Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Hotesa Hidraulicos 05072013-HOJAS IH5

Descargar como pdf o txt
Descargar como pdf o txt
Está en la página 1de 1

0.90 3.

00

0.60 0.15
Parrilla Ø3/8" @ 10 cm.
Concreto 140 Kg/cm2
ASA Ø1/2"

0.0500
0.10 PARED DE
H=0.37m Piso de Concreto Reforzado H=0.43m CARCAMO HUMEDO
NT=874.54 Pendientes hacia cajas parrillas NT=874.54 0.85
H=0.30m Interior Repellado LADRILLO DE OBRA
NF=874.17 proyectadas NF=874.11
C.A.LL. 1 NT=874.54 C.A.LL. 2 C.A.LL. 3 Niples de Ho Go
NF=874.24 PVC Ø6" 100 PSI S =1 % PVC Ø6" 100 PSI S =1 %
Medidor
D= 7.00 MTS. D= 6.00 MTS. V.C.
Adaptador PVC Unión Adaptador PVC

D= 2.22 MTS. S =1 %
PVC Ø6" 100 PSI
0.60
1.70 0.60 2.00
C.A.N. 1 H=0.46m
H=0.40m NT=874.54 C.A.N. 2
NT=874.54 PVC Ø 4" 100 PSI S =1 % D=6.42 MTS. NF=874.08
PVC Ø 3 4" JR 160 PSI NF=874.14

BAN Ø 4" SAP Ø 1/2" PVC Grava TAPADERA


BALL Ø 4" BALL Ø 4"
PVC Ø 3
4" JR 160 PSI H=0.45m 0.60X0.60 0.85
C.A.LL. 4 NT=874.54 Tub. PVC Ø
NF=874.09 Indicado
Losa de Fundacion Ref. No. 3 a.s. @12cms A 0.60 A
Concreto 140 Kg/cm2 Viene de Red
10 ELEVACIÓN
de Distribución

ESTACIONAMIENTO DETALLE DE CAJA 0.60X 0.60m.


0.15
PARA VALVULA Y MEDIDOR
SIN ESCALA
0.15 1.50 1.50 0.15

S =1 % D=10.96 MTS.
N1, 4#4
3.30
9 Tapadera de Concreto EST.#2 @ 0.15

PVC Ø 3 4" JR 160 PSI


ESTACIONAMIENTO Marco de angulo 2X2X1/8"
NPT=0+0.00
Parrilla Ø3/8" @ 10 cm.
Concreto 210 Kg/cm2 PLANTA DE CISTERNA esc. 1:25

S =1 %
0.40
0.49

PVCØ6" 100 PSI


TAPADERA
#3 @ 0.15 LOSA DENSA

PVC Ø 4" 100 PSI

D= 15.55 MTS.
ASA Ø1/2"
0.60X0.60 AMBOS SENTIDOS
CAJA VALVULA LAMINA GALV. e=15 cms
8 0.10
DE CONTROL CANDADO
0.00+0.00 0.15
ESTACIONAMIENTO

PVC Ø 3 4" JR 160 PSI


0.08
0.00-0.15
V1 0.15X0.25, 4#4
Interior Repellado
Niples de Ho Go V.C. V1 EST.#2 @ 0.15
0.75
Adaptador PVC Unión V.C. Adaptador PVC
ESTACIONAMIENTO 0.60 VALVULA DE FLOTADOR
Ø1/2" GALVANIZADA
7 NPT=0+0.00
SAP Ø 1/2" PVC
C.A.N. 3
H=0.57m
NT=874.54 Tub. PVC Ø
NF=873.97 Indicado
BAN Ø 4" Ø1/2" PVC DE MEDIDOR
0.23 0.23 ESCALON Ø5/8" HoGo
ELEVACIÓN A CADA 60CMS REPELLADO
Piso de Concreto Reforzado Y PULIDO
2.25 S1 0.15X0.15, 4#4
Pendientes hacia cajas parrillas
10%

proyectadas 2.40
DETALLE 3 CAJA 0.40 X 0.40m. PARA 2.00 EST.#2 @ 0.15
Piso de Concreto Reforzado VALVULAS DE PVC DE LA RED DE 1.50

Ø3/4" TUBO DE SUCCION A BOMBA


Pendientes hacia cajas parrillas
proyectadas DISTRIBUCIÓN DE AGUA POTABLE
ESC. 1:20
S 1 2 3

RAMPA
ACCESO
CARCAMO HUMEDO
6.5%
NPT=0+0.15 4

7
Losa Densa Repellada y Pulida
8
BALL Ø 4" C.A.LL. 5 0.50 e=15 cms
BALL Ø 4" H=0.61m
18 9
NT=874.54 V1 0.15X0.25, 4#4 PROYECTO. PROPIETARIO:
C.A.LL. 8
H=0.65m
17 10 NF=873.93 0.30 EST.#2 @ 0.15
NT=874.65 16 11 0.40
NF=874.00 15 12

ACCESO A 0.55 #3 @ 0.20


HOTELES SALVADOREÑOS
NPT=0+2.58 NPT=0+2.40
NPT=0+0.00
14 13 ESTACIONAMIENTO EN AMBOS SENTIDOS S.A. DE C.V.
NPT=0-0.20
VALVULA DE CIERRE
Ø34" PVC Y CAJA PICHANCHA OFICINAS
UBICACION:
ADMINISTRATIVAS DE
3.00 CALLE A HUIZUCAR #278, RESIDENCIAL
HOTESA
S =1 % D=26.38 MTS.

