Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
JACC: CARDIOVASCULAR INTERVENTIONS VOL. 7, NO. 3, 2014 ª 2014 BY THE AMERICAN COLLEGE OF CARDIOLOGY FOUNDATION PUBLISHED BY ELSEVIER INC. ISSN 1936-8798/$36.00 http://dx.doi.org/10.1016/j.jcin.2013.05.034 Translational Effect of the Endothelial Shear Stress Patterns on Neointimal Proliferation Following Drug-Eluting Bioresorbable Vascular Scaffold Implantation An Optical Coherence Tomography Study Christos V. Bourantas, MD, PHD,* Michail I. Papafaklis, MD, PHD,y Anna Kotsia, MD,z Vasim Farooq, MB, CHB,* Takashi Muramatsu, MD, PHD,* Josep Gomez-Lara, MD, PHD,* Yao-Jun Zhang, MD, PHD,* Javaid Iqbal, PHD,* Fanis G. Kalatzis, MD, PHD,x Katerina K. Naka, MD, PHD,z Dimitrios I. Fotiadis, PHD,x Cecile Dorange, MSC,k Jin Wang, PHD,{ Richard Rapoza, PHD,{ Hector M. Garcia-Garcia, MD, PHD,* Yoshinobu Onuma, MD,* Lampros K. Michalis, MD,z Patrick W. Serruys, MD, PHD* Rotterdam, the Netherlands; Boston, Massachusetts; Ioannina, Greece; Diegem, Belgium; and Santa Clara, California Objectives This study sought to investigate the effect of endothelial shear stress (ESS) on neointimal formation following an Absorb bioresorbable vascular scaffold (BVS) (Abbott Vascular, Santa Clara, California) implantation. Background Cumulative evidence, derived from intravascular ultrasound–based studies, has demonstrated a strong association between local ESS patterns and neointimal formation in bare-metal stents, whereas in drug-eluting stents, there are contradictory data about the effect of ESS on the vessel wall healing process. The effect of ESS on neointimal development following a bioresorbable scaffold implantation remains unclear. Methods Twelve patients with an obstructive lesion in a relatively straight arterial segment, who were treated with an Absorb BVS and had serial optical coherence tomographic examination at baseline and 1-year follow-up, were included in the current analysis. The optical coherence tomographic data acquired at follow-up were used to reconstruct the scaffolded segment. Blood flow simulation was performed on the luminal surface at baseline defined by the Absorb BVS struts, and the computed ESS was related to the neointima thickness measured at 1-year follow-up. Results At baseline, the scaffolded segments were exposed to a predominantly low ESS environment (61% of the measured ESS was <1 Pa). At follow-up, the mean neointima thickness was 113  45 mm, whereas the percentage scaffold volume obstruction was 13.1  6.6%. A statistically significant inverse correlation was noted between baseline logarithmic transformed ESS and neointima thickness at 1-year follow-up in all studied segments (correlation coefficient range 0.140 to 0.662). Mixed linear regression analysis between baseline logarithmic transformed ESS and neointima thickness at follow-up yielded a slope of 31 mm/ln(Pa) and a y-intercept of 99 mm. Conclusions The hemodynamic microenvironment appears to regulate neointimal response following an Absorb BVS implantation. These findings underline the role of the ESS patterns on vessel wall healing and should be taken into consideration in the design of bioresorbable devices. (J Am Coll Cardiol Intv 2014;7:315–24) ª 2014 by the American College of Cardiology Foundation 316 Bourantas et al. Shear Stress and Neointima Formation in BVS Neointimal formation is modulated by several local factors, including the vessel wall trauma caused during stent deployment, the plaque burden, and the composition of the underlying plaque, as well as local endothelial shear stress (ESS) patterns (1–5). Several clinical and experimental studies have provided evidence that local hemodynamic factors, in particular low ESS, promote neointimal formation in bare-metal stents, whereas in drug-eluting stents, the association between ESS and neointimal proliferation is weak and appears to be affected by the mechanisms of action and probably the release kinetics of the eluted drug (6–8). Bioresorbable scaffold is a new technology introduced to overcome the long-term implications of metallic caging, because these devices have the unique ability to disappear after implantation, allowing restoration of vessel physiology (9). The first clinical studies provided evidence about the safety and efficacy of these devices and revealed a gradual increase of the neointima tissue, which, however, was accommodated by the expanding scaffold and did not appear to affect luminal dimensions (10). We have recently demonstrated that neointima tissue has an asymmetric distribution around the circumferAbbreviations ence of the vessel wall, indicating and Acronyms that local factors (i.e., vessel wall trauma, increased plaque in3D = 3-dimensional flammation, and local hemodyESS = endothelial shear namics) are likely to be involved stress and regulate this process (11). IVUS = intravascular ultrasound The aim of the present analysis was to investigate the impact NT = neointimal thickness of ESS on neointima proliferaOCT = optical coherence tion following an Absorb biotomographic/tomography resorbable vascular scaffold (BVS) (Abbott Vascular, Santa Clara, California) implantation. In contrast to previous reports, we utilized optical coherence tomographic (OCT) data to reconstruct the surface of the scaffolded segment at baseline, simulate blood flow, and assess vessel wall healing. The high resolution of this imaging technique allows more detailed reconstruction of luminal morphology