Butterfly Valve
Butterfly Valve
Butterfly Valve
API 609/BS5155
Butterfly Valves
Standards: Design & Manufacture: API 609, BS5155 Face to Face: API 609, BS5155, DIN3202, ISO 5752 Flanged Ends: ASME B16.1, BS4504, DIN, ISO Test: AIP 598 Actuator Mounting Flange: ISO 5211 Features: 1. Small in size and light in weight and easy installation and maintenance. It can be mounted wherever needed. 2. Simple, compact structure, quick 90 deg. On-Off operation. 3. Disc has two-way bearing, perfect seal, without leakage under the pressure test. 4. Flow curve tending to straight-line. Excellent regulation performance. 5. Various kinds of materials, applicable to different medium. 6. Strong wash and brush resistance, and can fit to bad working condition. 7. Center plate structure, small torque of open and close. 8. Long service life. Standing the test of ten thousands operating and closing operation. 9. Can used in cutting off and regulating medium. Performance Data:
Nominal Diameter DN Nominal Pressure PN Shell Test Pressure Sealing Working Temperature Suitable Medium 1.0 MPa 50 ~ 300 1.6 MPa ANSI 125#
350 ~ 600 ANSI 150# 1.0 MPa 1.6 MPa ANSI 125# ANSI 150#
1.5 X PN 1.1 X PN -10 ~ 150 Water, Sewage, Sea Water, Air, Foodstuff, Oil etc
Actuators: Handles: DN50 ~ DN300 Worm Gear Electric Actuator Pneumatic Actuator
Features:
Wafer Type
Note: 14 to 24 max. working pressure with 1.6MPa can be supplied as special requirements.
Lug Type
U Type
Lug Type
Wafer Type
Lug Type
Wafer Type
10
11
Bolting Data:
12
Materials:
13
A 266.7 359
B 32 50
R 52 75.2
A 52 75 81
B 45 62.75 80
C 74 101 118
E 52 75 81
G 75 86 83
14
A 56.5 56.5
B 178.5 197.5
C 121 142
D 115 144
E 104 130
F 174 174
H 125.5 145.5
L 66 66
300 300
Model
Weight (kg)
255
154
70
191
65
126
160
200
17
302 15
171
96
240
86
175
198
300
35
Note: The enclosure class of LQA series electric actuator is IP54 (GB4208-1998) without flame-proof capability.
15
Model
Valve Size (DN) 50~100 125~150 200 ~300 350 400~450 500 600
Max. Torque Output (Nm) 100 200 600 1200 1500 2500 5000
Motor Time for Power 90 Turn (W) (S) 30 60 180 370 370 750 750 15
Weight (kg)
250 420 15 15 15 30 15
79
82
62
220
35
86
360
55
330 625 140 152 365 230 288 185 134 120 500 30
100
Note: 1. 802.120-1 is for PN16 & DN300. 2. Basic type of 802 series electric actuator can be used outdoors, protective class is IP65(GB4208-1998). Also have flame proof type, please ask for relevant technical information if necessary.
Diagram of Electric Principle for 802 & LQA Series Electric Actuators:
16
Model
56 63 90 90
45 52 63 63
20 26 26 26
86 98 123 123
Warning: Can not paralleled power cable for two or more sets of electrical actuators. Moreover, one same contact point can not control several electrical actuators. Otherwise, will cause runaway and motor overheated.
