ALV FM Parameters
ALV FM Parameters
ALV FM Parameters
This is a discussion on ALV reporting-a step by step operation manual about creating an ALV report of medium complexity.
This documentation will not make you an expert in ALV. But, definitely, it will come handy at the time of need. It refers an
example report YSUBALV, as a reference and will represent relevant blocks of the code at different areas of discussion.
Contents
ALV (ABAP LIST VIEWER)
Step 1: DATA DECLARATION
Example:
Step 2: Selecting the variants(Optional)
Step 3: (Defining Output Characteristics)
Step 4: (Build up events table)
Step 5: (Report Output list description)
Step 6: (Pass Selection-screen Information)
Step 7: (Deciding Sort Criteria)
Step 8: (Final Step)
REUSE_ALV_VARIANT_DEFAULT_GET
2.
REUSE_ALV_VARIANT_F4
3.
REUSE_ALV_VARIANT_EXISTENCE
4.
REUSE_ALV_EVENTS_GET
5.
REUSE_ALV_COMMENTARY_WRITE
6.
REUSE_ALV_FIELDCATALOG_MERGE
7.
REUSE_ALV_LIST_DISPLAY
8.
REUSE_ALV_GRID_DISPLAY
9.
REUSE_ALV_POPUP_TO_SELECT
The different steps used for getting the above function modules into use are described below.
TYPE SLIS_LAYOUT_ALV,
I_FIELDTAB
TYPE SLIS_T_FIELDCAT_ALV,
I_HEADING
TYPE SLIS_T_LISTHEADER,
I_EVENTS
TYPE SLIS_T_EVENT.
TYPE SLIS_LAYOUT_ALV.
Data: STRUCT_LAYOUT1
TYPE SLIS_LAYOUT_ALV.
TYPE SLIS_T_EVENT.
TYPE SLIS_T_FIELDCAT_ALV.
Data: X_FIELDCAT
TYPE SLIS_FIELDCAT_ALV.
Data: I_FIELDCAT1
TYPE SLIS_T_FIELDCAT_ALV.
Data: X_FIELDCAT1
TYPE SLIS_FIELDCAT_ALV.
i_variant
I_variant1
like disvariant,
like disvariant.
like mseg-mblnr ,
Matnr
like mseg-matnr,
like mseg-charg,
like mseg-lgort,
like mseg-dmbtr,
ebeln
like mseg-ebeln,
icn(4)
type c ,
sym(4) type c ,
excpt(2) type c ,
box(1),
END OF I_TAB.
*EJECT
Data: begin of i_doc occurs 0.
INCLUDE STRUCTURE MSEG.
Data: end of i_doc.
CHANGING
cs_variant
= internal table containing the program name (and the default variant---optional)
EXCEPTIONS
not_found = 2.
The user can also choose from the list of existing variants using the function module 'REUSE_ALV_VARIANT_F4'. Example:
Initialization.
v_repid = sy-repid.
* Display default variant
PERFORM SUB_VARIANT_INIT.
AT SELECTION-SCREEN ON P_VAR.
* Once the user has entered variant, check about its existence
PERFORM SUB_CHECK_PVAR.
AT SELECTION-SCREEN ON VALUE-REQUEST FOR P_VAR.
* Display a list of various variants of the report when the User presses F4 key in the variant field
PERFORM SUB_VARIANT_F4.
*&---------------------------------------------------------------------*
*&
Form SUB_VARIANT_INIT
*&---------------------------------------------------------------------*
* Display default variant
*&---------------------------------------------------------------------*
Form SUB_VARIANT_INIT.
I_VARIANT1-REPORT = SY-REPID.
* Search default variant for the report
CALL FUNCTION 'REUSE_ALV_VARIANT_DEFAULT_GET'
EXPORTING
i_save
= 'A'
CHANGING
cs_variant = i_variant1
EXCEPTIONS
not_found = 2.
* If default variant is found, use it as default.
* Else, use the variant LAYOUT1.
IF sy-subrc = 0.
p_var = i_variant1-variant.
ELSE.
p_var = 'LAYOUT1'.
ENDIF.
endform.
"SUB_VARIANT_INIT
*&---------------------------------------------------------------------------------*
*&
Form SUB_CHECK_PVAR
*&---------------------------------------------------------------------------------*
* Once the user has entered variant, check about its existence
*&---------------------------------------------------------------------------------*
FORM SUB_CHECK_PVAR.
* If the name of the variable is not blank, check about its existence
if not p_var is initial.
clear i_variant.
i_variant-report = sy-repid.
i_variant-variant = p_var.
CALL FUNCTION 'REUSE_ALV_VARIANT_EXISTENCE'
EXPORTING
I_SAVE
= 'A'
CHANGING
CS_VARIANT = I_VARIANT.
* If no such variant found, flash error message
If sy-subrc ne 0 .
Message e398(00) with 'No such variant exists'.
Else.
* If variant exists, use the variant name to populate structure
* I_VARIANT1 which will be used for export parameter: IS_VARIANT
* in the function module : REUSE_ALV_GRID_DISPLAY
Clear i_variant1.
Move p_var to i_variant1-variant.
Move sy-repid to i_variant1-report.
endif.
Else.
Clear i_variant.
endif.
ENDFORM.
"SUB_CHECK_PVAR
*&---------------------------------------------------------------------------------*
*&
Form SUB_VARIANT_F4
*&---------------------------------------------------------------------------------*
* Display a list of various variants of the report when the User presses F4 key in the variant field
*&---------------------------------------------------------------------------------*
Form SUB_VARIANT_F4.
i_variant-report = sy-repid.
* Utilizing the name of the report, this function module will search for a list of
* variants and will fetch the selected one into the parameter field for variants
CALL FUNCTION 'REUSE_ALV_VARIANT_F4'
EXPORTING
IS_VARIANT
= I_VARIANT
I_SAVE
= 'A'
I_DISPLAY_VIA_GRID = 'X'
IMPORTING
ES_VARIANT
= I_VARIANT1
EXCEPTIONS
NOT_FOUND
=1
PROGRAM_ERROR
=2
OTHERS
= 3.
IF SY-SUBRC = 0.
P_VAR = I_VARIANT1-VARIANT.
ENDIF.
endform.
"SUB_VARIANT_F4
The internal table to be output has the same structure as a Data Dictionary structure which is referred to in the internal
table declaration using LIKE or INCLUDE STRUCTURE. In this case the attributes of the different fields is taken directly from
the table and the attributes (key fields, length, texts etc) need to state explicitly.
2.
3.
The structure name is passed to ALV in the parameter I_STRUCTURE_NAME of the function module
REUSE_ALV_LIST_DISPLAY.
All the values entered in the catalog are specific to the particular field whose name is entered in the fieldname FIELDNAME
of the fieldcat structure. The name of the table is also entered in the corr. Fieldname TABNAME of the structure.
Row_pos (row position): Only relevant if the list output is to be multi-line (two or three lines) by default. So, this
Col_pos (column position): This parameter is relevant when the fields in the output are to be different from the
field in the list output. The column order can be changed interactively by the user. If this parameter is initial for all field catalog
entries, columns appear in the internal table field sequence.
Value set: 0, 1 - 60
-
Fieldname (field name): This is the name of the internal table field for which the parameters are passed in the
catalog.
Value set: internal output table field name (required parameter)
-
Tabname (internal output table): Name of the internal output table that contains the field FIELDCAT-FIELDNAME
above.
Value set: SPACE, internal output table name.
-
Ref_fieldname (reference field name): Name of the Data Dictionary field referred to. This parameter is only used
when the internal output table field described by the current field catalog entry has a reference to the Data Dictionary (not a
program field), and the field name in the internal output table is different from the name of the field in the Data Dictionary. If
the field names are identical, naming the Data Dictionary structure or table in the FIELDCAT-REF_TABNAME parameter is
sufficient.
Value set: SPACE, Data Dictionary field name.
-
Ref_tabname (reference table/structure field name): Structure or table name of the referred Data Dictionary field.
This parameter is only used when the internal output table field described by the current field catalog entry has a Data
Dictionary reference (not a program field).
Value set: SPACE, name of a Data Dictionary structure or table
Cfieldname (currency unit field name): This is used for currency fields that have a reference to any unit field. This is
only relevant for amount columns with associated unit. This parameter contains the Name of the internal output table field
containing the currency unit associated with the amount field FIELDCAT-FIELDNAME. The field in FIELDCAT-CFIELDNAME
must have its own field catalog entry.
Value set: SPACE, output table field name.
-
Ctabname (internal currency unit field output table): Name of the internal output table containing the FIELDCAT-
CFIELDNAME field.
Value set: SPACE, output table field name.
Link to measurement unit
-
Qfieldname (measurement unit field name): Only relevant for quantity columns with unit link. Name of the internal
output table field containing the measurement unit associated with the quantity field FIELDCAT-FIELDNAME. The field in
FIELDCAT-QFIELDNAME must have its own field catalog entry.
Value set: SPACE, output table field name.
-
Qtabname (internal measurement unit field output table): Name of the internal output table containing the FIELDCAT-
QFIELDNAME field.
Value set: SPACE, output table field name.
-
Outputlen (column width): This parameter is used if the desired output length for a field is desired to be different from
the internal output table field. For fields with a Data Dictionary link this parameter can be left initial. For fields without a Data
Dictionary link (program field) the parameter must be given the value of the desired field list output length (column width).
Initial = column width is the output length of the referred Data Dictionary field (domain).
N = column width is n characters.
Key (key column): By default, the system makes some fields in the output as key fields, provided the fields are key
fields in their referencing table. Using this parameter, fields other than key fields of the referencing table can be made key
field. This parameter is most important if the output needs to contain some field, which are not scrollable or cannot be hidden.
If the internal output table contains fields that are key fields from different tables, then all those fields in the report output
becomes un-scrollable and cannot be hidden. So, the fields in the output internal table should not be referenced from tables
in which they are key fields. Instead, they should be referenced to the tables in which they are not key fields, incase they are
not desired as key field in the output.
'X' = key field (key field output in color) and Key fields cannot be interactively hidden. Parameter FIELDCAT-NO_OUT must be
left initial.
