⎞ MD
ft ≔ ―― ⋅ ⎜1 − ―― − ――= −2.12 ―― :Esfuerzo en fibra superior (+) Tracción
2 ⎟ 2
Ac ⎝ r ⎠ St
‾‾‾‾‾‾‾‾
Esfuerzo maximo en tracción ( no en extremos) 0.80 ⋅ f'ci ⋅ ――= 14.967 ――
2 2
= “cumple”
−Pi ⎛ e ⋅ Cb ⎞ MD
fb ≔ ―― ⋅ ⎜1 + ――⎟ + ―― = −50.7 ―― :Esfuerzo en fibra inferior (-) Compresión
2 2
Ac ⎝ r ⎠ S b
= “cumple”
Calculando los esfuerzos en los extremos de la viga , donde el peso propio no actua:
−Pi ⎛ e ⋅ Ct ⎞
ft1 ≔ ―― ⋅ ⎜1 − ―― = 25 ―― :Esfuerzo en fibra superior (+) Tracción
2 ⎟ 2
Ac ⎝ r ⎠
‾‾‾‾‾‾‾‾
Esfuerzo maximo en tracción ( en los extremos) 1.60 ⋅ f'ci ⋅ ――= 29.933 ――
2 2
= “cumple”
−Pi ⎛ e ⋅ Cb ⎞
fb1 ≔ ―― ⋅ ⎜1 + ――⎟ = −77.8 ―― :Esfuerzo en fibra inferior (-) Compresión
2 2
Ac ⎝ r ⎠
= “cumple”
Graficos de Esfuerzos iniciales al cortar los cables, en la fibra superior e inferior ‐
Grafico de Esfuerzos en la mitad de la viga
75
67.5
60
52.5
45
37.5
30
esfuerzos_mitad ( )
22.5
15
7.5
0
-51 -46 -41 -36 -31 -26 -21 -16 -11 -6 -1 4
⎛ ⎞
esf_en_x ⎜――
2 ⎟
⎝ ⎠
Grafico de Esfuerzos en los extremos de la viga
75
67.5
60
52.5
45
37.5
30
esf_extremos ( )
22.5
15
7.5
0
-80 -70 -60 -50 -40 -30 -20 -10 0 10 20 30
⎛ ⎞
esf2_en_x ⎜――
2 ⎟
⎝ ⎠
Mu = 73000 ⋅ :MOMENTO FLECTOR EXTERIOR ACTUANTE SOBRE A VIGA
Fy ≔ 4200 ―― :Esfuerzo de fluencia de acero normal
2
fps Se puede calcular con la siguiente fórmula siempre y cuando el esfuerzo efectivo de trabajo fpe
luego de que se den las pérdidas, no sea menor a 0.50fpu, es decir el 50% del esfuerzo último
especificado (19000kg/cm2) para aceros de grado 270ksi.
fpy
―― = 0.901
fpu
dp ≔ h − ŷ + e = 68.5 :distanncia de la fibra superior al centroide del
cable
γp = 0.55 :usualmente para barras de
pretensar
f'c
β1 ≔ 1.05 − 0.05 ⋅ ―――= 0.76 :Coeficiente para calcular la profundidad del
70 ―― bloque de compresion, en funcion de f'c
2
*En este caso no te ul liza acero adicional ni a tensión ni a compresión:
∴ ρ' ≔ 0 :Cuan a de acero a compresión
∴ d' ≔ 0 :Peralte de acero a compresión
∴ ρ≔0 :Cuan a de acero a tensión
∴ d≔0 :Peralte de acero a tensión
Fy
w ≔ ρ ⋅ ―― =0
f'c
Fy ⎛ fpu d ⎞
w' ≔ ρ' ⋅ ―― =0 ∴ cond ≔ ⎜ρp ⋅ ―― + ―⋅ (w − w')⎟ = 0.069
f'c ⎝ f'c dp ⎠
∴ val ≔ (w' > 0 ∧ cond ≤ 0.17 , 0.17 , cond) = 0.069
*y tambien d' no debe ser mayor a 0.15 dp , de no cumplirse
esto, w' se toma = 0 d' ≔ 0 0.15 ⋅ dp = 10.275
∴ = “cumple”
⎛ γp ⎞
∴ fps ≔ fpu ⋅ ⎜1 − ― ⋅ (val)⎟ = 18060.7 ――
2
⎝ β1 ⎠
Ap ⋅ fps
a ≔ ―――― = 5.26
0.85 ⋅ f'c ⋅ b
⎛ a⎞
∴ Mn ≔ Ap ⋅ fps ⋅ ⎜dp − ―
⎝ 2 ⎟⎠
∴ ϕMn ≔ 0.9 ⋅ Mn = 74251 ⋅ : Cuando solo hay cable de pretensado
Mu
Demand_capacidad ≔ ――⋅ 100 = 98 : % al que trabaja la sección
ϕMn
b ≔ 65 : ancho de sección
h ≔ 65 : altura de la seción
L ≔ 12 : Logitud de la viga considerada
ϕc ≔ 0.75 :Coeficiente de reducción para cortante
2.3-.Análisis a cortante:
"En elementos preesforzados con una fuerza activa mínima del 40% de la resistencia a la tracción del
refuerzo de flexión, se toma el valor dado por la siguienet expresión:,
bw ≔ (b − b1) = 0.45
λ: Factor de las variaciones de las propiedades mecánicas del hormigón, λ=1 para
hormigones de peso normal
"Para este análisis se asume que Mu ocurre conjuntamente con Vu"
⎛ ‾‾‾‾‾‾‾ Vu ⋅ dp ⎞
Vc ≔ ⎜0.16 ⋅ 1 ⋅ f'c ⋅ ――+ 49 ―― ⋅ ――― ⎟ ⋅ bw ⋅ dp
2 2
⎝ Mu ⎠
Vc = 31165.55
*Pero se debe cumplir que:
‾‾‾‾‾‾‾ ‾‾‾‾‾‾‾
0.53 ⋅ f'c ⋅ ――⋅ bw ⋅ dp = 27904.5 ≤ Vc ≤ 1.33 ⋅ f'c ⋅ ――⋅ bw ⋅ dp = 70024.5
2 2
∴ con1 = “cumple”
*tambien debe cumplir que:
Vu ⋅ dp Vu ⋅ dp
――― ≤1 ∴ = “cumple” ――― = 0.176
Mu Mu
∴ ϕc ⋅ Vc = 23374 :Resistencia solo del concreto
Vu
Demanda_capcidad ≔ ――― ⋅ 100 = 94.121 : % al que trabaja la sección
ϕc ⋅ Vc
Calculo de resistencia a cortante de acero de corte, solo si el hormigon no resiste
S = 30 :Espaciamiento miínio establecido
Av ⋅ fyt ⋅ dp
∴ Vs ≔ ―――― :Resistencia solo del acero de cortante
S
∴ ϕc ⋅ V s = 0
*pero se debe cumlir que:
‾‾‾‾‾‾‾kg
Vs < 2.2 ⋅f'c ⋅ ――⋅ bw ⋅ dp
2
cm
∴ con5 = “cumple”
3) CORTANTE SECCIÓN T:
Vu ≔ 22000 :CORTANTE EXTERNO ACUTANTE
2
Ac ≔ tf ⋅ b + tw ⋅ ⎛⎝h − tf⎞⎠ = 3600
3 3
k1 2 tf 2 4
Ix ≔ tw ⋅ ―― + ⎛⎝tw ⋅ k1⎞⎠ ⋅ (0.5 ⋅ k1 − ŷ) + b ⋅ ―― + ⎛⎝b ⋅ tf⎞⎠ ⋅ (k2 − ŷ) = 1888593.75
12 12
‾‾‾
Ix
r≔ ― = 22.9
Ac
3.2-.Dtaos adicionales :
dp ≔ h − ŷ + e = 68.38 :distanncia de la fibra superior al centroide del cable,
( dato del análisis a flexión)
ϕc ≔ 0.75 :Coeficiente de reducción para cortante
3.3-.Análisis a cortante:
