Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

uplift capacity
Recently Published Documents


TOTAL DOCUMENTS

286
(FIVE YEARS 44)

H-INDEX

28
(FIVE YEARS 4)

2021 ◽  
Author(s):  
Wei Wang ◽  
◽  
Michael Brown ◽  
Matteo Ciantia ◽  
Yaseen Sharif ◽  
...  

Screw piles need to be upscaled for offshore use e.g. being an alternative foundation and anchor form for offshore floating wind turbines, although the high demand of vertical installation forces could prevent its application if conventional pitch-matched installation is used. Recent studies, using numerical and centrifuge physical tests, indicated that the vertical installation force can be reduced by adopting over-flighting which also improved axial uplift capacity of the screw pile. The current study extends the scope to axial cyclic performance with respect to the installation approach. Using quasi-static discrete element method (DEM) simulation it was found that the over-flighted screw pile showed a lower displacement accumulation rate, compared to a pitch-matched installed pile, in terms of load-controlled cyclic tests. Sensitivity analysis of the setup of the cyclic loading servo shows the maximum velocity during the tests should be limited to avoid significant exaggeration of the pile displacement accumulation but this may lead to very high run durations.


Géotechnique ◽  
2021 ◽  
pp. 1-42
Author(s):  
Anamitra Roy ◽  
Shiao Huey Chow ◽  
Mark F. Randolph ◽  
Conleth D. O'Loughlin

Author(s):  
Dang Khoa Nguyen ◽  
Trong Phuoc Nguyen ◽  
Suraparb Keawsawasvong ◽  
Van Qui Lai
Keyword(s):  

Author(s):  
Prem Kumar ◽  
Debtanu Seth ◽  
Bappaditya Manna ◽  
J. T. Shahu
Keyword(s):  

2021 ◽  
Author(s):  
Ragini Gogoi ◽  
Charles P. Aubeny ◽  
Phillip Watson ◽  
Fraser Bransby

Abstract Suction caissons have emerged as a viable solution for the foundations of offshore wind turbines, which are gaining momentum worldwide as an alternate energy source. When used in a multi-bucket jacket system, the system capacity is often governed by the uplift capacity of the windward bucket foundation. Seabed conditions at offshore windfarm sites often comprise dense sand where the soil response may be drained, partially drained or undrained depending on the loading regime, the foundation dimensions and the soil conditions. Given the large difference in uplift capacity of caissons for these different drainage conditions, predicting the behavior of a suction caisson under a range of drainage conditions becomes a paramount concern. Consequently, this paper presents the findings of a coupled finite element investigation of the monotonic uplift response of the windward caisson of a multi-bucket jacket system in a typical dense silica sand for a range of drainage conditions. The study adopts a Hypoplastic soil constitutive model capable of simulating the stress-strain-strength behavior of dense sand. This choice is justified by conducting a comparative study with other soil models — namely the Mohr Coulomb and bounding surface sand models — to determine the most efficient soil failure model to capture the complex undrained behavior of dense sand. The numerical predictions made in this study are verified by recreating the test conditions adopted in centrifuge tests previously conducted at the University of Western Australia, and demonstrating that the capacity from numerical analysis is consistent with the test results. The Hypoplastic soil constitutive model also provides an efficient method to produce accurate load capacity transition curves from an undrained to a drained soil state.


Author(s):  
E.C. Shin ◽  
V.K. Puri ◽  
B.M. Das ◽  
Moon-Seup Shin

Export Citation Format

Share Document