The performance of three filtering facepiece respirators (two models of N99 and one N95) challeng... more The performance of three filtering facepiece respirators (two models of N99 and one N95) challenged with an inert aerosol (NaCl) and three virus aerosols (enterobacteriophages MS2 and T4 and Bacillus subtilis phage)—all with significant ultrafine components—was examined using a manikin-based protocol with respirators sealed on manikins. Three inhalation flow rates, 30, 85, and 150 l min−1, were tested. The filter penetration and the quality factor were determined. Between-respirator and within-respirator comparisons of penetration values were performed. At the most penetrating particle size (MPPS), >3% of MS2 virions penetrated through filters of both N99 models at an inhalation flow rate of 85 l min−1. Inhalation airflow had a significant effect upon particle penetration through the tested respirator filters. The filter quality factor was found suitable for making relative performance comparisons. The MPPS for challenge aerosols was <0.1 μm in electrical mobility diameter for...
Indoor air quality has become increasingly important as we live in a society where the majority o... more Indoor air quality has become increasingly important as we live in a society where the majority of our time is spent indoors. Specific attention has been drawn to airborne fungal spores as a factor affecting indoor air quality. This study targeted shortcomings of other studies by utilizing long-term air sampling and total fungal spore enumeration to determine associations between health outcomes and fungal spore concentrations. Infants (n = 144) were clinically evaluated and had skin prick tests (SPT) for 17 allergens. Airborne fungal spores were collected using a Button Personal Inhalable Sampler (SKC Inc.) for 48 h at a flow rate of 4 l/min. Sampling was conducted in the spring (March-May) or fall (August-October) in 2003-2004. Fungal spores were analyzed using microscopy-based total counting and identified to the genus/group level. Total spore and individual genus concentrations were analyzed for associations with rhinitis and positive SPT results. Overall, concentrations varied widely, between &amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;lt;2 and 2294 spores/m(3). While no relationship was observed between SPT(+) and total fungal counts, several significant associations were found when analysis was conducted on the various fungal genera and health outcomes. Positive associations were obtained between: Basidiospores and rhinitis (p &amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;lt; 0.01), Penicillium/Aspergillus and SPT(+) to any allergen (p &amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;lt; 0.01), and Alternaria and SPT(+) to any allergen (p &amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;lt; 0.01). Inverse associations were found between: Cladosporium and SPT(+) to any allergen (p &amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;lt; 0.05), and Cladosporium and SPT(+) to aeroallergens (p &amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;lt; 0.05). This study indicates that health outcome may vary by fungal genera; some fungal types may have sensitizing effects while others may have a beneficial role.
American Industrial Hygiene Association Journal, 1998
Fibrous filter media are widely used in respirators to remove airborne particulate matter from th... more Fibrous filter media are widely used in respirators to remove airborne particulate matter from the inhaled airflow of workers. The N95 half-mask particulate respirator appears to be the most frequently used respirator under the new NIOSH regulation, 42 CFR 84. Considerable spatial variability in light penetration through the fibrous filter medium of an N95 respirator can be seen by visual observation when it is held to the light. This variability is due to the way in which the fibers are manufactured and laid down to form the filter medium. Similar spatial variability is expected in the aerosol penetration through the filters. Therefore, a test method has been developed for measuring the spatial variability in aerosol penetration. The main components of this method are an aerosol generator, a filter test stand with a movable sampling inlet, an aerosol size spectrometer, and an aerosol photometer. Measurements with the filter media of N95 respirators, tested at average filtration velocities corresponding to light, moderate, and heavy work loads, have shown spatial variations in aerosol penetration in excess of 100% relative to the average aerosol penetration for the entire respirator. N95 respirators are required to be at least 95% efficient (i.e., less than 5% penetrating) at the most penetrating particle size, when tested at 85 L/min. Tests with the new method have shown that the aerosol penetration of the most penetrating particles of about 0.1 micron diameter may locally be higher than 5%, while the average aerosol penetration of 0.1 micron particles is less than 5%.
Continuous emission of unipolar ions has been shown to improve the performance of respirators and... more Continuous emission of unipolar ions has been shown to improve the performance of respirators and stationary filters challenged with non-biological particles. In this study, we investigated the ion-induced enhancement effect while challenging a low-efficiency heating, ventilation and air-conditioning (HVAC) filter with viable bacterial cells, bacterial and fungal spores, and viruses. The aerosol concentration was measured in real time. Samples were also collected with a bioaerosol sampler for viable microbial analysis. The removal efficiency of the filter was determined, respectively, with and without an ion emitter. The ionization was found to significantly enhance the filter efficiency in removing viable biological particles from the airflow. For example, when challenged with viable bacteria, the filter efficiency increased as much as four- to fivefold. For viable fungal spores, the ion-induced enhancement improved the efficiency by a factor of approximately 2. When testing with virus-carrying liquid droplets, the original removal efficiency provided by the filter was rather low: 9.09 +/- 4.84%. While the ion emission increased collection about fourfold, the efficiency did not reach 75-100% observed with bacteria and fungi. These findings, together with our previously published results for non-biological particles, demonstrate the feasibility of a new approach for reducing aerosol particles in HVAC systems used for indoor air quality control. Recirculated air in HVAC systems used for indoor air quality control in buildings often contains considerable number of viable bioaerosol particles because of limited efficiency of the filters installed in these systems. In the present study, we investigated - using aerosolized bacterial cells, bacterial and fungal spores, and virus-carrying particles - a novel idea of enhancing the performance of a low-efficiency HVAC filter utilizing continuous emission of unipolar ions in the filter vicinity. The findings described in this paper, together with our previously published results for non-biological particles, demonstrate the feasibility of the newly developed approach.