"En elementos preesforzados con una fuerza activa mínima del 40% de la resistencia a la tracción del
refuerzo de flexión, se toma el valor dado por la siguienet expresión:,
λ: Factor de las variaciones de las propiedades mecánicas del hormigón, λ=1 para
hormigones de peso normal
En esta sección se toma: bw ≔ tw = 35
"Para este análisis se asume que Mu ocurre conjuntamente con Vu"
⎛ ‾‾‾‾‾‾‾ Vu ⋅ dp ⎞
Vc ≔ ⎜0.16 ⋅ 1 ⋅ f'c ⋅ ――+ 49 ―― ⋅ ――― ⎟ ⋅ bw ⋅ dp
2 2
⎝ Mu ⎠
Vc = 31821.43
*Pero se debe cumplir que:
‾‾‾‾‾‾‾ ‾‾‾‾‾‾‾
0.53 ⋅ f'c ⋅ ――⋅ bw ⋅ dp = 25367.13 ≤ Vc ≤ 1.33 ⋅ f'c ⋅ ――⋅ bw ⋅ dp = 63657.13
2 2
∴ con1 = “cumple”
*tambien debe cumplir que:
Vu ⋅ dp Vu ⋅ dp
――― ≤1 ∴ = “cumple” ――― = 0.206
Mu Mu
∴ ϕc ⋅ Vc = 23866 :Resistencia solo del concreto
Vu
Demanda_capcidad ≔ ――― ⋅ 100 = 92.181 : % al que trabaja la sección
ϕc ⋅ Vc
Calculo de resistencia a cortante de acero de corte, solo si el hormigon no resiste
S = 30 :Espaciamiento miínio establecido
Av ⋅ fyt ⋅ dp
∴ Vs ≔ ――――:Resistencia solo del acero de cortante
S
∴ ϕc ⋅ V s = 0
*pero se debe cumlir que:
‾‾‾‾‾‾‾kg
Vs < 2.2 ⋅ f'c ⋅ ――⋅ bw ⋅ dp
2
cm
∴ con5 = “cumple”
2
Ac ≔ tf ⋅ b + 2 ⋅ tw ⋅ ⎛⎝h − tf⎞⎠ = 4650
ŷ = 41.774
k1 ≔ h − tf
k2 ≔ h − 0.5 ⋅ tf
3 3
⎛ k1 ⎞ 2 tf 2 4
Ix ≔ 2 ⋅ ⎜tw ⋅ ―― ⎟ + 2 ⋅ ⎛
⎝wt ⋅ k1 ⎞
⎠ ⋅ (0.5 ⋅ k1 − ŷ ) + b ⋅ ―― + ⎛⎝b ⋅ tf⎞⎠ ⋅ (k2 − ŷ) = 1740362.9
⎝ 12 ⎠ 12
‾‾‾
Ix
r≔ ― = 19.3
Ac
4.2-.Dtaos adicionales :
dp ≔ h − ŷ + e = 58.23 :distanncia de la fibra superior al centroide del cable,
( dato del análisis a flexión)
ϕc ≔ 0.75 :Coeficiente de reducción para cortante
4.3-.Análisis a cortante:
"En elementos preesforzados con una fuerza activa mínima del 40% de la resistencia a la tracción del
refuerzo de flexión, se toma el valor dado por la siguienet expresión:,
λ: Factor de las variaciones de las propiedades mecánicas del hormigón, λ=1 para
hormigones de peso normal
En esta sección se toma: bw ≔ 2 ⋅ tw = 45
"Para este análisis se asume que Mu ocurre conjuntamente con Vu"
⎛ ‾‾‾‾‾‾‾ Vu ⋅ dp ⎞
Vc ≔ ⎜0.16 ⋅ 1 ⋅ f'c ⋅ ――+ 49 ―― ⋅ ――― ⎟ ⋅ bw ⋅ dp
2 2
⎝ Mu ⎠
Vc = 30913.39
*Pero se debe cumplir que:
‾‾‾‾‾‾‾ ‾‾‾‾‾‾‾
0.53 ⋅ f'c ⋅ ――⋅ bw ⋅ dp = 27773.71 ≤ Vc ≤ 1.33 ⋅ f'c ⋅ ――⋅ bw ⋅ dp = 69696.29
2 2
∴ con1 = “cumple”
*tambien debe cumplir que:
Vu ⋅ dp Vu ⋅ dp
――― ≤1 ∴ = “cumple” ――― = 0.175
Mu Mu
∴ ϕc ⋅ Vc = 23185 :Resistencia solo del concreto
Vu
Demanda_capcidad ≔ ――― ⋅ 100 = 94.889 : % al que trabaja la sección
ϕc ⋅ Vc
Calculo de resistencia a cortante de acero de corte, solo si el hormigon no resiste
S = 30 :Espaciamiento miínio establecido
Av ⋅ fyt ⋅ dp
∴ Vs ≔ ――――:Resistencia solo del acero de cortante
S
∴ ϕc ⋅ Vs = 9603.393
*pero se debe cumlir que:
‾‾‾‾‾‾‾kg
Vs < 2.2 ⋅ f'c ⋅ ――⋅ bw ⋅ dp
2
cm
∴ con5 = “cumple”
5) CORTANTE SECCIÓN I:
Vu ≔ 22000 :CORTANTE EXTERNO ACUTANTE
b ≔ 70 : ancho de sección I
h ≔ 75 : altura de la seción I
L ≔ 12 : Logitud de la viga considerada
2
Ac ≔ ⎛⎝2 ⋅ tf ⋅ b⎞⎠ + tw ⋅ ⎛⎝h − 2 ⋅ tf⎞⎠ = 3675
∴ ŷ = 37.5
k1 ≔ h − 2 ⋅ tf
k2 ≔ h − 0.5 ⋅ tf
3 3
tf 2 k1 2 2
Ix ≔ 2 ⋅ b ⋅ ―― + b ⋅ tf ⋅ ⎛⎝0.5 ⋅ tf − ŷ⎞⎠ + tw ⋅ ―― + tw ⋅ k1 ⋅ ⎛⎝tf + 0.5 ⋅ k1 − ŷ⎞⎠ + b ⋅ tf ⋅ (k2 − ŷ)
12 12
4
∴ Ix = 2195156.25
‾‾‾
Ix
r≔ ― = 24.4
Ac
5.2-.Dtaos adicionales :
dp ≔ h − ŷ + e = 68.5 :distanncia de la fibra superior al centroide del cable,
( dato del análisis a flexión)
ϕc ≔ 0.75 :Coeficiente de reducción para cortante
5.3-.Análisis a cortante:
"En elementos preesforzados con una fuerza activa mínima del 40% de la resistencia a la tracción del
refuerzo de flexión, se toma el valor dado por la siguienet expresión:,
λ: Factor de las variaciones de las propiedades mecánicas del hormigón, λ=1 para
hormigones de peso normal
En esta sección se toma: bw ≔ tw = 35
"Para este análisis se asume que Mu ocurre conjuntamente con Vu"
⎛ ‾‾‾‾‾‾‾ Vu ⋅ dp ⎞
Vc ≔ ⎜0.16 ⋅ 1 ⋅ f'c ⋅ ――+ 49 ―― ⋅ ――― ⎟ ⋅ bw ⋅ dp
2 2
⎝ Mu ⎠
Vc = 31923.86
*Pero se debe cumplir que:
‾‾‾‾‾‾‾ ‾‾‾‾‾‾‾
0.53 ⋅ f'c ⋅ ――⋅ bw ⋅ dp = 25413.5 ≤ Vc ≤ 1.33 ⋅ f'c ⋅ ――⋅ bw ⋅ dp = 63773.5
2 2
∴ con1 = “cumple”
*tambien debe cumplir que:
Vu ⋅ dp Vu ⋅ dp
――― ≤1 ∴ = “cumple” ――― = 0.206
Mu Mu
∴ ϕc ⋅ Vc = 23943 :Resistencia solo del concreto
Vu
Demanda_capcidad ≔ ――― ⋅ 100 = 91.885 : % al que trabaja la sección
ϕc ⋅ Vc
Calculo de resistencia a cortante de acero de corte, solo si el hormigon no resiste
S = 30 :Espaciamiento miínio establecido
Av ⋅ fyt ⋅ dp
Vs ≔ ――――:Resistencia solo del acero de cortante
S