Value set: SPACE, 'X'.
-
Key_sel (hide-able key column): This parameter is only relevant for the fields which are made key fields using
FIELDCAT-KEY = 'X'. Using this parameter the Key field can be hidden interactively.
The key column sequence cannot be changed interactively by the user. The output is controlled by the FIELDCAT-NO_OUT
parameter analogously to non-key fields.
Value set: SPACE, 'X'.
-
No_out (field in field list): This parameter is used to remove certain fields from the output during initial display. The
user can however interactively choose the field for output from the field list in the display variant.
'X' = field is not displayed in the current list.
Value set: SPACE, 'X'.
-
Tech (technical field): This parameter is used to make certain field display only in the field catalog. The fields with this
parameter set cannot be output in the list nor can they be displayed interactively from the catalog.
'X' = technical field.
Value set: SPACE, 'X'.
-
Emphasize (highlight columns in color): As name suggests, this field parameter is used to highlight certain field with
chosen colors.
Value set: SPACE, 'X' or 'Cxyz' (x:'1'-'9'; y,z: '0'=off ,'1'=on).
'X' = column is colored with the default column highlight color.
'Cxyz' = column is colored with a coded color:
- C: Color (coding must begin with C)
- X: color number
- Y: bold
- Z: inverse
-
Hotspot (column as hotspot): This parameter is used to make certain field appear as hotspot i.e. a hand is displayed
if the cursor is positioned on the field value. Single click on such fields cause the PICK OR F2 events to happen.
Value set: SPACE, 'X'.
'X' = column cells are output as hotspots.
-
Fix_column (fix column): This parameter is used to fix certain columns in the output. All columns to be fixed must
have this flag, starting from the left. If a column without this flag is output, only the columns to the left of this column are fixed.
The user can change the column fixing interactively.
Value set: SPACE, 'X'.
'X' = column fixed (does not scroll horizontally).
-
Do_sum (sum over column): the user can also call this function interactively.
Value set: SPACE, 'X'.
No_sum (sums forbidden): No sum can be calculated over this field, although the data type of the field would allow
summing.
Value set: SPACE, 'X'.
-
Icon: The parameter displays certain column contents as icons. The internal output table column contents must be
Symbol: The internal output table column must be a valid symbol character.
Just (justification): This parameter is used for alignment of the contents of the output table. This is only relevant for
CHAR or NUMC fields in the output internal table. The justification of the column header always follows the justification of the
columns. Independent justification of the column header is not possible.
Value set: SPACE, 'R', 'L', and 'C'.
' ' = Default justification for this data type
'R' = right-justified output
'L' = left-justified output
'C' = centered output.
-
Lzero (leading zeros): By default ALV outputs NUMC fields right-justified without leading zeros. Using this parameter
No_sign (no +/- sign): This parameter is used to suppress the signs of the output fields. It is only relevant for the
value fields.
Value set: SPACE, 'X'.
'X' = value output without +/ sign.
-
Edit_mask (field formatting): To apply the report output formatting options same as in the WRITE statement in report
writing.
Value set: SPACE, template.
The following parameters are used for customizing the texts in the heading of the output of the columns. The texts are taken
from the Data Dictionary for fields with a Data Dictionary reference. If this is not desired, the text parameters can also be
specified. The Data Dictionary texts are then ignored.
If the user changes the column width interactively, the column header text with the appropriate length is always used.
The interactive function 'Optimize column width' takes account of both the field contents and the column headers: if all field
contents are shorter than the shortest column header, the column width depends on the column header.
The 'long field label' is also used in display variant definition,
Sort, etc. Popup.
-
Ddictxt (specify text): You can specify with values 'L', 'M', and 'S', the keyword that should always be used as column
header. If the column width changes, no attempt is made in this case to find an appropriate header for the new output width.
Value set: SPACE, 'L', 'M', and 'S'.
Sample code:
*&---------------------------------------------------------------------*
*&
Form SUB_PREPARE_FIELDCATALOG
*&---------------------------------------------------------------------*
* Prepare field catalog for the main report. State the name of the field, name of internal table, various formatting options etc
*----------------------------------------------------------------------*
Form SUB_PREPARE_FIELDCATALOG.
X_FIELDCAT-COL_POS = 1.
X_FIELDCAT-FIELDNAME
= 'SYM'.
X_FIELDCAT-TABNAME
= 'I_TAB'.
X_FIELDCAT-SELTEXT_M
= 'Stat'.
X_FIELDCAT-SYMBOL = 'X'.
X_FIELDCAT-FIELDNAME
= 'MATNR'.
X_FIELDCAT-TABNAME
= 'I_TAB'.
X_FIELDCAT-SELTEXT_M
= 'MatItem'.
* It is going to be the key field.The color for this field is going to be different
X_FIELDCAT-KEY
X_FIELDCAT-KEY_SEL
= 'X'.
= 'X'.
* Single click on the field will trigger double click event. Also, a hand will appear when the cursor navigates to the field
X_FIELDCAT-HOTSPOT = 'X'.
X_FIELDCAT-FIX_COLUMN
= 'X'.
X_FIELDCAT-REF_TABNAME
= 'MSEG'.
= 'MAKTG'.
X_FIELDCAT-TABNAME
= 'I_TAB'.
X_FIELDCAT-SELTEXT_M
= 'Description'.
* X_FIELDCAT-OUTPUTLEN
= 50.
X_FIELDCAT-HOTSPOT = space.
X_FIELDCAT-JUST
= 'C'.
X_FIELDCAT-KEY
= 'X'.
X_FIELDCAT-FIX_COLUMN
*X_fieldcat-no_out
X_FIELDCAT-FIX_COLUMN
* The field is centre(C for centre, R and L for left and right) justified
= 'X'.
= 'X'.
= 'X'.
= 'CHARG'.
X_FIELDCAT-TABNAME
= 'I_TAB'.
X_FIELDCAT-SELTEXT_M
= 'Batch'.
* X_FIELDCAT-OUTPUTLEN
= 10.
X_FIELDCAT-HOTSPOT = space.
APPEND X_FIELDCAT TO I_FIELDCAT.
CLEAR X_FIELDCAT.
X_FIELDCAT-COL_POS = 5.
X_FIELDCAT-FIELDNAME
= 'EBELN'.
X_FIELDCAT-TABNAME
= 'I_TAB'.
X_FIELDCAT-SELTEXT_M
= 'Purchase Order'.
* X_FIELDCAT-OUTPUTLEN
= 14.
X_FIELDCAT-EMPHASIZE
= 'C511'.
X_FIELDCAT-NO_OUT
= 'X'.
= 'MBLNR'.
X_FIELDCAT-TABNAME
= 'I_TAB'.
X_FIELDCAT-SELTEXT_M
= 'Document no'.
* X_FIELDCAT-OUTPUTLEN
= 14.
X_FIELDCAT_EMPHASIZE
= 'C711'.
X_FIELDCAT-NO_OUT
= 'X'.
= 'WERKS'.
X_FIELDCAT-TABNAME
= 'I_TAB'.
X_FIELDCAT-SELTEXT_M
= 'Plant'.
* X_FIELDCAT-OUTPUTLEN
= 5.
X_FIELDCAT-EMPHASIZE
= 'C310'.
= 'LGORT'.
X_FIELDCAT-TABNAME
= 'I_TAB'.
X_FIELDCAT-SELTEXT_M
= 'St.Loc'.
* X_FIELDCAT-OUTPUTLEN
= 7.
* X_FIELDCAT-NO_OUT
= 'X'.
= 'MENGE'.
X_FIELDCAT-TABNAME
= 'I_TAB'.
X_FIELDCAT-SELTEXT_M
= 'Quantity'.
X_FIELDCAT-OUTPUTLEN
X_FIELDCAT-DO_SUM
X_FIELDCAT-REF_TABNAME
= 12.
= 'X'.
= 'MSEG'.
= 'ICN'.
X_FIELDCAT-TABNAME
= 'I_TAB'.
X_FIELDCAT-SELTEXT_M
= ''.
X_FIELDCAT-OUTPUTLEN
X_FIELDCAT-ICON
* X_FIELDCAT-NO_OUT
= 2.
= 'X'.
= 'X'.
= 'MEINS'.
X_FIELDCAT-TABNAME
= 'I_TAB'.
X_FIELDCAT-SELTEXT_M
= 'Unit'.
X_FIELDCAT-OUTPUTLEN
X_FIELDCAT-FIELDNAME
= 5.
= 'MEINS'.
= 'DMBTR'.
X_FIELDCAT-TABNAME
= 'I_TAB'.
X_FIELDCAT-SELTEXT_M
= 'Local curr'.
X_FIELDCAT-OUTPUTLEN
X_FIELDCAT-INTTYPE
X_FIELDCAT-JUST
X_FIELDCAT-DO_SUM
= 12.
= 'P'.
= 'R'.
= 'X'.
= 'EXCPT'.
X_FIELDCAT-TABNAME
= 'I_TAB'.
X_FIELDCAT-SELTEXT_M
= ''.
X_FIELDCAT-OUTPUTLEN
= 3.
"SUB_PREPARE_FIELDCATALOG
Only relevant for hierarchical-sequential lists using the layout parameter IS_LAYOUT-EXPAND_FIELDNAME of the structure
IS_LAYOUT. Exit for passing item entries (ITEM table) for a header record that was expanded interactively by the user.2.
Slis_ev_reprep_sel_modify TYPE slis_formname VALUE 'REPREP_SEL_MODIFY'.
RS_SELFIELD-TABINDEX contains the header table index for which the item entries are to
output table (T_OUTTAB_SLAVE). The Callback is only called if ALV has no items for a header that is to be expanded.
RFLG_ALL is passed with 'X' if the user shows all items. The application must ensure that
item table.
RS_SELFIELD is initial in this case.
3.
'CALLER_EXIT'.
Is called at the beginning of the function module to make special settings. It is not usually used.
4.
I_CALLBACK_USER_COMMAND.
The selection information and list status are output together (if they exist) on a separate page by default
7.
Slis_ev_foreign_top_of_page TYPE
'FOREIGN_END_OF_PAGE'.
