NEC PASOLINK Training
NEC PASOLINK Training
NEC PASOLINK Training
3.6-7.1
7.1-8.5
17.7-19.7
21.2-23.6
24.2-27
37-40
PASOLINK V3
PDH
4PSK
2x2MB 4x2MB 8x2MB 16x2MB 1x8MB 1x34MB 2x2MB 4x2MB 8x2MB 16x2MB (2x10/100Base-T) 8x2MB 16x2MB 1 x 34MB
PASOLINK V4
PDH
4PSK
PASOLINK+
PDH
16QAM + RS
System Overview
NEC has developed the PASOLINK NEO, a narrow band point-to-point digital microwave relay system operating at radio frequency (RF) bands of 6/7/8/11/13/15/18/23/26/28/32/38/52 GHz. The PASOLINK NEO system provides interface types of PDH, SDH and LAN. The transmission signals are 5 to 48 x E1, 1 to 2 x E3, 1 to 2 x STM-1, 2/4 x 10/100 Base-T(X) and GbE signals.
The systems consist of antennas, outdoor unit (ODU) and Indoor unit (IDU) same as PASOLINK series. They are connected through a coaxial cable for each radio channel. Available configurations are non protected type (1+0) and protected type (1+1). The protected type is available for twin-path type and hot-standby type.
System Composition
1- Indoor unit (IDU) ( Modulation-Demodulation unit) 2- Outdoor unit (ODU) ( Transmit Receive unit) 3- IF cable and connectors ( To connect the IDU & ODU) 4- Antenna on the required microwave band 5- Hybrid ( coupler ) in case of 1+1 one antenna configuration 6- RF cable ( If the ODU is not direct mounted to the antenna)
ODU (low band) TX/RX RF IF RX Antenna TX Antenna RF IF
TX
RX
MODEM IDU
Base Band
MODEM IDU
Base Band
System Configuration
A- Non protected system (1+0)
TX IDU ( 1+0 ) ODU RX RX TX ODU IDU ( 1+0 )
System Configuration
C- Protected system (1+1) hot standby Space diversity Double antenna configuration
TX/RX ODU-1 Modem-1 Switch Modem-2 TX Rx only ODU-2 RX RX RX RX TX TX/RX ODU-1 Rx only ODU-2 Modem-1 Switch Modem-2
PASOLINK NEO
Bit rate Free: 5/10/16/20/40/48E1, STM-1/2xSTM-1 Modulation Free : 4PSK,16/32/128QAM Flexible Interface : PDH/SDH/LAN
Equipment Features
1. Advanced Technologies and Superb Performance High reliability and Quality. Excellent field proven MTBF. Low power consumption. 10 Base-T/100 Base-TX, 1000 Base-SX, 1000 Base-T (LAN interface). APS for STM-1 optical. VLAN implementation. 2. High System Gain / High spectrum efficiency
High System Gain achieved by each modulation with Forward Error Correction (FEC) Technology and distortion canceling technique called linearizer. High spectrum efficiency achieved by QPSK to 128QAM selectable technology. Allowing smaller antennas and reducing system cost. 3. Easy and Quick Installation
IDU - ODU Interconnection : Only one coaxial cable and automatic equalization. Very Compact and Light. Various mounting methods for IDU, ODU and Antenna. Easy Antenna direction adjustment.
Equipment Features
4. Frequency Agility and Easy Tuning Field tunable local oscillator (Synthesizer) RF point frequency can be changed through Local Craft Terminal (LCT). Sub-band of type is changeable by replacing RF Filter. 5. System Flexibility
(1+0) Non-protected or (1+1) Protected. 1+1 Hot Standby / Space Diversity / Twin Path System available. IDU is used commonly for 6 - 52 GHz. Changeable data transmission rate (4 to 48x2 Mbps, 1 to 2x34 Mbps, 155 Mbps, 2x155 Mbps, 10/100 Base-T(X), 1000 Base-SX, 1000 Base-T) at the same IDU. Software settable Modulation (QPSK/16QAM/32QAM/128QAM) of IDU. Common ODU for PDH/SDH/LAN. Wide Input Line Voltage range is -40.5 to -57Vdc. 6. Maintenance Facilities
Local and remote supervision function on IDU through LCT or PNMTj Full front access at IDU for all cabling and user interface Loop back facility Near end base band, Far end base band IF loop back Pre-settable BER alarm point: 10-3, 10-4 or 10-5