ϕc ⋅ V s = 0
*pero se debe cumlir que:
‾‾‾‾‾‾‾kg
Vs < 2.2 ⋅ f'c ⋅ ――⋅ bw ⋅ dp
2
cm
∴ con5 = “cumple”
DISEÑO A TORSIÓN :
2) SECCION RECTANGULAR -TRAZADO CARAS
SUPERIOR e INFERIOR - MEDIAS PARABOLAS
ex ≔ 50 :Brazo de torsión
:Carga actuante en un extremo de la viga a lo largo de
Pext
qext ≔ ―― = 2500 ― su longitud para producir torsion
L
bt ≔ h − 2 ⋅ h' = 51 :Brazo de palanca entre cables de torsión
2
Ap ≔ #cables ⋅ A = 11.096 :Area total del acero usado:
2
f'c ≔ 400 ―― Acp ≔ h ⋅ b = 3250 :Area de sección transversal
2
Pcp ≔ 2 ⋅ (h + b) = 230 :Perímetro de sección transversal
2
‾‾‾‾‾‾‾ Acp
Tcr ≔ 4 ⋅ f'c ⋅ ―― ⋅ ――= 845529.12 ⋅
2
Pcp
Mtu ⋅ L
P ≔ ――――――― = −154660.3 :Fuerza de tensado necessaria en el
2 ⋅ (h − 2 h') ⋅ (2 ⋅ b' − b) cable
⎛ Mtu 2 ⎞
z (x) ≔ ⎜―――――― ⋅ x − b'⎟ :Ecuación final del trazado, para las caras
⎝ 2 ⋅ P ⋅ L ⋅ (h − 2 h') ⎠ superior e inferior
w = −0.003 w1 = −0.05 z (0 ) = −5
z (L) = −45
2
f (t) ≔ w ⋅ t + w1 :Ecuacion q se forma
-5 0 1 2 3 4 5 6 7 8 9 10 11 12
-9
-13
-17
-21
-25
-29 z (x) ( )
-33
-37
-41
-45
x ( )
71
65
59
53
47
41
35
29
−z (x) ( )
23
17
11
5
0 1 2 3 4 5 6 7 8 9 10 11 12
x ( )
Pext ⎛ 3
qext ≔ ―― = ⎝2.5 ⋅ 10 ⎞⎠ ― :Carga actuante en un extremo de la viga a lo largo de
L su longitud para producir torsion
bt ≔ h − 2 ⋅ h' = 51 :Brazo de palanca entre cables de torsión
2
Ap ≔ #cables ⋅ A = 1.387 :Area total del acero usado:
2
f'c ≔ 400 ―― Acp ≔ h ⋅ b = 4225 :Area de sección transversal
2
Pcp ≔ 2 ⋅ (h + b) = 260 :Perímetro de sección transversal
2
‾‾‾‾‾‾‾ Acp
Tcr ≔ 4 ⋅ f'c ⋅ ―― ⋅ ――= 1264066.035 ⋅
2
Pcp
−Mtu ⋅ L
P ≔ ――――――― = −2333.6 :Fuerza de tensado necessaria en el
8 ⋅ (h − 2 h') ⋅ (b − 2 ⋅ b') cable
:Esfuerso incial de tensado necesario, luego de
Pf
∴ fpi ≔ ― = −1851 ―― haber restado las perdidas instantaneas
2
Ap
⎛ ⎞ :Ecuación final del trazado, para las
Mtu 2 4 (b − 2 ⋅ b') ⋅ x
z (x) ≔ ⎜―――――― ⋅ x + ――――― − b + b'⎟ caras superior e inferior
⎝ 2 ⋅ L ⋅ P ⋅ (h − 2 h') L ⎠
z (0 ) = −60
z (L) = −60
k1 = −0.015 k2 = 0.183 k3 = −0.7 z (0.5 ⋅ L) = −5
2
Z (x) ≔ k1 ⋅ x + k2 ⋅ x + k3 :Ecuacion q se forma
0.005
-0.05 0 1 2 3 4 5 6 7 8 9 10 11 12
-0.105
-0.16
-0.215
-0.27
-0.325
-0.38
z (x) ( )
-0.435
-0.49
-0.545
-0.6
x ( )
0.65
0.595
0.54
0.485
0.43
0.375
0.32
0.265
−z (x) ( )
0.21
0.155
0.1
0.045
0 1 2 3 4 5 6 7 8 9 10 11 12
x ( )
tw ≔ 35 : espesor del alma
tf ≔ 15 : espesor del ala/pa n L ≔ 12 :Luz de viga
Debido a que el trazado es en el alma, para el análisis se asume: b ≔ tw
∴ b ≔ tw = 35
ex ≔ 50 :Brazo de torsión
:Carga actuante en un extremo de la viga a lo largo de
Pext
qext ≔ ―― = 2500 ― su longitud para producir torsion
L
bt ≔ b − 2 ⋅ b' = 27 :Brazo de palanca entre cables de torsión
2
Ap ≔ #cables ⋅ A = 4.161 :Area total del acero usado:
2
f'c ≔ 400 ―― Acp ≔ Ac = 3600 :Area de sección transversal
2
Pcp ≔ Perim = 285 :Perímetro de sección transversal
2
‾‾‾‾‾‾‾ Acp
Tcr ≔ 4 ⋅ f'c ⋅ ―― ⋅ ――= 837239.722 ⋅
2
Pcp
−Mtu ⋅ L
P ≔ ――――――― = −48761 :Fuerza de tensado necessaria en el
8 ⋅ (h − 2 h') ⋅ (b − 2 ⋅ b') cable, luego de haber restado
perdidas
:Esfuerso incial de tensado necesario, luego de
Pf
∴ fpi ≔ ― = −12890 ―― haber restado las perdidas instantaneas
2
Ap
⎛ Mtu 2 4 (b − 2 ⋅ b') ⋅ x ⎞
z (x) ≔ ⎜―――――― ⋅ x + ――――― − b + b'⎟ :Ecuación final del trazado, para las
⎝ 2 ⋅ L ⋅ P ⋅ (h − 2 h') L ⎠ caras superior e inferior
z (0 ) = −31
z (L) = −31
k1 = −0.008 k2 = 0.09 k3 = −0.39 z (0.5 ⋅ L) = −4
2
Z (x) ≔ k1 ⋅ x + k2 ⋅ x + k3 :Ecuacion q se forma
-2 0 1 2 3 4 5 6 7 8 9 10 11 12
-5
-8
-11
-14
-17
-20
-23
z (x) ( )
-26
-29
-32
-35
x ( )
Trazado de vista cara inferior:
37
34
31
28
25
22
19
16
−z (x) ( )
13
10
7
4
0 1 2 3 4 5 6 7 8 9 10 11 12
x ( )
tw ≔ 35 : espesor del alma
tf ≔ 15 : espesor del ala/pa n
2
Ac ≔ ⎛⎝2 ⋅ tf ⋅ b⎞⎠ + tw ⋅ ⎛⎝h − 2 ⋅ tf⎞⎠ = 3675
ex ≔ 50 :Brazo de torsión
:Carga actuante en un extremo de la viga a lo largo de
Pext
qext ≔ ―― = 2500 ― su longitud para producir torsion
L
bt ≔ h − 2 ⋅ h' = 61 :Brazo de palanca entre cables de torsión
2
Ap ≔ #cables ⋅ A = 2.774 :Area total del acero usado:
2
f'c ≔ 400 ―― Acp ≔ Ac = 3675 :Area de sección transversal
2
Pcp ≔ Perim = 330 :Perímetro de sección transversal
2
‾‾‾‾‾‾‾ Acp
Tcr ≔ 4 ⋅ f'c ⋅ ―― ⋅ ――= 753512.447 ⋅
2
Pcp
−Mtu ⋅ L
P ≔ ――――――― = −25895.9 :Fuerza de tensado necessaria en el
8 ⋅ (h − 2 h') ⋅ (b − 2 ⋅ b') cable, luego de haber restado perdidas
