This article appeared in a journal published by Elsevier. The attached
copy is furnished to the author for internal non-commercial research
and education use, including for instruction at the authors institution
and sharing with colleagues.
Other uses, including reproduction and distribution, or selling or
licensing copies, or posting to personal, institutional or third party
websites are prohibited.
In most cases authors are permitted to post their version of the
article (e.g. in Word or Tex form) to their personal website or
institutional repository. Authors requiring further information
regarding Elsevier’s archiving and manuscript policies are
encouraged to visit:
http://www.elsevier.com/copyright
Author's personal copy
Journal of Pharmaceutical and Biomedical Analysis 56 (2011) 45–53
Contents lists available at ScienceDirect
Journal of Pharmaceutical and Biomedical Analysis
journal homepage: www.elsevier.com/locate/jpba
Characterization of in vivo plasma metabolites of tepoxalin in horses using
LC–MS–MS
Mario Giorgi a , Grazia Mengozzi a , Andrea Raffaelli b , Alessandro Saba c,∗
a
Department of Veterinary Clinics, University of Pisa, Via Livornese (lato monte) 1, 56010 San Piero a Grado, Pisa, Italy
National Centre of Researches, Institute of Chemistry of Organic-metallic Compounds, UOS Pisa, Via Moruzzi 1, 56124 Pisa, Italy
c
Department of Chemistry and Industrial Chemistry, University of Pisa, Via Risorgimento 35, 56126 Pisa, Italy
b
a r t i c l e
i n f o
Article history:
Received 22 September 2010
Received in revised form 18 March 2011
Accepted 21 March 2011
Available online 30 March 2011
Keywords:
Tepoxalin
Metabolism
Horses
LC–MS–MS
In vivo
a b s t r a c t
Tepoxalin is a veterinary drug registered for use in the dog as a dual inhibitor (cyclooxygenase - 5 lipoxygenase). In the horse, it predominantly triggers a strong cyclooxygenase inhibition; this bias seems to
be due to the action of its metabolite(s). Among these, only the RWJ-20142 is well known, while to the
best of our knowledge no information is available on the other metabolites produced in vivo. Hence, the
identification of its main metabolic pathway is pivotal to better understand its clinical activity.
A suitable high performance liquid chromatography method has been applied to liquid
chromatography–mass spectrometry for the characterization of the main metabolites in plasma of horses
orally treated with tepoxalin. Mass spectrometry in full scan, product ion scan and precursor ion scan
modes, provided information useful in elucidating large parts of the structure of the unknown metabolites detected. These structures are closely related to that of tepoxalin. One of these metabolites was
speculated to be a structural isomer of the parental drug.
These findings could be important to understand the pharmacology of tepoxalin in horses.
© 2011 Elsevier B.V. All rights reserved.
1. Introduction
Chronic inflammatory diseases, such as osteoarthritis, are one
of the most important causes of reduced performance in animals,
especially in horses [1]. Non-steroidal anti-inflammatory drugs
(NSAIDs) are the most commonly used therapy [2]. Tepoxalin
is a dual inhibitor NSAID with analgesic, anti-inflammatory, and
antipyretic properties. It has recently been registered as a veterinary drug. Because of the inhibition of 5 lipoxygenase (5-LO),
tepoxalin may offer a novel approach both to the preservation
of gastro-intestinal mucosal integrity and reduction of bronchoconstriction [3]. Tepoxalin has been approved for use in dogs by the
European Committee for Medicinal Products for Veterinary Use as
Zubrin (Schering-Plough) [4].
Studies conducted in rats [5], chickens [6], rabbits [7], dogs [5,8]
horses [9] and humans [10], reported maximum plasma concentrations were reached between 0.7 and 4 h after oral tepoxalin
Abbreviations: NSAIDs, non-steroidal anti-inflammatory drugs; 5-LO, 5 lipoxygenase; COX-1, cyclo-oxygenase-1; DP, declustering potential; IS, ionspray voltage;
CUR, curtain gas; GS1, gas source 1; GS2, gas source 2; TEM, source temperature; EP,
entrance potential; MS2, tandem mass spectrometry; EP, entrance potential; CAD,
nitrogen as a collision; CE, collision energy.