The event end-of-page is always processed in ALV and only passed to the caller via callback. This is still the case, e.g. when
the caller processes a details list which was not formatted by ALV (e.g. a popup with further information about selected list
records which were displayed by ALV).In this case, end-of-page cannot be formatted by ALV analogously to the basic list, it
must be handled completely by the caller. The event end-of-page still occurs in ALV. When ALV notices an end-of-page that
was not caused by an ALV output, the form routine in FOREIGN_END_OF_PAGE is called.
10.
If a user list status is to be set, it must be done in the form routine assigned to this event. The ALV function codes, which
must not be active, are in the Parameter RT_EXTAB. This table must be passed with the SET PF-STATUS command (with
inactive user function codes as well, if necessary).
The STANDARD status of the function group SALV should be used as a template for a user-specific status. As this is a
frequently used Callback event, its form routine can also be passed directly in the interface in the IMPORTING parameter
I_CALLBACK_PF_STATUS_SET.11.
'TOP_OF_LIST'.
Information output at the start of the list*
13.
Information output at the end of a page. This is only called for printing.14.
VALUE 'END_OF_LIST'.
Information output at the end of the list
15.
Output information after each output line. Should only be used in justified cases because it costs a lot of performance.
16.
Output information before each output line. Should only be used in justified cases because it costs a lot of performance.
17.
This event table (I_EVENTS) is now checked with the desired constants. If the desired constant is found, then the
corresponding field for the FORM NAME is populated with the name of the routine containing the corresponding
event. Sample code :
FORMNAME_TOP_OF_PAGE TYPE SLIS_FORMNAME VALUE 'TOP_OF_PAGE',
FORMNAME_END_OF_PAGE TYPE SLIS_FORMNAME VALUE 'END_OF_PAGE', FORMNAME_USER_COMMAND TYPE
SLIS_FORMNAME VALUE 'USER_COMMAND'.
DATA: L_I_EVENT TYPE SLIS_ALV_EVENT.
CALL FUNCTION 'REUSE_ALV_EVENTS_GET'
EXPORTING
I_LIST_TYPE = 0
IMPORTING
ET_EVENTS = I_EVENTS.
READ TABLE I_EVENTS WITH KEY NAME = SLIS_EV_TOP_OF_PAGE INTO L_I_EVENT.
IF SY-SUBRC = 0.
MOVE FORMNAME_TOP_OF_PAGE TO L_I_EVENT-FORM.
APPEND L_I_EVENT TO I_EVENTS.
ENDIF.
READ TABLE I_EVENTS WITH KEY NAME = SLIS_EV_END_OF_PAGE INTO L_I_EVENT.
IF SY-SUBRC = 0.
MOVE FORMNAME_END_OF_PAGE TO L_I_EVENT-FORM.
APPEND L_I_EVENT TO I_EVENTS.
ENDIF.
CLEAR L_I_EVENT.
READ TABLE I_EVENTS WITH KEY NAME = SLIS_EV_USER_COMMAND INTO L_I_EVENT.
IF SY-SUBRC = 0.
MOVE FORMNAME_USER_COMMAND TO L_I_EVENT-FORM.
APPEND L_I_EVENT TO I_EVENTS.
ENDIF.
This will prepare the events table for the report.
The report will contain three forms for the above events:
1.
FORM TOP_OF_PAGE: This form will contain the top of page event for the report i.e. header etc
Using the function module 'REUSE_ALV_COMMENTARY_WRITE', the internal table containing the headings for top of page
event can be passed to the list output. Also, any logo specific to the report can be passed to the function module.
2.
FORM END_OF_PAGE: This form will contain the end of page event for the report i.e. footer etc
3.
FORM USER_COMMAND: This form will contain the desired user command i.e. pick/line selection
Display options
Exceptions
Totals
Interaction
Detail screen
Color
Other
The layout table is of type slis_layout_alv_spec and has the following fields:
Display options
1. Colwidth_optimize (1) TYPE c: This parameter optimizes the length of the different columns in the output. The width of
the different col. now depends on the max. Length of the data in the column.
Value set: SPACE, 'X'
'X' = optimizes the column width so that all contents are displayed completely.
2. No_colhead (1) TYPE c: This parameter suppresses the column headings
Value set: SPACE, 'X'.
'X' = column headers are not output
3*. No_hotspot*(1) TYPE c : The headings of the report output are not output as hotspot.
Value set: SPACE, 'X'.
'X' = column headers are not output as hotspot
4*. Zebra*(1) TYPE c : The report is output in the striped pattern.
Value set: SPACE, 'X'.
'X' = striped pattern (e.g. for wide lists)
5. No_vline (1) TYPE c: The report output contains columns only separated by space and no lines. It is not relevant for:
hierarchical-sequential lists and multiple-line lists.
Value set: SPACE, 'X'.
'X' = columns separated by SPACE
6. No_min_linesize(1) TYPE c : The report line size is equal to the width of the list. It is not relevant for block lists.
Value set: SPACE, 'X'.
'X' = line size depends on list width
' ' = Line size is set to 80 or MIN_LINESIZE (if > 0) .
7. Min_linesize LIKE sy-linsz: The report output contains a minimum possible length of line. If initial min_linesize is set to 80
by default, then this parameter is used to customize it. The prerequisite for this is that the parameter no_min_linesize should
be ' '.
Value set: 0, 10 - 250
If the list is wider, the format uses the list width (maximum 250 or MAX_LINESIZE (if > 0)).
8. Max_linesize LIKE sy-linsz: The default max. Linesize is 250. To change this default value, this parameter can
interactively-define the maximum list width setting.
Value set: 0, 80 - 1020
9. Window_titlebar LIKE rsmpe-tittext: To set the titlebar on the report output.
10. No_uline_hs(1) TYPE c.
Exceptions
11. Lights_fieldname TYPE slis_fieldname: Internal output table field containing the codes of exceptions to be output.
Output table field code: '1' = red traffic light
'2' = yellow traffic light
'3' = green traffic light Fieldname for exception
Value set: SPACE, internal output table field name.
12. Lights_tabname TYPE slis_tabname: Name of the internal output table that contains the field in the parameter
LIGHTS_FIELDNAME. If LIGHTS_FIELDNAME is not empty, this field must also be filled for hierarchical-sequential lists.
Only relevant for hierarchical-sequential lists.
Value set: SPACE, internal output table name.
13. Lights_rollname LIKE dfies-rollname: The documentation of this data element is displayed when you call F1 help for an
exception column.
Value set: SPACE, data element name.
14. Lights_condense (1) TYPE c : If a list record is output with 'red traffic light', each Subtotal that includes this record is
also output with 'red traffic light'.
Value set: SPACE, 'X'
'X' = the 'maximum' exception of the items in the subtotal is output at subtotal level.
Sums
15*. No_sumchoice* (1) TYPE c: This parameter allows the choice for summing up Only by field catalog.
Value set: SPACE, 'X'
'X' = fields which are to be summed, passed by the calling program (FIELDCAT-DO_SUM = 'X'). The user should not be able
to change this value interactively.
16. No_totalline(1) TYPE c : Removes the option of having totals after sub-totals.
Value set: SPACE, 'X'
'X' = no total record is to be output. Subtotals can still be calculated and output. The fields in the subtotals are flagged
DO_SUM = 'X' in the field list.
17. No_subchoice(1) TYPE c : Does not allow the user to interactively change the field chosen for subtotals.
Value set: SPACE, 'X'
'X' = value whose change triggers subtotals, provided by the calling program. The user should not be able to change this
value interactively.
18. No_subtotals(1) TYPE c : No subtotals possible
Value set: SPACE, 'X'
'X' = no subtotals.
19*. Numc_sum*(1) TYPE c : Totals only possible for NUMC-Fields.
20. No_unit_splitting TYPE c: No separate total lines by inh.units
21.totals_before_items TYPE c: Display totals before the items
22. Totals_only(1) TYPE c : Show only totals
Value set: SPACE, 'X'
'X' = only total records are output.
23. Totals_text(60) TYPE c : Text for 1st col. in totals
Value set: SPACE, string (max.60)
' ' = The first column in the total record contains an appropriate number of '*'s to indicate the total by default. If the first column
is wide enough, the string 'Total' is output after the asterisks.
'String' = The string passed is output after the total indicated by '*', if the column is wide enough.
24. Subtotals_text(60) TYPE c : Texts for subtotals
Value set: SPACE, string (max.60)
' ' = In the first column of subtotal records, the subtotal is indicated by an appropriate number of '*' by default. If the first
column is not a subtotal criterion, the string 'Total' is output after the asterisks, if the column is wide enough.
'String' = the string passed is output after the subtotal indicated by '*', if the column is wide enough and the first column is not
a subtotal criterion. If it is a subtotal criterion, its value is repeated after the total, if the column is wide enough.
Interaction
25. Box_fieldname TYPE slis_fieldname: Fieldname for checkbox in the report output. If the list has checkboxes at the start
of records (for selecting several records), this parameter contains the internal output table field name indicated by the
checkbox selection column. The field is a checkbox at the start of list records without a list header.
Value set: SPACE, internal output table field name
26. Box_tabname TYPE slis_tabname: Name of the internal output table that contains the field in the parameter
BOX_FIELDNAME. If BOX_FIELDNAME is not empty, this field must also be filled for hierarchical-sequential lists.
Value set: SPACE, internal output table name.
27. Box_rollname LIKE dd03p-rollname: rollname for checkbox
28. Expand_fieldname TYPE slis_fieldname: fieldname flag 'expand'. The user can show or hide the items by clicking on
the folder symbol (hotspot). If the items for a header entry are only to be read by the calling program and passed to ALV
when a header has been expanded interactively, this can be controlled via the CALLBACK event
'ITEM_DATA_EXPAND'.
29. Hotspot_fieldname TYPE slis_fieldname: Used to make the fieldname flag hotspot.
30. No_input(1) TYPE c : The fields are only display fields.
Value set: SPACE, 'X'
'X' = all ready-for-input fields in a list are displayed as not ready-for-input. (Record selection checkboxes and fields which can
be made ready-for-input via the field list parameter FIELDCAT-INPUT = 'X')
31. F2code LIKE sy-ucomm: To assign an ALV standard function code to double-click (F2), assign the function code to this
parameter. Ex.: to assign the ALV standard function 'Detail' ('&ETA') to F2.