:Esfuerso incial de tensado necesario, luego de
Pf
∴ fpi ≔ ― = −10269 ―― haber restado las perdidas instantaneas
2
Ap
⎛ Mtu 2 4 (b − 2 ⋅ b') ⋅ x ⎞
z (x) ≔ ⎜―――――― ⋅ x + ――――― − b + b'⎟ :Ecuación final del trazado, para las
⎝ 2 ⋅ L ⋅ P ⋅ (h − 2 h') L ⎠ caras superior e inferior
z (0 ) = −65
z (L) = −65
k1 = −0.017 k2 = 0.2 k3 = −0.65 z (0.5 ⋅ L) = −5
2
Z (x) ≔ k1 ⋅ x + k2 ⋅ x + k3 :Ecuacion q se forma
0.01
0 1 2 3 4 5 6 7 8 9 10 11 12
-0.05
-0.11
-0.17
-0.23
-0.29
-0.35
-0.41
z (x) ( )
-0.47
-0.53
-0.59
-0.65
x ( )
0.705
0.645
0.585
0.525
0.465
0.405
0.345
0.285
−z (x) ( )
0.225
0.165
0.105
0.045
0 1 2 3 4 5 6 7 8 9 10 11 12
x ( )
L = 12 :Luz de viga
tw ≔ 22.5 : espesor de las almas
b1 ≔ 80 : ancho intermedio
tf ≔ 15 : espesor del ala/pa n
bws ≔ b1 = 80 :distancia entre cables de pretensado, igual a la distancia
entre ejes de las almas de la viga doble T
2
Ac ≔ tf ⋅ b + 2 ⋅ tw ⋅ ⎛⎝h − tf⎞⎠ = 4650
b ≔ tw = 22.5 :ancho b asumido
ex ≔ 50 :Brazo de torsión
Pext
qext ≔ ―― = 25 ―― :Carga actuante en un extremo de la viga a lo largo de
L su longitud para producir torsion, como se mostro en
la figura enterior
bt ≔ bws = 80 :Brazo de palanca entre cables de torsión
2
Ap ≔ #cables ⋅ A = 1.387 :Area total del acero usado:
2
f'c ≔ 400 ―― Acp ≔ Ac = 4650 :Area de sección transversal
2
Pcp ≔ Perim = 415 :Perímetro de sección transversal
2
‾‾‾‾‾‾‾ Acp
Tcr ≔ 4 ⋅ f'c ⋅ ―― ⋅ ――= 959284.644 ⋅
2
Pcp
−Mtu ⋅ L
P ≔ ―――――― = −14514.1 :Fuerza de tensado necessaria en el
8 ⋅ bws ⋅ (h − 2 h') cable, luego de haber restado perdidas
:Esfuerso incial de tensado necesario, luego de
Pf
∴ fpi ≔ ― = −11511 ―― haber restado las perdidas instantaneas
2
Ap
⎛ Mtu 2 Mtu ⋅ x ⎞
z (x) ≔ ⎜――――⋅ x − ―――+ h'⎟ :Ecuación final del trazado, para las caras
⎝ 2 ⋅ L ⋅ P ⋅ bws 2 ⋅ P ⋅ bws ⎠ superior e inferior
z (0 ) = 7
z (L) = 7
k1 = −0.014 k2 = −0.17 k3 = 0.07 z (0.5 ⋅ L) = 58
2
Z (x) ≔ k1 ⋅ x + k2 ⋅ x + k3 :Ecuacion q se forma
62
57
52
47
42
37
32
27 z (x) ( )
22
17
12
7
0 1 2 3 4 5 6 7 8 9 10 11 12
x ( )
0 1 2 3 4 5 6 7 8 9 10 11 12
-3.5
-8.5
-13.5
-18.5
-23.5
-28.5
-33.5
-38.5
−z (x) ( )
-43.5
-48.5
-53.5
-58.5
x ( )
ex ≔ 50 :Brazo de torsión
:Carga actuante en un extremo de la viga a lo largo de
Pext
qext ≔ ―― = 25 ―― su longitud para producir torsion
L
bt ≔ b − 2 ⋅ b' = 36 :Brazo de palanca entre cables de torsión
2
Ap ≔ #cables ⋅ A = 11.096 :Area total del acero usado:
2
f'c ≔ 400 ―― Acp ≔ h ⋅ b = 3250 :Area de sección transversal
2
Pcp ≔ 2 ⋅ (h + b) = 230 :Perímetro de sección transversal
2
‾‾‾‾‾‾‾ Acp
Tcr ≔ 4 ⋅ f'c ⋅ ―― ⋅ ――= 845529.12 ⋅
2
Pcp
Mtu ⋅ L
P ≔ ――――――― = −159347 :Fuerza de tensado necessaria en el cable,
2 ⋅ (b − 2 b') ⋅ (2 ⋅ h' − h) luego de haber restado perdidas
⎛ ⎞ :Ecuación final del trazado, para las caras
Mtu 2
z (x) ≔ ⎜―――――― ⋅ x − h'⎟ superior e inferior solo habra que
⎝ 2 ⋅ P ⋅ L ⋅ (b − 2 b') ⎠ cambiarle el signo
z (0 ) = −5
z (L) = −60
w = −0.004 w1 = −0.05
2
f (t) ≔ w ⋅ t + w1 :Ecuacion q se forma
0
-5.5 0 1 2 3 4 5 6 7 8 9 10 11 12
-11
-16.5
-22
-27.5
-33
-38.5
z (x) ( )
-44
-49.5
-55
-60.5
x ( )
71
65
59
53
47
41
35
29
−z (x) ( )
23
17
11
5
0 1 2 3 4 5 6 7 8 9 10 11 12
x ( )
ex ≔ 50 :Brazo de torsión
:Carga actuante en un extremo de la viga a lo largo de
Pext
qext ≔ ―― = 25 ―― su longitud para producir torsion
L
bt ≔ b − 2 ⋅ b' = 36 :Brazo de palanca entre cables de torsión
2
Ap ≔ #cables ⋅ A = 2.774 :Area total del acero usado:
2
f'c ≔ 400 ―― Acp ≔ h ⋅ b = 3250 :Area de sección transversal
2
Pcp ≔ 2 ⋅ (h + b) = 230 :Perímetro de sección transversal
2
‾‾‾‾‾‾‾ Acp
Tcr ≔ 4 ⋅ f'c ⋅ ―― ⋅ ――= 845529.12 ⋅
2
Pcp
−Mtu ⋅ L
P ≔ ――――――― = −39836.7 :Fuerza de tensado necessaria en el
8 ⋅ (b − 2 b') ⋅ (h − 2 ⋅ h') cable, luego de haber restado perdidas
⎛ Mtu 2 4 (h − 2 ⋅ h') ⋅ x ⎞
z (x) ≔ ⎜―――――― ⋅ x + ――――― − h + h'⎟ :Ecuación final del trazado, para las
⎝ 2 ⋅ L ⋅ P ⋅ (b − 2 b') L ⎠ caras superior e inferior
z (0 ) = −60
z (L) = −60
k1 = −0.015 k2 = 0.183 k3 = −0.7 z (0.5 ⋅ L) = −5
2
Z (x) ≔ k1 ⋅ x + k2 ⋅ x + k3 :Ecuacion q se forma
0
-5 0 1 2 3 4 5 6 7 8 9 10 11 12
-10
-15
-20
-25
-30
-35 z (x) ( )
-40
-45
-50
-55
x ( )
59.5
54.5
49.5
44.5
39.5
34.5
29.5
24.5 −z (x) ( )
19.5
14.5
9.5
4.5
0 1 2 3 4 5 6 7 8 9 10 11 12
x ( )
:Carga actuante en un extremo de la viga a lo largo de
Pext
qext ≔ ―― = 25 ―― su longitud para producir torsion
L
bt ≔ b − 2 ⋅ b' = 55 :Brazo de palanca entre cables de torsión
2