Equipment Feature
7. Service Channels Engineering Order Wire (OW): IDU- IDU and Party line.
SC1 & SC 2: V.11, 64 Kbps Contra-Co directional : Selectable SC3 & SC 4: RS232C , 9.6 Kbps SC LAN : SC LAN Sub-Interface ( In case of 155 MB Capacity ) 64/128/192/265 Kbps or 2 Mbps Throughput. SV Channel commonality:
SV Commonality
ODU
Bitrate Free 5/10/20/40/48E1 STM-1 STM-2(310MB) Modulation Free 4PSK,16/32/128QAM
IDU
Interface Board
System Upgradeability
ODU
1+0
ODU
5E1 10E1 16E1 Upgrade Key New MODEM New INTF +New ODU +Upgrade Key
ODU ODU
1+1
ODU
Repeater
V ODU H ODU
STM-1
2xSTM-1/XPIC
Memory Card
Working Line
Protection Line
SDH MUX
Working Line
Protection Line
IDU
ODU 1
V
ODU 1
IDU
OMT
OMT
IDU
ODU 2
ODU 2
IDU
Switchover Control
1.
Switchover Modes:
Automatic Switchover: Switching is automatically initiated if any failure or abnormality was detected in the online section. Manual Switchover: The operator initiate this switchover by LCT or PNMT for the maintenance and test purposes. The manual switching has two selection Manual or Forced switchover.
2.
Switching Priority:
The switching priority is only applied under automatic switching control.
6
5.9255.9257.125
7-8
7.1257.1258.5
11
10.710.711.7
13
15
18
17.717.719.7
23
21.221.223.6
26
24.2524.2527.0
28
27.527.529.5
32
31.831.833.4
38
37.037.040.0
52
51.451.452.6
N/A
NEC Original
PBR 260 PBR 320 PBR 320 PBR 320 N/A
N Type or N Type or PDR100 PBR120 PBR140 PBR 220 PBR 220 PDR 70 PDR 84
+29
+25
+25
+23
+24
+24
+23
+23
+22 0 to 25 dB
+18
+3 0 to 10 dB
0 to 30 dB 6 ppm (dBm measured at Antenna port) BER = 10 -6 -83 -86 -89 -83.5 -86.5 -89.5 -83.5 -86.5 -89.5 -83.5 -86.5 -89.5 -83 -86 -89 -83 -86 -89
7-8
11
13
15
18
23
26
28
32
38
52
(dBm measured at Antenna port) BER = 10 -6 108 111 114 106.5 109.5 112.5 107.5 110.5 113.5 107.5 110.5 113.5 106 109 114 106 109 114 103.5 106.5 109.5 99.5 102.5 105.5 81 84 87
Above value with +1.5 dB -15 dBm (No Error) Less than 10-12 at RSL = -30 dBm
6
5.9255.9257.125
7-8
7.1257.1258.5
11
10.710.711.7
13
12.7512.7513.25
15
14.214.215.35
18
17.717.719.7
23
21.221.223.6
26
24.2524.2527.0
28
27.527.529.5
32
31.831.833.4
38
37.037.040.0
N/A
N Type or N Type or PDR 100 PBR 120 PBR 140 PDR 70 PDR 84 PBR 220
NEC Original
PBR 220 PBR 260 PBR 320 PBR 320 PBR 320
+25
+21
+21
+21
+19
+19
+18
+18
+17
+13.5
Above value with +1.5 dB (dBm (dBm measured at Antenna port) BER = 10 -6 97 100 97.5 100.5 95.5 98.5 95.5 98.5 95.5 98.5 94 97 94 97 91.5 94.5 89 92
6
108 111
7-8
11
103 106
13
103.5 106.5
15
101.5 104.5
18
101.5 104.5
23
101.5 104.5
26
100 103
28
100 103
32
97.5 100.5
38
95 98
Above value with +1.5 dB -20 dBm for the BER less than 1010-3 Less than 10-12 at RSL = -30 dBm
6
5.9255.9257.125
7-8
7.1257.1258.5
11
10.710.711.7
13
15
18
17.717.719.7
23
21.221.223.6
26
24.2524.2527.0
28
27.527.529.5
32
31.831.833.4
38
37.037.040.0
52
51.451.452.6
N/A
NEC Original
PBR 260 PBR 320 PBR 320 PBR 320 N/A
N Type or N Type or PDR100 PBR120 PBR140 PBR 220 PBR 220 PDR 70 PDR 84
+25
+21
+21
+21
+19
+19
+18
+18
+17
+14.5
-3 0 to 6 dB
