Mitsubishi F700 VFD Brochure
Mitsubishi F700 VFD Brochure
Mitsubishi F700 VFD Brochure
UL Type 1, Plenum Rated, Enclosure Designs (NEMA 1): Drive can be mounted as a stand-alone unit. BACnet MS/TP protocol built in: Support for other popular BMS systems, including Metasys N2, Siemens FLN, and LonWorks is available. Built in PLC: Uses GX Developer for programming, 4K steps of memory Single Phase Input: UL/cUL Listed for use with Single Phase Input supply. Ease of Programming:Taken to higher levels with the new DU07 programming dial and FR-Configurator programming software.
Parameter Change
The popular setting dial makes operation easy The dials clicking sensation and notch helps make settings with confidence Make settings quickly or slowly depending on how fast the dial is turned Detachable keypad can be panel mounted. (Cable and adaptor required) Hand/Auto indication available with optional FR-PU07-01 keypad Dial/key operation lock function is available
F700LINEUP
The F700 inverter is built to optimize 3-phase motor control, saving energy for virtually all general purpose applications.
Evolution of the inverter for fan and pump applications, providing energy savings for buildings and factories as a whole.
Windmill Start: F700 measures residual motor slot ripple to determine both the speed and direction of rotation of a coasting motor and can swiftly and smoothly bring it under control when required whichever way its spinning. Enhanced Energy Savings: An improved version of Mitsubishi Electrics famous energyoptimization software boosts motor efficiency to unprecedented levels and intelligently maximizes energy savings.
Ex. of Blower Operation Characteristics Power Consumption (%)
100 80
Energy Saving Signal: F700 will calculate and display your energy savings, either as dollars or kW/h.
Power Savings Monitor Display Energy Saving Monitor List
Power saving monitor (kW) Power saving rate (%) Power saving amount (kWh) Power saving amount charge ($) Power saving average value (kW) Power saving rate average value (%) Power saving charge average value ($) Annual power saving amount (kWh) Annual power saving amount charge ($)
Ratio of Motor Power Consumption during Acc./Dec Power Consumption Ratio (%)
Conventional model (FR-F500)
12%
90
100
6%
Energy savings results can be confirmed using the operation panel, output terminal (CA, AM terminal) and via networks with the newly developed energy saving monitor. Power Dip Ride -Through: Allows the inverter to continue to run during short power supply interruptions reducing nuisance tripping.
When power is restored during deceleration
60
40 20
F700
10
20
30
60
10
20
30
40
50
Frequency (Hz)
F700 achieves a higher level of energy savings both during acc./dec. and constant speed operation.
IPF
Reacceleration
Operation continues without the motor coasting when an instantaneous power failure occurs in fan and blower applications.
F700 VFD
Pre-Charge Function: Before PID control takes over, this function can be used to ensure consistent fill. Overvoltage Avoidance: The F700 measures DC bus levels when decelerating and controls drive speed to eliminate nuisance tripping. Programmable Timer: Generates a signal dependent on drive operating time useful to plan scheduled machine maintenance. Independent RS-485 Connections:Allow serial communications and keypad operation at the same time with no options needed. F700 supports Modbus RTU as well as the standard Mitsubishi Electric protocol. Complies with Global Standards: UL, cUL, GOST, JEM, and CE marked for use in Europe. A radio filter is included in the drive as standard to meet European EMC levels (2nd Enviromental). Improved Field Bus Capability: In addition to popular BMS protocols inlcuding Lon Works, Metasys N2 and Siemens FLN, F700 now supports Ethernet I/P, Profibus DP, and DeviceNet. BACnet MS/TP is built-in.
Power supply unit Inverter CPU Master Up to 42 units can be connected Inverter
(
Terminating resistor CC-Link dedicated cable
)
FR-A7NC Terminating resistor
FR-A7NC
CC-Link network
Network management computer
Inverter
Inverter
Air-conditioner
Pump
Advanced PID Mode: Now includes sleep mode as well as pump scheduling feature to allow the intelligent control of up to 4 motors at once. Remote I/O Capability:Drive I/O can be configured over a network to work independently of the drive, reducing cost and making more efficient use of the available network nodes.
