Design of Horizontal Bracing
Design of Horizontal Bracing
( Tc = 0.45 x Fy x A )
Design for 75 % Axial capacity = 116.4375 kN A) Connection Type-1 ( Bolted Conn.) Alternative Grade of Bolts = Dia of Bolts, db = Total Nos of bolts (n)= Tensile Stress, Ft = Shear Stress, Fv = Shear Check V = Max ( P or 75 % T ) / n Shear per bolt, V = Weld length Calculations sw = Weld Thkness, tw = 6.0 mm Length Reqd, lw = P / ( sw x 0.707 x t ) lw Req.= 275 mm Weld Prov. = 2x(90+25+50+50) Weld Prov. = 420 mm Weld Provide is OK A) Profile Welded Connection Weld length Calculations sw = Weld Thkness, tw = 6.0 mm Length Reqd, lw = P / ( sw x 0.707 x t ) lw Req.= 275 mm Lw = 2x(90+74) Weld Prov.Lw = 328 mm Weld Provide is OK 100 N/mm2 100 N/mm2 58.22 kN < Shear Capacity, OK 8.8 24 mm 2 286 N/mm2 191 N/mm2 Root Area of Bolt = Capacity of Bolt Tension, Tc = Shear, Vc =
2 366.58 mm
104.84 kN 70.02 kN