=> LAYOUT-F2CODE = '&ETA'.
Value set: SPACE, function code
32. Confirmation_prompt: confirm. Prompt when leaving
Value set: SPACE, 'X'
'X' = if one of the functions 'Back (F03)', 'Exit (F15)' or 'Cancel (F12)' occurs, a confirmation prompt appears.
33. Key_hotspot(1) TYPE c : The key fields are displayed as hotspot. The columns defined in the field catalog as key fields
(FIELDCAT-KEY = 'X') are output as hotspots, i.e. clicking on a key column (highlighted in color in the list) calls the function
under F2.
Value set: SPACE, 'X'.
34. Reprep(1) TYPE c : report report interface active.
35. Group_buttons (1) TYPE c : group-buttons for COL1 - COL5 . Group output fields via FIELDCAT-SP_GROUP in the
field list, and pass the group name to the list module in the interface parameter IT_SPECIAL_GROUPS.
Value set: SPACE, 'X'.
36. No_keyfix(1) TYPE c : Used to make the key fields scrollable.
Value set: SPACE, 'X'.
' ' = The key columns defined in the field catalog by FIELDCAT-KEY = 'X' are fixed in the list output. These columns do not
scroll horizontally. The item table key columns are fixed in hierarchical-sequential lists. The header table key fields are not
considered here.
'X' = key columns not fixed
37. Get_selinfos(1) TYPE c : To read selection screen.
Value set: SPACE, 'X'.
If the calling program is a report with an ABAP/4 selection screen, setting this parameter makes ALV read the selection
screen again. If the selections are read successfully, a pushbutton, via which the user can call a popup which lists the report
selections in a simple form, becomes active on the results list output by ALV.
38. group_change_edit(1) TYPE c : Settings by user for new group
Value set: SPACE, 'X'
'X' = the user can enter a format option for each sort criterion in the sort/subtotal popup, for the list format when this value
changes (e.g. new page or underline).
39. No_scrolling(1) TYPE c : Does not allow scrolling of the list to the right.
Value set: SPACE, 'X'.
40. Expand_all(1) TYPE c : Expand all positions
Detailed screen
40. Detail_popup(1) TYPE c : show detail in popup.
Value set: SPACE, 'X'
' ' = List record detail display in full-screen mode, with top-of-page.
'X' = list record detail display in popup (without top-of-page).
41. Detail_initial_lines(1) TYPE c : show also initial lines
Value set: SPACE, 'X'
' ' = Only fields whose contents are not initial are output in the detail view.
'X' = initial field contents are also output in detail.
41. detail_titlebar(30) type c : Titlebar for detail screen
Value set: SPACE, string (max.30)
' ' = ' Detail: Display' is output as the title of the detail window.
'String' = the string passed is output as the title of the detail window.
Display variants
42. Header_text (20) TYPE c: Text for header button. Only relevant for hierarchical-sequential lists. You can toggle between
display field and field list views via pushbuttons in the display variant definition popup for hierarchical-sequential lists. The
views refer to the hierarchy level of the fields. This is technically a toggle between the header table and item table fields.
Value set: SPACE, CHAR (20)
' ' = The header table field pushbutton text is 'Header' by default.
CHAR (20) = header table field pushbutton text.
43.item_text(20) TYPE c : Text for item button. Only relevant for hierarchical-sequential lists. You can toggle the view
between the display fields and the field list via pushbuttons in the display variant definition popup for hierarchical-sequential
lists. The views refer to the hierarchy level of the fields. This is technically a toggle between the header table and item table
fields.
Value set: SPACE, CHAR (20)
' ' = The pushbutton text for the item table fields is 'Item' by default.
CHAR (20) = item table field pushbutton text.
44.default_ item(1) TYPE c : Items as default. Only relevant for hierarchical-sequential lists.
Value set: SPACE, 'X'
' ' = The header table fields are displayed by default in the display variant definition popup. The user can switch to the item
table fields interactively.
'X' = the item table fields are displayed by default in the display variant Definition Popup.
= ws_fcode.
= 'X'.
I_LAYOUT-colwidth_optimize = 'X'.
I_LAYOUT-no_keyfix = 'X'.
I_LAYOUT-get_selinfos = 'X'.
I_LAYOUT-no_hotspot = 'X'.
I_LAYOUT-no_input = 'X'.
I_LAYOUT-hotspot_fieldname = FIELDNAME.
I_LAYOUT-no_input
= 'X'.
I_LAYOUT-no_vline
= `X'.
I_LAYOUT-no_colhead
= ' '.
I_LAYOUT-lights_condense = ` `.
I_LAYOUT-totals_text
I_LAYOUT-subtotals_text
I_LAYOUT-totals_only
= ` `.
= ` `.
= ` `.
I_LAYOUT-key_hotspot
= 'X'.
I_LAYOUT-detail_popup
= 'X'.
I_LAYOUT-group_change_edit = 'X'.
I_LAYOUT-GROUP_BUTTONS
= 'X'.
Are output in the pop up. Selection info, which the list tool read in the selection screen (when called by a report with a
selection screen), is replaced by the values passed.
'S' = the selection info which the list tool read in the selection screen of the calling report are modified by the entries in the
table IS_SEL_HIDE-T_ENTRIES.
v
t_entries:
t_entries-mode: 'A' = output the selection info for the current table record in the info popup.
'D' = do not output select option or SELNAME parameter selection info in the popup.
t_entries-selname: (only used in t_entries-mode = 'D') : Name of the select option or parameter. The following table
fields are only used in t_entries-mode = 'A'. They contain the selection information to be added.
-
t_entries-field: DDIC field name of the field for which selection information is to be output.
If t_entries-field and t_entries-table have been entered, this text is taken from DDIC.
tabname : Only relevant for hierarchical-sequential lists. Name of the internal output table.
group : '* ' = new page at group value change ,'UL' = underline at group value change
REUSE_ALV_LIST_DISPLAY
The first function module is used to pass the field catalog to the report output and merge it with the internal output table.
FUNCTION reuse_alv_fieldcatalog_merge.
*"--------------------------------------------------------------------*"*"Lokale Schnittstelle:
*" IMPORTING
*"
VALUE(I_PROGRAM_NAME)
*"
VALUE(I_INTERNAL_TABNAME)
*"
VALUE(I_STRUCTURE_NAME)
*"
VALUE(I_CLIENT_NEVER_DISPLAY)
*"
VALUE(I_INCLNAME)
*" CHANGING
*"
*" EXCEPTIONS
*"
INCONSISTENT_INTERFACE
*"
PROGRAM_ERROR
*"--------------------------------------------------------------------Import parameters
I_PROGRAM_NAME: Program in which the internal output table is declared and populated
I_INTERNAL_TABNAME: Internal output table name
I_STRUCTURE_NAME: Structure name (structure, table, and view)
I_CLIENT_NEVER_DISPL: Hide client fields default 'X'
I_INCLNAME: Data declarations include name CHANGING parameter
CT_FIELDCAT: Field catalog with field descriptions
The variant based on a program-internal table should only be used for rapid prototyping since the following restrictions
apply:
1. Performance is affected since the code of the table definition must always be read and interpreted at
runtime.
2. Dictionary reference are only considered if the keywords LIKE or INCLUDE STRUCTURE (not TYPE) are used.
Step 8(Display Internal Output Table)
The other function module is used to display the internal output table with the contents
FUNCTION reuse_alv_list_display.
*"---------------------------------------------------------------------*"*"Lokale Schnittstelle:
" IMPORTING
*"
*"
*"
*"
*"
*"
*"
*"
*"
*"
*"
*"
*"
*"
*"
*"
*"
*"
*"
*"
VALUE(I_SCREEN_START_COLUMN) DEFAULT 0
*"
VALUE(I_SCREEN_START_LINE) DEFAULT 0
*"
VALUE(I_SCREEN_END_COLUMN) DEFAULT 0
*"
VALUE(I_SCREEN_END_LINE) DEFAULT 0
"
EXPORTING
*"
VALUE(E_EXIT_CAUSED_BY_CALLER)
*"
"
*"
"
*"
TABLES
T_OUTTAB
EXCEPTIONS
PROGRAM_ERROR Import parameters
I_INTERFACE_CHECK:
I_CALLBACK_PROGRAM:
IT_FIELDCAT:
IT_EXCLUDING:
IT_SPECIAL_GROUPS:
IT_SORT:
IT_FILTER:
IS_SEL_HIDE:
I_DEFAULT:
I_SAVE:
IS_VARIANT:
IT_EVENTS:
IT_EVENT_EXIT:
IS_PRINT:
IS_REPREP_ID:
I_SCREEN_START_COLUMN:
I_SCREEN_START_LINE:
I_SCREEN_END_COLUMN:
I_SCREEN_END_LINE:
IT_EVENT_EXIT:
IS_PRINT:
IS_REPREP_ID:
I_SCREEN_START_COLUMN:
Print information
Initialization keys for Re/Re interface
Coordinates for list in dialog box
I_SCREEN_START_LINE:
I_SCREEN_END_COLUMN:
I_SCREEN_END_LINE:
E_EXIT_CAUSED_BY_CALLER:
ES_EXIT_CAUSED_BY_USER:
T_OUTTAB:
Export parameters
Notes
v
All interactions performed on the list refer directly to the internal output table. Sorting the list, for example, also involves a
resorting of the internal output table passed (since it was passed by reference).
v
An important factor determining the usability of the tool or of various generic functions (totals, subtotals) is the expected
I_INTERFACE_CHECK
I_BYPASSING_BUFFER
I_BUFFER_ACTIVE
I_CALLBACK_PROGRAM
I_CALLBACK_PF_STATUS_SET
I_CALLBACK_USER_COMMAND
I_CALLBACK_TOP_OF_PAGE
I_CALLBACK_HTML_TOP_OF_PAGE
I_CALLBACK_HTML_END_OF_LIST
I_STRUCTURE_NAME
I_BACKGROUND_ID
I_GRID_TITLE
I_GRID_SETTINGS
IS_LAYOUT
IT_FIELDCAT
IT_EXCLUDING
IT_SPECIAL_GROUPS
IT_SORT
IT_FILTER
IS_SEL_HIDE
I_DEFAULT
I_SAVE
IS_VARIANT
IT_EVENTS
IT_EVENT_EXIT
IS_PRINT
IS_REPREP_ID
I_SCREEN_START_COLUMN
I_SCREEN_START_LINE
I_SCREEN_END_COLUMN
I_SCREEN_END_LINE
IT_ALV_GRAPHICS
IT_ADD_FIELDCAT
IT_HYPERLINK
E_EXIT_CAUSED_BY_CALLER
ES_EXIT_CAUSED_BY_USER
Application functions can be added to excluding table rt_extab if they are to be disabled.