Ap ≔ #cables ⋅ A = 1.387 :Area total del acero usado:
2
f'c ≔ 400 ―― Acp ≔ h ⋅ b = 4225 :Area de sección transversal
2
Pcp ≔ 2 ⋅ (h + b) = 260 :Perímetro de sección transversal
2
‾‾‾‾‾‾‾ Acp
Tcr ≔ 4 ⋅ f'c ⋅ ―― ⋅ ――= 1264066.035 ⋅
2
Pcp
−Mtu ⋅ L
P ≔ ――――――― = −2333.6 :Fuerza de tensado necessaria en el
8 ⋅ (b − 2 b') ⋅ (h − 2 ⋅ h') cable, luego de haber restado perdidas
⎛ Mtu 2 Mtu ⋅ x ⎞
z (x) ≔ ⎜―――――― ⋅ x − ――――― − h + h'⎟
⎝ 2 ⋅ L ⋅ P ⋅ (b − 2 b') 2 ⋅ P ⋅ (b − 2 b') ⎠
⎛ −4 (h − 2 ⋅ h') 2 4 (h − 2 ⋅ h') ⎞
z (x) ≔ ⎜――――― ⋅ x + ――――⋅ x − h + h'⎟
2
⎝ L L ⎠
0 1 2 3 4 5 6 7 8 9 10 11 12
-5
-10
-15
-20
-25
-30
-35 z (x) ( )
-40
-45
-50
-55
x ( )
57
52
47
42
37
32
27 −z (x) ( )
22
17
12
7
0 1 2 3 4 5 6 7 8 9 10 11 12
x ( )
b ≔ 65 : ancho de sección
h ≔ 65 : altura de la seción
L ≔ 12 : Logitud de la viga considerada
b1 ≔ 20 : ancho de parte hueca
h1 ≔ 40 : altura de parte hueca ( esta parte
quedara en el centro de la sección)
3 3
h h1 4
Ix ≔ b ⋅ ― − b1 ⋅ ―― = 1380885.417
12 12
2
Ac ≔ b ⋅ h − b1 ⋅ h1 = 3425 Pr ≔ 2 ⋅ (b + h) = 260
‾‾‾
Ix
r≔ ― = 20.1
Ac
γ ≔ 2400 ―― :Peso especifico del hormigón
3
‾‾‾‾‾‾‾
Ec ≔ 15100 ⋅ f'c ⋅ ――= 302000 ――
2 2
‾‾‾‾‾‾‾‾
Eci ≔ 15100 ⋅ f'ci ⋅ ――= 282495.1 ――
2 2
Tipo de cable u lizado: torones grado 270ksi con a = 1.387cm2
2
∴ A ≔ 1.387 :Area del acero de 0.6 pulgadas (ver tabla 1 de pos de cables )
#cables ≔ 6 :Número de cables para flexión
2
Ap ≔ #cables ⋅ A = 8.322 :Area total de acero de preesfuerzo
e ≔ 26 :Distancia del eje neutro de la sección al centroide del acero de
preesfuerzo
ANÁLISIS DE PÉRDIDAS
1: Perdida por el acortamiento instantáneo del Hormigón
fpi
ε≔― = 0.007 :Deformación unitaria en el cable
Ep
P i ⋅ Lb
δ ≔ ――― = 35 :Deformación total del cable
Ep ⋅ Ap
fc : esfuerzo promedio del hormigon debido a Pi
Pi
εc ≔ ――― = 0.000113 :Deformación unitaria en el hormigón
Ac ⋅ Ec
Ahora se calcula la pérdida del cable:
WD ≔ Ac ⋅ γ = 8.22 ―― :Peso propio por unidad de longitud
Ep
ni ≔ ―― = 7.08 :Relación de modulos de elas cidad incial (al cortar los cables)
Eci
Ep
n≔― = 6.62 :Relación de modulos de elas cidad incial (al los 28 días)
Ec
e = 26 :distancia del C.G de la sección al centroide del cable
2
L
MD ≔ WD ⋅ ―― = 1479600 ⋅ :Momento flector por peso propio
8
2
−Pi ⎛ e ⎞ e ⋅ MD
fcp ≔ ―― ⎜ 1 + ― ⎟ + ――― = −63.19 ―― :Esfuerzo en el hormigón a la distancia
2 2
Ac ⎝ r ⎠ Ix e del cable
Pérdida en acero de pretensar al momento de cortar los cables:
PT ≔ 2333.6 :Fuerza Pi de los cables de Torsión
PT
fcp1 ≔ −2 ⋅ ―― = −1.363 ―― : fcp1 de los cables de Torsión
2
Ac
u ≔ 0.65 :valor promedio especificado por la AASHTO
Lb = 50 : Longitud de bancada
u
Δfpa ≔ Ep ⋅ ―= 260 ――
2
Lb
en lugar de usar la relacion V/S se puede usar A/P mas rapidadmente :
HR ≔ 70 HR: humedad rela va ambiental (supuesta)
−6 Ep ⎛ Ac ⎞
Δfcr ≔ 8.2 ⋅ 10 ⋅ ――⋅ ⎜1 − 0.0236 ⋅ ―― ⎟ ⋅ (100 − HR)
⎝ Pr ⎠
Δfcr = 339 ――
2
t ≔ 1825 :dias =(5 años)
0.60
t
Ct ≔ ―――⋅ Cu = 2.12 : Coeficiente de deformación plás ca a la edad de t días
0.60
10 + t
⎛ Ep ⎞
Δfcf ≔ abs ⎜Ct ⋅ ― fcp + fcp1⎟ :Pérdias considerando los cables de
⎝ Ec ⎠ flexón y torsión
Δfcf = 887 ――
2
t ≔ t ⋅ 24 = 43800 horas =(5 años)
Δfr = 386.6 ――
2
*sumando todas las perdidas para obtener el total: Esfuerzo inicial de
pretensado
Δfpt ≔ Δfr + Δfcf + Δfcr + Δfpa + Δfpe = 2330 ―― fpi = 14000 ――
2 2
∴ = “cumple rango”
" Rango de perdidas permitido segun el PCI : 1760kg/cm2 y 3520 kg/cm2 "
100 ⋅ Δfpt
expresado en % de fpi : porcentj ≔ ―――― = 17
fpi
CÁLCULO DE DELFEXIONES:
L
―― = 2.5 :Valor elegido de la tabla 5 de la sección 2.7 (Deflexiónes) por ser el
480
menor para luego comparar con el calculado
W ≔ Ac ⋅ γ = 8.22 ―― :Carga debida a peso propio
Perin
Porcj ≔ ―― ⋅ 100 = 5.1 :Pérdidas Instantáneas en % (5‐10)
fpi
2
e = 26 Eci = 282495.13 ―― Ap = 8.322
2
fpi = 14000 ――
2
4
5⋅W⋅L
Δpp ≔ −―――― = −0.57 :Deflexión por peso propio
384 ⋅ Eci ⋅ Ix
2
5 P⋅e⋅L
Δcamber ≔ ― ⋅ ―――= 1.105 :Deflexión por el camber producido
48 Eci ⋅ Ix
METODO DE LOS MULTIPLICADORES PARA ESTIMAR LAS DEFLEXIONES A LARGO PLAZO:
*Para este elemento se analizará con los mul pllicadores C1 sin losa sobre elementos
pretensados, tomados de la tabla 6 del cap tulo 3 sección 3.5.1
Al izar el elemento deflexion:
δi ≔ 1.8 ⋅ Δcamber − abs ⎛⎝1.85 ⋅ Δpp⎞⎠ = 0.94 :Calculado con los coeficientes tomados
de la tabla 6, sección 3.5.1
Final o después de 5 anios: :Calculado con los
