Hoja de Calculo Reservorio Apv
Hoja de Calculo Reservorio Apv
Hoja de Calculo Reservorio Apv
DATOS
PROYECTO : CONSTRUCCIÓN DE ACERO MUROS
RESERVORIO DE 10 M3 EN EL ACERO VERTICAL = 1/2 Pulg.
SECTOR DE QANCHISPUJIO –
COMITÉ #5 – APV AYUDA MUTUA DIAMETRO = 1.270 Cms.
AREA = 1.267 Cms2.
FECHA JUNIO DEL 2016 PESO = 0.994 Kg/ml
ACERO HORIZONTAL= 3/8 Pulg.
DIAMETRO = 0.953 Cms.
CARACTERISTICAS GEOMETRICAS AREA = 0.713 Cms2.
VOLUMEN RESERVORIO = 10.00 m3 PESO = 0.560 Kg/ml
ALTURA UTIL RESERVORI = 1.35 mts.
LADO UTIL RESERVORIO = 2.75 mts. ACERO LOSA DE TECHO
ESPECIFICACIONES ACERO HORIZONTAL= 1/2 Pulg.
CONCRETO f'c = 210 Kg/cm2 DIAMETRO = 1.270 Cms.
SOBRECARGA EN LOSA = 150 Kg/m2 AREA = 1.267 Cms2.
ACERO fy = 4,200 Kg/cm2 PESO = 0.994 Kg/ml
RESISTENCIA DEL SUELO = 0.90 Kg/cm2 ACERO LOSA DE FONDO
COEF. SISMICO = 0.12 ACERO HORIZONTAL= 1/2 Pulg.
RECUBRIMIENTO r = = 4.00 Cm DIAMETRO = 1.270 Cms.
fs = 2,100 Kg/cm2 AREA = 1.267 Cms2.
fc = 94.5 Kg/cm2 PESO = 0.994 Kg/ml
1.73
1.73
Sc Wc
SL 0.10
A' B'
0.30
WL NIVEL DE AGUA
S1
1.35
Ea
1.03 Wa
A B
S2 0.20
0.10
C D
W2
0.28
0.87
1.04
CALCULOS
W1= Pc x V1 594.00 Kg
W2 = Pc x V2 830.40 Kg
Wa = Pa x Va 1863.00 Kg
WL = Pc x VL 367.20 Kg
Ws = Sc x A 229.50 Kg
S1 = 0,12 x W1 106.92 Kg
S2 = 0,12 x W2 149.47 Kg
SL = 0,12 x WL 66.10 Kg
Ss = 0,12 x Ws 49.57 Kg
Ea = 1,12 x 0,5 x Pa x H12 1530.90 Kg
V = Fh / A 1.17 Kg/cm2
CALCULO DE LA ARMADURA
Mu 976.23 Kg-mts.
d = t1 - r - D/2 10.37 Cms.
AREA DE ACERO
As1 = 85.54 Cms2
As2 = 2.57 Cms2 SE ASUME : 2.57 Cms2
CUANTIA = As / t1 x b 0.0017
As = P x b x t1 2.70 Cms2
ACERO EN LA ZAPATA
P1 3370.896
P2 5452.92
P3 4918.32
P4 8619.55
P5 15425.64
Wu : 4305.56
CALCULO DEL MOMENTO ULTIMO
CUANTIA = As / t1 x b 0.00183
CUANTIA = As / t1 x b 0.00113
CUANTIA MINIMA POR FLEXIO 0.0012 > 0.0011 MAL!! SE ASUME CUANTIA MINIMA P= 0.0012
As = P * t1 * b 1.20 Cms2
0.15 0.30
0.15
1.6 UNIONES
ELECTROSOLDADAS
0.10
2.75
ESCALINES F°G°
VER DETALLE
DETALLE DE ESCALINES
ESPECIFICACIONES TECNICAS
0.15 RESISTENCIA DEL CONCRETO f'c = 210 Kg/cm2
0.10
� � � � � � � � �
� �
0.30
NIVEL DE AGUA
� � 1/2 @ 0.30 �
� �
1.35
� 1/2 @ 0.30
� �
� 1/2 @ 0.25 PENDIENTE DE FONDO 1%
� 3/8 @ 0.30
� �
� � � � � � � � �
0.20
� � � � � � � �
0.075
3.05
2 Ø 3/8
ESPECIFICACIONES TECNICAS
RESISTENCIA DEL CONCRETO f'c = 175 Kg/cm2
3.05
PLANILLA DE ARMADURA RESERVORIO 10 M3
2.99
2.99
1.27
3.39
0.11
0.15
2.90 3/8 6.25 15.20 53.20 11 11
1.53
CAPACIDAD : 10 M3
UCCIÓN DE RESERVORIO
PROYEC.: DE 10 M3 EN EL SECTOR DE QANCHISPUJIO – COMITÉ #5 – APV AYUDA MUTUA
6.09 TARRAJEO INTERIOR CON IMPERMEABILIZANTE 4.00 2.75 1.65 18.15 25.71 m2
1.00 2.75 2.75 7.56 m2
6.10 TARRAJEO EXTERIOR MEZCLA 1:5 4.00 3.05 1.75 21.35 30.65 m2
1.00 3.05 3.05 9.30 m2
6.11 TAPA SANITARIA METALICA 0,60 x 0,60 Mts. 1.00 1.00 1.00 unid
6.12 TUBERIA DE VENTILACION F°G° D= 2" 1.00 1.00 1.00 unid
6.13 PRUEBA HIDRAULICA Y DESINFEC. RESERVORIO 1.00 1.00 1.00 glb
6.14 SUMINISTRO Y COLOCACION DE HIPOCLORADOR 1.00 1.00 1.00 unid
6.15 PINTADO DE MUROS EXTERIORES 4.00 3.05 1.75 21.35 30.65 m2
1.00 3.05 3.05 9.30