The routine is called whenever the standard user interface would be set with SET PF-STATUS.
Default
If no EXIT routine is specified, the ALV sets a status that corresponds to status STANDARD of function group SALV.
tabname :
tabindex :
fieldname:
Field name
endsum :
sumindex :
value
refresh :
exit
setup
formatting the header information and also ensures online HTML formatting. In the print preview or in batch mode, the text
passed is then output in the normal format.
If module REUSE_ALV_COMMENTARY_WRITE cannot be used, you must use two parameters instead. In
I_CALLBACK_TOP_OF_PAGE you pass the form routine that is responsible for normal formatting in batch mode or in the
print preview mode. The form routine that is responsible for online formatting, is passed in parameter
I_CALLBACK_HTML_TOP_OF_PAGE. If one of these parameters is not filled, top-of-page is not output in the respective
mode.
I_CALLBACK_HTML_TOP_OF_PAGE
EXIT routine for HTML TOP-OF-PAGE
Description
If function module REUSE_ALV_COMMENTARY_WRITE is not used in the form for CALLBACK_TOP_OF_PAGE, the
form routine must be passed in parameter
I_CALLBACK_HTML_TOP_OF_PAGE for the online mode. The form should then
have the following format:
form top_of_page using cl_dd type ref to cl_dd_document.
In the form, you can, for example, use methods of class CL_DD_DOCUMENT
to display text in HTML format. I_CALLBACK_HTML_END_OF_LIST
EXIT routine for HTML END-OF-LIST
Description
In this parameter, you can pass a form for the online handling of end-of-list. The form must have the followiong format:
I_GRID_SETTINGS you can reduce the default size to 0%. To do this, you use two fields:
COLL_TOP_P: Sets Top-of-Page to 0%
COLL_END_L: Sets End-of-List to 0% IS_LAYOUT
List layout specifications
Description
Structure for describing the list to be output.
The parameters are described and grouped based on the following
categories:
Display options
Exceptions
Totals
Interaction
Detail screen
Color
Other
Note the section on pre-defined settings.
colwidth_optimize
Display options
X' = Optimizes the column width to ensure that the content is displayed completely.
Exceptions
lights_fieldname
Value range: SPACE, field name of the internal output table field of the internal output table that contains the coding of the
exceptions to be output .
Coding in the field of the output table:
'1' = red traffic light
'2' = yellow traffic light
'3' = green traffic light lights_tabname
Value range: SPACE, table name of the internal output table Table name of the internal output table that contains the
specified field in parameter LIGHTS_FIELDNAME. lights_rollname
Value range: SPACE, data element name
The documentation defined for this data element is displayed when the F1 help for an exception column is
called. lights_condense
no_sumchoice
Value range: SPACE, 'X'
'X' = Value fields for which totals are calculated are communicated by the calling program (FIELDCAT-DO_SUM = 'X').
The user should not be allowed to change this pre-defined setting interactively.
no_totalline
Value range: SPACE, 'X'
'X' = No overall totals line should be displayed. If required, subtotals can nevertheless be calculated and displayed. The
fields which are used for calculating subtotals are to be marked with
DO_SUM = 'X' in the field catalog.-
no_subchoice
no_subtotals
Value range: SPACE, 'X'
'X' = Calculating subtotals should not be allowed.
totals_only
Value range: SPACE, 'X'
'X' = Data is output in compressed format only at totals line level.
Prerequisite: IMPORTING parameter IT_SORT is filled accordingly with the sort criteria and the subtotals indicator.
See also the documentation on IMPORTING parameter IT_SORT.
-
totals_text
Value range: SPACE, string (not more than 60)
' ' = In the first column, the standard system indicates the totals level by displaying an adequate number of '*' for the
overall total.After the asterisks, the system displays the string 'total' provided
that the column width of the first output column is large enough. If the column width is not sufficient, only the asterisks
are displayed.
'string' = After the totals level indicated visually by means of '*', the system displays the string passed provided that the
column width is sufficient.
subtotals_text
Value range: SPACE, string (not more than 60) ' ' = In the first column, the standard system indicates the totals level by
displaying an adequate number of '*' for the subtotals line. After the asterisks, the system displays the string *total* provided
that the column width of the first output column is large enough and the characteristic of the first column is not a subtotal
criterion. If the column width is not sufficient, only the asterisks are displayed.
'string' = After the totals level indicated visually by means of '*', the system displays the string passed provided that the
column width is sufficient and the characteristic of the first column is not a subtotal criterion.
If the characteristic is a subtotal criterion, the system repeats the characteristic value for which subtotals were calculated
after the totals level provided that the column width is sufficient.
numc_sum
Value range: SPACE, 'X'
' ' = In the standard system, it is not possible to calculate totals
'X' = It is generally possible to calculate totals for NUMC fields. If this indicator is set, you can use parameter FIELDCATNO_SUM to control for each NUMC column whether totals can be calculated or not. Interaction
-
box_fieldname
Value range: SPACE, field name of the internal output table. If the list should have checkboxes at the beginning of each list
row (to allow the user to select multiple rows at once), you must fill this parameter with the field name of the internal output
table that represents the selection column for selecting rows with the help of checkboxes. The field is always displayed as a
checkbox at the beginning of each list row without a list heading.
box_tabname
Value range: SPACE, table name of the internal output table
f2code
Value range: SPACE, function code
Meaning when the ALV standard interface is used:
If you want to assign a standard ALV function code to a double-click (F2), you must assign this function code to this
parameter.
Example: You want to assign the standard ALV function 'Detail'
('&ETA') to F2.
=> LAYOUT-F2CODE = '&ETA'
Meaning if a self-defined interface is used: Case 1:
You leave the standard ALV function code for F2 '&IC1' in the copied interface of the application. However, you want to have
a function executed with F2 that is not assigned to F2 in the interface
(standard ALV function or application function). You must
F2CODE. Case 2:
You remove the standard ALV function code for F2 '&IC1' from the interface of the application and use another function
code instead (standard ALV function or application function). You must
communicate this function code to the ALV using parameter F2CODE.
This is required if you want to allow columns to be selected.
confirmation_prompt
key_hotspot
Value range: SPACE, 'X'
The columns defined as key fields in the field catalog (FIELDCAT-KEY = 'X') are output as a hotspot. This means that
single-clicking a key field (highlighted in color in the list) triggers the function assigned to F2.
reprep
Value range: SPACE, 'X'
'X' = Enable report/report interface
Prerequisite: Application system (=> report RKKBRSTI exists).
The list module acts as a potential sender in the report/report interface (interface initialization, if required).
The calling report/module pool entered in I_CALLBACK_PROGRAM is declared to the report/report interface as the sender
report with type RT=Report. If the sender report is assigned to receiver reports in table TRSTI, function code BEBx is set to
active. ( x = function code class)
Example:
If sender RKTFGS15 has a receiver assignment for Report Writer report group 7KOI with function code class '3' (SAP
setting), this receiver report group is called through the report/report interface
at function code 'BEB3'. The selections passed to the report/report interface are the report selections and the key
information of the selected row.
For more information on the report/report interface, see the documentation on function group 'RSTI'.Detail screen
detail_initial_lines
Value range: SPACE, 'X'
' ' = In the detail view, the system displays only fields whose content is not set to initial.
'X' = Initial field contents are also displayed on the detail screen.
detail_titlebar
Value range: SPACE, string (not more than 30)
' ' = The system displays 'Detail: Display' as the title of the detail screen.
'string' = The system displays the string passed as the title of the detail screen.
Color
info_fieldname
Value range: SPACE, field name of the internal output table.
You can color an entire list row individually by using a color code that is set for each row in a column of the internal output
table. You must assign the field name of the field with the color code to
this parameter.
The field of the internal output table must be of type CHAR(3).
The code must comply with the following syntax:
'Cxy':
coltab_fieldname
Value range: SPACE, field name of the internal output table
You can color cells individually by using a color code that is set for the row of the cells in a column of the internal output
table. You must assign the field name of the field with the color code to this parameter.
The field of the internal output table must be of type SLIS_T_SPECIALCOL_ALV.
Principle: The field for the color code is filled in the row in which the cells to be colored are located. The field then contains
an internal table of the above structure that includes the field names of the cells to be colored with the color code. The cell
coordinates are therefore derived from the row position in which the color code is written and the column information
contained in the color table. The row structure of the internal color table of type SLIS_T_SPECIALCOL_ALV is as follows:
Farbtabelle-NAME
Description
Field catalog containing the field descriptions of the fields to be considered for the list output (usually, this is a subset of
the fields in the internal output table).
Basically, you need a field catalog for each list output that uses the ALV.
The field catalog associated with the output table is generated in the code of the caller. You can generate the field catalog
automatically or semi-automatically by calling function module
REUSE_ALV_FIELDCATALOG_MERGE.
See also the documentation on function module : REUSE_ALV_FIELDCATALOG_MERGE.
The minimum values required for the field catalog are documented in the 'Default' section. The caller can optionally use all
other parameters to assign non-standard output attributes to a field.
It is only in the following cases that you are not required to generate the field catalog and pass it explicitly:
The structure of the internal table to be output corresponds to a structure stored in the Data Dictionary and is
referenced with LIKE or INCLUDE STRUCTURE in the declaration of the internal table.
Positioning
catalog.
