The aim was to assess the knowledge and attitudes of specialists (SP) and general dental practitioners (GDP) toward cement-retained restoration (CRR), screw-retained restoration (SRR) and implant restorations in Saudi Arabia.... more
The aim was to assess the knowledge and attitudes of specialists (SP) and general dental practitioners (GDP) toward cement-retained restoration (CRR), screw-retained restoration (SRR) and implant restorations in Saudi Arabia. Self-designed-structured questionnaires were distributed between SP and GDP by hand and through E-mails. Opinion of dentists regarding factors vital in selection of CRR and SRR was enquired. Factors included esthetics, retrievability, retention, passive fit, fracture resistance, tissue health, cost-effectiveness, fabrication ease, and required expertise. Participants also graded significance of treatment-planning factors for implant-retained prosthesis. Analysis of comparative response frequencies and significance grades was done using the Chi-square and independent t-test. Of 552 respondents, 64% were SP and 36% were GDP with overall response rate of 67%. About 75% of SP and 80% of GDP used SRR in <50% and <25% of their implant practice respectively. The...
The preservation of esthetics and occlusal vertical dimension is critical in patients with existing full-arch tooth-retained fixed prostheses. This clinical report describes the provision of a maxillary immediate complete denture in a... more
The preservation of esthetics and occlusal vertical dimension is critical in patients with existing full-arch tooth-retained fixed prostheses. This clinical report describes the provision of a maxillary immediate complete denture in a patient with a maxillary full-arch fixed dental prosthesis over nonviable teeth. The existing fixed dental prosthesis was used in the fabrication of the maxillary immediate complete denture to preserve esthetics. The technique involved recording and preservation of the occlusal vertical dimension and occlusion of the existing prosthesis. The technique is simple, quick, cost-effective and less challenging clinically and technically.
Objective: The aim of this in vitro research study was to evaluate the vertical marginal discrepancies of zirconia (Zr) cores fabricated by five different computer-aided design and manufacturing (CAD/CAM) systems using a digital... more
Objective: The aim of this in vitro research study was to evaluate the vertical marginal discrepancies of zirconia (Zr) cores fabricated by five different computer-aided design and manufacturing (CAD/CAM) systems using a digital microscope. Materials and methods: A total of 60 specimens were prepared and randomly divided into five groups (n=12 each) using the following systems: Ceramill Motion 2 (CM, Amanngirrbach, Germany); Weiland (WI, Ivoclar Vivadent, USA); Cerec (CS, Sirona Dental, USA); Zirkonzahn (ZZ, Gmbh Bruneck, Italy) and Cad4dent (CD, Canada). The specimens were numbered and the vertical marginal discrepancies were evaluated with a digital microscope at 50× magnification. Results: A one-way analysis of variance showed a statistically significant difference (p=0.002) between the groups. The CM group exhibited the lowest values for the marginal gaps (31.30±15.12 μm), while the ZZ group exhibited the highest values for the marginal gaps (44.83±28.76 μm) compared to other gr...
Dental implants are frequently used to support fixed or removable dental prostheses to replace missing teeth. The clinical success of titanium dental implants is owed to the exceptional biocompatibility and osseointegration with the bone.... more
Dental implants are frequently used to support fixed or removable dental prostheses to replace missing teeth. The clinical success of titanium dental implants is owed to the exceptional biocompatibility and osseointegration with the bone. Therefore, the enhanced therapeutic effectiveness of dental implants had always been preferred. Several concepts for implant coating and local drug delivery had been developed during the last decades. A drug is generally released by diffusion-controlled, solvent-controlled, and chemical controlled methods. Although a range of surface modifications and coatings (antimicrobial, bioactive, therapeutic drugs) have been explored for dental implants, it is still a long way from designing sophisticated therapeutic implant surfaces to achieve the specific needs of dental patients. The present article reviews various interdisciplinary aspects of surface coatings on dental implants from the perspectives of biomaterials, coatings, drug release, and related th...
Objectives: The aim of this study was to investigate and compare the level of halitosis in patients with/without fixed crowns and in addition the influence of various crown parameters on halitosis was also explored. Methods: In total, 96... more
Objectives: The aim of this study was to investigate and compare the level of halitosis in patients with/without fixed crowns and in addition the influence of various crown parameters on halitosis was also explored. Methods: In total, 96 subjects (fixed crowns = 52; no crowns = 44) participated in the study. The levels volatile sulphur compounds (VSCs) of hydrogen sulphide (H2S), methyl mercaptan (CH3SH), and dimethyl sulphide (CH3SCH3) were evaluated with breath samples using gas chromatography and used for classification as presence or absence of halitosis. The periodontal clinical parameters for all the participants as well as the crown parameters for participants with fixed crowns were also evaluated. Cross tabulation, Chi-square test, and one-way analysis of variance tests were used for the statistical analysis and comparisons. Results: Breath samples revealed, 50 (52.1%) participants were suffering from halitosis. Out of VSCs, the level of CH3SCH3 (62.5%) was found to be the m...