0 to 30 dB 6 ppm (dBm measured at Antenna port) BER = 10 -6 -74.5 -75 -75 -75 -74.5 -74.5 -73 -73
-69.5
Above value with -1.5 dB (dBm measured at Antenna port) BER = 10 -6 95.5 96 94 94 92.5 92.5 90 87.5 66.5
Above value with +1.5 dB -20 dBm for the BER less than 1010-3 Less than 10-12 at RSL = -30 dBm
6
5.9255.9257.125
7-8
7.1257.1258.5
11
10.710.711.7
13
12.7512.7513.25
15
14.214.215.35
18
17.717.719.7
23
21.221.223.6
26
24.2524.2527.0
28
27.527.529.5
32
31.831.833.4
38
37.037.040.0
N/A
N Type or N Type or PDR 100 PBR 120 PBR 140 PDR 70 PDR 84 PBR 220
NEC Original
PBR 220 PBR 260 PBR 320 PBR 320 PBR 320
+25
+25
+21
+21
+21
+19
+19
+18
+18
+17
+14.5
Above value with -1.5 dB (dBm measured at Antenna port) BER = 10 -6 89.5 90 88 88 86.5 86.5 84 81.5
Above value with +1.5 dB -20 dBm for the BER less than 1010-3 Less than 1010-12 at RSL = -30 dBm
SDH
1+0 Expandable / 1+1
LAN QPSK/16/32/QAM 10/100 Base-T(X) 1000 Base-SX 1000 Base-T 2/4 10/20/40/80/100/ 100+50/, 75+75 Mbps
128 QAM STM-1 : 155.52 Mbps 20 ppm 1/2 155/ 2x155 Mbps
20 ppm 1/2
34/68 Mbps
4 5 6 7
Service Channels LCT Security Levels Loop Back BER ALM Frequency Changing TX Output Control PMON
V.11(Contra/Co-directional) x 2 channels,RS-232 x 2 channels 2 levels Near End, Far End Baseband Loop Back and IF Loop Back Adjustable 10-3/ 10-4/ 10-5 Direct entry or Table Download entry :Available Manual Control, Automatic Control and Mute Control. PMON Items; a) OFS, b) BBE, c) ES, d) SES, e)SEP, f) UAS
SDH
LAN
Metering Items a) Output power level (TX PWR), b) Received signal level (AGC V) c) Bit error rate (BER MON) LAN monitoring Items; a) RX Unicast, b) RX Broadcast, c) RX Multicast, b) d) RX Pause, e) RX CRC error
LED Display
CTRL
IDU Alarm (Red) Maintenance (Yellow) Memory Access (Yellow) Operating PWR (Green) ODU Alarm (Red) MD/CBL Alarm (Red) TX status (Green) RX status (Green) XPIC Reset (Yellow) for XPIC only Module alarm (Red) Module alarm (Red) Online (Green) for APS only Module alarm (Red)
MODEM
SPECIFICATION
Single Coaxial Cable per system / 50 ohms 5D-FB, 8D-FB (standard) 10D-FB IF signal, alarms, control, monitoring and power source 150 m (5D-FB) 300 m (8D-FB) 350 m (10D-FB) Automatic level equalization 33oC to +50oC (workable : -40oC to +55oC)
5 6
Notes:
The Factory setting The HK that cane be configured The relays RL1 & RL2 cant be changed
IDU Composition
IDU Shelf :
IDU Modules
H2930 MDPMDP-150MB150MB-1AA No. UNIT/MODULE NAME 1+0 Expandable 1+1 System Remarks
1 2 3
H2931 RACK H2940 MODEM H2940 MODEM H3040 DC-DC CONV H2960 STM-1 INTFC H2965 LAN/WS INTFC H3021 GbE INTFC H2960 STM-1 INTFC H2965 LAN/WS INTFC H2980 16E1 INTFC H3000 48E1 INTFC H3010 E2 INTFC H2950 CTRL
Usually Provided Optionally provided
QPSK/16QAM/32QAM/128QAM -20 to 60 VDC STM1-E/O-S-1.1/L-S-1.1 SDH 2-Port-LAN SDH-GbE STM1-E/O-S-1.1/L-S-1.1 for APS WS-SC-LAN/WS/SC-LAN PDH-16E1 e/w 2 Port LAN PDH-48 E1 PDH-E3 e/w 4/8E1, 2 Port LAN
6 7
Baseband Interface
BaseBand Interface
48 E1 Interface
up to 48 E1 signals 2.048 Mbps +/- 102.4 bps HDB3 75 ohms unbalanced or 120 ohms balanced
BaseBand Interface
16 E1 Interface