and evaluation of the hemodynamic microenvironment and its impact on neointimal growth. Methods Included patients and study design. We analyzed data from the patients recruited in the second group of the ABSORB From the *Department of Interventional Cardiology, Erasmus University Medical Centre, Thoraxcenter, Rotterdam, the Netherlands; yCardiovascular Division, Brigham & Women’s Hospital, Harvard Medical School, Boston, Massachusetts; zDepartment of Cardiology, Medical School, University of Ioannina, Ioannina, Greece; xDepartment of Materials Science and Engineering, University of Ioannina, Ioannina, Greece; kAbbott Vascular, Diegem, Belgium; and {Abbott Vascular, Santa Clara, California. The ABSORB Cohort B study was sponsored and financially JACC: CARDIOVASCULAR INTERVENTIONS, VOL. 7, NO. 3, 2014 MARCH 2014:315–24 Cohort B Trial (A Clinical Evaluation of the Everolimus Eluting Bioresorbable Vascular Scaffold System in the Treatment of Patients With De Novo Native Coronary Artery Lesions; NCT00856856). The study design has already been described in detail by Serruys et al. (12). In brief, 101 patients with single- or 2-vessel de novo coronary disease implanted with an Absorb BVS (dimensions 3.0  18 mm) were included in this prospective multicenter trial. The studied population was divided into 2 groups. Both groups had serial angiographic, grayscale intravascular ultrasound (IVUS), IVUS virtual histology, and OCT evaluation at 3 time points. The first group (B1) had these tests at baseline post-device implantation and at 6 months and 2 years follow-up, whereas the second group (B2) had these investigations at baseline, 1-year, and 3-year follow-up. Thus the current analysis included only the patients from Cohort B2 who had received an Absorb BVS in a relatively straight coronary segment and had undergone OCT evaluation at baseline and 1-year follow-up. The ABSORB Cohort B study was approved by the human research committee of the institutions that participated. Informed consent was obtained from all patients. Computation of vessel angulation. Biplane coronary angiographic imaging that would allow accurate reconstruction of coronary geometry was available only in 1 patient at 1-year follow-up. Thus, coronary reconstruction was performed using only the OCT data neglecting the vessel curvature. To minimize the error introduced by this approximation, we analyzed relatively straight arterial segments. The angulation of the treated segments was assessed using a previously described methodology (13). In brief, an expert observer reviewed the angiographic images acquired at 1-year followup and selected an end-diastolic projection where there was minimal foreshortening and overlapping of the scaffolded segment. The angulation of the scaffolded segment was defined as the angle formed by the tangents of the centerlines of the 5-mm proximal and distal parts of the segment. To classify the scaffolded segments as straight or curved, we estimated the curvature of the segments treated in the Absorb Cohort B study during balloon inflation, assuming that the balloon straightened the treated artery. The mean  2 SD (29 ) of the angulations measured during balloon inflation was used as a cutoff value (13). Optical coherence tomography. OCT image acquisition was performed at baseline (immediately after scaffold implantation) and at 1-year follow-up using a C7XR Fourier Domain supported by Abbott Vascular. Dr. Bourantas is funded by the Hellenic Cardiological Society. Dr. Dorange is an employee of Abbott Vascular. Drs. Wang and Rapoza are employees of and hold stock in Abbott Vascular. All other authors have reported that they have no relationships relevant to the contents of this paper to disclose. Manuscript received February 20, 2013; revised manuscript received April 26, 2013, accepted May 9, 2013. JACC: CARDIOVASCULAR INTERVENTIONS, VOL. 7, NO. 3, 2014 MARCH 2014:315–24 system (LightLab Imaging, Westford, Massachusetts). The data acquired at baseline were analyzed by 2 expert observers blinded to patients’ procedural and clinical characteristics, who reviewed the scaffolded segment and identified in each frame the embedded, the protruded, and the malapposed struts. Embedded struts were struts where the surface was >50% impacted in the vessel wall; struts were considered protruded when they were in contact with the vessel wall but with <50% of their surface being impacted in the vessel wall; and malapposed when the struts’ abluminal surface was not in contact with the vessel wall. The feasibility of this classification has previously been tested in our department, and the reported results have shown a high interobserver agreement (kappa index 0.75) (14). The data acquired at 1-year follow-up were used to reconstruct 2 surfaces: 1) the luminal surface at baseline post-scaffold implantation; and 2) the luminal surface at 1-year follow-up. In each follow-up OCT examination, the observers identified the frames portraying the scaffolded segment and analyzed 1 frame at every 0.4-mm interval in the non-scaffolded segment and 1 frame at 0.2-mm intervals in the scaffolded segment. The luminal morphology at baseline was approximated by the luminal borders in the non-scaffolded segment at 1-year follow-up. In the scaffolded segment, the observers identified corresponding struts between baseline and follow-up OCT examinations, and in the case where the baseline struts were embedded, the baseline luminal