Background: Personalized dosimetry in targeted radiopharmaceutical therapy provides a methodology... more Background: Personalized dosimetry in targeted radiopharmaceutical therapy provides a methodology to estimate the dose for each patient. Dosimetry can guide the amount of administered activity to patients maximizing the radiation dose to the tumor without causing toxicity in healthy organs. Currently, the methodology of the Committee on Medical Internal Radiation Dose (MIRD) to estimate the radiation dose involves imaging at multiple timepoints over a period of several days, which is not always feasible or practical.
Background Prostate specific membrane antigen (PSMA) PET images have shown superior performance i... more Background Prostate specific membrane antigen (PSMA) PET images have shown superior performance in detecting metastatic prostate cancers. Relative to [18F]FDG PET images, PSMA PET images tend to visualize significantly higher-contrast focal lesions. We aim to evaluate segmentation and reconstruction algorithms in this emerging context. Specifically, Bayesian or maximum a posteriori (MAP) image reconstruction, compared to standard OSEM reconstruction, has received significant interest for its potential to reach convergence with minimal noise amplifications. However, few phantom studies have evaluated the quantitative accuracy of such reconstructions for high contrast, small lesions (sub-10mm) that are typically observed in PSMA images. In this study, we cast 3mm-16mm spheres using epoxy resin infused with a long half-life positron emitter (sodium-22; 22Na) to simulate prostate cancer metastasis. The anthropomorphic Probe-IQ phantom, which features a liver, bladder, lungs, and ureters...
Purpose Respiratory motion during positron emission tomography (PET) scans can be a major detrime... more Purpose Respiratory motion during positron emission tomography (PET) scans can be a major detriment to image quality in oncological imaging, leading to loss of quantification accuracy and false negative findings. The impact of motion on lesion quantification and detectability can be assessed using anthropomorphic phantoms with realistic anatomy representation and motion modelling. In this work we design and build such a phantom, with careful consideration of system requirements and detailed force analysis.Methods: We start from a previously-developed anatomically-accurate shell of a human torso and add elastic lungs with a highly controllable actuation mechanism which replicates the physics of breathing. The space outside the lungs is filled with a radioactive water solution. To maintain anatomical accuracy in the torso and realistic gamma ray attenuation, all motion mechanisms and actuators are positioned outside of the phantom compartment. The actuation mechanism can produce a ple...
Abstract The commissioning and benchmark of a Monte Carlo (MC) model of the 6‐MV Brainlab‐Mitsubi... more Abstract The commissioning and benchmark of a Monte Carlo (MC) model of the 6‐MV Brainlab‐Mitsubishi Vero4DRT linear accelerator for the purpose of quality assurance of clinical dynamic wave arc (DWA) treatment plans is reported. Open‐source MC applications based on EGSnrc particle transport codes are used to simulate the medical linear accelerator head components. Complex radiotherapy irradiations can be simulated in a single MC run using a shared library format combined with BEAMnrc “source20.” Electron energy tuning is achieved by comparing measured vs simulated percentage depth doses (PDDs) for MLC‐defined field sizes in a water phantom. Electron spot size tuning is achieved by comparing measured and simulated inplane and crossplane beam profiles. DWA treatment plans generated from RayStation (RaySearch) treatment planning system (TPS) are simulated on voxelized (2.5 mm3) patient CT datasets. Planning target volume (PTV) and organs at risk (OAR) dose–volume histograms (DVHs) are compared to TPS‐calculated doses for clinically deliverable dynamic volumetric modulated arc therapy (VMAT) trajectories. MC simulations with an electron beam energy of 5.9 MeV and spot size FWHM of 1.9 mm had the closest agreement with measurement. DWA beam deliveries simulated on patient CT datasets results in DVH agreement with TPS‐calculated doses. PTV coverage agreed within 0.1% and OAR max doses (to 0.035 cc volume) agreed within 1 Gy. This MC model can be used as an independent dose calculation from the TPS and as a quality assurance tool for complex, dynamic radiotherapy treatment deliveries. Full patient CT treatment simulations are performed in a single Monte Carlo run in 23 min. Simulations are run in parallel using the Condor High‐Throughput Computing software1 on a cluster of eight servers. Each server has two physical processors (Intel Xeon CPU E5‐2650 0 @2.00 GHz), with 8 cores per CPU and two threads per core for 256 calculation nodes.