3.30 SAN FRANCISCO SUR, ENTRE CALLE "A"


S =8 %

Y CALLE "B", SAN SALVADOR, SAN


PVCØ6" 100 PSI

SALVADOR.
S =8 %

SECCION A-A esc. 1:25


D= 11.27 MTS.

CONTENIDO: PROFESIONALES RESPONSABLES:


PVCØ6" 100 PSI

PVC Ø 4" 100 PSI


PVC Ø 3 4" JR 160 PSI

DETALLE DE CISTERNA DE 12 M3
D= 10.88 MTS.

DISEÑO ARQUITECTONICO:

PLANOS Y DETALLES
HIDRAULICO AGUA POTABLE,
NEGRAS Y LLUVIAS
NLL=873.03

H=0.80m H=0.37m Piso de Concreto Reforzado H=0.43m


C.A.LL. 9
PVCØ8" 100 PSI NLL=873.00 NT=873.50 ESCALAS: DISEÑO ESTRUCTURAL:
NF=872.70 NT=874.54 Pendientes hacia cajas parrillas NT=874.54
D= 13.80 MTS. S =1.0% C.A.LL. 6
H=0.30m INDICADAS
H=0.37m
NT=873.50
NF=874.17 proyectadas NF=874.11
NF=873.13 C.A.LL. 1 NT=874.54 C.A.LL. 2 C.A.LL. 3 FECHA:
NF=874.24 PVC Ø6" 100 PSI S =1 % PVC Ø6" 100 PSI S =1 %
MARZO DE 2013
D= 7.00 MTS. D= 6.00 MTS.

D= 2.22 MTS. S =1 %
PVC Ø6" 100 PSI
PVC Ø 3 4" JR 160 PSI No. DE HOJA:
C.A.N. 1 H=0.46m
H=0.40m
NT=874.54 PVC Ø 4" 100 PSI S =1 % D=6.42 MTS.
NT=874.54 C.A.N. 2
NF=874.08
IH-01
BO

PVC Ø 3 4" JR 160 PSI NF=874.14


M

JR 160 PSI
BE

S =8 %

AREA CONSTRUIDA: AREA DEL TERRENO:


O

PVCØ6" 100 PSI


IS

BAN Ø 4"
TE

SAP Ø 1/2" PVC 420.46 M2 915.18 Mts2=1,309.44Vr2


R
N

2"

BALL Ø 4"
A

BALL Ø 4"
PVC Ø

PVC Ø 3 4" JR 160 PSI H=0.45m


D= 11.27 MTS.

C.A.LL. 4 NT=874.54
NF=874.09

10
I
PS
0
S.

16
S.

JR
2" PVC Ø 4"
1/ C.A.N. 4
Ø PVC Ø 4" 100 PSI
C
PV
PVC Ø 2" S =1 %
H=0.84m
ESTACIONAMIENTO
H=0.87m
NT=874.54 NT=873.00
NF=873.70 NF=872.13
C.A.LL. 7
M
ED DA
AN

S.D.ALL.
ID

I
O

PS PVCØ8" 100 PSI V = 12.0M3


R

0 E D=1.50 MTS.
16 NT VC
JR STE S =1.0% . Ø2" P
1" XI 0 MTS UCCION
L=1.8

D=10.96 MTS.
E S
Ø DE RIA D
C E Q = 51.12 LT/SEG TUBE CASETA PARA BOMBA
PV E R

AMPLIACION PLANTA GENERAL HIDRAULICA


D V = 1.06 M/SEG 1 HP DRENAJE A.LL.
N
LL

RDON
ESCALA 1:50
Q=
=8

A CO
ARGA
71

DESC
15
.6

.0
2

LT
/SE
G

TU ORD
C
BO O
Ø DR
4"
N
PV EN
S =6.66 %D=15.00 MTS.

C AJE
DE D
BO E S
M .D
BA .A
A LL.
PVC Ø 4" 100 PSI

G
SE
T/
A LL. L
.0
BA .A 15
M S.D =
O
B E
D Q
DE E
V C AJ
P N
4" RE
Ø D
B O ON
D
TU OR
C

PLANTA SECCIÓN

TS
CR DETALLE CAJA DE REGISTRO DE AN
N

M
LL

0
.4 ESCALA 1:10
=8

20
73

= G
Lt E
.5

/S
5

NS=873.50 C.A.N. 5 LT
.0
PVC Ø 4" 100 PSI 15
% =
1 Q
=
S
I
PS A LL.
10
0 D BA .A
RE M S.D
4" A BO E
Ø A SE D
DE JE

PLANTA GENERAL HIDRAULICA


C A
PV RI TAR ) C A
E C E PV EN
UB E NT "
4 R
(T ON TE Ø D
C XI S N
E U BO DO
T O R
C

ESCALA 1:100

También podría gustarte