The aim of the present study was to investigate the shear bond strength of five different repair methods and adhesive systems for zirconia (Zr) cores layered with feldspathic porcelain. Seventy-five Zr specimens (10 × 10 × 4 mm3) were... more
The aim of the present study was to investigate the shear bond strength of five different repair methods and adhesive systems for zirconia (Zr) cores layered with feldspathic porcelain. Seventy-five Zr specimens (10 × 10 × 4 mm3) were prepared, sintered, layered with 2 × 10 × 10 mm3 of feldspathic porcelain, and fired. The ceramic was fractured, and the load recorded using a shear-bond test. Specimens were thermocycled and randomly divided into 5 groups (n = 15/group) based on the repair methods. Composite repair blocks with similar dimensions to the layered ceramic (2 × 10 × 10 mm3) were built according to each repair method. Shear bond strength testing of the specimens with composite built up was carried out using a universal testing machine (Instron®5960, Massachusetts, USA). The shear bond strengths of the adhesive interface between repaired composite and the Zr were recorded for all the test groups. The fractured specimens’ surfaces were examined under a scanning electron micro...
The fracture resistance of computer-aided designing and computer-aided manufacturing CAD/CAM fabricated implant-supported cantilever zirconia frameworks (ISCZFs) is affected by the size/dimension and the micro cracks produced from diamond... more
The fracture resistance of computer-aided designing and computer-aided manufacturing CAD/CAM fabricated implant-supported cantilever zirconia frameworks (ISCZFs) is affected by the size/dimension and the micro cracks produced from diamond burs during the milling process. The present in vitro study investigated the fracture load for different cross-sectional dimensions of connector sites of implant-supported cantilever zirconia frameworks (ISCZFs) with different cantilever lengths (load point). A total of 48 ISCZFs (Cercon, Degudent; Dentsply, Deutschland, Germany) were fabricated by CAD/CAM and divided into four groups based on cantilever length and reinforcement of distal-abutment: Group A: 9 mm cantilever; Group B: 9 mm cantilever with reinforced distal-abutment; Group C: 12 mm cantilever; Group D: 12 mm cantilever with reinforced distal-abutment (n = 12). The ISCZFs were loaded using a universal testing machine for recording the fracture load. Descriptive statistics, ANOVA, and T...
Objective. Analyzing and comparing the fit and accuracy of removable partial denture (RPDs) frameworks fabricated with CAD/CAM and rapid prototyping methods with conventional techniques. Materials and Methods. The present systematic... more
Objective. Analyzing and comparing the fit and accuracy of removable partial denture (RPDs) frameworks fabricated with CAD/CAM and rapid prototyping methods with conventional techniques. Materials and Methods. The present systematic review was carried out according to PRISMA guidelines. The search was carried out on PubMed/MEDLINE, Cochrane collaboration, Science direct, and Scopus scientific engines using selected MeSH keywords. The articles fulfilling the predefined selection criteria based on the fit and accuracy of removable partial denture (RPD) frameworks constructed from digital workflow (CAD/CAM; rapid prototyping) and conventional techniques were included. Results. Nine full-text articles comprising 6 in vitro and 3 in vivo studies were included in this review. The digital RPDs were fabricated in all articles by CAD/CAM selective laser sintering and selective laser melting techniques. The articles that have used CAD/CAM and rapid prototyping technique demonstrated better fi...
Optimal bond strength between the prefabricated post/dowel to the surrounding dentin is essential. The present study aimed to analyze and compare the effect of three different cement film thicknesses on the pull-out bond strength of three... more
Optimal bond strength between the prefabricated post/dowel to the surrounding dentin is essential. The present study aimed to analyze and compare the effect of three different cement film thicknesses on the pull-out bond strength of three different prefabricated post systems. Extracted natural teeth (N = 90) with similar root dimensions were acquired. Teeth were mounted in resin blocks, endodontically treated, sectioned at cemento-enamel junction, divided into three groups (A: Parapost Fiber Lux plus; B: 3M ESPE Relyx fiber post; and C: Parapost XP), and stored. Uniform post spaces were prepared for the groups (A and C: Length = 8 mm, Width = 1.5 mm; B: Length = 8 mm, Width = 1.6 mm). Each group (N = 30) was further subdivided into three subgroups (n = 10) based on the size (4, 5, and 6) of the post and cemented with resin cement (MultiLink-N, Ivoclar Vivadent). After thermocycling, the specimens were subjected to a pull-out test using a universal testing machine, and tensile force ...