PURPOSE Respiratory motion during positron emission tomography (PET) scans can be a major detrime... more PURPOSE Respiratory motion during positron emission tomography (PET) scans can be a major detriment to image quality in oncological imaging. The impact of motion on lesion quantification and detectability can be assessed using phantoms with realistic anatomy representation and motion modeling. In this work we develop an anthropomorphic phantom for PET imaging that combines anatomic fidelity and a realistic breathing mechanism with deformable lungs. METHODS We start from a previously-developed anatomically-accurate but static phantom of a human torso, and add elastic lungs with a highly controllable actuation mechanism which replicates the physics of breathing. The space outside the lungs is filled with a radioactive water solution. To maintain anatomical accuracy and realistic gamma ray attenuation in the torso, all motion mechanisms and actuators are positioned outside of the phantom compartment. The actuation mechanism can produce custom respiratory waveforms with breathing rates up to 25 breaths per minute and tidal volumes up to 1200mL. RESULTS Several tests were performed to validate the performance of the phantom assembly, in which the phantom was filled with water and given respiratory waveforms to execute. All parts demonstrated expected performance. Force requirements were not exceeded and no leaks were detected, although continued use of the phantom is required to evaluate wear. The motion of the lungs was determined to be within a reasonable realistic range. CONCLUSIONS The full mechanical design is described in this paper, as well as a software application with graphical user interface which was developed to plan and visualize respiratory patterns. Both are available online as open source files. The developed phantom will facilitate future work in evaluating the impact of respiratory motion on lesion quantification and detectability in clinical practice.
Purpose Respiratory motion during positron emission tomography (PET) scans can be a major detrime... more Purpose Respiratory motion during positron emission tomography (PET) scans can be a major detriment to image quality in oncological imaging, leading to loss of quantification accuracy and false negative findings. The impact of motion on lesion quantification and detectability can be assessed using anthropomorphic phantoms with realistic anatomy representation and motion modelling. In this work we design and build such a phantom, with careful consideration of system requirements and detailed force analysis.Methods: We start from a previously-developed anatomically-accurate shell of a human torso and add elastic lungs with a highly controllable actuation mechanism which replicates the physics of breathing. The space outside the lungs is filled with a radioactive water solution. To maintain anatomical accuracy in the torso and realistic gamma ray attenuation, all motion mechanisms and actuators are positioned outside of the phantom compartment. The actuation mechanism can produce a ple...
The aim of the present experiment was to study the transmission of sound through a building by me... more The aim of the present experiment was to study the transmission of sound through a building by means of replicating a small-scale model of a floor and ceiling apparatus. Therefore, the relationship between input sine wave frequency and sound intensity through a closed apparatus was analyzed. The sound absorbance of various sound insulating materials was compared, and resonance properties of the apparatus was also considered. Sound intensity trends were investigated for frequencies within the human hearing range (up to the order of magnitude of 10,000 Hz), and different soundproofing material types (porous absorbers and resonators) were compared. It appears that the input sound wavelength (relative to the container size), as well as sound absorption coefficient were both major factors in transmitted sound's intensity. Porous absorbers were found to be the most robust material type at both resonance and non-resonance modes, and the optimal soundproofing material was the stone wool insulator (Material 2).
Background: Personalized dosimetry in targeted radiopharmaceutical therapy provides a methodology... more Background: Personalized dosimetry in targeted radiopharmaceutical therapy provides a methodology to estimate the dose for each patient. Dosimetry can guide the amount of administered activity to patients maximizing the radiation dose to the tumor without causing toxicity in healthy organs. Currently, the methodology of the Committee on Medical Internal Radiation Dose (MIRD) to estimate the radiation dose involves imaging at multiple timepoints over a period of several days, which is not always feasible or practical.
Background Prostate specific membrane antigen (PSMA) PET images have shown superior performance i... more Background Prostate specific membrane antigen (PSMA) PET images have shown superior performance in detecting metastatic prostate cancers. Relative to [18F]FDG PET images, PSMA PET images tend to visualize significantly higher-contrast focal lesions. We aim to evaluate segmentation and reconstruction algorithms in this emerging context. Specifically, Bayesian or maximum a posteriori (MAP) image reconstruction, compared to standard OSEM reconstruction, has received significant interest for its potential to reach convergence with minimal noise amplifications. However, few phantom studies have evaluated the quantitative accuracy of such reconstructions for high contrast, small lesions (sub-10mm) that are typically observed in PSMA images. In this study, we cast 3mm-16mm spheres using epoxy resin infused with a long half-life positron emitter (sodium-22; 22Na) to simulate prostate cancer metastasis. The anthropomorphic Probe-IQ phantom, which features a liver, bladder, lungs, and ureters...
Purpose Respiratory motion during positron emission tomography (PET) scans can be a major detrime... more Purpose Respiratory motion during positron emission tomography (PET) scans can be a major detriment to image quality in oncological imaging, leading to loss of quantification accuracy and false negative findings. The impact of motion on lesion quantification and detectability can be assessed using anthropomorphic phantoms with realistic anatomy representation and motion modelling. In this work we design and build such a phantom, with careful consideration of system requirements and detailed force analysis.Methods: We start from a previously-developed anatomically-accurate shell of a human torso and add elastic lungs with a highly controllable actuation mechanism which replicates the physics of breathing. The space outside the lungs is filled with a radioactive water solution. To maintain anatomical accuracy in the torso and realistic gamma ray attenuation, all motion mechanisms and actuators are positioned outside of the phantom compartment. The actuation mechanism can produce a ple...