∗ Corresponding author. Tel.: +39 050 2219277; fax: +39 050 2219295.
E-mail address: saba@dcci.unipi.it (A. Saba).
0731-7085/$ – see front matter © 2011 Elsevier B.V. All rights reserved.
doi:10.1016/j.jpba.2011.03.028
administration. Tepoxalin is also rapidly converted to its active
metabolite RWJ-20142. The latter molecule is produced in large
amounts, has a long plasma half-life and seems to possess cyclooxygenase-1 (COX-1) inhibitor activity only. In chickens and horses,
the presence of a new unknown metabolite has been speculated
based on the chromatographic data [6,11]. The characterization of
metabolic compounds, used in research and clinical programs, is
an essential prerequisite for use of a drug or its registration in a
new animal species. Species differences in drug metabolic fate are,
in most cases, the primary source of variation in drug disposition,
and, therefore in drug activity and toxicity across species. An important element of the clinical characterization of the drug effect is
the identification of metabolic products and their activities. The
number and quantity of these compounds can vary from species to
species and they are often present in very low concentrations (ca.
0.01–0.5%). This does not mean that these products can be ignored
because they could exhibit a large range of activities; from high
toxicity up to high effectiveness. Separation of such in vivo formed
compounds, for detailed structure elucidation, is the first step of
this process. An on-line technique capable of providing structural
information can be of great value. Through the use of capabilities that allow direct interfacing to HPLC, mass spectrometry can
rapidly provide data to assist in the identification and characterization of drug metabolite products. The aim of the present study
is to identify the metabolic pathway of tepoxalin in the plasma of
horses 10 h following oral administration.
Author's personal copy
46
A
M. Giorgi et al. / Journal of Pharmaceutical and Biomedical Analysis 56 (2011) 45–53
administration, the nasogastric tube was rinsed with 1 L of distilled
water to ensure complete delivery of the drug into the stomach.
Blood samples for analysis (10 mL) were collected by venipuncture from the jugular at 0 and 10 h after tepoxalin administration,
and placed in collection tubes containing lithium heparin. The
blood samples were centrifuged at 400 × g for 5 min within 30 min
of collection, and the harvested plasma was stored at −20 ◦ C and
was analyzed within 14 days after collection.
H3CO
N
N
O
N
OH
Cl
2.4. Sample preparation
2. Materials and methods
Detection of tepoxalin, its active acidic metabolite (RWJ-20142)
and its putative metabolites in plasma were carried out by highperformance liquid chromatography, using a modification of a
procedure developed by Homer et al. [8]. Briefly, 0.5 mL plasma
was added in a glass test tube, followed by 1 mL 0.1 M phosphate buffer (pH 6) and 5 mL methyl-t-butyl ether. The tube was
capped, vortexed for approximately 30 s, and then centrifuged to
separate organic from aqueous layers. The organic layer was aspirated, transferred to another test tube, and evaporated under a N2
stream until dry. The residue was dissolved in 200 L mobile phase
(43% 50 mM ammonium acetate buffer (CH3 COONH4 /CH3 COOH pH
5), 20% methanol, and 37% acetonitrile). Concentration standards
(0, 0.1, 0.5, and 1 g/mL) were prepared by adding appropriate
amounts of tepoxalin and RWJ-20142 dissolved in methanol to
plasma collected from untreated horses. Standards were subjected
to the same analytical procedure as test samples. Extracted samples were poured through 0.45 m nylon filters and 50 L aliquots
were injected into a HPLC-FL.
