The increase of switching speed and frequency in power electronics converters has greatly improved their performances and characteristics. These advantages are accompanied with the increased level of interference, so that EMI... more
The increase of switching speed and frequency in power electronics converters has greatly improved their performances and characteristics. These advantages are accompanied with the increased level of interference, so that EMI consideration is a major task for circuit designers nowadays. In Adjustable Speed Drives (ASD), the (dv/dt) leading to conducted emissions at high frequencies which are propagated both through Common Mode (CM) and Differential Mode (DM) in the system. The circulation of high frequency parasitic currents causes several unexpected problems, such as premature deterioration of motor winding insulation and ball bearings. In this paper an inverter-fed AC motor drive is analyzed in order to predict the path of conducted emissions into Common Mode (CM) configuration, showing that both propagation modes may interfere. The equivalent circuit allows frequency-domain analysis to be performed with standard circuit simulators. The proposed circuit model allows the prediction...
This paper aims to analyze a hybrid photovoltaic system for production of electrical energy associated with a storage system to be employed in an isolated site. Mathematical models were proposed describing the physical operation of each... more
This paper aims to analyze a hybrid photovoltaic system for production of electrical energy associated with a storage system to be employed in an isolated site. Mathematical models were proposed describing the physical operation of each part of the studied system, according to the meteorological conditions or the estimated data. Then programs developed with Matlab software were carried out to simulate the influence of various parameters on each element of the conversion chain. The results obtained have shown a good and accurate simulation of the energy behavior of the complete system and can be used to give answers to many questions about this type of installation and to help manufacturers make the right decisions.
Introduction. Most electromagnetic compatibility models developed for the study of three-phase induction machines are generally valid for low and medium frequencies (<< 1 MHz). This frequency limit seems to be too restrictive for... more
Introduction. Most electromagnetic compatibility models developed for the study of three-phase induction machines are generally valid for low and medium frequencies (<< 1 MHz). This frequency limit seems to be too restrictive for the overall study of conducted electromagnetic interference. In this paper, the model is using the proposed model and compared with experimental results in low and medium frequency. And then, the high-frequency modeling of induction motor is presented new method based on transfer function model. The proposed methodology is verified on an experimental and simulation, it’s suitable for prediction of the terminal overvoltage analysis and electromagnetic interference problems and common-mode and differential-mode currents. The novelty of the work consists to develop an improved high-frequency motor model based on transfer function to represent the motor high-frequency behavior for frequency-domain analyses in the frequency range from 40 Hz up to 110 MHz ....
DOSSIER PRÉVENTION ET RISQUES INDUSTRIELS Ce qu'il faut retenir Qu'est-ce qu'un risque industriel ? Prévention des risques professionnels et environnementaux : des concepts souvent proches Recherche d'une cohérence dans les démarches et... more
DOSSIER PRÉVENTION ET RISQUES INDUSTRIELS Ce qu'il faut retenir Qu'est-ce qu'un risque industriel ? Prévention des risques professionnels et environnementaux : des concepts souvent proches Recherche d'une cohérence dans les démarches et outils de prévention Emergence de liens entre les différents acteurs Vers une approche intégrée de la prévention Publications, outils, liens… SOMMAIRE DU DOSSIER Accueil > Démarches de prévention > Risques industriels Ce qu'il faut retenir Les activités sur un site industriel génèrent des risques qui se retrouvent sous le vocable de « risques industriels » et qui ont un impact : sur les salariés et dans ce cas, il s'agit des risques professionnels. sur l'environnement extérieur, les populations avoisinantes et sur les biens et dans ce cas, il s'agit de risques environnementaux. Ces risques industriels sont la conséquence du fonctionnement habituel de l'entreprise. Ils sont qualifiés de « risques majeurs » quand : la gravité des conséquences qu'ils sont susceptibles de causer à l'environnement extérieur est importante, la probabilité d'apparition est faible. La confusion entre risque environnemental et risque industriel est classique. Elle occulte du même coup le risque professionnel qui en est pourtant une composante. L'industriel doit gérer de façon cohérente ces différentes composantes du risque industriel et favoriser la mise en place d'actions efficaces tant pour la prévention des risques professionnels qu'environnementaux. L'industriel pourra s'appuyer sur les similitudes d'approches existantes dans la prévention des risques professionnels et environnementaux à plusieurs niveaux : des notions communes : danger, risque, dommage des concepts souvent proches : illustration par le principe de prévention des démarches et outils à utiliser de façon cohérente : illustration par l'évaluation des risques des acteurs de prévention différents qui tendent à se rapprocher. Ce dossier « Prévention et risques industriels » ne rappelle pas dans le détail la réglementation relative aux installations classées (ICPE), les procédures de déclaration et d'autorisation d'exploiter, le contenu des dossiers à fournir ou encore les méthodes d'études de dangers.