borders were defined by splines connecting the adluminal sides of the struts (portrayed at the frames acquired at 1-year follow-up), whereas in the case where the baseline struts were protruded or malapposed, the baseline luminal borders were defined by the adluminal sides of the struts (portrayed at the frames acquired at 1-year follow-up) and between struts by the segment connecting the abluminal sides of adjacent struts (Fig. 1). For the struts where it was not possible to identify correspondence between baseline and follow-up examinations, we assumed that these struts were protruded because the majority of the struts were protruded at the baseline examination (14). The luminal surface at follow-up was constructed by the luminal borders in the scaffolded segment defined by the endoluminal borders of the neointima. Malapposed struts at 1-year follow-up were not taken into consideration, and in these segments, the baseline luminal border was approximated by the endoluminal border of the neointima (Fig. 1). Segments exhibiting extensive malapposition (malapposition seen in >25% of the frames portraying the scaffolded segment) were excluded from the analysis. Reconstruction of coronary anatomy. The vessel centerline was approximated by a straight line with a length equal to the length of the studied coronary artery. The center of mass of the luminal borders in native segments, and of the scaffold borders (defined by the abluminal side of the scaffold) in scaffolded segments, were estimated, and these borders were Bourantas et al. Shear Stress and Neointima Formation in BVS 317 Figure 1. Segmentation of the OCT Data Acquired at 1-Year Follow-Up Optical coherence tomography (OCT) image acquired at baseline (A) and the corresponding frame at 1-year follow-up showing the distal end of a scaffolded segment (the distal marker is located at 11 o’clock) (B). The green line in C corresponds to the luminal border at baseline, as defined in the follow-up frame, and the blue line corresponds to the scaffold perimeter. Four corresponding struts were identified in the baseline and follow-up frames, 2 of which (struts 3 and 4) were embedded at baseline. It was not possible to identify correspondence for 4 struts (indicated with an asterisk). The area between the luminal border at baseline and follow-up (red line) corresponds to the neointima tissue portrayed in D in a semi-transparent fashion. In the second case example, strut malapposition (strut 1) was noted in 2 corresponding OCT images acquired at baseline (E) and 1-year follow-up (F). In this location, the baseline and follow-up luminal border and the scaffold perimeter are defined by the endoluminal side of the neointima (G and H). 318 Bourantas et al. Shear Stress and Neointima Formation in BVS then placed perpendicularly onto the centerline in their corresponding locations with their center of mass being positioned on the vessel centerline. This approach is likely to distort the anatomy of eccentric lesions located proximally or distally to the scaffold; however, it is expected to provide a more accurate representation of the coronary morphology in the scaffolded segment and eliminate the wave-like artifacts JACC: CARDIOVASCULAR INTERVENTIONS, VOL. 7, NO. 3, 2014 MARCH 2014:315–24 introduced by the movement of the catheter (during the cardiac circle) that can affect the ESS measurements (Fig. 2). The final outcome of this process is 2 non-uniform, rational B-spline surfaces: the first representing the luminal surface at baseline (constructed by the luminal borders in the non-scaffolded segment and by the scaffold borders in the scaffolded segment), and the second representing the Figure 2. 3D Reconstruction of a Scaffolded Segment Longitudinal optical coherence tomographic (OCT) view of a coronary segment implanted with an Absorb bioresorbable vascular scaffold (BVS) (A). The red arrows indicate the changes in the position of the OCT catheter with respect to the lumen wall as a result of the 3-dimensional (3D) geometry of the vessel, and the vessel motion during the cardiac circle, while the white arrow indicates a protruded plaque into the lumen. (B) The reconstructed artery with the endothelial shear stress (ESS) portrayed in the baseline 3D surface with the use of a color-coded map. The model in panel C was obtained after positioning the detected borders on the vessel centerline using their gravitational centers. The change in vessel geometry affected ESS distribution, especially in segments with eccentric-protruded plaques and increased curvature (white arrow). As shown in the magnified panels, the morphology of the baseline luminal surface (F) resembles the luminal morphology portrayed in the high-resolution 3D volume–rendered frequency domain OCT image obtained immediately after device deployment (E) and the electron microscopy photo (D) acquired from a rabbit artery 2 weeks after Absorb BVS implantation. Bourantas et al. Shear Stress and Neointima Formation in BVS JACC: CARDIOVASCULAR INTERVENTIONS, VOL. 7, NO. 3, 2014 MARCH 2014:315–24 luminal surface at 1-year follow-up (constructed by the luminal borders in the scaffolded segment). Blood flow simulation. The obtained geometries were further processed with computational fluid dynamics techniques for the generation of a finite volume mesh. Anisotropic meshes with unstructured tetrahedral elements were generated for each baseline surface using an automated mesh generation program (ICEM