Background: The purpose was to compare the fracture resistance and the mode of failure of different contemporary restorative materials to restore implant supported, cement-retained mandibular molars. Methods: Two 5 × 10 mm titanium dental... more
Background: The purpose was to compare the fracture resistance and the mode of failure of different contemporary restorative materials to restore implant supported, cement-retained mandibular molars. Methods: Two 5 × 10 mm titanium dental implants were mounted in resin blocks and prefabricated titanium and zirconia abutments were connected to each implant. Each implant received forty crowns resembling mandibular first molars. The specimens were divided into four groups (n = 10/group) for each abutment according to the type of material; Group A: porcelain fused to metal crowns; Group B: monolithic zirconia crowns; Group C: zirconia coping with ceramic veneer; Group D: all ceramic lithium disilicate crowns. Specimens were cemented to the abutments, mounted into a universal testing machine, and vertical static load was applied at a speed of 1 mm/min. The test stopped at signs of visual/audible fracture/chipping. Fracture resistance values were analyzed using ANOVA and Tukey’s tests (α ...
The aim is to compare the use of Cyanoacrylate adhesives (CAA) to the conventional suturing technique in terms of free gingival grafts (FGG) stability and healing in lower anterior and premolar regions. A split mouth design was initiated... more
The aim is to compare the use of Cyanoacrylate adhesives (CAA) to the conventional suturing technique in terms of free gingival grafts (FGG) stability and healing in lower anterior and premolar regions. A split mouth design was initiated on 22 participants. Each side (from 2nd premolar to central incisor) was randomized to either the control or test groups. In the control group, sutures were used to stabilize the FGG, while, in the test group, the FGG was stabilized with butyl-cyanoacrylate. Full-periodontal clinical parameters were employed to assess the periodontal health. FGG-related parameters assessed included the keratinized tissue width (KTW), gingival tissue thickness (GTT), FGG shrinkage% and pain using the VAS score. No significant differences in the mean values of the KTW nor FGG shrinkage% across six time points (p < 0.05) were observed, whereas highly significant differences in the mean values of GTT across six time points (F = 3.32; p = 0.008) were observed. The use...
Background: To identify and compare the shade variations of various commonly used esthetic dental ceramics by calculating their total-color-difference (ΔE) and translucency parameter (TP) using a spectrophotometer. Methods: In total, 165... more
Background: To identify and compare the shade variations of various commonly used esthetic dental ceramics by calculating their total-color-difference (ΔE) and translucency parameter (TP) using a spectrophotometer. Methods: In total, 165 disc specimens from three shades (A1, B1, and C1) of five ceramic materials (N = 55/shade; n = 11/ceramic material group) were prepared (Metal-ceramic (MC), IPS e.max press (Emax-P), IPS e.max layer (Emax-L), Layered Zirconia (Zr-L) and Monolithic zirconia (Zr-M)). With a spectrophotometer, the L* a* b* values were obtained. Total color differences (ΔE = [(ΔL*)2 + (Δa*)2 + (Δb*)2]1/2) and translucency parameter (TP = [(L*B − L*W)2 + (a*B − a*W)2 + (b*B – b*W)2]1/2) were calculated. The statistical tests included ANOVA and Post hoc Tukey’s analysis (p < 0.05). Results: Significant differences (p = 0.000) were found between the groups for ΔE. Highest ΔE (A1) were found for Zr-L (80.18 ± 20) and lowest for Zr-M (62.97 ± 1.28). For B1, highest ΔE val...
The aim of this in-vivo study was to evaluate/compare the clinical periodontal parameters in patients with true combined endo-perio lesions (EPL), treated with gutta-percha (GP) and mineral trioxide (MTA) as an obturation material alone... more
The aim of this in-vivo study was to evaluate/compare the clinical periodontal parameters in patients with true combined endo-perio lesions (EPL), treated with gutta-percha (GP) and mineral trioxide (MTA) as an obturation material alone and with addition of bone grafting in such lesions. 120 Saudi patients (mean age = 41yrs) diagnosed with true combined EPL participated in this study. Group I (control group, n = 30) was treated with conventional endodontic treatment using GP for obturation. Group II (n = 30) was treated with conventional endodontic treatment using MTA for obturation. Group III (n = 30) was treated with conventional endodontic treatment using GP for obturation + grafting procedure to fill the bony defect. Group IV (n = 30) was treated with conventional endodontic treatment using MTA for obturation + grafting procedure to fill the bony defect. Clinical parameters (Pocket depth (PD); Clinical attachment loss (CAL); keratinized tissue width (KTW); gingival phenotype (G....