Abstract The commissioning and benchmark of a Monte Carlo (MC) model of the 6‐MV Brainlab‐Mitsubi... more Abstract The commissioning and benchmark of a Monte Carlo (MC) model of the 6‐MV Brainlab‐Mitsubishi Vero4DRT linear accelerator for the purpose of quality assurance of clinical dynamic wave arc (DWA) treatment plans is reported. Open‐source MC applications based on EGSnrc particle transport codes are used to simulate the medical linear accelerator head components. Complex radiotherapy irradiations can be simulated in a single MC run using a shared library format combined with BEAMnrc “source20.” Electron energy tuning is achieved by comparing measured vs simulated percentage depth doses (PDDs) for MLC‐defined field sizes in a water phantom. Electron spot size tuning is achieved by comparing measured and simulated inplane and crossplane beam profiles. DWA treatment plans generated from RayStation (RaySearch) treatment planning system (TPS) are simulated on voxelized (2.5 mm3) patient CT datasets. Planning target volume (PTV) and organs at risk (OAR) dose–volume histograms (DVHs) are compared to TPS‐calculated doses for clinically deliverable dynamic volumetric modulated arc therapy (VMAT) trajectories. MC simulations with an electron beam energy of 5.9 MeV and spot size FWHM of 1.9 mm had the closest agreement with measurement. DWA beam deliveries simulated on patient CT datasets results in DVH agreement with TPS‐calculated doses. PTV coverage agreed within 0.1% and OAR max doses (to 0.035 cc volume) agreed within 1 Gy. This MC model can be used as an independent dose calculation from the TPS and as a quality assurance tool for complex, dynamic radiotherapy treatment deliveries. Full patient CT treatment simulations are performed in a single Monte Carlo run in 23 min. Simulations are run in parallel using the Condor High‐Throughput Computing software1 on a cluster of eight servers. Each server has two physical processors (Intel Xeon CPU E5‐2650 0 @2.00 GHz), with 8 cores per CPU and two threads per core for 256 calculation nodes.
PURPOSE Respiratory motion during positron emission tomography (PET) scans can be a major detrime... more PURPOSE Respiratory motion during positron emission tomography (PET) scans can be a major detriment to image quality in oncological imaging. The impact of motion on lesion quantification and detectability can be assessed using phantoms with realistic anatomy representation and motion modeling. In this work we develop an anthropomorphic phantom for PET imaging that combines anatomic fidelity and a realistic breathing mechanism with deformable lungs. METHODS We start from a previously-developed anatomically-accurate but static phantom of a human torso, and add elastic lungs with a highly controllable actuation mechanism which replicates the physics of breathing. The space outside the lungs is filled with a radioactive water solution. To maintain anatomical accuracy and realistic gamma ray attenuation in the torso, all motion mechanisms and actuators are positioned outside of the phantom compartment. The actuation mechanism can produce custom respiratory waveforms with breathing rates up to 25 breaths per minute and tidal volumes up to 1200mL. RESULTS Several tests were performed to validate the performance of the phantom assembly, in which the phantom was filled with water and given respiratory waveforms to execute. All parts demonstrated expected performance. Force requirements were not exceeded and no leaks were detected, although continued use of the phantom is required to evaluate wear. The motion of the lungs was determined to be within a reasonable realistic range. CONCLUSIONS The full mechanical design is described in this paper, as well as a software application with graphical user interface which was developed to plan and visualize respiratory patterns. Both are available online as open source files. The developed phantom will facilitate future work in evaluating the impact of respiratory motion on lesion quantification and detectability in clinical practice.
Purpose Respiratory motion during positron emission tomography (PET) scans can be a major detrime... more Purpose Respiratory motion during positron emission tomography (PET) scans can be a major detriment to image quality in oncological imaging, leading to loss of quantification accuracy and false negative findings. The impact of motion on lesion quantification and detectability can be assessed using anthropomorphic phantoms with realistic anatomy representation and motion modelling. In this work we design and build such a phantom, with careful consideration of system requirements and detailed force analysis.Methods: We start from a previously-developed anatomically-accurate shell of a human torso and add elastic lungs with a highly controllable actuation mechanism which replicates the physics of breathing. The space outside the lungs is filled with a radioactive water solution. To maintain anatomical accuracy in the torso and realistic gamma ray attenuation, all motion mechanisms and actuators are positioned outside of the phantom compartment. The actuation mechanism can produce a ple...
The aim of the present experiment was to study the transmission of sound through a building by me... more The aim of the present experiment was to study the transmission of sound through a building by means of replicating a small-scale model of a floor and ceiling apparatus. Therefore, the relationship between input sine wave frequency and sound intensity through a closed apparatus was analyzed. The sound absorbance of various sound insulating materials was compared, and resonance properties of the apparatus was also considered. Sound intensity trends were investigated for frequencies within the human hearing range (up to the order of magnitude of 10,000 Hz), and different soundproofing material types (porous absorbers and resonators) were compared. It appears that the input sound wavelength (relative to the container size), as well as sound absorption coefficient were both major factors in transmitted sound's intensity. Porous absorbers were found to be the most robust material type at both resonance and non-resonance modes, and the optimal soundproofing material was the stone wool insulator (Material 2).