The parameter determines the relative column position of the field in the list output. The column sequence can
interactively be changed by the user. If this parameter is set to its initial value for each field catalog entry, the columns are
arranged in the order of the fields in the field catalog.
Identification
-
catalog has a reference to the Data Dictionary (that is, is not a program field) and if the field name in the internal output table
is not identical to the field name of the field in the Data Dictionary. If both field names are identical, it is sufficient to specify
the Data Dictionary structure or table in parameter FIELDCAT-REF_TABNAME.
-
Value range: SPACE, name of a structure or table in the Data Dictionary Structure or table name of the referenced field in the
Data Dictionary.
This parameter is only required if the field in the internal output table that is described by the current entry in the field catalog
has a reference to the Data Dictionary (that is, is not a program field).
Reference to fields with currency units/units of measure
Each amount or quantity field of the internal output table whose decimal places are to be displayed with the proper unit in the
list output, must comply with the following conventions:
- The field is of data type QUAN or CURR (internal type P).
(Physically, the field must actually belong to this data type.
Overriding the physical data type with parameter FIELDCAT-DATATYPE has no effect.)
- There is one field in the internal output table that contains the relevant unit.
- There is also an entry for the unit field in the field catalog.
(If the unit should not be displayed as a column in the list and the user should not be able to show the unit
interactively, for example, because the unit is always unique and therefore explicitly output by the caller in the list header, then
you can assign parameter FIELDCAT-TECH = 'X' to the field catalog entry for the unit field.
If a value field has a reference to a unit, this has the following effects when the list is output:
- The decimal places are displayed with the proper unit.
- An initial value field with reference to a non-initial unit is displayed as '0' (provided that FIELDCAT-NO_ZERO is
initial). If unit-specific totals are calculated for this value field, the unit is considered in the analysis of whether homogeneous
units exist.
- An initial value field with reference to an initial unit is displayed as SPACE. If unit-specific totals are calculated for this
value field, the unit SPACE has no effect on the homogeneity of the unit if the value field is initial.
- For non-initial value fields with initial unit, the unit SPACE is considered as a unit when unit-specific totals are
calculated.
Reference to the currency unit
of the field in the internal output table that contains the currency unit for the amount field FIELDCAT-FIELDNAME.
There must be a separate field catalog entry for the field specified in FIELDCAT-CFIELDNAME.
Reference to the unit of measure
-
Field name of the field in the internal output table that contains the unit of measure for the amount field FIELDCATFIELDNAME.
There must be a separate field catalog entry for the field specified in FIELDCAT-QFIELDNAME.
Output options for a column
-
icon (icon)
Value range: SPACE, 'X'
'X' = The column contents are displayed as an icon.
The column contents of the internal output table must consist of valid icon strings (
(xx)).
symbol (symbol)
Value range: SPACE, 'X'
'X' = The column contents are output as a symbol.
The column contents of the internal output table must consist of valid symbol characters.
The caller should consider the problem of printing symbols.
Although symbols can generally be printed, they are not always shown correctly depending on the printer configuration.
-
just (justification)
Value range: SPACE, 'R', 'L', 'C'
Only relevant to fields of data type CHAR or NUMC
' ' = Default justification according to data type
'R' = Right-justified output
'L' = Left-justified output
'C' = Centered output
The justification of the column header depends on the justification of the column contents. You cannot justify the column
Texts
The following parameters for texts are always required for program fields without reference to the Data Dictionary.
For fields with reference to the Data Dictionary, the texts are retrieved from the Data Dictionary. If you do not want this,
you can fill the text parameters also for fields with reference to the Data Dictionary. If you do this, the corresponding texts
from the Data Dictionary will be ignored.
If the user changes the column width interactively, the text with the appropriate length is always used as the column
header.
If the user optimizes the column width interactively, both the field contents and the column headings are considered for
the list output:
If all field contents are shorter than the shortest column heading, the column width is set based on the column heading.
The long field label is also used in the dialog boxes for defining the display variant, the sort order, and so on.
-
reptext_ddic (heading)
header. If the column width is changed, the system tries to find a heading that fits the new output width.
Parameter for program fields without reference to the Data Dictionary
See also the parameter in the 'Texts' section.
-
conversion exit.
Prerequisites:
- FIELDCAT-EDIT_MASK = '==conv'
See also the documentation on parameter FIELDCAT-EDIT_MASK
- FIELDCAT-INTLEN = n
See documentation on parameter FIELDCAT-INTLEN
n = Field output length of the external display
The column width FIELDCAT-OUTPUTLEN must not be equivalent to the output length of the external display
(FIELDCAT-DDIC_OUTPUTLEN).
o intlen (internal output length)
Value range: 0 (initial), n
Only relevant to fields without reference to the Data Dictionary whose output should nevertheless be modified using a
conversion exit.
Prerequisites:
- FIELDCAT-EDIT_MASK = '==conv'
See also the documentation on parameter FIELDCAT-EDIT_MASK
- FIELDCAT-DDIC_OUTPUTLEN = n
See also the documentation on parameter FIELDCAT-DDIC_OUTPUTLEN
n = Field output length of the internal display
o rollname (data element)
Value range: SPACE, name of a data element from the Data Dictionary
You can use this parameter to provide an F1 help for a program field without reference to the Data Dictionary or to
provide an F1 help other than that of the Data Dictionary for a field with reference to the Data Dictionary.
When the F1 help is called for this field, the documentation for the data element assigned is displayed.
If, for fields with reference to the Data Dictionary,
FIELDCAT-ROLLNAME is initial, the documentation for the data element of the referenced field in the Data Dictionary is
displayed.
Other
o sp_group (field group key)
Value range: SPACE, CHAR(1)
Key for grouping fields
You assign the key to the group description using parameter
IT_SPECIAL_GROUPS (see also the documentation on parameter IT_SPECIAL_GROUPS).
If you define such an assignment in the field catalog using
IT_SPECIAL_GROUPS, the fields in the field list of the display variant dialog box are grouped accordingly.
o reprep (selection criterion of the report/report interface)
Value range: SPACE, 'X'
Prerequisites:
- The report/report interface exists in the system.
(function group RSTI, table TRSTI)
- Parameter LAYOUT-REPREP = 'X'
(See also the documentation on parameter
LAYOUT-REPREP of IMPORTING parameter IS_LAYOUT)
'X' = If the report/report interface is called, the value of this field is passed as a selection criterion in the selected branch
line of the interface.
Default
o For internal table fields with reference to a field defined in the
Data Dictionary, it is normally sufficient to make the following specifications:
- fieldname
- ref_tabname
Note:
All fields not explicitly mentioned here are either not relevant in this context or are not released!
All other information is retrieved by the ALV from the Data Dictionary.
If you do not specify the relative column position (COL_POS), the fields are output in the list in the order in which they
were added to the field catalog.
REF_FIELDNAME must only be specified if the field name of the internal table field is not identical to the field name of the
referenced field in the Data Dictionary.
Priority rule:
Specifications made in the field catalog take priority over specifications in the Data Dictionary.
For internal table fields without reference to the Data Dictionary (program fields), it is normally sufficient to make the
following specifications:
- fieldname
- outputlen
- datatype (without data type, character is the default)
- seltext_s
- seltext_l
Note:
If you assign a data element to parameter ROLLNAME, you can, for example, implement an F1 help for program fields.
IT_EXCLUDING
IS_SEL_HIDE
Selection information modification
Description
This parameter is currently not supported!
Only relevant if layout parameter LAYOUT-GET_SELINFOS of IMPORTING structure IS_LAYOUT is set.
Complex type for modifying information displayed on the selection dialog box:
o mode:
'R' = Only entries passed in internal table IS_SEL_HIDE-T_ENTRIES are output on the dialog box.
Selection information obtained by the list tool by reading the selection screen again (only if the report is called with selection
screen) are replaced by the entries passed.
'S' = The selection information obtained by the list tool by reading the selection screen of the calling report
again, are modified by the entries of table IS_SEL_HIDE-T_ENTRIES.
o t_entries:
o t_entries-mode: 'A' = Display selection information of the current table row on the information dialog box.
'D' = Do not display selection information of the Select option or of parameter SELNAME on the dialog box.
o t_entries-selname: (required only if t_entries-mode = 'D') name of Select option or parameter
The following table fields are only required if t_entries-mode = 'A'.
They contain the selection information to be added.
o t_entries-field: DDIC field name of the field for which selection information is to be displayed
I_DEFAULT
Initial variant active/inactive logic
Description
Initial variant maintenance active/inactive. .
Prerequisite:
SPACE
I_SAVE
Variants can be saved
Description
Controls the save mode
Prerequisite:
Parameter IS_VARIANT is filled accordingly.
See also the documentation on IMPORTING parameter IS_VARIANT.
Value Range
o ' ' = Display variants cannot be saved
Defined display variants (such as delivered display variants) can be selected for presentation regardless of this
indicator. However, changes cannot be saved.
o 'X' = Standard save mode
Display variants can be saved as standard display variants.
Saving display variants as user-specific is not possible.
o 'U' = User-specific save mode
Display variants can only be saved as user-specific.
o 'A' = Standard and user-specific save mode
Display variants can be saved both as user-specific and as standard variants. Users make their choice on the dialog
box for saving the display variant.
Default : SPACE .
IS_VARIANT
Variant information
Description
This structure is only relevant if display variants are to be saved and/or read.
Variant information including the name of the list variant that is used to output the list.
To allow display variants to be read within the ALV, you must specify the access path using fields REPORT (required
field), HANDLE (optional field) and/or LOG_GROUP (optional field).
If you also want to allow display variants to be saved, you must additionally fill parameter I_SAVE accordingly.
Example Code
WS_REPNAME = SY-REPID.
CALL FUNCTION 'REUSE_ALV_FIELDCATALOG_MERGE'
EXPORTING
I_PROGRAM_NAME
= WS_REPNAME
= WS_REPNAME
CHANGING
CT_FIELDCAT
= I_FIELDTAB.
IF SY-SUBRC <> 0.
WRITE: 'SY-SUBRC: ', SY-SUBRC, 'REUSE_ALV_FIELDCATALOG_MERGE'.