2M IN/OUT-A/-B/-C Input/Output Signals: Bit Rate: Code: Impedance: PORT 1/PORT 2 (RJ-45)
8 E1 interface in each connector. up to 48 E1 signals 2.048 Mbps +/- 102.4 bps HDB3 75 ohms unbalanced or 120 ohms balanced LAN interface port 1 and port 2 are separated. 8 to 40 Mbps shared when 16 E1 to 0E1 are used. 10/100 base-T(X) Auto sensing or fixed Full duplex or Half duplex Store and Forward
BaseBand Interface
16 E1 Interface
BaseBand Interface
STM-1 Electrical Interface
STM-1 Interface
Electrical STM-1 PUT/OUTPUT, G.703 155.520 Mbps 1 Vp-p CMI 75 ohms, unbalanced
ALM: To indicate any ALM action occurred in the Interface LOS of STM-1 detected from the DTE or from DMR. Frame Synchronization of input signal is lost BER is worse than ( 10-3~10-5 selectable ) DMR or MUX BER is worse than ( 10-5 ~ 10-9 selectable ) DMR or MUX Mounted module is not matched with the inventory STM-1 IN/OUT LC Type: Rate: Code: Wavelength: Level: Optical STM-1 INPUT/OUTPUT, G.957 155.520 Mbps NRZ 1310 nm L-1.1: 0 to -8 dBm (TX) / -10 to -34 dBm (RX) S-1.1: -8 to -15 dBm (TX) / -8 to -28 dBm (RX)
Working in APS: ONLINE ON SYANDBY APS: ONLINE OFF NO APS: ONLINE OFF
MODEM Unit
The MODEM provides the QPSK/16QAM/32QAM/128QAM Modulation and Demodulation for E1/E3 (PDH), 10/100 base-T (LAN), or STM-1 (SDH) data transmission in addition to the following main functions: Forward Error Correction using RS/Interleaving. XPIC ODU Synthesizer synchronization control. Interfered signal from opposite polarization cancellation ( XPIC ). IDU/ODU Power Supply. System Power On/Off.
Interfaces/Switches/Indications
XIF IN/XIF OUT Only used for XPIC system IF Signal of opposite polarization. IF Signal for opposite polarization output. 140 MHz 75 ohms ( D-SUB 15 pins) Serial Port Only used for XPIC system between two IDUs. ( MOLEX M5557-4R, 4pins) , ( DC IN) -48VDC(negative ) , + (positive, Ground) Ground Terminal( 5mm2 cable) Tx Frequency: 340 MHz Rx Frequency: 140 MHz Impedance : 50 ohms Connecting IF Cable length:
5D-FB: less than 150 m 10D-FB: less than 300 m 12D-FB: less than 350 m
PWR Switch PWR MD/CBL TX ( only 1+1 ) RX (only 1+1 ) XPIC RESET ODU
IDU/ODU Turn Power on To indicate the power switch of the MODEM is turned on. Blinks when IF cable is short circuit. Selected status of ODU TX Selected status of MDOEM RX output signal XPIC function is off condition To indicate any alarm occurred at ODU Circuit.
Power Supply
Power Supply
When the ODU which connected is not NEO connected to IDU NEO, it is recommended to install the optional DC-DC CONV into the IDU. The ODU will be shorten ODUs life or may be damaged if not used optional DC-DC CONV module.
CTRL Unit
CALL PROTECT
Transmit the EOW calling to sound the BUZZER in the opposite station Prevent service interruption in case of CTRL module replacement. EOW Jack for OW headset
LCT
LCT and PNMT Interface USB 1.1 Connector Type B PNMS Interface 10 Base-T RJ-45 Back to Back Connection 10 Base-T RJ-45
SC IN/OUT DSC1 V.11 64 Kbps DSC2 V.11 64 Kbps DSC3 RS232C 9.6 Kbps DSC4 RS232C 9.6 Kbps NE2 RS485 ASYNC.
