Amit Mor

    Amit Mor

    The present study examined the differences in the lower extremity gait kinematic profile of patients recovering from ankle fracture compared with healthy controls. In addition, we inquired whether the profile would differ among fracture... more
    The present study examined the differences in the lower extremity gait kinematic profile of patients recovering from ankle fracture compared with healthy controls. In addition, we inquired whether the profile would differ among fracture severity groups. A total of 48 patients participated in the present prospective, case-control study. The gait of 24 patients recovering from an ankle fracture injury and 24 healthy matched controls was examined using an inertial measurement unit sensor system. The following gait parameters were evaluated: knee range of motion (ROM) during the swing phase, maximum knee flexion angle during stance, thigh and calf ROM, and stride duration. Statistically significant differences were found between the ankle fracture group and the control group for all parameters. The patients with ankle fracture had a lower knee ROM during swing phase compared with the control group (mean ± standard deviation 43.0° ± 15.5° compared with 66.7° ± 5.1°, respectively; p < ...
    Objectives:Conservative treatments for anterior cruciate ligament (ACL) tears may have just as good an outcome as invasive treatments. These include muscle strengthening and neuromuscular proprioceptive exercises to improve joint... more
    Objectives:Conservative treatments for anterior cruciate ligament (ACL) tears may have just as good an outcome as invasive treatments. These include muscle strengthening and neuromuscular proprioceptive exercises to improve joint stability and restore motion to the knee. The Purpose of the current work presents was to examine the feasibility of a novel non-invasive biomechanical treatment to improve the rehabilitation process following an ACL tear. This is a single case report that presents the effect of this therapy in a patient with a complete ACL rupture who chose not to undergo reconstructive surgery.Methods:A 29-year old female athlete with an acute indirect injury to the knee who chose not to undergo surgery was monitored. Two days after injury the patient began AposTherapy. A unique biomechanical device was specially calibrated to the patient’s feet. The therapy program was initiated, which included carrying out her daily routine while wearing the device. The subject underwen...
    Background Previous studies have shown the effect of a unique therapy with a non-invasive biomechanical foot-worn device (AposTherapy) on Caucasian western population suffering from knee osteoarthritis. The purpose of the current study... more
    Background Previous studies have shown the effect of a unique therapy with a non-invasive biomechanical foot-worn device (AposTherapy) on Caucasian western population suffering from knee osteoarthritis. The purpose of the current study was to evaluate the effect of this therapy on the level of symptoms and gait patterns in a multi-ethnic Singaporean population suffering from knee osteoarthritis. Methods Fifty-eight patients with bilateral medial compartment knee osteoarthritis participated in the study. All patients underwent a computerized gait test and completed two self-assessment questionnaires (WOMAC and SF-36). The biomechanical device was calibrated to each patient, and therapy commenced. Changes in gait patterns and self-assessment questionnaires were reassessed after 3 and 6 months of therapy. Results A significant improvement was seen in all of the gait parameters following 6 months of therapy. Specifically, gait velocity increased by 15.9%, step length increased by 10.3%,...
    Background The purpose of the study was to examine the effect of a foot-worn biomechanical device on the clinical measurements and gait patterns of patients with total hip arthroplasty (THA). Methods Nineteen patients, up to 3 months... more
    Background The purpose of the study was to examine the effect of a foot-worn biomechanical device on the clinical measurements and gait patterns of patients with total hip arthroplasty (THA). Methods Nineteen patients, up to 3 months post-THA, were enrolled to the study. Patients underwent a computerized gait analysis to calculate spatiotemporal parameters and completed the Western Ontario and McMaster Universities osteoarthritis index and the SF-36 health survey. Patients then began therapy with a non-invasive foot-worn biomechanical device coupled with a treatment methodology (AposTherapy). Patients received exercise guidelines and used the device daily during their regular activities at their own environment. Follow-up examinations were conducted after 4, 12, and 26 weeks of therapy. Repeated measures ANOVA was used to evaluate changes over time. The clinical significance of the treatment effect was evaluated by computing the Cohen's effect sizes (ES statistic). Results After...
    The purpose of the study was to investigate the changes in gait patterns and clinical measurements following treatment with a novel biomechanical device on patients with knee osteoarthritis. Forty six patients with bilateral knee... more
    The purpose of the study was to investigate the changes in gait patterns and clinical measurements following treatment with a novel biomechanical device on patients with knee osteoarthritis. Forty six patients with bilateral knee osteoarthritis were analyzed. Patients completed a gait test, Western Ontario and McMaster Osteoarthritis Index (WOMAC) questionnaire and SF-36 Health Survey at baseline and after 12 weeks. The biomechanical device was individually calibrated to each patient at baseline to allow training under reduced pain. Gait velocity, step length and single limb support improved significantly and toe out angle decreased significantly (10%, 6%, 1% and 2%, respectively). WOMAC-Pain and WOMAC-Function significantly decreased (26% and 34%, respectively), and SF-36 score significantly increased following the 12 weeks of treatment. Our results suggest an overall improvement in the gait patterns, level of pain and level of function of patients with knee osteoarthritis following 12 weeks of treatment with the novel biomechanical device.
    Background The purpose of this study was to examine the differences in gait profile between patients with knee osteoarthritis (OA) and healthy control and to create motion characteristics that will differentiate between them. Methods... more
    Background The purpose of this study was to examine the differences in gait profile between patients with knee osteoarthritis (OA) and healthy control and to create motion characteristics that will differentiate between them. Methods Twenty three patients diagnosed with knee OA and 21 healthy matched controls underwent a gait test using a sensor system (gaitWALK). Gait parameters evaluated were: stride duration, knee flexion range of motion (ROM) in swing and stance. T-Test was used to evaluate significant differences between groups (P < 0.05). Results Patients with knee OA had significant lower knee flexion ROM (10.3° ± 4.0°) during stance than matched controls (18.0° ± 4.0°) (p < 0.001). Patients with knee OA had significant lower knee flexion ROM (54.8° ± 5.5°) during swing than matched controls (61.2° ± 6.1) (p = 0.003). Patients with knee OA also had longer stride duration (1.12 s ± 0.09 s) than matched controls (1.06 s ± 0.11 s), but this was not statistically significan...