Welding Code Exam Version D1.1
Welding Code Exam Version D1.1
Welding Code Exam Version D1.1
(Version 1.1)
Directions: Answer the following AWS D1.1 Code Exam questions by filling in the correct
1. The AWS D1.1 Welding Structural Steel Code states that are welding joints must be _________ prior to performing a welding procedure: a. Free of loose scale b. Free of grease c. Free of moisture d. All of the above are correct
2. Identify the correct statement below: a. Arc strikes should be avoided on any base metal b. Arc strikes shall be ground smooth c. Arc strikes shall be checked for soundness d. All of the above are correct
3. Identify the correct AWS Welding Code statement: a. Weld cleaning is required b. Weld cleaning is required before welding over previous deposited metal c. Weld cleaning also includes removing the slag from the weld-ment d. All of the above are correct
4. All hermetically sealed low hydrogen welding electrodes (E7018 H4R A1) should be kept in an electrode oven at least: a. 125 degree F b. 250 degree F c. 327 degree F d. 412 degree F
5. Welder A states that he/she can perform a requalification retest up to four times when performing a welding qualification test at the job site. Welder B states that Welder A is wrong, and the welding code states that the welder must be trained and practice before being retested. Which is the correct answer? a. Welder A b. Welder B c. Both Welder A and B d. Neither Welder A or B
6. Identify the correct statement below: Welder A states that the groove weld joint B-U2a is designated for the SMAW process. Welder B states the that tolerances for as fit up is +1/4 for the root opening and +10 degrees for the included angle. a. Welder A is correct b. Welder B is correct c. Both welder A and B are correct d. Neither welder A or B are correct
7.
Welder A states that Figure 3.4 uses a backing bar to hold the root opening within specification. Welder B states that the root opening can be determined by the number of degrees of the included angle. Identify the correct statement below: a. b. c. d. Welder A is correct Welder B is correct Both welder A and B are correct Neither welder A or B are correct
8. a. b. c.
5.8 The minimum fillet weld size on 5/16 plate states: plate requires a 1/8 fillet weld plate requires a 3/16 fillet weld plate requires a 5/16 fillet weld
9. What is the maximum electrode diameter for a groove weld in the vertical position (Table 3.7)? a. 5/16 b. c. 3/16 d. 5/32 10. What is the maximum diameter E-7018 electrode that can be used for a root pass weld in the flat position (Table 3.7)? a. 3/32 inch b. 1/8 inch c. 5/32 inch d. 3/16 inch
11. What is the maximum allowed amperage (current) for Vertical Up welding with the SMAW process? Refer to Table 3.7 a. 150 amperes b. 250 amperes c. 350 amperes d. 500 amperes e. Follow the manufacturers recommended specifications 12. What is the minimum preheat and inter-pass temperature for welding 7/8 inch thick ASTM A710 Grade A Class 2 plate? a. none b. 300 degrees F c. 225 degrees F d. 150 degrees F e. 50 degrees F
13. If a welder is qualified on a CJP Groove weld test coupon (plate) in the vertical welding position (3G), in which is he or she also qualified? a. Production pipe welding of butt joints b. Production pipe fillet welds c. Production box tube of butt joints d. Production plate welding of fillet welds e. All of the above
14. Section 4.33 Retest section applies to which of the following individuals? a. Tack Welders b. Welders c. Welding Operators d. All of the above are correct
15. What is the minimum thickness groove weld a qualified welder may weld in production if the welder is qualified using 1 inch thick groove weld test coupon? (Table 4.11) a. Unlimited thickness b. 1 inch c. inch d. 1/8 inch e. none of the above
16. What is the allowable atmospheric exposure of low hydrogen electrode for E9018-X for Table 5.1 using column A criteria? a. one hour b. three hours c. four hours d. nine hours e. None of the above
17. What is the AWS Electrode specification of a suitable FCAW filler material for joining ASTM 871 Grade 65 steel in Table 4.9? a. AWS A5.5 b. AWS A5.23 c. AWS A5.18 d. AWS A5.29
18. Which of the following FCAW electrode classifications is code approved for question #17? a. E8010-X b. E8XTX-X c. ER70S d. F8XX-ECXXX-XX e. None of the above are correct
19. Which of the following methods cannot be used to remove unacceptable work on quenched and tempered steels? a. oxy-fuel gas gouging b. air-arc gouging c. chipping d. grinding
20. What is the maximum thickness groove weld (Table 4.11) a welder may weld in production if the welder is qualified using 3/8 inch thick groove weld test coupon? a. 1 inch b. inch c. 1/8 inch d. inch
21. What is the minimum thickness groove weld (Table 4.11) a welder may weld in production if the welder is qualified using 1 inch thick groove weld test coupon? a. Unlimited thickness b. 1 inch c. inch d. 1/8 inch e. none of the above 22. a. A b. A c. A What is the correct definition of Engineer per AWS D1.1 Code? duly designated individual who acts for and in behalf of the owner duly designated person who acts for and in behalf of the project manager duly designated individual who acts for and in behalf of the owner on all matters within the scope of the code. d. A dully designated individual who acts for and in behalf of the project manager on all matters within the scope of the code. e. None of the above 23. What are the limitations of the AWS D1.1 Welding Code? a. 1/16 plate thickness and 100 KSI steels b. 1/8 plate thickness and 100 KSI steels c. plate thickness and 100 KSI steels d. 5/16 plate thickness and 100 KSI steels 24. Which of the following documents below is referenced when changing the welding electrode consumable on a job site? a. PQR document b. WQR document c. WPS document d. Both a and c would be referenced when changing electrode consumables 25. The ASTM A514 Steel on 2 plate requires what classification of the SMAW electrodes? a. b. c. d. e. E-80XX-XX E-9010-XX E-10018-XX E-11018-XX E-12015-XX
The End
Please write your name and date on the scantron, and then return the exam and scantron!