FR-A7NL
LONWORKS
Network
Free Topology
FR-A7NL
Node
Node
Lighting
Security system
Standard Specifications
F700 Ratings 240V Class
Input: 1 Phase / 3 Phase Output Voltage: 3 Phase 200-240V at 60Hz Voltage Tolerance: 170-264V at 60Hz Available Braking Torque: 15% Torque Continuous SLD (40C) 110% OL / 1min 120% OL / 3 sec Hp (*1) 1 2 3 5 7.5 10 15 20 25 30 40 50/60 60 75 40 50/60 60 75 100/125 150 200 FLA 4.6 7.7 10.5 16.7 25 34 49 63 77 93 125 154 187 233 125 154 187 233 316 380 475 LD 120% OL / 1min 150% OL / 3 sec Hp (*1) 1 2 3 5 7.5 10 15 20 25 30 40 50 60 75 40 50 60 75 100 125 150 FLA 4.2 7 9.6 15.2 23 31 45 58 70 85 114 140 170 212 114 140 170 212 288 346 432 Model Number (*3) Frame Size Cooling Method Protective Rating
FR-F720-00046-NA FR-F720-00077-NA FR-F720-00105-NA FR-F720-00167-NA FR-F720-00250-NA FR-F720-00340-NA FR-F720-00490-NA FR-F720-00630-NA FR-F720-00770-NA FR-F720-00930-NA FR-F720-01250-NA FR-F720-01540-NA FR-F720-01870-NA FR-F720-02330-NA FR-F720-01250-NAN1 FR-F720-01540-NAN1 FR-F720-01870-NAN1 FR-F720-02330-NAN1 FR-F720-03160-NA FR-F720-03800-NA FR-F720-04750-NA
A B C C C D D E F F F G H H F G H H K K K
Self Cooling
IP00 (*2)
NEMA 1
IP00 (*2)
NEMA 1
DIMENSIONS
Frame Size A B C D E F G Height 10.2 (260) 10.2 (260) 10.2 (260) 10.2 (260) 11.8 (300) 15.8 (400) 21.7 (550)
Dimensions inches (mm) Width 4.3 (110) 4.3 (110) 5.9 (150) 8.7 (220) 8.7 (220) 9.8 (250) 12.8 (325) Depth 4.3 (110) 4.9 (125) 5.5 (140) 6.7 (170) 7.5 (190) 7.5 (190) 7.7 (195)
Frame Size H J K L M N P
Dimensions inches (mm) Height 21.7 (550) 27.6 (700) 29.1 (740) 39.8 (1010) 39.8 (1010) 52.4 (1330) 62.2 (1580) Width 17.1 (435) 18.3 (465) 18.3 (465) 19.6 (498) 26.8 (680) 31.1 (790) 39.2 (995) Depth 9.8 (250) 9.8 (250) 14.2 (360) 15 (380) 15 (380) 17.3 (440) 17.3 (440)
F700 VFD
F700 Ratings 480V Class (continued)
Input:1 Phase / 3 Phase Output Voltage: 3 Phase 380-480V at 50/60Hz Voltage Tolerance: 323-550V at 50/60Hz Available Braking Torque: 15% Torque Continuous DC Link Choke is included with the VFD SLD (40C) LD 110% OL / 1min 120% OL / 3 sec Hp (*1) 100/150 150 200 250 300 350 400 450 500 550 650 700 800 900 1000 FLA 180 216 260 325 361 432 481 547 610 683 770 866 962 1094 1212 120% OL / 1min 150% OL / 3 sec Hp (*1) 100 150 150 200 250 300 350 400 450 500 550 650 700 800 900 FLA 144 180 216 260 325 361 432 481 547 610 683 770 866 962 1094 FR-F740-01800-NA FR-F740-02160-NA FR-F740-02600-NA FR-F740-03250-NA FR-F740-03610-NA FR-F740-04320-NA FR-F740-04810-NA FR-F740-05470-NA FR-F740-06100-NA FR-F740-06830-NA FR-F740-07700-NA FR-F740-08660-NA FR-F740-09620-NA FR-F740-10940-NA FR-F740-12120-NA H J J K K L L M M M N N P P P IP00 Forced Air Cooled IP00 (*2) Model Number (*3) Frame Size Cooling Method Protective Rating
FR-F740-01800-NA 13.4 (340) 5.9 (150) 7.5 (190) FR-F740-02160-NA 13.4 (340) 5.9 (150) 7.7 (195) FR-F740-02600-NA 15.9 (405) 6.9 (175) 7.9 (200) FR-F740-03250-NA 15.9 (405) 6.9 (175) 8 (205)
FR-F740-03610-NA 15.9 (405) 6.9 (175) 9.4 (240) FR-F740-04320-NA 15.9 (405) 6.9 (175) 9.4 (240) FR-F740-04810-NA 17.3 (440) 7.5 (190) 9.8 (250) FR-F740-05470-NA 17.3 (440) 7.5 (190) 10 (255)
FR-F740-06100-NA 19.5 (495) 8.3 (210) 9.8 (250) FR-F740-06830-NA 19.5 (495) 8.3 (210) 9.8 (250) FR-F740-07700-NA 19.7 (500) 8.7 (220) 9.8 (250) FR-F740-08660-NA 19.7 (500) 8.7 (220) 10.6 (270)
FR-F740-09620-NA 17.8 (455) 8.5 (215) 13.6 (345) 67 (1147) FR-F740-10940-NA 18.1 (460) 8.5 (215) 14.2 (360) FR-F740-12120-NA 18.1 (460) 8.5 (215) 14.2 (360) 85 (187) 95 (209)
Notes: 1. Motor ratings shown are intended as guidelines only based on 4 pole standard induction motors. 2. NEMA 1 conduit adapter option required. 3. For single phase input, derate output current by 40% (Models up to F720-03800-NA, F740-04810-NA.)