NMS
NE
RX LEV MONITOR Turn OFF the DC power before removing the IF cable Frame Ground
The nominal power supply voltage is -48 V DC. However, the range of the unit is able to fit for nominal voltages of +24 V by additional unit. The weight of ODU is 3 Kg.
The transmitter-receiver is designed to handle an 8-155 Mbps digital signal in the 6-52 GHz bands. The equipment is designed to withstand severe weather conditions. To achieve high system gain performance, quadrature phase-shift keying (QPSK) modulation is applied. And to achieve high frequency efficiency performance, 16/32/128-quadrature amplitude modulation (16/32/128QAM) is applied. This ODU can apply to each modulation. Advanced integrated circuit technology, e.g., MMIC and MIC, is applied to the entire RF circuit in ODU.
Outdoor Unit
Hybrid Combiner
NEC has developed Hybrid Combiner/Divider over the full range of microwave frequencies for PASOLINK Series digital microwave radio pointpoint-toto-point fixed wireless systems. This Hybrid Combiner/Divider comprises comprises directional coupler, antenna interface, radio mounting interfaces and polarizers. polarizers. The RF signal power received by the single polarized antenna is is equally distributed and sent to two outdoor units through the Hybrid Combiner/Divider for 1+1 protected protected systems. There are two types of NEC Hybrid Combiner/Divider, one is coaxial coaxial cable connection type for 6/7/8 GHz Bands and the other is WG connection type for 11 52 GHz Bands. NEC Hybrid Combiner/Divider is suited for Andrew or RFS Antenna, and all NEC ODUs.
10 Coupler
The RF signal power received by the single polarized antenna is unequally distributed to two outdoor units in the ratio of 9 to 1 through the 10 dB Coupler for 1+1 protected systems. Using this 10 dB Coupler, regular side signal level could be kept higher than in using 3 dB equal Combiner/Divider. There are two types of NEC 10 dB Coupler; one is coaxial cable connection type for 6/7/8 GHz bands and the other is WG connection type for 11 - 38 GHz Bands. NEC 10 dB Coupler is suited for Andrew or RFS Antenna, and all NEC ODUs.
ODU
Antenna
11 - 52 GHz Direct Mounting of the 1+1 PASOLINK ODU (One Antenna with Hybrid Combiner unit)
6/7/8 GHz Remote Mounting of 1+1 PASOLINK ODU with Hybrid Combiner and one antenna
6/7/8 GHz Remote Mounting of 1+1 PASOLINK ODU with two antennas
6/7/8 GHz Remote Mount Dual Pol. System 11 - 38 GHz Remote Mount Dual Pol. System
PASOLINK MONITOR
Meter Indicates the Receive level as a dc voltage OW Indicator Lights when the OW-ON/OFF switch is set to ON. Under this condition if the indicator is not lit replace the battery.
OW ON/OFF SW when set to ON enables OW communication between the IDU and the ODU. VOL control Adjust the level of the OW RX signal.
Head set Jack connects the headset for OW communication RX LEV/OW IN connector connect the OW/RX Lev monitor to the ODU using the provided coaxial cable
(d)
(a) STM-1 near-end loopback (STM-1 LB1) at the 150M INTFC/OPT INTFC module (b) STM-1 far-end loopback (STM-1 LB2) at the 150M INTFC/OPT INTFC module from LCT (c) IF loopback (IF-LB) at the MODEM module (Local only) (d) STM-1 far-end loopback (STM-1 LB2) at the 150M INTFC/OPT INTFC Module from PNMT/PNMS Note: While the IF loopback is in execution, monitoring of the opposite and the subsequent stations from the PNMS and PNMT are disabled.
Confirm 19" Rack Location & DC-Power Source 19"rack rackfixing fixing 19" IDU Mounting
NESIC CAIRO
UNPACKING IDU
Open the carton take out the Accessories Carton Take out the cushioning materials of the IDU Carton Take out the IDU with the antistatic bag from the carton Take out the IDU from the antistatic bag Inspect IDU
IDU MOUNT
FRONT POSITION
More than one rack unit
WALL
Align the IDU to the mount position Fix each side of the IDU to the rack with (M5) screws When mounting the IDU in a 19 inch rack, leave a space of 200mm to the rear section and space of one rack unit to the top and bottom.