2.1. Chemicals
2.5. HPLC-FL
Tepoxalin 5-(4-chlorophenyl)N-hydroxy-1(4-methoxyphenyl)N-methyl-1H-pyrazole-3-propamide) (99.9% pure) and its
acid metabolite (RWJ-20142) (3-[5-(4-chlorophenyl)-1-(4methoxyphenyl)-1H-pyrazol-3-yl]-propanoic acid) (99.7% pure)
(Fig. 1) standard powders, were a gift from Schering-Plough Co.
(Summit, NJ, USA). HPLC-grade water from Baker (Baker Analyzed®
Reagent, J.T. Baker, Deventer, Holland) was used for buffer preparation. The methanol and acetonitrile used were of HPLC grade from
Carlo Erba (Milan, Italy). Acetic acid, methyl-t-butyl ether, sodium
phosphate and ammonium acetate, were of analytical-reagent
grade from Sigma (St. Louis, MI, USA).
The high-performance liquid chromatography system consisted
of a PU 980 isocratic pump attached to an AS-1550 autosampler and
an 821-FP fluorimetric detector (Jasco, Essex, UK). Integration was
performed using Borwin chromatographic software (version 1.21).
The compounds were separated by a C18 column (250 mm × 4.6 mm
i.d., 5 m particle size) (Gemini, Phenomenex, Torrance, CA, USA).
The flow rate of the mobile phase was 1.0 mL/min. Injection volume was 50 L and the detector wavelengths were set at 290 nm
and 440 nm as excitation and emission, respectively [11]. The chromatography was conducted at room temperature.
B
H3CO
N
N
O
OH
Cl
Fig. 1. Molecular structure of (A) tepoxalin, (B) its active metabolite (RWJ-20142).
2.6. HPLC–MS
2.2. Animals
Three female horses, 10- to 15-year-old, weighting 450–500 kg,
were used in the study. Animals were housed in separate indoor
recovery rooms for the duration of the study and were determined
to be in good health by physical examination and hematology.
Except during the study, animals were fed a standard diet, alpha
alpha hay in the morning (8 kg/day) (Equifioc, Molitoria Val di Serchio, Lucca, Italy) and crops in the afternoon (1.5 kg/day). They had
ad libitum access to water. Animal protocols were approved by the
Institutional Animal Care and Use Committee of the University of
Pisa (authorization n◦ 9403 transmitted to the Italian Ministry of
Health).
2.3. Experimental design
The mares received an oral single dose of tepoxalin at 10 mg/kg
BW (Zubrin 200 mg tablets, Schering-Plough, Co. Summit, NJ, USA).
The drug was administered in the morning, the horses were fasted
for 12 h the previous night and up to 6 h after drug administration. All the animals were given the oral lyophilised formulation
dissolved in 100 mL of distilled water via nasogastric tube. After
HPLC–MS experiments were carried out by an AB-Sciex API
4000 triple quadrupole mass spectrometer (Concord, ON, Canada),
equipped with a Turbo-V electrospray (ESI) source, coupled to a
Perkin Elmer 200 Series HPLC system (Waltham, MA, USA), including a binary micro pump system, a high pressure mixer, a column
oven, and an auto-sampler. HPLC made use of the same column,
mobile phase composition and flow rate used for HPLC-FL. Mass
spectrometry was first used in full scan mode (MS), in order to
investigate the presence of unknown compounds which could be
involved in the metabolic pathway of tepoxalin. Afterward, tandem mass spectrometry experiments were carried out in order
to elucidate the structure of those compounds. In detail, full scan
acquisitions were mainly carried out according to the following
parameters: positive ion mode; mass range, 250–410 Th; declustering potential (DP), 50 V; ionspray voltage (IS), 5.5 kV; curtain gas
(CUR), nitrogen at 10 arbitrary units; gas source 1 (GS1), zero air
at 55 arbitrary units; gas source 2 (GS2), zero air at 50 arbitrary
units; source temperature (TEM), 650 ◦ C; entrance potential (EP),
10 V. Tandem mass spectrometry experiments were carried out in
both product ion scan (MS2) and precursor ion scan modes, by using
10 V as an entrance potential (EP), nitrogen as a collision (CAD) gas
Author's personal copy
M. Giorgi et al. / Journal of Pharmaceutical and Biomedical Analysis 56 (2011) 45–53
47
Fig. 2. (I) Chromatographic curve using plasma from the horses administered with tepoxalin (10 h); (II) chromatographic curve from fortified sample (tepoxalin, RWJ-2014,
both 0.1 g/mL) of horse plasma; (III) chromatographic curve from blank of horse plasma.
