Setting Bolt Calculation

This document summarizes the calculation of anchor bolts needed to support an operating weight of 3540 kg that will produce a bending moment of 1310.6 Nm. It determines that 4 anchor bolts of size M24 with an area of 3.3826 cm^2 each would be sufficient, as the area required per bolt is only 0.525 cm^2, well below what the M24 bolt can provide. All stress limits and sizes are verified to support the given weight and moment.

Uploaded by

rina2393
Copyright
© © All Rights Reserved
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
214 views

Setting Bolt Calculation

This document summarizes the calculation of anchor bolts needed to support an operating weight of 3540 kg that will produce a bending moment of 1310.6 Nm. It determines that 4 anchor bolts of size M24 with an area of 3.3826 cm^2 each would be sufficient, as the area required per bolt is only 0.525 cm^2, well below what the M24 bolt can provide. All stress limits and sizes are verified to support the given weight and moment.

Uploaded by

rina2393
Copyright
© © All Rights Reserved
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 1

Setting/ Anchor Bolt Calculation

Operating Weight,
Bending moment,
Bolt Center Diameter,
Material
Allowable Stress,
Bolt Size
Area
Lugs Quantity

W =
M=
Rlug =
=
Sb =
=
Ab =
Nlug =

3540
kg
= 34692
N
1310.6 Nm
1592
mm = 1.864
m
SA-193 B7
2
172
MPa = 1753.912 kgf/cm
M24
2
3.3826 cm
4

Force on one lug, operating condition (Flug)

Flug

M lug
W
= 9024.545 N

N lug
( Rlug N lug / 2)
= 920.2473 kgf

Required area per bolt

Flug

2
0.525 cm

Sb

The area provided by specified setting bolt (3.3826 cm 2) is adequate