IAWA Journal, Vol. 27 (1), 2006: 89 –97
TREPHOR: A NEW TOOL FOR SAMPLING MICROCORES
FROM TREE STEMS
Sergio Rossi, Tommaso Anfodillo and Roberto Menardi
Treeline Ecology Research Unit, Dipartimento Territorio e Sistemi Agro-Forestali,
Università degli Studi di Padova, viale dellʼUniversità 16, 35020 Legnaro (PD), Italy
[E-mail: sergio.rossi@unipd.it]
SUMMARY
Detailed analyses of cambium activity and wood formation during
growth need repeated sampling of newly formed xylem. In order to be
minimally invasive, wood samples are extracted as microcores. Despite
the research done on xylem cell development and the increasing interest
in intra-annual studies of xylogenesis, few tools are available for microcore sampling. Methods originally designed for other purposes have
often been used, but no details are available on their eficiency and usefulness. Information is also lacking on laboratory preparation techniques
for cell analysis of tree-ring formation, leading to dificulties in carrying out these experiments. The advantages and limits of the tools used
up to now are described. A new tool, named Trephor (patent pending
n° PD2004A000324), speciically designed for long-lasting use is presented. Trephor is chisel-shaped for a fast recovery of 2 mm diameter
microcores. The cutting tube is inserted into the wood using a hammer
and no other accessory is required. Simple technical characteristics allow
high quality samples to be collected from both softwood and hardwood
species with minimum damage to the sampled trees. Trephor was tested
during the 2004 growing season, demonstrating good resistance to wear
and tear and mechanical stress. Embedding the microcores in parafin
for fast section preparation is described.
Key words: Trephor, xylogenesis, cambium, xylem, phloem, parafin,
rotary microtome.
INTRODUCTION
Cell development in wood follows cambium reactivation according to several physical
and biochemical processes, such as water movement into vacuoles or lignin and cellulose accumulation, in order to enlarge cell lumens and constitute cell walls (Plomion
et al. 2001; Abe et al. 2003). During the growing season, different phases of xylem
and phloem cell development are found within a few microns, going from the living
bark to the mature xylem. The anatomy of the developing tree rings is therefore highly
heterogeneous and characterized by enlarging and wall thickening cells close to both
mature and cambial cells.
Associate Editor: Thomas Yanosky
90
IAWA Journal, Vol. 27 (1), 2006
The timing and mechanisms of wood formation on short-time scales are essential
information for understanding growth dynamics in trees and the main factors affecting
xylogenesis (Chaffey 2002). In the last decade or so, several studies have been published on intra-annual analysis of radial growth. These studies are principally based on
repeated observations of the developing tree rings on wood samples during the growing
season (Bäucker et al. 1998; Camarero et al. 1998; Horacek et al. 1999; Deslauriers
et al. 2003; Rossi et al. 2003; Jones et al. 2004). Wood samples extracted in spring or
early summer are likely to be damaged because the cambium and enlarging cells have
thin primary walls. There is therefore a need for speciic extraction tools and suitable
sample preparation methods.
In order to be as little invasive as possible, wood samples are repeatedly extracted
as small cores around the stem (microcores, Fig. 1A) during the growing season (Deslauriers et al. 2003). Generally, sampling is done by means of a small cutting tube
hammered into the stem (after bark removal) and then extracted. The portion of wood
removed with the cutting tube must then be extracted from the tool for xylem tissue
analyses. Although apparently easy to do, this sampling procedure involves dificulties
connected to the core size and the above-described features of the collected tissues.
Cross sections are cut from the microcores in order to make anatomical observations
on developing cells. The quality of these sections is directly linked to the sharpness of
the cutting tube. Inadequate tools with unsharpened blades inevitably produce samples
with deep cracks or laking on the outer surface of the microcore and consequently poor
sections. Moreover, when the microcore is removed from the cutting tube, compression
of the unligniied tissues can occur thus increasing cell deformation in the meristems,
collapse of enlarging tracheids or cracks in the thickening walls.
Although there is growing interest in intra-annual studies of xylogenesis (Downes
et al. 2002; Wimmer 2002; Eckstein 2004), tools for microcore sampling have only
seldom been described (Forster et al. 2000). In many cases, products originally designed
for other purposes are used (Bäucker et al. 1998; Deslauriers et al. 2003; Mäkinen et al.