ENDIF.
CALL FUNCTION 'REUSE_ALV_LIST_DISPLAY'
EXPORTING
I_CALLBACK_PROGRAM = WS_REPNAME
I_STRUCTURE_NAME
IS_LAYOUT
= I_LAYOUT
IT_FIELDCAT
= I_FIELDTAB
I_DEFAULT
= 'A'
I_SAVE
= 'A'
IS_VARIANT
= 'X'
IT_EVENTS
= I_EVENTS[]
IT_SORT
= I_SORT
IS_SEL_HIDE
= I_SELINFO
TABLES
T_OUTTAB
IF SY-SUBRC <> 0.
WRITE: 'SY-SUBRC: ', SY-SUBRC, 'REUSE_ALV_LIST_DISPLAY'.
ENDIF
Using other function module 'REUSE_ALV_GRID_DISPLAY' can help us get list output in the form of a grid and also attach
logos to the report output.
Sample code
1 Simple list output:
REPORT Y_DEMO_ALV NO STANDARD PAGE HEADING.
* Data to be displayed
DATA: I_SFLIGHT TYPE TABLE OF SFLIGHT.
*---------------------------------------------------------------------*
* Selection
SELECT * FROM SFLIGHT INTO TABLE I_SFLIGHT.
* Call ABAP List Viewer (ALV)
CALL FUNCTION 'REUSE_ALV_LIST_DISPLAY'
EXPORTING
I_STRUCTURE_NAME = 'SFLIGHT'
TABLES
T_OUTTAB
= I_SFLIGHT.
= I_SFLIGHT.
= p_title
i_selection
= 'X'
i_zebra
= 'X'
I_SCREEN_START_COLUMN
I_SCREEN_START_LINE
I_SCREEN_END_COLUMN
I_SCREEN_END_LINE
=0
=0
=0
=0
i_checkbox_fieldname
*
*
= 'W_CHK'
I_LINEMARK_FIELDNAME
I_SCROLL_TO_SEL_LINE
= 'X'
i_tabname
= 'I_OUTTAB'
i_structure_name
= 'SFLIGHT'
IT_FIELDCAT
IT_EXCLUDING
I_CALLBACK_PROGRAM
I_CALLBACK_USER_COMMAND =
IS_PRIVATE
=
=
= I_PRIVATE
IMPORTING
es_selfield
e_exit
= i_selfield
= w_exit
TABLES
t_outtab
= i_outtab
EXCEPTIONS
program_error
OTHERS
=1
= 2.
IF sy-subrc <> 0.
*
*****the internal table is modified with a cross sign for marking the rows selected
LOOP AT i_outtab WHERE w_chk = 'X'.
WRITE: / i_outtab-carrid, i_outtab-price.
ENDLOOP.
TYPE SLIS_LAYOUT_ALV.
Form SUB_VARIANT_INIT
*&---------------------------------------------------------------------*
* Display default variant
*----------------------------------------------------------------------*
form SUB_VARIANT_INIT.
I_VARIANT1-REPORT = SY-REPID.
* Search default variant for the report
CALL FUNCTION 'REUSE_ALV_VARIANT_DEFAULT_GET'
EXPORTING
i_save
= 'A'
CHANGING
cs_variant = i_variant1
EXCEPTIONS
not_found = 2.
* If default variant is found , use it as default.
* Else , use the variant LAYOUT1.
IF sy-subrc = 0.
p_var = i_variant1-variant.
ELSE.
p_var = 'LAYOUT1'.
ENDIF.
endform.
" SUB_VARIANT_INIT
*&---------------------------------------------------------------------*
*&
Form SUB_CHECK_PVAR
*&---------------------------------------------------------------------*
* Once the user has entered variant, check about its existence
*----------------------------------------------------------------------*
FORM SUB_CHECK_PVAR.
* If the name of the variable is not blank, check about its existence
if not p_var is initial.
clear i_variant.
i_variant-report = sy-repid.
i_variant-variant = p_var.
CALL FUNCTION 'REUSE_ALV_VARIANT_EXISTENCE'
EXPORTING
I_SAVE
= 'A'
CHANGING
CS_VARIANT = I_VARIANT.
* If no such variant found , flash error message
if sy-subrc ne 0 .
message e398(00) with 'No such variant exists'.
else.
* If variant exists , use the variant name to populate structure
* I_VARIANT1 which will be used for export parameter : IS_VARIANT
* in the function module : REUSE_ALV_GRID_DISPLAY
clear i_variant1.
move p_var to i_variant1-variant.
move sy-repid to i_variant1-report.
endif.
else.
clear i_variant.
endif.
ENDFORM.
" SUB_CHECK_PVAR
*&---------------------------------------------------------------------*
*&
Form SUB_PREPARE_FIELDCATALOG
*&---------------------------------------------------------------------*
* Prepare field catalog for the main report. State the name of
* the field , name of internal table , various formatting options etc
*----------------------------------------------------------------------*
form SUB_PREPARE_FIELDCATALOG.
* First field to appear in ALV list
X_FIELDCAT-COL_POS = 1.
* Name of the internal table field
X_FIELDCAT-FIELDNAME = 'SYM'.
* Name of the internal table
X_FIELDCAT-TABNAME = 'I_TAB'.
* Heading for the field
X_FIELDCAT-SELTEXT_M = 'Stat'.
* The field is going to contain a symbol
x_fieldcat-symbol = 'X'.
* Append the specifications to the internal table for field catalog.
append X_fieldcat TO I_FIELDCAT.
clear x_fieldcat.
* Second field to appear in ALV list
X_FIELDCAT-COL_POS = 2.
* Name of the field in the internal table
X_FIELDCAT-FIELDNAME = 'MATNR'.
* Name of the internal table
X_FIELDCAT-TABNAME = 'I_TAB'.
* Heading for the column
X_FIELDCAT-SELTEXT_M = 'MatItem'.
* It is going to be the key field.The color for this field is going to
* be different
X_fieldcat-key = 'X'.
X_fieldcat-key_sel = 'X'.
* Single click on the field will trigger double click event.Also, a hand
* will appear when the cursor navigates to the field
X_fieldcat-hotspot = 'X'.
* The column and those left to it will not scroll
X_fieldcat-fix_column = 'X'.
* F1 help will come as it is referenced to DDIC table
x_fieldcat-ref_tabname = 'MSEG'.
append X_fieldcat TO I_FIELDCAT.
clear x_fieldcat.
X_FIELDCAT-COL_POS = 3.
X_FIELDCAT-FIELDNAME = 'MAKTG'.
X_FIELDCAT-TABNAME = 'I_TAB'.
X_FIELDCAT-SELTEXT_M = 'Description'.
* X_FIELDCAT-OUTPUTLEN = 50.
x_fieldcat-hotspot = space.
* The field is centre(C for centre, R and L for left and
* right) justified
x_fieldcat-just = 'C'.
x_fieldcat-key = 'X'.
x_fieldcat-fix_column = 'X'.
* X_fieldcat-no_out = 'X'.
X_fieldcat-fix_column = 'X'.
append X_fieldcat TO I_FIELDCAT.
clear x_fieldcat.
X_FIELDCAT-COL_POS = 4.
X_FIELDCAT-FIELDNAME = 'CHARG'.
X_FIELDCAT-TABNAME = 'I_TAB'.
X_FIELDCAT-SELTEXT_M = 'Batch'.
* X_FIELDCAT-OUTPUTLEN = 10.
x_fieldcat-hotspot = space.
append X_fieldcat TO I_FIELDCAT.
clear x_fieldcat.
X_FIELDCAT-COL_POS = 5.
X_FIELDCAT-FIELDNAME = 'EBELN'.
X_FIELDCAT-TABNAME = 'I_TAB'.
X_FIELDCAT-SELTEXT_M = 'Purchase Order'.
* X_FIELDCAT-OUTPUTLEN = 14.
* The field will be colored differently(Cxyz)
x_fieldcat-emphasize = 'C511'.
* Initially the field will be hidden
x_fieldcat-no_out = 'X'.
append X_fieldcat TO I_FIELDCAT.
clear x_fieldcat.
X_FIELDCAT-COL_POS = 6.
X_FIELDCAT-FIELDNAME = 'MBLNR'.
X_FIELDCAT-TABNAME = 'I_TAB'.
X_FIELDCAT-SELTEXT_M = 'Document no'.
* X_FIELDCAT-OUTPUTLEN = 14.
x_fieldcat-emphasize = 'C711'.
x_fieldcat-no_out = 'X'.
append X_fieldcat TO I_FIELDCAT.
clear x_fieldcat.
X_FIELDCAT-COL_POS = 7.
X_FIELDCAT-FIELDNAME = 'WERKS'.
X_FIELDCAT-TABNAME = 'I_TAB'.
X_FIELDCAT-SELTEXT_M = 'Plant'.
* X_FIELDCAT-OUTPUTLEN = 5.
x_fieldcat-emphasize = 'C310'.
append X_fieldcat TO I_FIELDCAT.
clear x_fieldcat.
X_FIELDCAT-COL_POS = 8.
X_FIELDCAT-FIELDNAME = 'LGORT'.
X_FIELDCAT-TABNAME = 'I_TAB'.
X_FIELDCAT-SELTEXT_M = 'St.Loc'.
* X_FIELDCAT-OUTPUTLEN = 7.
* X_fieldcat-no_out = 'X'.
append X_fieldcat TO I_FIELDCAT.
clear x_fieldcat.
X_FIELDCAT-COL_POS = 9.
X_FIELDCAT-FIELDNAME = 'MENGE'.
X_FIELDCAT-TABNAME = 'I_TAB'.
X_FIELDCAT-SELTEXT_M = 'Quantity'.
X_FIELDCAT-OUTPUTLEN = 12.
* Summation is allowed for this field
x_fieldcat-do_sum = 'X'.
X_FIELDCAT-ref_tabname = 'MSEG'.
append X_fieldcat TO I_FIELDCAT.
clear x_fieldcat.
X_FIELDCAT-COL_POS = 10.
X_FIELDCAT-FIELDNAME = 'ICN'.
X_FIELDCAT-TABNAME = 'I_TAB'.