Author's personal copy
48
M. Giorgi et al. / Journal of Pharmaceutical and Biomedical Analysis 56 (2011) 45–53
4.4e8
Intensity, cps
A
3.30
2.2e8
11.15
2.47
0
4.4e8
9.20
Intensity, cps
3.30
2.2e8
2.47
0
2
B
13.71
11.15
5.00
3.78
5.63
4
6
10.47
6.78
8
10
12
14
16
18
20
22
24
Time, min
Fig. 3. Comparison between the total ion current chromatogram from horse plasma samples, as it is at 0 h (A) and 10 h after the tepoxalin administration (B).
at 5.1 mPa (operative pressure with CAD gas on), 30 eV as collision
energy (CE) and keeping all the other parameters as for full scan
mode acquisitions. Product ion scan mode acquisitions made use
of the following precursor ions: 329, 343, 356, 357, 370, and 386
Th, while precursor ion scan mode acquisitions were performed on
the ions at 325 and 339 Th.
and RWJ-20142 (Fig. 2). They had a good resolution and retention
times of 4.75 (A), 5.30 (B), 8.20 (RWJ-20142), 9.50 (C), 12.5 (D)
and 15.20 min (tepoxalin). No peak at higher retention time was
detected, even after increasing organic solvent and run time up
to 1 h. Similar chromatographic profiles were obtained from three
different horses.
A previous study indicated [9] that tepoxalin is totally metabolized 10 h after oral drug administration in horses (LOQ of the
method 5 ng/mL). In the present study, tepoxalin was detected in
negligible (trace) amounts in in vivo samples at 10 h (Fig. 2I). Its peak
(with the highest retention time) had a squat and elongate shape.
Actually, HPLC parameters were chosen in order to get an optimal
resolution of the unknown peaks, even though they detrimentally
affected tepoxalin peak shape that might have been overcome by
increasing the amount of organic solvent in the mobile phase after
3. Results and discussion
The HPLC method from Homer et al. [8] was modified and
adapted for the present research in accordance with its intended
use. In contrast to other previous HPLC studies [6,9,11], where only
a single unknown peak was detected, diverse peaks were distinguished by the present method. In fact, the HPLC-FL process allowed
the resolution of 4 different unknown peaks along with tepoxalin
Period A
Period B
Period C
Period D
4.5e7
Intensity, cps
9.23
3.0e7
5.01
1.5e7
6.80
0
2
Relative Intensity(%)
100%
4
A
6
10
100%
325.2
297.2
50%
8
12
14
B
18
338.2
50%
200
m/z, Th
350
339.2
357.3
203.2
50%
137.3
311.1
297.4
283.2
161.1
0%
50
Time, min
C
137.1
0%
22
356.0
297.3
189.2
20
100%
325.3
343.1
189.3
137.2
283.2
16
0%
50
200
m/z, Th
350
50
200
350
m/z, Th
Fig. 4. Total ion current chromatogram from different MS2 experiments, performed during the same HPLC run: period A (0/5.7 min), product ion scan of m/z 343 Th; period
B (5.7/8.0 min), product ion scan of m/z 356 Th; period C (8.0/12.0 min), product ion scan of m/z 357 Th; period D (12.0/27.0 min), product ion scan of m/z 386 Th. MS2 spectra
(A), (B), and (C) are relative to the chromatographic peaks at 5.01 min, 6.80 min, and 9.23 min, respectively. The plasma sample used in this acquisition was withdrawn 10 h
after the tepoxalin administration.