2003) but no information is available on their eficiency and usefulness in speciic
situations such as large numbers of samples, sampling on hardwood species or trees
with thick bark or low branches along the stem. Furthermore, few details have been
given of laboratory preparation techniques related to cell analysis in tree-ring formation (Antonova et al. 1995; Camarero et al. 1998; Horacek et al. 1999; Schmitt
et al. 2003), leading to dificulties in the accomplishment of such experiments. This
paper describes: 1) the tools used up to now for extracting microcores, 2) a new tool
speciically designed to overcome the limitations of these tools, and 3) a method for
preparing sections of developing wood tissues. The tools have been grouped into two
separate categories, non-speciic and speciic tools, depending on the main purpose for
which they had been designed.
NON-SPECIFIC TOOLS
The surgical bone needle (Fig. 1B) is used in the medical ield for bone marrow aspiration and consists of a stainless steel cutting tube with a sharp luted beak and plastic
Rossi, Anfodillo & Menardi — Trephor: sampling microcores
91
Fig. 1. A: Microcore. – B: Surgical bone needle, clearing rod (clr). – C: Trapsystem needle, clearing
rod (clr), Trapsystem® rod (trp). – D: Increment puncher, clearing rod (clr), punchertube (pnt),
guide tool (gdt), panel (pnl). – E: Increment hammer, clearing rod (clr). – F: Trephor.
handle. Encircling the tree trunk with one arm, the surgical bone needle is pushed in
with the other hand. The necessary pressure can be applied only if the sampling is at
about breast height. Inserting the needle into the stem otherwise becomes dificult and,
for sampling above shoulder height, almost impossible. The cutting tube has a weakly
ellipsoid inner section, so the microcores can be easily oriented. As the microcores
are more than 20 mm in length, they contain many tree rings and allow current and
previous yearsʼ radial growth to be compared. However, the inner size of the cutting
tube is only about 1.2 mm in diameter, so very few cell rows can be measured. Samples
92
IAWA Journal, Vol. 27 (1), 2006
are extracted from the cutting tube using the clearing rod (clr, Fig. 1B), but this is done
pushing against the side of the bark and phloem thus compressing the meristematic and
elongating cells and deforming the developing tree ring.
The trapsystem® needle (Fig. 1C) is a plastic-handled cutting tube with concavesharpened tip. It is inserted into the stem in the same way as the surgical bone needle.
Before extraction of the cutting tube, the sample is trapped by the Trapsystem rod (trp)
through the dentate semicircular-section tip. In the case of very long samples, a clearing
rod (clr) can be used to remove the microcores from the Trapsystem rod.
Surgical bone and Trapsystem needles are readily-available tools originally produced
for surgical biopsies. The cutting tube therefore rapidly becomes blunt, or chips or
bends, leading to cracked or laked microcores after a few samplings. The insertion
technique also requires a close approach to the stem, which is dificult when trees retain
low branches.
SPECIFICALLY DESIGNED TOOLS FOR MICROCORE EXTRACTION
The increment puncher (Fig. 1D, Forster et al. 2000) partially resolves the problems
described for surgical needles. The cutting tube (punchertube, pnt), gliding along a
guide, is hammered into the stem by means of pressure from the palm of the hand. The
guide consists of a panel (pnl) ixed to the stem with a strap or belt. The inclination
of the panel, and thus sample direction, can be regulated by means of 3 screws. The
clearing rod is introduced in the punchertube by the cutting side, thus avoiding damage to
immature cells. In order to avoid damage to the blade, the clearing rod and punchertube
are connected through a guiding tool (gdt).
The increment puncher is speciically designed to extract microcores 15 mm in length
and 2 mm in diameter from living plants. However, its disadvantages include the long
time required to ix the panel on the stem and the dificulty of sampling on hardwood
species or trees with thick bark. Moreover, spare blades often go missing or are dificult
to ind. In the ield, the smaller components can easily get lost on the ground and cause
delays. The procedure of inserting the punchertube by means of a blow applied with
the palm of the hand becomes uncomfortable when repeated on several trees, even for
sampling of softwood species.