CFD version 11, ANSYS, Canonsburg, Pennsylvania). To capture the detailed characteristics of the hemodynamic microenvironment, mesh density was increased around the stent struts and within the boundary layer of the flow field, and had a maximum element edge equal to approximately one-fourth of the BVS strut thickness (i.e., w40 mm). Blood flow simulation was performed by solving the 3-dimensional (3D) Navier-Stokes equations (CFX 11, ANSYS). Blood was considered as a homogeneous, Newtonian fluid with a dynamic viscosity of 0.0035 Pa$s and a density of 1,050 kg/m3. Blood flow was considered to be steady, laminar, and incompressible, and a flat velocity profile was imposed at the inlet of the entire reconstructed arterial segment. Coronary blood flow for each artery was estimated by measuring in 2 angiographic projections, obtained at baseline post-scaffold implantation, the number of frames required for the contrast agent to pass from the inlet to the outlet of the reconstructed segment, the volume of the segment at baseline, and the cine frame rate (6). The arterial wall was considered to be rigid, and no-slip conditions were applied at the baseline luminal surface, whereas zero-pressure conditions were imposed at the outlet. ESS at the baseline luminal surface was calculated as the product of blood viscosity and the gradient of blood velocity at the wall. Data analysis and statistics. In the scaffolded segment, the lumen volume at baseline and 1-year follow-up was estimated, and the neointimal volume was defined as: the lumen volume at baseline minus the lumen volume at follow-up, whereas the percentage volume obstruction was defined as: 100 times the neointima volume divided by the lumen volume at baseline. Neointima thickness (NT) was calculated as the distance between the luminal surface at baseline and the luminal surface at follow-up using an in-house– developed algorithm implemented in Visual Fortran 6.5 (Compaq Computer Corporation, Houston, Texas) (15). Positive values corresponded to areas of neointimal hyperplasia. NT was measured along the axial direction per 0.2 mm and around the vessel circumference per 5 for each cross section, and was associated with ESS at the corresponding location. A part of the scaffolded segment at the entrance and exit of the scaffold, covering a length of 2.5 mm, was excluded from the analysis. Segments within the scaffold located at the origin of side branches and their adjacent segments with length equal to the diameter of the side branch were also excluded from the analysis; the branches were not included in the 3D reconstruction, as the 319 ESS assessment in these areas is not considered to be reliable. Continuous variables are presented as mean  SD, whereas categorical variables are presented as counts and percentages. Pearson correlation coefficient and linear regression analyses were implemented to investigate the association between the baseline ESS or the logarithmic transformed ESS (lnESS) and the estimated NT at followup. To control for patient effect, a mixed model with random intercept and slope was used to estimate the overall association between lnESS and NT. In this mixed model, the autoregressive covariance structure was utilized to take into consideration the nested structure of cross sections within subjects. The interobserver agreement in the identification of corresponding struts between baseline and follow-up examination was evaluated with the use of the Cohen’s kappa test. A p value <0.05 was considered statistically significant. Statistical analysis was performed with the SPSS statistical software package (version 18.0 for Windows, SPSS, Chicago, Illinois) and SAS software (version 9.2, SAS Institute, Cary, North Carolina). Results Patient characteristics. Twenty-one patients (22 lesions) from Cohort B2 were investigated with OCT at baseline and 1-year follow-up. In 14 patients (14 arteries), the treated segments had an angulation <29 . Two cases were excluded from the analysis: the first because of extensive malapposition and the second because of poor OCT image quality. Table 1. Baseline Characteristics of the Studied Population (N ¼ 12) Age, yrs 61  9 Male 8 (67) Hypertension 8 (67) Hypercholesterolemia 7 (58) Diabetes mellitus 0 (0) Current smoking 4 (33) Prior percutaneous coronary intervention 1 (8) Prior myocardial infarction 2 (17) Stable angina 10 (83) Unstable angina 1 (8) Silent ischemia 0 (0) Treated vessel Left anterior descending artery 9 (75) Left circumflex artery 2 (17) Right coronary artery 1 (8) Ramus intermedius 0 (0) Medications Beta-blockers Renin-angiotensin aldosterone inhibitors Statins Values are mean  SD or n (%). 