δfinal ≔ −abs ⎛⎝2.7 ⋅ Δpp⎞⎠ + 2.45 ⋅ Δcamber − abs ⎛⎝3 ⋅ Δpp⎞⎠ = −0.54 coeficientes tomados
de la tabla 6
Para el 3er termino de esta ecuacion se considera como carga muerta
sobrepueta al peso propio del elemento
Para graficar la deflexión
ΔTot −4 1
C ≔ −―――― = −1.49 ⋅ 10 ― :Constante de la ecuacion y=cx^2+b
2
(−0.5 ⋅ L)
Grafico de la Deflexión de la viga por cables de flexión
5
4.5
4
3.5
3
2.5
2 f (x) ( )
1.5
1
0.5
0
-6 -5 -4 -3 -2 -1 0 1 2 3 4 5 6
x ( )
b ≔ 100 : ancho de sección
h ≔ 75 : altura de la seción
L ≔ 12 : Logitud de la viga considerada
tw ≔ 35 : espesor del alma
tf ≔ 15 : espesor del ala/pa n
2
Ac ≔ tf ⋅ b + tw ⋅ ⎛⎝h − tf⎞⎠ = 3600
3 3
k1 2 tf 2 4
Ix ≔ tw ⋅ ―― + ⎛⎝tw ⋅ k1⎞⎠ ⋅ (0.5 ⋅ k1 − ŷ) + b ⋅ ―― + ⎛⎝b ⋅ tf⎞⎠ ⋅ (k2 − ŷ) = 1888593.75
12 12
‾‾‾
Ix
r≔ ― = 22.9
Ac
γ ≔ 2400 ―― :Peso especifico del hormigón
3
‾‾‾‾‾‾‾
Ec ≔ 15100 ⋅ f'c ⋅ ――= 302000 ――
2 2
‾‾‾‾‾‾‾‾
Eci ≔ 15100 ⋅ f'ci ⋅ ――= 282495.1 ――
2 2
#cables ≔ 5 :Número de cables para flexión
2
Ap ≔ #cables ⋅ A = 6.935 :Area total de acero de preesfuerzo
e ≔ 39 :Distancia del eje neutro de la sección al centroide del acero de
preesfuerzo
ANÁLISIS DE PÉRDIDAS
1: Perdida por el acortamiento instantáneo del Hormigón
fpi
ε ≔ ― = 0.007 :Deformación unitaria en el cable
Ep
P i ⋅ Lb
δ ≔ ――― = 35 :Deformación total del cable
Ep ⋅ Ap
fc : esfuerzo promedio del hormigon debido a Pi
Pi
εc ≔ ――― = 0.000089 :Deformación unitaria en el hormigón
Ac ⋅ Ec
Ahora se calcula la pérdida del cable:
WD ≔ Ac ⋅ γ = 8.64 ―― :Peso propio por unidad de longitud
Ep
ni ≔ ―― = 7.08 :Relación de modulos de elas cidad incial (al cortar los cables)
Eci
Ep
n≔― = 6.62 :Relación de modulos de elas cidad incial (al los 28 días)
Ec
e = 39 :distancia del C.G de la sección al centroide del cable
2
L
MD ≔ WD ⋅ ―― = 1555200 ⋅ :Momento flector por peso propio
8
2
−Pi ⎛ e ⎞ e ⋅ MD
fcp ≔ ―― ⎜ 1 + ― ⎟ + ――― = −73.05 ―― :Esfuerzo en el hormigón a la distancia
2 2
Ac ⎝ r ⎠ Ix e del cable
Pérdida en acero de pretensar al momento de cortar los cables:
PT ≔ 48761 :Fuerza Pi de los cables de Torsión
PT
fcp1 ≔ −2 ⋅ ―― = −27.089 ―― : fcp1 de los cables de Torsión
2
Ac
:Pérdias considerando los cables de
Δfpe ≔ abs ⎝ni ⋅ ⎝fcp + fcp1⎠⎠ = 708.94 ―― flexón y torsión
⎛ ⎛ ⎞ ⎞
2
u ≔ 0.65 :valor promedio especificado por la AASHTO
Lb = 50 : Longitud de bancada
u
Δfpa ≔ Ep ⋅ ―= 260 ――
2
Lb
en lugar de usar la relacion V/S se puede usar A/P mas rapidadmente :
HR ≔ 70 HR: humedad rela va ambiental (supuesta)
−6 Ep ⎛ Ac ⎞
Δfcr ≔ 8.2 ⋅ 10 ⋅ ――⋅ ⎜1 − 0.0236 ⋅ ―― ⎟ ⋅ (100 − HR)
⎝ Pr ⎠
Δfcr = 331.2 ――
2
Δfcf = 1050.82 ――
2
t ≔ t ⋅ 24 = 43800 horas =(5 años)
Δfr = 386.6 ――
2
* d t d l did bt lt t l Ef i i i ld
*sumando todas las perdidas para obtener el total: Esfuerzo inicial de
pretensado
Δfpt ≔ Δfr + Δfcf + Δfcr + Δfpa + Δfpe = 2738 ―― fpi = 14000 ――
2 2
∴ = “cumple rango”
" Rango de perdidas permitido segun el PCI : 1760kg/cm2 y 3520 kg/cm2 "
100 ⋅ Δfpt
expresado en % de fpi : porcentj ≔ ―――― = 20
fpi
CÁLCULO DE DELFEXIONES:
L
―― = 2.5 :Valor elegido de la tabla 5 de la sección 2.7 (Deflexiónes) por ser el
480
menor para luego comparar con el calculado
W ≔ Ac ⋅ γ = 8.64 ―― :Carga debida a peso propio
Perin
Porcj ≔ ――⋅ 100 = 6.9 :Pérdidas Instantáneas en % (5‐10)
fpi
2
e = 39 Eci = 282495.13 ―― Ap = 6.935
2
fpi = 14000 ――
2
4
5⋅W⋅L
Δpp ≔ −―――― = −0.44 :Deflexión por peso propio
384 ⋅ Eci ⋅ Ix
2
5 P⋅e⋅L
Δcamber ≔ ― ⋅ ―――= 0.991 :Deflexión por el camber producido
48 Eci ⋅ Ix
METODO DE LOS MULTIPLICADORES PARA ESTIMAR LAS DEFLEXIONES A LARGO PLAZO:
*Para este elemento se analizará con los mul pllicadores C1 sin losa sobre elementos
pretensados, tomados de la tabla 6 del cap tulo 3 sección 3.5.1
Al i l l d fl i
Al izar el elemento deflexion:
δi ≔ 1.8 ⋅ Δcamber − abs ⎛⎝1.85 ⋅ Δpp⎞⎠ = 0.97 :Calculado con los coeficientes tomados
de la tabla 6, sección 3.5.1
Final o después de 5 anios: :Calculado con los
δfinal ≔ −abs ⎛⎝2.7 ⋅ Δpp⎞⎠ + 2.45 ⋅ Δcamber − abs ⎛⎝3 ⋅ Δpp⎞⎠ = −0.06 coeficientes tomados
de la tabla 6
Para el 3er termino de esta ecuacion se considera como carga muerta
sobrepueta al peso propio del elemento
Para graficar la deflexión
ΔTot −4 1
C ≔ −―――― = −1.54 ⋅ 10 ― :Constante de la ecuacion y=cx^2+b
2
(−0.5 ⋅ L)
Grafico de la Deflexión de la viga por cables de flexión
5
4.5
4
3.5
3
2.5
2 f (x) ( )
1.5
1
0.5
0
-6 -5 -4 -3 -2 -1 0 1 2 3 4 5 6
x ( )