The increment hammer (Fig. 1E) is formed by a spherical head with a cutting tube
at right angles to the metal handle. The microcore is sampled by thrusting the cutting
tube hard into the stem. The clearing rod on the opposite side of the head is used to
push out the microcore, but pressure occurs from the phloem side and so compresses
the weak cells. Moreover, the sampling point on the stem is not precisely assessed.
Trephor (patent pending in Italy, n° PD2004A000324) was designed and produced
at the Centro Studi per lʼAmbiente Alpino in San Vito di Cadore (Italy) for extracting
microcores from living trees. A Trephor for microcores of 15 mm in length and 2 mm
in diameter is shown in Figure 1F. The tool is named after a mountain in the Cinque
Torri group (Cortina, Italy), the location of some of the study sites and where the tool
was tested throughout the 2004 growing season. Trephor is designed speciically for
long-term microcore sampling in forests. The simple and innovative technical characteristics offer: 1) high-quality samples on both softwood and hardwood species,
Rossi, Anfodillo & Menardi — Trephor: sampling microcores
93
2) minimum damage to sampled trees, 3) ergonomic shape, 4) simple use, 5) robustness, 6) operative safety. It is a chisel-like tool with fast sample recovery. The cutting
tube is inserted into the wood using a hammer and no other accessories are required.
Trephor is composed of a single, compact and easily-transported tool. A main element (mnl) is ixed to two coplanar asymmetric arms at right angles, a back axis (tail,
tl) and a piercing head (prh) in tempered stainless steel (Fig. 2 A). The cross shape
allows a hammer to be used to ease penetration in the stem of any tree species. The
two asymmetric arms allow a comfortable grip for easy and fast extraction of the
Trephor from the stem. The piercing head (Fig. 2 B) consists of a cutting tube (ctt)
cylinder-shaped outside and cone-shaped inside connected by two supports (fork, frk)
with a U-shaped main element. The fork opens the back of the head for collecting the
extracted microcores. The inner cone shape limits metal friction and abrasive effects
on the microcore and damage to xylem tissues. After extracting the piercing head from
Fig. 2. A: Trephor (version for sampling microcores 2 mm in diameter and 15 mm in length) in
the three orthogonal projections, main element (mnl), back axis (tail, tl), piercing head (prh).
– B: side and front views of Trephor piercing head, main element (mnl), fork (frk), cutting tube
(ctt) (all measures in millimetres).
94
IAWA Journal, Vol. 27 (1), 2006
the stem, the wood sample enclosed in the cutting tube can be removed by a slight push
from the sharp side of the tube without any cell deformation. The tool, weighing about
120 g, can be protected by thermo-insulating paint or covered with thermo-restricting
plastic. The shape and constructional choices of the cutting tube are a compromise
between elasticity and hardness. The stainless steel is tempered at 300 °C for 12 hours
to confer speciic characteristics on each part of the cutting tube in order to withstand
wear and tear and mechanical stress. The harder sharp part can be hammered into the
hardwood without any damage to the blade and the more elastic basal part resists when
struck by the hammer during sampling. Innovative shape, technical characteristics and
the materials used allow high-quality microcores to be obtained even after hundreds
of samplings, unlike the other blades that at best must be sharpened after a few dozen
samples. When moving in the forest, the cutting tube is protected by a hood and the
tool stored in a pocket or small bag for user safety and to prevent blade damage.
HOW TO USE TREPHOR
As the cutting tube is only 1.5 cm long, thick barks should be removed in order to sample
the living tissues. For young trees or species with thin bark, no preliminary operation
is generally needed, thus minimizing damage to the stem. The Trephor piercing head
is held against the sampling position with three ingers, checking that the asymmetric
arms do not hit the hand while the cutting tube is being hammered into the wood. The
microcore is separated from the xylem by holding the asymmetric arms and rotating
the tool like a corkscrew, thus extracting the cutting tube with movements coaxial to
the main element. When Trephor is held in the palm of the hand with the blade facing
the ingers and the longer asymmetric arm towards the outside, delicate pressure is
suficient to separate the sample from the cutting tube. The microcore slides along the
inside of the cutting tube and falls directly onto the hand from the back of the piercing
head. The microcores are then placed in Eppendorf microtubes in an ethanol solution
(0.5 in water) and stored at 5 °C. The overall time spent for the sampling is generally
half a minute.