Author's personal copy
M. Giorgi et al. / Journal of Pharmaceutical and Biomedical Analysis 56 (2011) 45–53
Period A
Period B
Period C
13.70
3.0e7
Intensity, cps
49
1.5e7
10.51
5.65
0
2
Relative Intensity(%)
100%
4
6
x 10.0
A
8
10
100%
311.1
12
14
50%
0%
311.1
329.2
203.2
100%
22
Time, min
339.2
C
311.1
370.2
50%
356.3
297.1 352.3
386.1
297.1
146.3
50
20
327.2
50%
248.2
59.4
18
339.2
B
283.2
268.0
252.1
16
203.1
137.1
137.2
200
350
0%
50
200
m/z, Th
350
0%
50
200
m/z, Th
350
m/z, Th
Fig. 5. Total ion current chromatogram from different MS2 experiments performed during the same run: period A (0/7.5 min), product ion scan of m/z 329 Th; period B
(7.5/12.0 min), product ion scan of m/z 386 Th; period C (12/27 min), product ion scan of m/z 370 Th. MS2 spectra (A), (B), and (C) are relative to the chromatographic peaks
at 5.56 min, 10.51 min, and 13.70 min, respectively. The plasma sample used in this acquisition was withdrawn 10 h after the tepoxalin administration.
the elution of the D peak. However, a simple isocratic method was
preferred in order to avoid difficulties in the comparison between
HPLC coupled to fluorescence and to MS, using different HPLC
devices, with different specifications and dead volumes.
The samples’ analysis by HPLC-MS in full scan mode, basically
confirmed the general chromatographic profile shown by HPLCFL, although different response factors and a shift in the retention
times, caused by a different instrumental layout, were present
(Fig. 3). That made an investigation by MS on the structures of the
unknown metabolites revealed by FL possible.
A previous study [9] indicated that the concentration of metabolites (RWJ-20142 and one unknown) is highest 10 h after oral
administration of the drug in horses. A comparison between plasma
samples collected at 0 h and 10 h after tepoxalin administration
identified in the latter sample the presence of chromatographic
peaks associated to mass spectra having molecular ions at m/z 329,
100%
339.2
Relative Int.ensity(%)
A
343, 356, 357, 370, and 386 Th. All of these compounds contained
a chlorine atom, which suggested their probable involvement in
tepoxalin metabolism. Most of the MS2 spectra of these compounds
showed a base peak ion at m/z 325 or 339 Th (Figs. 4 and 5); this latter ion is also the base peak in tepoxalin’s MS2 spectrum (Fig. 6B).
Additional experiments in precursor ion scan mode using m/z 325
or 339 Th as product ions, permitted detection of all compounds
with these two ions in their MS2 spectra (Fig. 7). All these compounds had already been revealed by acquisitions in full-scan and
product ion scan modes (325 ← 343 Th, 5.01 min (II); 325 ← 356 Th,
6.81 min (III); 339 ← 357 Th, 9.23 min (IV); 339 ← 386 Th, 10.54 min
(V); 339 ← 370 Th, 13.70 min (VI)), except for one compound which
had never been detected in previous experiments: 339 ← 356 Th,
11.52 min (VII). Interestingly, although compounds III and VII both
had a [M+H]+ ion at m/z 356 Th, their MS2 spectra were quite different (Fig. 8). In particular, compound III had m/z 325 Th as a main
100%
50%
339.2
B
50%
311.3
311.2
297.1
59.3
137.2
356.3
203.3
203.2
386.2
0%
59.4
297.2
137.1
386.3
0%
50
150
250
m/z, Th
350
50
150
250
m/z, Th
Fig. 6. MS2 spectra of compound V (A) and tepoxalin (B).
