The city of Mumbai, India with a population of 15 million discharges about 2225 MLD of domestic wastewater after partial treatment to adjoining marine water body. Under the Mumbai Sewage Disposal Project Scheme, sewage is being disposed... more
The city of Mumbai, India with a population of 15 million discharges about 2225 MLD of domestic wastewater after partial treatment to adjoining marine water body. Under the Mumbai Sewage Disposal Project Scheme, sewage is being disposed to the west coast at Worli and Bandra through 3.4 kms long submarine outfalls. A field study was conducted at recently commissioned outfall diffuser location at Worli, at the onset of neap flood tide to study the dispersion patterns and measure the far field dilutions using radio and dye tracers. Estimated dilutions using different tracers were compared with outputs from an empirical model (Brooks) and a 2D numerical model (DIVAST). Validation using parameters such as BOD and FC, indicated a good match for BOD in near field compared to FC. The radiotracer 82Br and Rhodamine WT generally gave good correlation with Brooks' and DIVAST models for nearfield, however at further distances predictions were not accurate.
The city of Mumbai, India with a population of 15 million discharges about 2225 MLD of domestic wastewater after partial treatment to adjoining marine water body. Under the Mumbai Sewage Disposal Project Scheme, sewage is being disposed... more
The city of Mumbai, India with a population of 15 million discharges about 2225 MLD of domestic wastewater after partial treatment to adjoining marine water body. Under the Mumbai Sewage Disposal Project Scheme, sewage is being disposed to the west coast at Worli and Bandra through 3.4 kms long submarine outfalls. A field study was conducted at recently commissioned outfall diffuser location at Worli, at the onset of neap flood tide to study the dispersion patterns and measure the far field dilutions using radio and dye tracers. Estimated dilutions using different tracers were compared with outputs from an empirical model (Brooks) and a 2D numerical model (DIVAST). Validation using parameters such as BOD and FC, indicated a good match for BOD in near field compared to FC. The radiotracer 82Br and Rhodamine WT generally gave good correlation with Brooks' and DIVAST models for nearfield, however at further distances predictions were not accurate.
Unlike urban and semi-urban settlements where the potable water is supplied through a water treatment plant and a distribution network, in rural low-income settings, the provision of the water treatment plant for all villages is not... more
Unlike urban and semi-urban settlements where the potable water is supplied through a water treatment plant and a distribution network, in rural low-income settings, the provision of the water treatment plant for all villages is not feasible for a developing country like India. The most affordable and reliable way to provide clean drinking water is treatment at the consumer end. This research is aimed to assess occurrence of water-borne diseases based on personal hygiene and quality of drinking water source. Of the households, 4,237 in 15 selected villages were surveyed for personal hygiene using a questionnaire. Water samples were collected from all major water sources in the villages and analyzed for chemical and bacteriological properties. For water and personal hygiene, quality indices were calculated, and a mathematical model was developed using multiple linear regression analysis. The regression concluded that personal hygiene has a more significant effect on the occurrence of...
Unlike urban and semi-urban settlements where the potable water is supplied through a water treatment plant and a distribution network, in rural low-income settings, the provision of the water treatment plant for all villages is not... more
Unlike urban and semi-urban settlements where the potable water is supplied through a water treatment plant and a distribution network, in rural low-income settings, the provision of the water treatment plant for all villages is not feasible for a developing country like India. The most affordable and reliable way to provide clean drinking water is treatment at the consumer end. This research is aimed to assess occurrence of water-borne diseases based on personal hygiene and quality of drinking water source. Of the households, 4,237 in 15 selected villages were surveyed for personal hygiene using a questionnaire. Water samples were collected from all major water sources in the villages and analyzed for chemical and bacteriological properties. For water and personal hygiene, quality indices were calculated, and a mathematical model was developed using multiple linear regression analysis. The regression concluded that personal hygiene has a more significant effect on the occurrence of...
Unlike urban and semi-urban settlements where the potable water is supplied through a water treatment plant and a distribution network, in rural low-income settings, the provision of the water treatment plant for all villages is not... more
Unlike urban and semi-urban settlements where the potable water is supplied through a water treatment plant and a distribution network, in rural low-income settings, the provision of the water treatment plant for all villages is not feasible for a developing country like India. The most affordable and reliable way to provide clean drinking water is treatment at the consumer end. This research is aimed to assess occurrence of water-borne diseases based on personal hygiene and quality of drinking water source. Of the households, 4,237 in 15 selected villages were surveyed for personal hygiene using a questionnaire. Water samples were collected from all major water sources in the villages and analyzed for chemical and bacteriological properties. For water and personal hygiene, quality indices were calculated, and a mathematical model was developed using multiple linear regression analysis. The regression concluded that personal hygiene has a more significant effect on the occurrence of...