CENTER POSITION
More than one rack unit Mount the two brackets to the IDU with four screws Align the IDU to the center mount position and fix each side with (M5) screws
Power Cable
Socket Contact
1 2
2- Set the socket contact to the following position onto the hand crimping tool Crimping Type dia. of Cable 57026-5000 1.5 to 1.8 1.8 to 2.2 57027-5000 2.3 to 2.6 2.6 to 3.1 Position 1 2 1 2
3- Squeeze the handle of the hand crimping tool, insert cable into socket contact
4- Cable should fit, so insulation and bare wire are arranged as shown,
5- Squeeze the handle of the hand crimping tool until ratchet is released.
5-Squeeze the handle of the hand crimping tool until ratchet Is released
6- Insert socket contacts to power connector till they locked and be sure it is well fixed.
(-48 V)
(0 V)
NESIC CAIRO
IFConnector Connector IF
Removethe theODU ODU Remove cover,Confirm Confirmthe the cover, Polarity Polarity
ODU Mounting
UNPACKING ODU
6/7/8 GHz ODU Open the carton Take out the ODU with cushioning materials Remove the cushioning materials from the ODU Take out the ODU from the antistatic bag Inspect ODU
11- 38 GHz ODU Open the carton Take out the ODU with the cushioning materials Remove the cushioning material from the ODU Inspect ODU
V /H POLARIZATION (1+1)
V - POLARIZATION
SCREWS
NEC Hybrid
Quasar Hybrid
SCREWS
SCREWS
H - POLARIZATION
PROCEDURE FOR SETTING V/H POLARIZATION USING HYBRID ANTENNA SIDE Loosen the four screws with allen keys and rotate the antenna connection unit to the required polarization position Tighten the four screws. HYBRID SIDE The hybrid is set to V-polarization when shipped from the factory Remove the two screws. Rotate the two plates to the position required for the required polarization and fix them in position with the screws
When vertical polarization is required, rotate the IDU so that the plate marked with V is pointing up. Fix the ODU in this position
When horizontal polarization is required, rotate the IDU so that the plate marked with H is pointing up. Fix the ODU in this position
USE OF O-RINGS
ODU MOUNT
Hardware Requirement:
H.D.D: 100MB or higher empty disk capacity RAM: 256 MB Display: LCD 1,024 x 768 CD-ROM Drive Serial Port USB Port USB Cable with USB-B Connector
Software Requirement:
OS: Windows 2000/XP IE6.0 SP2 Java Runtime Environment V1.5.0_05 or higher
LCT Operation
Connect to the USB port of IDU using the USB cable Connect using the dial up connection LCT. Open the Internet Explorer Enter URL Address: http://172.17.254.253 of the IE and press the Enter key. The login window will then enter your login information User ID and password in the entry field then press login
LCT Operation
Description of LCT Menu Convections
To execute the commands To logout from the LCT Then a confirmation Message will appear to Confirm or cancel. To show the status of Command execution if OK Or no response.
For QPSK
For 16QAM
For 32QAM
Edit the point of TX frequency which should be within the range of the Start and Stop Sub-band indicated on the plate of the ODU. The Rx frequency is automatically calculated According to the Shift frequency. For Twin path systems, two different RF Frequencies should entered. ID1 to ID16 is available and ID17 to ID32 is Available for XPIC system.
Inventory
Inventory
Select Open or Close to apply to the output mode to apply for event output. From INPU1 to INPUT6 can be assigned as housekeeping Alarm HK1 to HK6. From INPUT3 to INPUT6 can be assigned as Input Cluster Alarm Cluster IN1 to Cluster IN4. From OUTPUT1 to OUTPUT4 can be assigned as HK3 to HK6. From OUTPUT1 to OUTPUT4 can be assigned as Cluster OUT1 to OUT4. Cluster can be used as IN + OUT 4 Click SET Command to execute.
Maintenance
PDH Maintenance
Maintenance
SDH Maintenance
Maintenance
Select CTRL for IDU or ODU for No.1 or No.2 and click the execute button. Check With ROM Program Switching Control box when the program file for CTRL Or ODU is newly downloaded and existing Program file will be replaced with the new one. Reset the CTRL card will affect the radio link
Maintenance
Maintenance
Provisioning (1/4)
PDH Provisioning
Provisioning (2/4)
PDH Provisioning
ATPC MODE
MTPC MODE
Provisioning (3/4)
SDH Provisioning
ATPC MODE
MTPC MODE
Provisioning (4/4)
Provisioning
Metering
PMON (History)
PMON (History)
PMON (History)
PMON (History)