9 (75) 9 (75) 10 (83) 320 Bourantas et al. Shear Stress and Neointima Formation in BVS JACC: CARDIOVASCULAR INTERVENTIONS, VOL. 7, NO. 3, 2014 MARCH 2014:315–24 Thus, 12 segments were reconstructed. The baseline characteristics of the studied population are shown in Table 1. Most of the patients had hypercholesterolemia (58%) and hypertension (67%), and 83% were treated for stable angina. Coronary reconstruction analysis. The length of the reconstructed segments was 47.6  10.5 mm, whereas the length of the scaffolded segment was 19.6  0.8 mm. Neointimal proliferation was evident in all treated segments, which resulted in a percentage scaffold volume obstruction of 13.1  6.6% (Table 2). The mean NT derived from the measurements in the 12 patients (scaffold level analysis) was 113  45 mm (range 72 to 200 mm). Shear stress analysis. In the 12 patients (scaffold-level analysis), the mean ESS measured in the scaffolded segments at baseline was 1.10  0.35 Pa. Sixty-one percent of the ESS estimations in the 12 scaffolded segments were <1 Pa. In native segments, the ESS values were higher (2.53  1.24 Pa, p < 0.0001); only 21% of the ESS estimations were <1 Pa. As shown in Figure 3, the protruded struts created a rough luminal surface at baseline that affected the local hemodynamic microenvironment. Flow recirculation zones were noted proximally and distally to the protruded struts, resulting in low ESS in these regions and relatively high ESS on top of the struts (Fig. 4). The low ESS noted in these areas appeared to have affected neointima formation with increased tissue formation proximally and distally to the scaffold struts and with limited neointima formation on top of the struts (Figs. 3 and 4). A negative correlation coefficient (average 0.385, statistically different from 0; p < 0.001) was noted between the baseline ESS and the NT at 1-year follow-up in all of the studied scaffolded segments. The correlation coefficient was higher after the logarithmic transformation of the baseline ESS (average 0.451; p < 0.001). Table 3 provides the correlation coefficients between baseline lnESS and NT for each subject, as well as the estimated slopes and y-intercepts after applying linear regression analysis for each subject (Fig. 5). The linear mixed effects model yielded an overall slope of 31 mm/ln(Pa) and y-intercept of 99 mm. Table 2. Quantitative Analysis of the Scaffolded Segment in the 3D Reconstructed Arteries (N = 12) Baseline mean lumen area, mm2 6.70  1.35 Follow-up mean lumen area, mm2 5.85  1.43 Mean neointima tissue area, mm2 0.85  0.38 Mean neointima thickness, mm 113  45 Lumen volume at baseline, mm3 130.9  25.7 Lumen volume at follow-up, mm3 114.6  28.2 Neointima tissue volume, mm3 16.4  6.9 Percentage volume obstruction, % 13.1  6.6 Values are mean  SD. 3D ¼ 3-dimensional. Interobserver agreement in identifying corresponding struts in OCT examinations. The reliability of the 2 observers in identifying corresponding struts between baseline and the follow-up examinations was examined in 100 frames randomly selected from 8 patients. The Kappa index was 0.79, indicating a good agreement. Discussion In this study, we used for the first time serial OCT data and computational fluid dynamics techniques to evaluate the effect of the hemodynamic microenvironment on neointimal formation post-Absorb BVS implantation. We found that: 1) the thick protruded struts (strut thickness 156 mm) of the implanted scaffold create a rough surface that causes flow disturbance and recirculation zones resulting in low ESS; and 2) the reported low ESS contributed to neointimal formation because there was a negative correlation in all of the scaffolded segments between ESS and NT. Several computational experimental and clinical reports in the past have examined the effect of stent implantation on local hemodynamics and the association between ESS and neointimal formation. In silico blood flow simulation studies have underscored the effect of stent design on local hemodynamic patterns: the stents that have thick, rectangularshaped struts cause flow disruption and lead to a low ESS environment, whereas the devices with thin, circular-shaped struts appear to minimally influence the local flow and ESS (16–19). The connection of the struts seems also to affect ESS patterns: strut connectors that are parallel to the flow direction have a minimal effect on ESS, whereas strut connectors that have a perpendicular arrangement to the flow direction influence considerably the ESS distribution and increase the in-stent areas exposed to low ESS (20). Clinical studies in 3D models obtained from patient data have shown an inverse correlation between ESS and NT in bare-metal stents, whereas in drug-eluting stents, there are conflicting reports (6,7,21,22). Gijsen et al. (22) demonstrated an inverse relation between ESS and neointimal formation in patients treated with sirolimus-eluting stents, whereas Suzuki et al. (21) found that ESS had no impact on neointimal development in diabetic patients implanted with the same type of stent. Papafaklis et al. (6) evaluated the association between neointimal formation and ESS in 10 patients implanted with paclitaxel-eluting stents and 10 patients treated with sirolimus-eluting stents, and found an inverse correlation between ESS and NT in the paclitaxel arm, but no significant association in the group of patients implanted with sirolimus-eluting stents, advocating that these findings are due to the different pathophysiological effect of each drug on vessel wall healing and the pro-restenotic ESS-related biological pathway. However, a significant limitation of the aforementioned studies is the fact that neointimal formation was measured assuming that stent struts JACC: CARDIOVASCULAR INTERVENTIONS, VOL. 7, NO. 3, 2014 MARCH 2014:315–24 Bourantas et al. Shear Stress and Neointima Formation in BVS 321 Figure 3. Distribution of the ESS and of the NT in a Scaffolded Segment (A) Endothelial shear stress (ESS) patterns in the scaffolded segment portrayed in a color-coded map and (B) the corresponding neointima thickness (NT). The dashed lines in the reconstructed segment in A and B indicate the location of the optical coherence tomographic images in 1 and 2. 