17
Model
On-Off QZ5 Regulating On-Off QZ15 Regulating On-Off QZ45 Regulating On-Off QZ85 Regulating On-Off QZ150 Regulating On-Off QZ300 Regulating 500 ~ 600 2-M10 Depth15 400 ~ 450 2-M10 Depth15 2-M14 Depth15 300 ~ 350 2-M10 Depth15 2-M14 Depth15 200 ~ 250 2-M10 Depth15 2-M12 Depth15 2-M12 Depth15 100 ~ 150 2-M10 Depth10 50 ~ 80 2-M10 Depth10
G1/4 G1/4 G1/4 G1/4 G1/4 G1/4 G3/8 G1/4 G3/8 G1/4 M10X1 Depth10 G1/4
50
902
150
902
0.5
150
902
0.5
850
902
0.5
1500
902
0.5
3000
902
0.5
18
Overall Dimensions & Weights for QZ series Pneumatic Actuators: Model QZ5 On-Off Regulating On-Off Regulating On-Off Regulating On-Off Regulating On-Off Regulating On-Off Regulating A 235 320 250 320 610 610 610 610 765 765 870 870 B 295 265 325 290 280 280 305 305 335 345 405 415 C 180 325 205 345 380 400 395 400 435 400 460 400 D 130 E Weight (kg) 8
QZ15
170
15
QZ45
410
80
35
QZ85
420
110
37
QZ150
500
110
68
QZ300
600
150
95
Note: Pneumatic actuator can be equipped with solenoid valve, filter reducing valve and feed back signal device for valve position, and equipped with protective hood, but it only can be used indoors, 220V AC and 24V DC power supply can be used in solenoid valve. All above requirements must be indicated in your order.
Reference Table for Materials Application: Applicable Temperature () -20 ~ +85 -18 ~ +135 ST 18 ~ +149 -45 ~ +135 ST 30 ~ +149 -7 ~ +93 ST 7 ~ +107 -12 ~ +82 ST 12 ~ +93 -12 ~ +135 ST 12 ~ +149 -30 ~ +350 -273 ~ +232 -268 ~ +316 Applicable Medium Fresh Water Sea Water Salt Strong Alkali Weak Alkali Weak Natural Acid Gas Alcohol Steam Oil Food Features
Material Natural Rubber Hypalon EPDM Seat Neoprene NBR Viton Electric Plating DI Disc Aluminum Bronze Stainless Steel
High Elasticity
Oxidation Resistant
Aging Resistant Light-Proof, Aging Resistant Oil Resistant H. Temp. Resistant, Anti-Corrosion Heat Resistant Heat Resistant, AntiCorrosion H. Temp. Resistant, Anti-Corrosion
Applicable
19
Numbering System: 1 Valve Size 2 Valve Type 3 Actuator 4 Ends 5 Structure 6 Seat 7 Pressure Rating 8 Body Material 9 Disc Material Code Z Q T P R C Code B1 B2 B7 B5
1. Valve Size DN50 (2) DN65 (2-1/2) DN600 (24) 2. Valve Type Butterfly Valve 3. Actuator Handles Worm Gear Electric Actuator Pneumatic Actuator 4. Ends Wafer Wafer, Lug Flanged, Short Body Flanged, Long Body
5. Structure Center Line Disc 6. Seat Natural Rubber Hypalon EPDM Neoprene NBR Abraion-Proof Rubber Viton Heat Resistant EPDM 7. Pressure Rating PN 1.0 MPa PN 1.6 MPa ANSI Class 125 ANSI Class 150
8. Body Material Cast Iron, CI Ductile Iron, DI Aluminum Bronze Stainless Steel CF8 Stainless Steel CF8M Cast Steel, WCB 9. Disc Material Electric Plating DI Aluminum Bronze Stainless Steel, CF8 Stainless Steel, CF8M
Ordering Information: In order to ensure your requirement for usage, please explain in detail in your order: Valve Type, Specification, Material, Nominal Pressure, Working Pressure, and Temperature Used, Max. Flow Rate, Pressure Drop, Medium Composition of valve, Actuator Type and standard for connection of the valve with pipes, etc. For the convenience usage of consumes, our company can provide flange and bolts completed with valves, and will provide wearing parts according to the requirement of consumes. In selection of product types, consumer can present his requirement for product material, connection standard and technical data and give clear declaration in your contract. Our company also can carry out study and development on new product according to requirement of consumer.
20