MICROCORE EMBEDDING AND CUTTING
After having extracted the microcores, the wood sections for light microscope can be
prepared by means of sledge microtomes or hand cuts. Both methods are useful when
samples can be easily handled or ixed on a support. The microcores consist of two parts
with different consistency and density: a compact side composed of the mature xylem
and a soft side with phloem and differentiating cells, thus precluding a stable ixing
of the whole sample. Microcores also often break in half close to the cambial zone,
leading to irreversible damage to the tissues and loss of wood material for observations.
However, use of a rotary parafin microtome solves the problems related to the small
size and fragility of the samples.
Sample preparation involves the embedding of the microcores in paraffin by means
of dehydration with ethanol and D-limonene and the successive immersion in liquid
Rossi, Anfodillo & Menardi — Trephor: sampling microcores
95
Fig. 3. A: Parafin blocks containing microcores. – B: Parafin strip with microcore sections
obtained by rotary microtome. – C: Microcore sections placed on microscope slides. – D: mature
tracheids of Picea abies in polarized light (× 500). Scale bar = 20 μm. – E: Phloem of Larix
decidua (× 500). Scale bar = 20 μm. – F: Microcore section of Pinus cembra (× 100) containing
mature xylem (mxl), mature phloem (mph) and developing cells (dcl), including the cambial
zone (czn). Scale bar = 50 μm.
96
IAWA Journal, Vol. 27 (1), 2006
Table 1. Steps for parafin embedding. D-limoparafin at 65 °C, as reported in Table 1
nene is a natural agent with low toxicity specif(Anderson & Bancroft 2002). The miically formulated to replace xylene during the
crocores are then fixed on supports
clearing steps.
(biocassettes) by means of parafin
blocks (Fig. 3 A). In this way, the parafReagent
Time (min)
in penetrates into the wood and ills the
Ethanol 70%
120
cell lumens in both xylem and phloem
Ethanol 70%
120
tissues.
Ethanol 90%
90
Before making the inal cut, the outer
Ethanol 90%
90
excess layer of parafin is removed. The
Ethanol 95%
90
parafin blocks are then immersed in
Ethanol 100%
90
Ethanol 100%
90
water at room temperature for 20–120
D-limonene
90
minutes, depending on the sample size
D-limonene
90
and wood hardness, in order to lubriD-limonene
90
cate the walls and facilitate the cut.
Parafin
120
Microtome Feather R35 blades are genParafin
120
erally used for cutting 20–40 samples
of both hardwood and softwood species, producing sections without apparent damage to the cell wall (Fujii 2003). The
samples, blocked on the microtome clamp, oscillate vertically and meet the knife.
Each run, the clamp advances towards the knife and parafin ilms containing sections
of pre-set thickness (8–12 μm) are cut. After some runs, the continuous parafin strip
produced (Fig. 3 B) is plunged in water at 45–55 °C in order to stretch the sections
and to place the ilms on the microscope slides. For greater adhesion of the sections,
the slides should previously be treated with albumin or polylysine. Sections are dried
at 50 °C for 1 hour and cleaned of residual parafin by immersing in D-limonene and
ethanol. After complete elimination of the parafin, the sections are ready for staining
and observation under the microscope (Fig. 3 C).
Microcores extracted during the growing season are composed both of cells already
completely provided with secondary walls (mature xylem cells, Fig. 3 D) and cells with
thinner secondary walls (phloem, Fig. 3 E) or lacking secondary wall (cambium). The
parafin embedding technique and the use of a rotary microtome for the analyses of
developing wood tissues allow suitable sections of these heterogeneous tissues to be
obtained even when both are present in the same sample (Fig. 3 F). Moreover, parafin
blocks can be stored and preserved for further cuts and observations.