350
Author's personal copy
50
M. Giorgi et al. / Journal of Pharmaceutical and Biomedical Analysis 56 (2011) 45–53
2.50e8
5.01 (II)
Intensity, cps
A
1.25e8
6.81 (III)
0
4.50e7
13.70 (VI)
Intensity, cps
9.23 (IV)
B
2.25e7
10.54
(V)
0
2
4
6
8
11.52
(VII)
10
12
14
Time, min
16
18
20
22
24
26
Fig. 7. Precursor ion scan chromatograms relative to the ions at m/z 325 Th (A) and at m/z 339 Th (B), from horse plasma sample collected at 10 h following tepoxalin
administration.
[M+H]+ containing 35 Cl, m/z 386 Th, and product ion spectra of
[M+H]+ containing 37 Cl, m/z 388 Th; this revealed those fragments having a chlorine atom (Fig. 11). Actually, in the MS2
spectrum from m/z 388 Th, these fragments are located two mass
units higher than the corresponding ions from m/z 386 Th (139
vs. 137 Th, 299 vs. 297 Th, 313 vs. 311 Th, and 341 vs. 339
Th).
Analogous analyses were done for compounds II, III, IV, VI, and
VIII and the resulting structures are reported in Fig. 12, except for
metabolite V. This was not characterized as its spectrum is very
similar to that of tepoxalin (Fig. 6). This similarity suggests that such
a compound could be an isomer of tepoxalin (I) [12], with structural
differences accounting for the difference in the retention time with
respect to the latter (10.51 vs. 17.72 min).
fragment, while compound VII exhibited m/z 339 Th as a base peak,
this is 14 mass units (CH2 ) higher. This shift was confirmed by most
of the other fragments (m/z 297 vs. 311, m/z 283 vs. 297, m/z 189 vs.
203 Th), suggesting that the OCH3 group linked to one of the phenyl
rings could have been replaced by an OH group. The experimental
data, together with data available in the literature [12], suggested
that these two ions could have the structures shown in Fig. 9A and
B.
A detailed analysis of all the information collected has led to a
tentative characterization of a large part of these compounds.
As an example, the complete MS2 fragmentation pattern of
tepoxalin is depicted in Fig. 10. A significant contribution to
the understanding of this fragmentation mechanism was provided through comparison between the product ion spectra of
Relative Int.ensity(%)
100%
325.4
A
50%
137.1
283.2
189.2
338.2
297.3
356.2
0%
50
100
150
200
250
300
Relative Int.ensity(%)
100%
350
339.2
B
50%
137.2
59.0
203.2
297.4
311.2
356.2
0%
50
100
150
200
250
300
350
m/z, Th
Fig. 8. Comparison between the MS2 spectra of two different compounds both having 355 as a molecular weight: compound III (A) and compound VII (B).
Author's personal copy
M. Giorgi et al. / Journal of Pharmaceutical and Biomedical Analysis 56 (2011) 45–53
A
51
H3CO
N
N
O
+H
Cl
B
HO
N
N
O
+H
Cl
Fig. 9. Tentative structures of the fragment ions at m/z 339 Th (A) and 225 Th (B), which are the base peak in the MS2 spectra of several tepoxalin metabolites.
Total ion current chromatogram in Fig. 3 also exhibits a small
peak at 5.63 min, associated with a spectrum containing the [M+H]+
ion at m/z 329 Th, with an isotopic cluster informing about the presence of a chlorine atom. The relative MS2 spectrum (Fig. 5A) had
a base peak at m/z 311 Th, which is consistent with the loss of a
water molecule. Unfortunately, except for the ions at m/z 311 Th,
the other fragments (expanded 10 folds in Fig. 5A) exhibited an
intensity that was always lower than 2%. Moreover, the low concentration of this compound in horse plasma could result in an
inability to detect some important fragments useful for full determination of the structure. In any case, based on extrapolation from
information on previously described compounds, VIII in Fig. 12 is
proposed as a tentative structure.
It is conceivable that some of these molecules could be the
products of impurities in Zubrin. However, Zubrin is a commer-
cial drug and as such, the manufacturers are obliged to comply
with regulations and guarantee their drug is of a high purity.