Option Cards
Model No. Relay Output 12 Bit Digital Input Digital Output Ext. Analog Output BiPolar Analog Input High Res Analog Input Motor Thermistor CC-Link DeviceNet LonWorks Profibus DP Function (two are permissible) FR-A7AR FR-A7AX FR-A7AY
Conduit Attachments
Model Number FR-A7FN05 (*3) FR-A7FN06 (*3) FR-A7FN07 (*3) FR-A7FN-10 (*2) FR-A7FN-11 (*2) FR-A7FN-12 (*2) FR-A7FN-13 (*2) FR-A7FN-14 (*2) Drive Model F720 (*1) F740 (*1) 01250 01540 01870, 02330 03160, 03800, 04750 00770 00930, 01160 01800 02160, 02600 03250, 03610 04320, 04810 05470, 06100, 06830 Length (in) (*4) 5.9" 6.2" 9" 24" 24" 24" 26" 26" Weight (lbs) 5 5 15 37 41 45 50 64
Notes: 1. For FR-F700s smaller than listed above, they are UL Type 1, and conduit attachment is standard. 2. Mounting hardware included for standard DCchokes which ship with VFD. Kits are powder coated similar to VFD, charcoal gray. 3. Kits are coated zinc clear. 4. Width and depth of kit match the asscociated VFD.
Communication
Control System Output Frequency Range Frequency Setting Resolution Frequency Accuracy Starting Torque Acceleration/Deceleration Time Setting DC Injection Brake Stall Prevention Operation Level Frequency Setting Signal Start Signal Analog Input Digital Input Analog Input Digital Input Analog Input Digital Input
High carrier frequency PWM control (V/F control)/optimum excitation control/simple magnetic flux vector control 0.5 to 400Hz 0.015Hz/0 to 60Hz (terminal 2, 4: 0 to 10V/12bit); 0.03Hz/0 to 60Hz (terminal 2, 4: 0 to 5V/11bit, 0 to 20mA/approx. 11bit, terminal 1: -10V to +10V/11bit); 0.06Hz/0 to 60Hz (terminal 1: 0 to 5V/10bit) 0.01Hz Within 0.2% of the max. output frequency (25C 10C) Within 0.01% of the set output frequency Base frequency can be set from 0 to 400Hz. Constant torque/variable torque pattern or adjustable 5 points V/F can be selected. 120% (3Hz) when set to simple magnetic flux vector control and slip compensation 0 to 3600s (acceleration and deceleration can be set individually), linear or S-pattern acceleration/deceleration mode can be selected Operation frequency (0 to 120Hz), operation time (0 to 10s), operation voltage (0 to 30%) variable Operation current level can be set (0 to 150% adjustable), whether to use the function or not can be selected Terminal 2, 4: 0 to 10V, 0 to 5V, 4 to 20mA can be selected. Terminal 1: -10 to +10V, -5 to 5V can be selected. Four-digit BCD or 16-bit binary using the setting dial of the operation panel (when used with the option FR-A7AX) Available individually for forward and reverse rotation. Start signal automatic self-holding input (3-wire input) can be selected. Select any twelve signals using Pr.178 to Pr.189 (input terminal function selection) from among multi-speed selection, second function selection, terminal 4 input selection, JOG operation selection, selection of automatic restart after instantaneous power failure, external thermal relay input, HC connection (inverter operation enable signal), HC connection (instantaneous power failure detection), PU operation/ external interlock signal , PID control enable terminal, PU operation, external operation switchover, output stop, start self-holding selection, forward rotation command, reverse rotation command, inverter reset, PTC thermistor input, PID forward reverse operation switchover, PU-NET operation switchover, NET-external operation switchover, command source switchover. Maximum and minimum frequency settings, frequency jump operation, external thermal relay input selection, polarity reversible operation, automatic restart after instantaneous power failure operation, continuous operation at an instantaneous power failure, commercial power supply-inverter switchover operation, forward/reverse rotation prevention, operation mode selection, PID control, computer link operation (RS-485). Select any seven signals using Pr.190 to Pr.196 (output terminal function selection) from among inverter running, up-to-speed, instantaneous power failure/undervoltage, overload warning, output frequency detection, second output frequency detection, electronic thermal relay function pre-alarm, PU operation mode, inverter operation ready, output current detection, zero current detection, PID lower limit, PID upper limit, PID forward rotation reverse rotation output, commercial power