10 and 20 show the ESS distribution at baseline across the circumference of the vessel wall, and in 10 0 and 20 0 , the neointima thickness is portrayed in a semi-transparent fashion. As shown in i, ii, and iii, the ESS is low in the between-strut areas and high on top of the struts. The neointima tissue appears to be increased in segments with low ESS and reduced in segments with high ESS values. were well apposed post-device implantation and that coronary reconstruction was based on IVUS, an imaging modality with a limited radial resolution that cannot accurately evaluate the lumen surface irregularities caused by the stent struts and the modest neointima proliferation in drug-eluting stents. The present study overcomes the aforementioned pitfalls because it uses for the first time OCT to reconstruct the coronary lumen. OCT, with its high radial resolution, allows reliable evaluation of luminal morphology, detailed assessment of strut apposition, and accurate estimation of NT. In addition, the heterogeneous appearance of the struts of the Absorb BVS in OCT permits us to find corresponding struts at baseline and follow-up examinations and use this information for more reliable reconstruction of the baseline luminal surface (23). The high resolution of OCT allowed us to confirm for the first time in vivo the 322 Bourantas et al. Shear Stress and Neointima Formation in BVS JACC: CARDIOVASCULAR INTERVENTIONS, VOL. 7, NO. 3, 2014 MARCH 2014:315–24 Figure 4. Longitudinal Section of a Scaffolded Segment The blood flow streamlines are shown with velocity color coding (map on the right), whereas the endothelial shear stress (ESS) distribution along the baseline luminal surface is portrayed according to the color-coded map (left). The neointima thickness at 1-year follow-up is shown in a semi-transparent fashion. Low ESS and recirculation zones are noted in the interstrut areas, whereas ESS values are high on top of the struts. The ESS distribution appears to affect neointimal formation, because there is increased neointima tissue in the regions between the struts and minimal neointima over the struts. findings of computational flow dynamic studies on theoretical models and demonstrate that the thick, protruded struts disrupt flow, resulting in recirculation zones in front of and especially behind the struts. These regions are exposed to low ESS (ESS were <1 Pa in 61% of the scaffolds’ surfaces), which appears to promote neointimal growth (24). In contrast to previous reports that showed that rapamycin derivatives abrogate the effect of ESS on neointimal formation, we found a statistically significant correlation between Table 3. Correlation Coefficient, Slope, and y-Intercept Patient # Correlation Coefficient Slope (mm/(ln)Pa) y-Intercept (mm) 1 0.480 30 116 2 0.412 37 181 206 3 0.140 35 4 0.426 26 57 5 0.386 28 84 6 0.488 29 85 7 0.533 31 69 8 0.590 34 65 9 0.662 39 122 10 0.410 24 58 11 0.428 33 72 12 0.455 30 68 The correlation coefficient, slope, and y-intercept were obtained after applying linear regression analysis between logarithmic transformed baseline endothelial shear stress (lnESS) and neointima thickness at 1-year follow-up in each case. Figure 5. Association Between ESS and NT Regression curves showing the correlation between the endothelial shear stress (ESS) (lnESS) at baseline and neointima thickness (NT) at follow-up in the 12 segments included in the current analysis (A). Regression analysis between lnESS and neointima thickness for a typical case (B). ESS and NT in all studied segments implanted with an everolimus-eluting BVS (6,8,21). This discrepancy should be attributed to the more reliable evaluation of NT thickness and baseline ESS patterns in the reconstructed by OCT data segments, as well as to the longer follow-up period. In previous studies, the association between NT and ESS was evaluated at 6 and 9 months follow-updonly 3 or 6 months after the complete elution of the antiproliferative drug (25). In Absorb BVS, 80% of the everolimus elution is released within the first month and is completed 3 months after device implantation (26). It can be speculated that after the first months, the low ESS promoted neointimal formation, resulting in a negative association between ESS at baseline and neointimal formation at 1-year follow-up. In this analysis, we focused on the association between ESS and NT at 1-year follow-up and not at other time points (i.e., at 3 years follow-up or at 6 months or 2 years follow-up using the data of the ABSORB Cohort B1 group) for the following reasons: 1) one-half of the baseline OCT examinations in the Cohort B1 group were performed by an M-3 Time Domain system, which has different radial and axial resolution and image quality from the C7XR Fourier Bourantas et al. Shear Stress and Neointima Formation in BVS JACC: CARDIOVASCULAR INTERVENTIONS, VOL. 7, NO. 3, 2014 MARCH 2014:315–24 Domain system, and thus, it is not feasible to find corresponding struts between baseline and follow-up examinations; 2) our objective was not to compare our findings with the results of the IVUS-based reconstruction studies in metallic drug-eluting stents, but rather to examine the midterm effect of ESS on NT where the antiproliferative drug has been eluted and the effect of vessel wall injury has dissipated; and 3) although it would be interesting to compare the association between ESS and NT at 2 different follow-up time points (i.e., at 1- and 3-year