Additionally, according to a former manuscript [12], tepoxalin
impurities only result if the active ingredient is exposed to particular extremes in temperature, light or environmental conditions.
Hence, the possibility of degradation products influencing these
results is considered highly unlikely.
As far as structure V (Fig. 12) is concerned, this is the first time
that an in vivo isomeric metabolite is reported for tepoxalin; this
could play an important role in the pharmacokinetics of this drug. It
is known that isomers can play an important role in the pharmacology of several drugs, in many instances, isomers have been shown
to drastically influence the drug’s pharmacokinetic/dynamic features (i.e. [13]). An understanding of their influence is therefore
quite important for the evaluation of the correct dose to dispense.
-HN(CH3)OH
H3CO
N
-CO
m/z 339
m/z 311
N
O
-ClC6H4CCH
N
[MH]+
Cl
OH
m/z 203
H3 C
m/z 386
m/z 297
-H2CC(OH)N(CH3)OH
m/z 161
-ClC6H4CCH
Cl
m/z 137
Fig. 10. Fragmentation pattern of tepoxalin.
Author's personal copy
52
M. Giorgi et al. / Journal of Pharmaceutical and Biomedical Analysis 56 (2011) 45–53
Relative Int.ensity(%)
100%
A
339.0
50%
310.9
160.9
202.9
386.2
297.1
136.9
0%
50
Relative Int.ensity(%)
100%
100
150
200
250
300
350
B
400
340.9
50%
312.9
161.0
203.1
388.3
299.0
139.0
0%
50
100
150
200
250
300
400
350
m/z, Th
+
Fig. 11. The comparison between product ion spectra of [M+H] containing
chlorine atom.
35
Cl, m/z 386 Th (A), and containing
H3CO
37
Cl, m/z 388 Th (B), pointing out fragments including a
HO
N
N
N
N
O
O
N
OH
OH
H 3C
Cl
Cl
I
HO
II
H3C O
H3C O
N
N
N
O
N
N
NH
O
OH
H3C
Cl
N
O
NH
Cl
H3 C
Cl
III
IV
H3CO
VI
H3CO
N
N
N
O
N
OH
NH 2
Cl
Cl
VII
VIII
Fig. 12. Structures for tepoxalin and some of its metabolites: I, tepoxalin, MW 385; II, MW 342; III, MW 355; IV, RWJ20141, MW 356; VI, MW 369; VII, MW 355; VIII, MW
328.
Author's personal copy
M. Giorgi et al. / Journal of Pharmaceutical and Biomedical Analysis 56 (2011) 45–53
Hence it would be interesting to evaluate the isomers’ effectiveness
in terms of COX and 5-LO inhibitor activities.
4. Conclusions
This study describes for the first time the main plasma metabolic
pattern of tepoxalin 10 h following its oral administration in horses.
Previous studies were focused on the main metabolite (RWJ20142), without considering the others. In the present study only
one extraction method was used; because of this, some metabolites
possessing different proteolytic properties to the parental drug,
may not have been detected. Hence, further investigations are still
necessary to elucidate the full metabolic pattern of this drug.
Mass spectrometry allowed the tentative characterization of
a several tepoxalin metabolites, some of them well known and
already described in the literature as pharmaceutical impurities,
while some others, to the best of our knowledge, have never
been described. Unfortunately, no data on their pharmacological activities can be offered, but these findings pave the way for
further research on tepoxalin. Extrapolation of metabolism data
from horses and other animal species could be an important tool
to correlate in vivo pharmacokinetic and metabolic data with the
effectiveness/toxicity of the drug in different animal species.
Acknowledgements
This work was supported by Athenaeum funds (ex 60%) from
University of Pisa. Authors thank Dr A. Meizler and Dr H. Owen (University of Queensland) for their critical evaluation of the manuscript
and Schering-Plough Co. (Summit, NJ, USA) for the kind donation
of the pure standards of tepoxalin and RWJ-20142.
Appendix A. Supplementary data
Supplementary data associated with this article can be found, in
the online version, at doi:10.1016/j.jpba.2011.03.028.