b ≔ 1.60 : ancho total de sección doble T
h ≔ 65 : altura de la seción doble
L ≔ 12 T
: Logitud de la viga considerada
b1 ≔ 80 : ancho de las alas salientes
tw ≔ 22.5 : espesor de las almas
tf ≔ 15 : espesor del ala/pa n
2
Ac ≔ tf ⋅ b + 2 ⋅ tw ⋅ ⎛⎝h − tf⎞⎠ = 4650
3 3
⎛ k1 ⎞ 2 tf 2 4
Ix ≔ 2 ⋅ ⎜tw ⋅ ―― ⎟ + 2 ⋅ ⎛
⎝wt ⋅ k1 ⎞
⎠ ⋅ (0.5 ⋅ k1 − ŷ ) + b ⋅ ―― + ⎛⎝b ⋅ tf⎞⎠ ⋅ (k2 − ŷ) = 1740362.9
⎝ 12 ⎠ 12
‾‾‾
Ix
r≔ ― = 19.3
Ac
γ ≔ 2400 ―― :Peso especifico del hormigón
3
‾‾‾‾‾‾‾
Ec ≔ 15100 ⋅ f'c ⋅ ――= 302000 ――
2 2
‾‾‾‾‾‾‾‾
Eci ≔ 15100 ⋅ f'ci ⋅ ――= 282495.1 ――
2 2
Tipo de cable u lizado: torones grado 270ksi con a = 1.387cm2
2
∴ A ≔ 1.387 :Area del acero de 0.6 pulgadas (ver tabla 1 de pos de cables )
"El numero de caables debe ser par para que se distribuya uniformemente en las 2 almas"
#cables ≔ 6 :Número de cables para flexión
2
Ap ≔ #cables ⋅ A = 8.322 :Area total de acero de preesfuerzo
fpi
ε≔― = 0.007
Ep
ŷ = 41.7741935
e ≔ 35 :Distancia del eje neutro de la sección al centroide del acero de
preesfuerzo
ANÁLISIS DE PÉRDIDAS
1: Perdida por el acortamiento instantáneo del Hormigón
fpi
ε ≔ ― = 0.007 :Deformación unitaria en el cable
Ep
P i ⋅ Lb
δ ≔ ――― = 35 :Deformación total del cable
Ep ⋅ Ap
fc : esfuerzo promedio del hormigon debido a Pi
Pi
εc ≔ ――― = 0.000083 :Deformación unitaria en el hormigón
Ac ⋅ Ec
Ahora se calcula la pérdida del cable:
WD ≔ Ac ⋅ γ = 11.16 ――:Peso propio por unidad de longitud
Ep
ni ≔ ―― = 7.08 :Relación de modulos de elas cidad incial (al cortar los cables)
Eci
Ep
n ≔ ― = 6.62 :Relación de modulos de elas cidad incial (al los 28 días)
Ec
e = 35 :distancia del C.G de la sección al centroide del cable
2
L
MD ≔ WD ⋅ ―― = 2008800 ⋅ :Momento flector por peso propio
8
2
−Pi ⎛ e ⎞ e ⋅ MD
fcp ≔ ―― ⎜ 1 + ― ⎟ + ――― = −66.66 ―― :Esfuerzo en el hormigón a la distancia
2 2
Ac ⎝ r ⎠ Ix e del cable
Pérdida en acero de pretensar al momento de cortar los cables:
PT ≔ 14514.1 :Fuerza Pi de los cables de Torsión
PT
fcp1 ≔ −2 ⋅ ―― = −6.243 ―― : fcp1 de los cables de Torsión
2
Ac
u ≔ 0.65 :valor promedio especificado por la AASHTO
Lb = 50 : Longitud de bancada
u
Δfpa ≔ Ep ⋅ ―= 260 ――
2
Lb
é ó ó
en lugar de usar la relacion V/S se puede usar A/P mas rapidadmente :
HR ≔ 70 HR: humedad rela va ambiental (supuesta)
−6 Ep ⎛ Ac ⎞
Δfcr ≔ 8.2 ⋅ 10 ⋅ ――⋅ ⎜1 − 0.0236 ⋅ ―― ⎟ ⋅ (100 − HR)
⎝ Pr ⎠
Δfcr = 284.3 ――
2
t ≔ 1825 :dias =(5 años)
0.60
t
Ct ≔ ―――⋅ Cu = 2.12 : Coeficiente de deformación plás ca a la edad de t días
0.60
10 + t
⎛ Ep ⎞
Δfcf ≔ abs ⎜Ct ⋅ ― fcp + fcp1⎟ :Pérdias considerando los cables de
⎝ Ec ⎠ flexón y torsión
Δfcf = 940.52 ――
2
t ≔ t ⋅ 24 = 43800 horas =(5 años)
Δfr = 386.6 ――
2
*sumando todas las perdidas para obtener el total: Esfuerzo inicial de
pretensado
Δfpt ≔ Δfr + Δfcf + Δfcr + Δfpa + Δfpe = 2388 ―― fpi = 14000 ――
2 2
∴ = “cumple rango”
" Rango de perdidas permitido segun el PCI : 1760kg/cm2 y 3520 kg/cm2 "
100 ⋅ Δfpt
expresado en % de fpi : porcentj ≔ ―――― = 17
fpi
CÁLCULO DE DELFEXIONES:
L
―― = 2.5 :Valor elegido de la tabla 5 de la sección 2.7 (Deflexiónes) por ser el
480
menor para luego comparar con el calculado
W ≔ Ac ⋅ γ = 11.16 ―― :Carga debida a peso propio
Perin
Porcj ≔ ―― ⋅ 100 = 5.5 :Pérdidas Instantáneas en % (5‐10)
fpi
2
e = 35 Eci = 282495.13 ―― Ap = 8.322
2
fpi = 14000 ――
2
4
5⋅W⋅L
Δpp ≔ −―――― = −0.61 :Deflexión por peso propio
384 ⋅ Eci ⋅ Ix
2
5 P⋅e⋅L
Δcamber ≔ ― ⋅ ―――= 1.175 :Deflexión por el camber producido
48 Eci ⋅ Ix
METODO DE LOS MULTIPLICADORES PARA ESTIMAR LAS DEFLEXIONES A LARGO PLAZO:
*Para este elemento se analizará con los mul pllicadores C1 sin losa sobre elementos
pretensados, tomados de la tabla 6 del cap tulo 3 sección 3.5.1
Al izar el elemento deflexion:
δi ≔ 1.8 ⋅ Δcamber − abs ⎛⎝1.85 ⋅ Δpp⎞⎠ = 0.98 :Calculado con los coeficientes tomados
de la tabla 6, sección 3.5.1
Final o después de 5 anios: :Calculado con los
δfinal ≔ −abs ⎛⎝2.7 ⋅ Δpp⎞⎠ + 2.45 ⋅ Δcamber − abs ⎛⎝3 ⋅ Δpp⎞⎠ = −0.61 coeficientes tomados
de la tabla 6
Para el 3er termino de esta ecuacion se considera como carga muerta
sobrepueta al peso propio del elemento
Para graficar la deflexión
ΔTot −4 1
C ≔ −―――― = −1.56 ⋅ 10 ― :Constante de la ecuacion y=cx^2+b
2
(−0.5 ⋅ L)
Grafico de la Deflexión de la viga por cables de flexión
5
4.5
4
3.5
3
2.5
2 f (x) ( )
1.5
1
0.5
0
-6 -5 -4 -3 -2 -1 0 1 2 3 4 5 6
x ( )
b ≔ 70 : ancho de sección I
h ≔ 75 : altura de la seción I