follow-up), because it has been shown that neointimal tissue continues to develop, the proposed analysis cannot be applied at 2- or 3-year follow-up because the scaffold loses its structural integrity after 1 year and expands; thus we cannot approximate the baseline luminal surface in the scaffolded segment based on the location of the struts at 2- or 3-year follow-up (10,27). To our knowledge, this is the first study that examines the effect of ESS on neointimal proliferation postbioresorbable scaffold implantation. We found that the early depolymerization of the scaffold’s struts does not apparently affect the mechanotransduction pathways that regulate the response of the free (i.e., noncovered by struts) vessel wall to the local hemodynamic microenvironment (28–30). Hence, the current design (in-phase zigzag hoops linked with bridges; strut thickness of 156 mm) and composition (polyL-lactic struts, covered by a thin layer of an amorphous matrix of poly-D,L-lactide that controls the release of the antiproliferative drug everolimus) of the Absorb BVS seems to provide a template for the formation of a potentially protective thin layer of neointimal tissue that without restricting the luminal dimensions covers the underlying plaque and the scaffold’s struts, minimizing the risk for late scaffold thrombosis. Furthermore, the neointima tissue that developed in the areas between the struts appears to smooth the luminal morphology and normalize the ESS, creating in the long term an athero-protecting environment (31). Study limitations. A significant limitation of this analysis is the use of the follow-up OCT data to reconstruct both the baseline and follow-up luminal surface. This was done because there were significant differences in corresponding OCT frames, regarding the number of the portrayed struts and their circumferential distribution, between baseline and follow-up examinations (Fig. 1). Thus, it was not possible to accurately associate the luminal surface derived from the baseline OCT data with the luminal surface reconstructed at follow-up so as to quantify the NT and examine the effect of the baseline ESS on neointimal proliferation. Another limitation of the current analysis is the lack of biplane angiographic data that would allow accurate 3D reconstruction of the coronary anatomy. To address this drawback, we included in this analysis relatively straight coronary arteries, assuming that they were totally straight segments and that the scaffold was symmetrically expanded. We have recently reported a high minimal luminal/maximal 323 luminal diameter ratio (0.85  0.08) in IVUS cross-sectional images of segments implanted with an Absorb BVS 1.1, a fact that indicates a symmetric expansion of the device (32). However, potential asymmetries in scaffold expansion that may have affected the estimated association between ESS and NT cannot be excluded. The effect of malapposed struts on local hemodynamics was not taken into account in this analysis. Considering the overall low reported prevalence of malapposed struts and the fact that we excluded segments with extensive malapposition, it is unlikely for this approximation to have affected our results (14). Conclusions In this study, we used serial OCT data to reconstruct the coronaries and evaluate the effect of the hemodynamic microenvironment on neointimal formation after Absorb BVS implantation. We found a statistically significant inverse association between ESS and NT in all of the studied segments. These findings underscore the role of local hemodynamic milieu on vessel wall healing and should be taken into consideration in the design of bioresorbable devices. Reprint requests and correspondence: Dr. Patrick W. Serruys, Interventional Cardiology Department, Erasmus Medical Center, ‘s-Gravendijkwal 230, 3015 CE Rotterdam, the Netherlands. E-mail: p.w.j.c.serruys@erasmusmc.nl. REFERENCES 1. Hoffmann R, Mintz GS, Mehran R, et al. Intravascular ultrasound predictors of angiographic restenosis in lesions treated with PalmazSchatz stents. J Am Coll Cardiol 1998;31:43–9. 2. Farb A, Weber DK, Kolodgie FD, Burke AP, Virmani R. Morphological predictors of restenosis after coronary stenting in humans. Circulation 2002;105:2974–80. 3. Shimada Y, Kataoka T, Courtney BK, et al. Influence of plaque calcium on neointimal hyperplasia following bare metal and drug-eluting stent implantation. Catheter Cardiovasc Interv 2006;67:866–9. 4. Koskinas KC, Chatzizisis YS, Antoniadis AP, Giannoglou GD. Role of endothelial shear stress in stent restenosis and thrombosis: pathophysiologic mechanisms and implications for clinical translation. J Am Coll Cardiol 2012;59:1337–49. 5. Prati F, Di Mario C, Moussa I, et al. In-stent neointimal proliferation correlates with the amount of residual plaque burden outside the stent: an intravascular ultrasound study. Circulation 1999;99:1011–4. 6. Papafaklis MI, Bourantas CV, Theodorakis PE, et al. The effect of shear stress on neointimal response following sirolimus- and paclitaxeleluting stent implantation compared with bare-metal stents in humans. J Am Coll Cardiol Intv 2010;3:1181–9. 7. Wentzel JJ, Krams R, Schuurbiers JC, et al. Relationship between neointimal thickness and shear stress after Wallstent implantation in human coronary arteries. Circulation 2001;103:1740–5. 8. Cheng C, Tempel D, Oostlander A, et al. Rapamycin modulates the eNOS vs. shear stress relationship. Cardiovasc Res 2008;78:123–9. 