53
References
[1] D.W. Richardson, R. Loinaz, An evidence-based approach to selected joint
therapies in horses, Vet. Clin. North Am. Equine Pract. 23 (2007) 443–460,
doi:10.1016/j.cveq.2007.04.007.
[2] L.R. Goodrich, A.J. Nixon, Medical treatment of osteoarthritis in the horse: a
review, Vet. J. 171 (2006) 51–69, doi:10.1016/j.tvjl.2004.07.008.
[3] P. Lees, Autacoids and antiinflammatory drugs, in: J.E. Riviere, J.E. Papich (Eds.),
Veterinary Pharmacology and Therapeutics, Wiley-Blackwell, Ames, IA, USA,
2009, pp. 457–492.
[4] Anonymous, Zubrin technical monograph, Schering-Plough Animal Health:
Union, NJ 07083-1982, 2003.
[5] E.V. Knight, J.P. Kimball, C.M. Keenan, I.L. Smith, F.A. Wong, D.S. Barrett,
A.M. Dempster, W.G. Lieuallen, D. Panigrahi, W.J. Powers, R.J. Szot, Preclinical toxicity evaluation of tepoxalin, a dual inhibitor of cyclooxygenase and
5-lipoxygenase, in Sprague-Dawley rats and Beagle dogs, Fundam. Appl. Toxicol. 33 (1996) 38–48, doi:10.1006/faat.1996.0141.
[6] S. De Boever, E. Neirinckx, K. Baert, P. De Backer, S. Croubels, Pharmacokinetics
of tepoxalin and its active metabolite in broiler chickens, J. Vet. Pharmacol.
Ther. 32 (2009) 97–100, doi:10.1111/j.1365-2885.2008.01000.x.
[7] C.G. Pollock, J.W. Carpenter, D.E. Koch, R.P. Hunter, Single and multiple-dose
pharmacokinetics of tepoxalin and its active metabolite after oral administration to rabbits (Oryctolagus cuniculus), J. Vet. Pharmacol. Ther. 31 (2008)
171–174, doi:10.2460/ajvr.70.4.522.
[8] L.M. Homer, C.R. Clarke, A.J. Weingarten, Effect of dietary fat on oral bioavailability of tepoxalin in dogs, J. Vet. Pharmacol. Ther. 28 (2005) 287–291,
doi:10.1111/j.1365-2885.2005.00644.x.
[9] M. Giorgi, B. Cuniberti, G. Ye, R. Barbero, M. Sgorbini, C. Vercelli, M. Corazza,
G. Re, Oral administration of tepoxalin in the horse: a PK/PD study, Vet. J.,
doi:10.1016/j.tvjl.2010.09.013.
[10] S.A. Waldman, C. Vitow, B. Osborne, L. Gillen, D.C. Argentieri, F.A.
Wong, I.L. Smith, A.T. Chow, J. Misiti, T.D. Bjornsson, Pharmacokinetics and pharmacodynamics of tepoxalin after single oral dose
administration to healthy volunteers, J. Clin. Pharmacol. 36 (1996)
462–468.
[11] M. Giorgi, G. Ye, M. Sgorbini, M. Corazza, Validation of a HPLC-FL method for
the determination of tepoxalin and its major metabolite in horse plasma, J.
Chromatogr. Sci. 49 (2011) 79–83.
[12] D.J. Burinsky, B.L. Armstrong, A.R. Oyler, R. Dunphy, Characterization of tepoxalin and its related compounds by high-performance
liquid chromatography/mass spectrometry, J. Pharm. Sci. 85 (1996)
159–164.
[13] E. Lavy, U. Prise, G. Soldani, D. Neri, N. Brandriss, A.B. Chaim, M.
Giorgi, Pharmacokinetics of methylphenidate after oral administration of
immediate and sustained release preparations in beagle dogs, Vet. J.,
doi:10.1016/j.tvjl.2010.07.007.