L ≔ 12 : Logitud de la viga considerada
tw ≔ 35 : espesor del alma
tf ≔ 15 : espesor del ala/pa n
2
Ac ≔ ⎛⎝2 ⋅ tf ⋅ b⎞⎠ + tw ⋅ ⎛⎝h − 2 ⋅ tf⎞⎠ = 3675
: Ordenada del
b ⋅ tf ⋅ 0.5 ⋅ tf + tw ⋅ ⎛⎝h − 2 ⋅ tf⎞⎠ ⋅ ⎛⎝tf + 0.5 ⋅ ⎛⎝h − 2 ⋅ tf⎞⎠⎞⎠ + b ⋅ tf ⋅ ⎛⎝h − 0.5 ⋅ tf⎞⎠
ŷ ≔ ――――――――――――――――――――― C.G. de la
tw ⋅ ⎛⎝h − 2 ⋅ tf⎞⎠ + 2 ⋅ b ⋅ tf sección
∴ ŷ = 37.5
k1 ≔ h − 2 ⋅ tf
k2 ≔ h − 0.5 ⋅ tf
3 3
tf 2 k1 2 2
Ix ≔ 2 ⋅ b ⋅ ―― + b ⋅ tf ⋅ ⎛⎝0.5 ⋅ tf − ŷ⎞⎠ + tw ⋅ ―― + tw ⋅ k1 ⋅ ⎛⎝tf + 0.5 ⋅ k1 − ŷ⎞⎠ + b ⋅ tf ⋅ (k2 − ŷ)
12 12
4
∴ Ix = 2195156.25
‾‾‾
Ix
r≔ ― = 24.4
Ac
γ ≔ 2400 ―― :Peso especifico del hormigón
3
‾‾‾‾‾‾‾
Ec ≔ 15100 ⋅ f'c ⋅ ――= 302000 ――
2 2
‾‾‾‾‾‾‾‾
Eci ≔ 15100 ⋅ f'ci ⋅ ――= 282495.1 ――
2 2
Tipo de cable u lizado: torones grado 270ksi con a = 1.387cm2
2
∴ A ≔ 1.387 :Area del acero de 0.6 pulgadas (ver tabla 1 de pos de cables )
#cables ≔ 5 :Número de cables para flexión
2
Ap ≔ #cables ⋅ A = 6.935 :Area total de acero de preesfuerzo
e ≔ 31 :Distancia del eje neutro de la sección al centroide del acero de
preesfuerzo
ANÁLISIS DE PÉRDIDAS
1: Perdida por el acortamiento instantáneo del Hormigón
fpi
ε≔― = 0.007 :Deformación unitaria en el cable
Ep
P i ⋅ Lb
δ ≔ ――― = 35 :Deformación total del cable
Ep ⋅ Ap
fc : esfuerzo promedio del hormigon debido a Pi
Pi
εc ≔ ――― = 0.000087 :Deformación unitaria en el hormigón
Ac ⋅ Ec
Ahora se calcula la pérdida del cable:
WD ≔ Ac ⋅ γ = 8.82 ―― :Peso propio por unidad de longitud
Ep
ni ≔ ―― = 7.08 :Relación de modulos de elas cidad incial (al cortar los cables)
Eci
Ep
n≔― = 6.62 :Relación de modulos de elas cidad incial (al los 28 días)
Ec
e = 31 :distancia del C.G de la sección al centroide del cable
2
L
MD ≔ WD ⋅ ―― = 1587600 ⋅ :Momento flector por peso propio
8
2
−Pi ⎛ e ⎞ e ⋅ MD
fcp ≔ ―― ⎜ 1 + ― ⎟ + ――― = −46.5 ―― :Esfuerzo en el hormigón a la distancia
2 2
Ac ⎝ r ⎠ Ix e del cable
Pérdida en acero de pretensar al momento de cortar los cables:
PT ≔ 25895.9 :Fuerza Pi de los cables de Torsión
PT
fcp1 ≔ −2 ⋅ ―― = −14.093 ―― : fcp1 de los cables de Torsión
2
Ac
u ≔ 0.65 :valor promedio especificado por la AASHTO
Lb = 50 : Longitud de bancada
u
Δfpa ≔ Ep ⋅ ―= 260 ――
2
Lb
en lugar de usar la relacion V/S se puede usar A/P mas rapidadmente :
HR ≔ 70 HR: humedad rela va ambiental (supuesta)
−6 Ep ⎛ Ac ⎞
Δfcr ≔ 8.2 ⋅ 10 ⋅ ――⋅ ⎜1 − 0.0236 ⋅ ―― ⎟ ⋅ (100 − HR)
⎝ Pr ⎠
Δfcr = 327.9 ――
2
t ≔ 1825 :dias =(5 años)
0.60
t
Ct ≔ ―――⋅ Cu = 2.12 : Coeficiente de deformación plás ca a la edad de t días
0.60
10 + t
⎛ Ep ⎞
Δfcf ≔ abs ⎜Ct ⋅ ― fcp + fcp1⎟ :Pérdias considerando los cables de
⎝ Ec ⎠ flexón y torsión
Δfcf = 665.82 ――
2
t t 24 43800 h (5 ñ )
t ≔ t ⋅ 24 = 43800 horas =(5 años)
Δfr = 386.6 ――
2
*sumando todas las perdidas para obtener el total: Esfuerzo inicial de
pretensado
Δfpt ≔ Δfr + Δfcf + Δfcr + Δfpa + Δfpe = 2069 ―― fpi = 14000 ――
2 2
∴ = “cumple rango”
" Rango de perdidas permitido segun el PCI : 1760kg/cm2 y 3520 kg/cm2 "
100 ⋅ Δfpt
expresado en % de fpi : porcentj ≔ ―――― = 15
fpi
CÁLCULO DE DELFEXIONES:
L
―― = 2.5 :Valor elegido de la tabla 5 de la sección 2.7 (Deflexiónes) por ser el
480
menor para luego comparar con el calculado
W ≔ Ac ⋅ γ = 8.82 ―― :Carga debida a peso propio
Perin
Porcj ≔ ――⋅ 100 = 4.9 :Pérdidas Instantáneas en % (5‐10)
fpi
2
e = 31 Eci = 282495.13 ―― Ap = 6.935
2
fpi = 14000 ――
2
4
5⋅W⋅L
Δpp ≔ −―――― = −0.38 :Deflexión por peso propio
384 ⋅ Eci ⋅ Ix
2
5 P⋅e⋅L
Δcamber ≔ ― ⋅ ―――= 0.692 :Deflexión por el camber producido
48 Eci ⋅ Ix
METODO DE LOS MULTIPLICADORES PARA ESTIMAR LAS DEFLEXIONES A LARGO PLAZO:
*Para este elemento se analizará con los mul pllicadores C1 sin losa sobre elementos
pretensados, tomados de la tabla 6 del cap tulo 3 sección 3.5.1
Al izar el elemento deflexion:
δi ≔ 1.8 ⋅ Δcamber − abs ⎛⎝1.85 ⋅ Δpp⎞⎠ = 0.54 :Calculado con los coeficientes tomados
de la tabla 6, sección 3.5.1
Final o después de 5 anios: :Calculado con los
δfinal ≔ −abs ⎛⎝2.7 ⋅ Δpp⎞⎠ + 2.45 ⋅ Δcamber − abs ⎛⎝3 ⋅ Δpp⎞⎠ = −0.49 coeficientes tomados
de la tabla 6
Para el 3er termino de esta ecuacion se considera como carga muerta
sobrepueta al peso propio del elemento
Para graficar la deflexión
ΔTot −5 1
C ≔ −―――― = −8.56 ⋅ 10 ― :Constante de la ecuacion y=cx^2+b
2
(−0.5 ⋅ L)
Grafico de la Deflexión de la viga por cables de flexión
5
4.5
4
3.5
3
2.5
2 f (x) ( )
1.5
1
0.5
0
-6 -5 -4 -3 -2 -1 0 1 2 3 4 5 6
x ( )