9. Serruys PW, Garcia-Garcia HM, Onuma Y. From metallic cages to transient bioresorbable scaffolds: change in paradigm of coronary revascularization in the upcoming decade? Eur Heart J 2012;33:16–25b. 10. Ormiston JA, Serruys PW, Onuma Y, et al. First serial assessment at 6 months and 2 years of the second generation of absorb everolimus-eluting 324 Bourantas et al. Shear Stress and Neointima Formation in BVS bioresorbable vascular scaffold: a multi-imaging modality study. Circ Cardiovasc Interv 2012;5:620–32. 11. Brugaletta S, Radu MD, Garcia-Garcia HM, et al. Circumferential evaluation of the neointima by optical coherence tomography after ABSORB bioresorbable vascular scaffold implantation: can the scaffold cap the plaque? Atherosclerosis 2012;221:106–12. 12. Serruys PW, Onuma Y, Ormiston JA, et al. Evaluation of the second generation of a bioresorbable everolimus drug-eluting vascular scaffold for treatment of de novo coronary artery stenosis: six-month clinical and imaging outcomes. Circulation 2010;122:2301–12. 13. Gomez-Lara J, Garcia-Garcia HM, Onuma Y, et al. A comparison of the conformability of everolimus-eluting bioresorbable vascular scaffolds to metal platform coronary stents. J Am Coll Cardiol Intv 2010;3:1190–8. 14. Gomez-Lara J, Radu M, Brugaletta S, et al. Serial analysis of the malapposed and uncovered struts of the new generation of everolimuseluting bioresorbable scaffold with optical coherence tomography. J Am Coll Cardiol Intv 2011;4:992–1001. 15. Papafaklis MI, Bourantas CV, Theodorakis PE, Katsouras CS, Fotiadis DI, Michalis LK. Relationship of shear stress with in-stent restenosis: bare metal stenting and the effect of brachytherapy. Int J Cardiol 2009;134:25–32. 16. Duraiswamy N, Schoephoerster RT, Moore JE Jr.. Comparison of nearwall hemodynamic parameters in stented artery models. J Biomech Eng 2009;131:061006. 17. Jimenez JM, Davies PF. Hemodynamically driven stent strut design. Ann Biomed Eng 2009;37:1483–94. 18. Mejia J, Ruzzeh B, Mongrain R, Leask R, Bertrand OF. Evaluation of the effect of stent strut profile on shear stress distribution using statistical moments. Biomed Eng Online 2009;8:8. 19. LaDisa JF Jr., Olson LE, Guler I, et al. Circumferential vascular deformation after stent implantation alters wall shear stress evaluated with time-dependent 3D computational fluid dynamics models. J Appl Physiol 2005;98:947–57. 20. Pant S, Bressloff NW, Forrester AI, Curzen N. The influence of strutconnectors in stented vessels: a comparison of pulsatile flow through five coronary stents. Ann Biomed Eng 2010;38:1893–907. 21. Suzuki N, Nanda H, Angiolillo DJ, et al. Assessment of potential relationship between wall shear stress and arterial wall response after bare metal stent and sirolimus-eluting stent implantation in patients with diabetes mellitus. Int J Cardiovasc Imaging 2008;24:357–64. 22. Gijsen FJ, Oortman RM, Wentzel JJ, et al. Usefulness of shear stress pattern in predicting neointima distribution in sirolimus-eluting stents in coronary arteries. Am J Cardiol 2003;92:1325–8. JACC: CARDIOVASCULAR INTERVENTIONS, VOL. 7, NO. 3, 2014 MARCH 2014:315–24 23. Gutierrez-Chico JL, Radu MD, Diletti R, et al. Spatial distribution and temporal evolution of scattering centers by optical coherence tomography in the poly(L-lactide) backbone of a bioresorbable vascular scaffold. Circ J 2012;76:342–50. 24. Stone PH, Saito S, Takahashi S, et al. Prediction of progression of coronary artery disease and clinical outcomes using vascular profiling of endothelial shear stress and arterial plaque characteristics: the PREDICTION study. Circulation 2012;126:172–81. 25. Yazdani SK, Vorpahl M, Nakano M, Su SH, Kolodgie FD, Virmani R. In vitro and in vivo characterisation of biodegradable polymer-based drug-eluting stent. EuroIntervention 2011;7:835–43. 26. Ormiston JA, Serruys PW, Regar E, et al. A bioabsorbable everolimuseluting coronary stent system for patients with single de-novo coronary artery lesions (ABSORB): a prospective open-label trial. Lancet 2008; 371:899–907. 27. Serruys PW, Onuma Y, Dudek D, et al. Evaluation of the second generation of a bioresorbable everolimus-eluting vascular scaffold for the treatment of de novo coronary artery stenosis: 12-month clinical and imaging outcomes. J Am Coll Cardiol 2011;58: 1578–88. 28. Oberhauser JP, Hossainy S, Rapoza RJ. Design principles and performance of bioresorbable polymeric vascular scaffolds. EuroIntervention 2009;5 Suppl F:F15–22. 29. Chatzizisis YS, Coskun AU, Jonas M, Edelman ER, Feldman CL, Stone PH. Role of endothelial shear stress in the natural history of coronary atherosclerosis and vascular remodeling: molecular, cellular, and vascular behavior. J Am Coll Cardiol 2007;49:2379–93. 30. Vorpahl M, Finn AV, Nakano M, Virmani R. The bioabsorption process: tissue and cellular mechanisms and outcomes. EuroIntervention 2009;5 Suppl F:F28–35. 31. Bourantas CV, Papafaklis MI, Garcia-Garcia HM, et al. Short- and long-term implications of a bioresorbable vascular scaffold implantation on the local endothelial shear stress patterns. J Am Coll Cardiol Intv 2014;7:100–1. 32. Brugaletta S, Gomez-Lara J, Diletti R, et al. Comparison of in vivo eccentricity and symmetry indices between metallic stents and bioresorbable vascular scaffolds: insights from the ABSORB and SPIRIT trials. Catheter Cardiovasc Interv 2012;79:219–28. Key Words: bioresorbable scaffold - endothelial shear stress - neointimal formation - optical coherence tomography.