CONCLUSIONS
Study of forest tree xylogenesis requires speciic methods of wood sampling and section preparation. Although few details are available on these techniques, several tools
exist for extracting and cutting microcores, but not all of them have been speciically
designed for small wood samples and heterogeneous tissues. Trephor and the rotary
parafin microtome have been shown to be suitable tools for microcore sampling and
the fast preparation of wood sections for the analysis of both mature cells and developing xylem.
Rossi, Anfodillo & Menardi — Trephor: sampling microcores
97
ACKNOWLEDGEMENTS
This work was funded by the MIUR-PRIN 2002 and Progetto di Ateneo MAXY 2004. The authors
wish to thank the Regole of Cortina dʼAmpezzo for permitting the study on their property and the
Dipartimento di Sanità Pubblica, Patologia Comparata ed Igiene Veterinaria for technical support.
Special thanks to Annie Deslauriers for suggestions on the manuscript.
REFERENCES
Abe, H., T. Nakai, Y. Utsumi & A. Kagawa. 2003. Temporal water deicit and wood formation
in Cryptomeria japonica. Tree Physiol 23: 859–863.
Anderson, G. & J. Bancroft. 2002. Tissue processing and microtomy including frozen ???.
In: J.D. Bancroft & M. Gamble (eds.), Theory and practice of histological techniques: 85–107.
Churchill Livingstone, London.
Antonova, G.F., V.P. Cherkashin, V.V. Stasova & T.N. Varaksina. 1995. Daily dynamics in xylem
cell radial growth of Scots pine (Pinus sylvestris L.). Trees 10: 24–30.
Bäucker, E., C.T. Bues & M. Vogel. 1998. Radial growth dynamics of spruce (Picea abies) measured by micro-cores. IAWA J. 19: 301–309.
Camarero, J.J., J. Guerrero-Campo & E. Gutiérrez. 1998. Tree-ring growth and structure of Pinus
uncinata and Pinus sylvestris in the Central Spanish Pyrenees. Arct. Antarct. Alp. Res. 30:
1–10.
Chaffey, N. 2002. Why is there so little research into the cell biology of the secondary vascular
system of trees? New Phytol. 153: 213–223.
Deslauriers, A., H. Morin & Y. Begin. 2003. Cellular phenology of annual ring formation of Abies
balsamea in the Quebec boreal forest (Canada). Can. J. For. Res. 33: 190–200.
Downes, G.M., R. Wimmer & R. Evans. 2002. Understanding wood formation: gains to commercial forestry through tree-ring research. Dendrochronologia 20: 37–51.
Eckstein, D. 2004 Change in past environments – secrets of the tree hydrosystem. New Phytol.
163: 1– 4.
Forster, T., F.H. Schweingruber & B. Denneler. 2000. Increment puncher: a tool for extracting
small cores of wood and bark from living trees. IAWA J. 21: 169–180.
Fujii, T. 2003. Application of the “NT-Cutter” knife blade to microtome sectioning of wood.
IAWA J. 24: 241–245.
Horacek, P., J. Slezingerova & L. Gandelova. 1999. Effects of environment on the xylogenesis
of Norway spruce (Picea abies [L.] Karst.). In: R. Wimmer & R.E. Vetter (eds.), Tree-ring
analysis: 33–53. CAB International.
Jones, B., J. Tardif & R. Westwood. 2004. Weekly xylem production in trembling aspen (Populus
tremuloides) in response to artiicial defoliation. Can. J. Bot. 82: 590–597.
Mäkinen, H., P. Nöjd & P. Saranpää. 2003. Seasonal changes in stem radius and production of
new tracheids in Norway spruce. Tree Physiol. 23: 959–968.
Plomion, C., G. Leprovost & A. Stokes. 2001. Wood formation in trees. Plant Physiol. 127: 1513–
1523.
Rossi, S., A. Deslauriers & H. Morin. 2003. Application of the Gompertz equation for the study
of xylem cell development. Dendrochronologia 21: 33–39.
Schmitt, U., C. Grünwald, J. Gričar, G. Koch & K. Čufar. 2003. Wall structure of terminal latewood tracheids of healthy and declining silver ir trees in the Dinaric region, Slovenia.
IAWA J. 24: 41–51.
Wimmer, R. 2002. Wood anatomical features in tree-rings as indicators of environmental change.
Dendrochronologia 20: 21–36.