supply-inverter switchover MC1, commercial power supply-inverter switchover MC2, commercial power supply-inverter switchover MC3, fan fault output, heatsink overheat pre-alarm, inverter running start command on, deceleration at an instantaneous power failure, PID control activated, during retry, during PID output suspension, life alarm, input MC stop signal, power savings average value update timing, current average monitor, alarm output 2, maintenance timer alarm, remote output, minor failure output, alarm output. Open collector output (5 points), relay output (2 points) and alarm code of the inverter can be output (4 bit) from the open collector. Select any seven signals using Pr. 313 to Pr. 319 (extension output terminal function selection) from among control circuit capacitor life, main circuit capacitor life, cooling fan life, inrush current limit circuit life. Select from output frequency, motor current (steady or peak value), output voltage, frequency setting value, running speed, converter output voltage (steady or peak value), electronic thermal relay function load factor, input power, output power, load meter, reference voltage output, motor load factor, energy saving effect, PID set value, PID process value using Pr. 54 FM terminal function selection (pulse train output) and Pr. 158 AM terminal function selection (analog output). Output frequency, motor current (steady or peak value), output voltage, alarm indication, frequency setting, running speed, converter output voltage (steady or peak value), electronic thermal load factor, input voltage, output voltage, road meter, cumulative energization time, actual operation time, motor load factor, cumulative energization power, power saving effect, cumulative saving power, PID set point, PID process value, PID deviation value, inverter I/O terminal monitor, input terminal option monitor (*1), output terminal option monitor (*1), option fitting status monitor (*2), terminal assignment status (*2) Alarm definition is displayed when the protective function is activated, the output voltage/current/frequency/cumulative energization time right before the protection function was activated and the past 8 alarm definitions are stored. Operation guide/trouble shooting with a help function (*2) Overcurrent during acceleration, overcurrent during constant speed, overcurrent during deceleration, overvoltage during acceleration, overvoltage during constant speed, overvoltage during deceleration, inverter protection thermal operation, heatsink overheat, instantaneous power failure occurrence, undervoltage, input phase failure, motor overload, output side earth (ground) fault overcurrent, output phase failure, external thermal relay operation, PTC thermistor operation, option alarm, parameter error, PU disconnection, retry count excess, CPU alarm, power supply short for operation panel, 24VDC power output short, output current detection value over, inrush resistance overheat, communication alarm (inverter), analog input alarm, internal circuit alarm (15V power supply), fan fault, overcurrent stall prevention, overvoltage stall prevention, electronic thermal prealarm, PU stop, maintenance timer alarm (*1), parameter write error, copy operation error, operation panel lock. -10C to +50C (non-freezing) 90% RH or less (non-condensing) -20C to +65C Indoors (without corrosive gas, flammable gas, oil mist, dust and dirt, etc.) Maximum 1000m above sea level, 5.9m/s2 or less (conforms to JIS C 0040) 1. Can be displayed only on the operation panel (FR-DU07). 2. Can be displayed only on the parameter unit (FR-PU04). 3. Temperature applicable for a short period in transit, etc.
Voltage/Frequency Characteristics
Input Signals
Operational Functions
Output Signals
Operating Status
Pulse/Analog Output
Operating Status PU (FR-DU07/ FR-PU04) Alarm Definition Interactive Guidance Display Environment
Protective/Warning Function
Ambient Temperature Ambient Humidity Storage Temperature (*3) Atmosphere Altitude, Vibration Notes:
Mitsubishi Electric Automation, Inc. 500 Corporate Woods Parkway Vernon Hills, IL 60061 Phn: (847) 478-2100 Fax: (847) 478-2253 www.MEAU.com | Serving the Americas
Printed with soy inks. L-VH-04030 Effective March, 2011. Specifications subject to change without notice. 2011, Mitsubishi Electric Automation, Inc.