The performance of three filtering facepiece respirators (two models of N99 and one N95) challeng... more The performance of three filtering facepiece respirators (two models of N99 and one N95) challenged with an inert aerosol (NaCl) and three virus aerosols (enterobacteriophages MS2 and T4 and Bacillus subtilis phage)—all with significant ultrafine components—was examined using a manikin-based protocol with respirators sealed on manikins. Three inhalation flow rates, 30, 85, and 150 l min−1, were tested. The filter penetration and the quality factor were determined. Between-respirator and within-respirator comparisons of penetration values were performed. At the most penetrating particle size (MPPS), >3% of MS2 virions penetrated through filters of both N99 models at an inhalation flow rate of 85 l min−1. Inhalation airflow had a significant effect upon particle penetration through the tested respirator filters. The filter quality factor was found suitable for making relative performance comparisons. The MPPS for challenge aerosols was <0.1 μm in electrical mobility diameter for...
Indoor air quality has become increasingly important as we live in a society where the majority o... more Indoor air quality has become increasingly important as we live in a society where the majority of our time is spent indoors. Specific attention has been drawn to airborne fungal spores as a factor affecting indoor air quality. This study targeted shortcomings of other studies by utilizing long-term air sampling and total fungal spore enumeration to determine associations between health outcomes and fungal spore concentrations. Infants (n = 144) were clinically evaluated and had skin prick tests (SPT) for 17 allergens. Airborne fungal spores were collected using a Button Personal Inhalable Sampler (SKC Inc.) for 48 h at a flow rate of 4 l/min. Sampling was conducted in the spring (March-May) or fall (August-October) in 2003-2004. Fungal spores were analyzed using microscopy-based total counting and identified to the genus/group level. Total spore and individual genus concentrations were analyzed for associations with rhinitis and positive SPT results. Overall, concentrations varied widely, between &amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;lt;2 and 2294 spores/m(3). While no relationship was observed between SPT(+) and total fungal counts, several significant associations were found when analysis was conducted on the various fungal genera and health outcomes. Positive associations were obtained between: Basidiospores and rhinitis (p &amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;lt; 0.01), Penicillium/Aspergillus and SPT(+) to any allergen (p &amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;lt; 0.01), and Alternaria and SPT(+) to any allergen (p &amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;lt; 0.01). Inverse associations were found between: Cladosporium and SPT(+) to any allergen (p &amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;lt; 0.05), and Cladosporium and SPT(+) to aeroallergens (p &amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;amp;lt; 0.05). This study indicates that health outcome may vary by fungal genera; some fungal types may have sensitizing effects while others may have a beneficial role.
American Industrial Hygiene Association Journal, 1998
Fibrous filter media are widely used in respirators to remove airborne particulate matter from th... more Fibrous filter media are widely used in respirators to remove airborne particulate matter from the inhaled airflow of workers. The N95 half-mask particulate respirator appears to be the most frequently used respirator under the new NIOSH regulation, 42 CFR 84. Considerable spatial variability in light penetration through the fibrous filter medium of an N95 respirator can be seen by visual observation when it is held to the light. This variability is due to the way in which the fibers are manufactured and laid down to form the filter medium. Similar spatial variability is expected in the aerosol penetration through the filters. Therefore, a test method has been developed for measuring the spatial variability in aerosol penetration. The main components of this method are an aerosol generator, a filter test stand with a movable sampling inlet, an aerosol size spectrometer, and an aerosol photometer. Measurements with the filter media of N95 respirators, tested at average filtration velocities corresponding to light, moderate, and heavy work loads, have shown spatial variations in aerosol penetration in excess of 100% relative to the average aerosol penetration for the entire respirator. N95 respirators are required to be at least 95% efficient (i.e., less than 5% penetrating) at the most penetrating particle size, when tested at 85 L/min. Tests with the new method have shown that the aerosol penetration of the most penetrating particles of about 0.1 micron diameter may locally be higher than 5%, while the average aerosol penetration of 0.1 micron particles is less than 5%.
Continuous emission of unipolar ions has been shown to improve the performance of respirators and... more Continuous emission of unipolar ions has been shown to improve the performance of respirators and stationary filters challenged with non-biological particles. In this study, we investigated the ion-induced enhancement effect while challenging a low-efficiency heating, ventilation and air-conditioning (HVAC) filter with viable bacterial cells, bacterial and fungal spores, and viruses. The aerosol concentration was measured in real time. Samples were also collected with a bioaerosol sampler for viable microbial analysis. The removal efficiency of the filter was determined, respectively, with and without an ion emitter. The ionization was found to significantly enhance the filter efficiency in removing viable biological particles from the airflow. For example, when challenged with viable bacteria, the filter efficiency increased as much as four- to fivefold. For viable fungal spores, the ion-induced enhancement improved the efficiency by a factor of approximately 2. When testing with virus-carrying liquid droplets, the original removal efficiency provided by the filter was rather low: 9.09 +/- 4.84%. While the ion emission increased collection about fourfold, the efficiency did not reach 75-100% observed with bacteria and fungi. These findings, together with our previously published results for non-biological particles, demonstrate the feasibility of a new approach for reducing aerosol particles in HVAC systems used for indoor air quality control. Recirculated air in HVAC systems used for indoor air quality control in buildings often contains considerable number of viable bioaerosol particles because of limited efficiency of the filters installed in these systems. In the present study, we investigated - using aerosolized bacterial cells, bacterial and fungal spores, and virus-carrying particles - a novel idea of enhancing the performance of a low-efficiency HVAC filter utilizing continuous emission of unipolar ions in the filter vicinity. The findings described in this paper, together with our previously published results for non-biological particles, demonstrate the feasibility of the newly developed approach.
Uploads
Papers by S. Grinshpun