This paper presents the details of experimental and numerical analysis performed on three 0.8 m-high reinforced earth model walls with strip footing surcharge near the wall facing. The study investigates how wire mesh strength and... more
This paper presents the details of experimental and numerical analysis performed on three 0.8 m-high reinforced earth model walls with strip footing surcharge near the wall facing. The study investigates how wire mesh strength and geometry affect the failure mechanism. All three walls were nominally identical, except for reinforcement strength and geometry. The displacement field of the entire cross section was captured by highresolution digital camera through transparent sidewall. The resulting images were analyzed using digital image correlation software. The results indicate that both reinforcement strength and aperture size influence the type of failure mechanism. Numerical modelling was also applied to assess the influence of sidewall friction (3D model) and reinforcement stiffness and strength (2D model) on the failure mechanism of the walls. The parameters for the numerical models were derived from independent tests and results, which were compared with the experimental observations. A good level of agreement with measurements was confirmed, even for the 2D model that excluded sidewall friction.