X_FIELDCAT-SELTEXT_M = ''.
X_FIELDCAT-OUTPUTLEN = 2.
x_fieldcat-icon = 'X'.
* X_fieldcat-no_out = 'X'.
append X_fieldcat TO I_FIELDCAT.
clear x_fieldcat.
X_FIELDCAT-COL_POS = 11.
X_FIELDCAT-FIELDNAME = 'MEINS'.
X_FIELDCAT-TABNAME = 'I_TAB'.
X_FIELDCAT-SELTEXT_M = 'Unit'.
X_FIELDCAT-OUTPUTLEN = 5.
x_fieldcat-qfieldname = 'MEINS'.
append X_fieldcat TO I_FIELDCAT.
clear x_fieldcat.
X_FIELDCAT-COL_POS = 12.
X_FIELDCAT-FIELDNAME = 'DMBTR'.
X_FIELDCAT-TABNAME = 'I_TAB'.
X_FIELDCAT-SELTEXT_M = 'Local curr'.
X_FIELDCAT-OUTPUTLEN = 12.
x_fieldcat-INTTYPE = 'P'.
x_fieldcat-just = 'R'.
x_fieldcat-do_sum = 'X'.
append X_fieldcat TO I_FIELDCAT.
clear x_fieldcat.
X_FIELDCAT-COL_POS = 13.
X_FIELDCAT-FIELDNAME = 'EXCPT'.
X_FIELDCAT-TABNAME = 'I_TAB'.
X_FIELDCAT-SELTEXT_M = ''.
X_FIELDCAT-OUTPUTLEN = 3.
append X_fieldcat TO I_FIELDCAT.
clear x_fieldcat.
endform.
" SUB_PREPARE_FIELDCATALOG
*&---------------------------------------------------------------------*
*&
Form SUB_SELECT_RECORD
*&---------------------------------------------------------------------*
* Fetches records from database into table i_tab to be passed as export
* parameter t_outtab in function module : REUSE_ALV_GRID_DISPLAY
*----------------------------------------------------------------------*
form SUB_SELECT_RECORD.
SELECT mblnr A~matnr A~maktg charg
werks lgort menge meins dmbtr ebeln
FROM makt as a join mseg as b
on ( a~matnr = b~matnr )
INTO TABLE I_TAB
where b~bwart = '101' .
endform.
" SUB_SELECT_RECORD
*&---------------------------------------------------------------------*
*&
Form SUB_MODIFY_RECORDS
*&---------------------------------------------------------------------*
* Populate stat and icon columns of internal table i_tab with specific
* columns and symbols based on some logic for quantity and value fields.
*----------------------------------------------------------------------*
form SUB_MODIFY_RECORDS.
loop at i_tab.
if i_tab-dmbtr gt 10000.
* Field icn of internal table is going to contain icon . For this column
*icon_allowed is set in the field catalog table. For various icons,see
* type pool <ICON>
i_tab-icn = '
(1V)'.
" SUB_MODIFY_RECORDS
*&---------------------------------------------------------------------*
*&
Form SUB_DETERMINE_ALV_LAYOUT
*&---------------------------------------------------------------------*
*& Defines the overall structure of the report layout
*----------------------------------------------------------------------*
form SUB_DETERMINE_ALV_LAYOUT.
* Field EXCPT will show the light signal
STRUCT_LAYOUT-LIGHTS_FIELDNAME
= 'EXCPT'.
* Field BOS of the internal table will act as pushbutton and will appear
* at the left of the grid display. User will press that to select a
* record
struct_layout-box_fieldname
= 'BOX'.
STRUCT_layout-totals_text
= 'Totqty '.
STRUCT_LAYOUT-ZEBRA
= 'X'.
struct_layout-confirmation_prompt
struct_layout-detail_titlebar
struct_layout-no_sumchoice
struct_layout-totals_only
endform.
= 'X'.
= 'Details of Storing'.
= 'X'.
= 'X'.
" SUB_DETERMINE_ALV_LAYOUT
*&---------------------------------------------------------------------*
*&
Form SUB_DETERMINE_SORT_SEQUENCE
*&---------------------------------------------------------------------*
* Defines the sort sequence of the report
*----------------------------------------------------------------------*
form SUB_DETERMINE_SORT_SEQUENCE.
X_sort-spos = 1.
X_sort-fieldname = 'MATNR'.
X_sort-tabname = 'I_TAB'.
X_sort-up = 'X'.
X_sort-subtot = 'X'.
" SUB_DETERMINE_SORT_SEQUENCE
*&---------------------------------------------------------------------*
*&
Form SUB_SHOW_ALV_LIST
*&---------------------------------------------------------------------*
* Shows ALV list in grid form
*----------------------------------------------------------------------*
form SUB_SHOW_ALV_LIST.
CALL FUNCTION 'REUSE_ALV_GRID_DISPLAY'
EXPORTING
I_CALLBACK_PROGRAM
I_GRID_TITLE
= V_REPID
= 'Details of Storing'
"* title
I_callback_pf_status_set
= 'PF_STATUS_SET'
i_callback_user_command
= 'USER_COMMAND'
IS_LAYOUT
= STRUCT_LAYOUT
IT_FIELDCAT
= I_FIELDCAT
IT_SORT
= IT_SORT
I_DEFAULT
= 'X'
I_SAVE
= 'A'
IS_VARIANT
= i_variant1
= i_events[]
TABLES
* Passes data table for ALV display
T_OUTTAB
= I_TAB
EXCEPTIONS
PROGRAM_ERROR
OTHERS
=1
= 2.
IF SY-SUBRC <> 0.
* MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
*
endform.
" SUB_SHOW_ALV_LIST
*&---------------------------------------------------------------------*
*&
Form set_status
*&---------------------------------------------------------------------*
* Form used to set the Custom pf-status of the List Display
*----------------------------------------------------------------------*
* rt_extab :
*----------------------------------------------------------------------*
FORM pf_status_set USING i_rt_extab TYPE slis_t_extab.
data : x_extab type slis_extab.
x_extab-fcode = '&LFO'.
append x_extab to i_rt_extab.
* Pf-status STANDARD of program SAPLSALV is copied to ZSTANDARD of the
* current program and the pushbutton for Information (okcode=&LFO) is
* excluded
SET PF-STATUS 'ZSTANDARD' excluding i_rt_extab .
ENDFORM.
*&---------------------------------------------------------------------*
*&
Form user_command
*&---------------------------------------------------------------------*
* Form used to handle USER_COMMAND events
*----------------------------------------------------------------------*
* rf_ucomm: Function Code
* rs
*----------------------------------------------------------------------*
FORM user_command USING rf_ucomm LIKE sy-ucomm
rs TYPE slis_selfield.
data : v_mblnr like mseg-mblnr.
case rf_ucomm.
* A custom pushbutton for record deletion is set in the GUI status. When a record is selected , the field BOC for that *record
becomes 'X'.
* The records are traced and deleted and the fields are refreshed( rs of type slis_selfield is refreshed)
when '&DEL'.
Form SUB_HOTSPOT
*&---------------------------------------------------------------------*
*
text
*----------------------------------------------------------------------*
* --> p1
text
* <-- p2
text
*----------------------------------------------------------------------*
form SUB_HOTSPOT.
message i398(00) with 'Hello'.
endform.
" SUB_HOTSPOT
*&---------------------------------------------------------------------*
*&
Form SUB_VARIANT_F4
*&---------------------------------------------------------------------*
* Display a list of various variants of the report when the user presses F4 key in the variant field
*------------------------------------------------------------------------*
form SUB_VARIANT_F4.
i_variant-report = sy-repid.
* Utilising the name of the report , this function module will search for a list of variants and will fetch the selected one * into
the parameter field for variants
CALL FUNCTION 'REUSE_ALV_VARIANT_F4'
EXPORTING
IS_VARIANT
I_SAVE
= I_VARIANT
= 'A'
I_DISPLAY_VIA_GRID = 'X'
IMPORTING
ES_VARIANT
= I_VARIANT1
EXCEPTIONS
NOT_FOUND
=1
PROGRAM_ERROR
OTHERS
=2
= 3.
IF SY-SUBRC = 0.
P_VAR = I_VARIANT1-VARIANT.
ENDIF.
ENDFORM.
" SUB_VARIANT_F4
*&---------------------------------------------------------------------*
*&
Form SUB_SELECT_DOCUMENT
*&---------------------------------------------------------------------*
form SUB_SELECT_DOCUMENT.
data : v_lines type i .
read table i_tab with key box = 'X'.
Select * from mseg INTO TABLE I_DOC WHERE MBLNR = I_TAB-MBLNR.
IF SY-SUBRC EQ 0 .
CALL FUNCTION 'REUSE_ALV_FIELDCATALOG_MERGE'
EXPORTING
I_PROGRAM_NAME
I_INTERNAL_TABNAME
I_STRUCTURE_NAME
= V_REPID
= 'I_DOC'
= 'MSEG'
CHANGING
CT_FIELDCAT
= I_FIELDCAT1
EXCEPTIONS
INCONSISTENT_INTERFACE
PROGRAM_ERROR
OTHERS
=1
=2
= 3.
IF SY-SUBRC <> 0.
MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
ENDIF.
clear struct_layout1.
STRUCT_layout1-colwidth_optimize = 'X'.
refresh it_sort.
clear it_sort.
= V_REPID
I_GRID_TITLE
= 'Details of Document'
IS_LAYOUT
= STRUCT_LAYOUT1
IT_FIELDCAT
= I_FIELDCAT1
i_structure_name
I_DEFAULT
= 'MSEG'
= 'X'
I_SAVE
= 'A'
TABLES
T_OUTTAB
= I_DOC
EXCEPTIONS
PROGRAM_ERROR
OTHERS
=1
=2
.
IF SY-SUBRC <> 0.
MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
ENDIF.
ENDIF.
endform.
" SUB_SELECT_DOCUMENT
*&---------------------------------------------------------------------*
*&
Form SUB_COMMENT_BUILD
*&---------------------------------------------------------------------*
form SUB_COMMENT_BUILD using I_top_of_page TYPE slis_t_listheader.
DATA: ls_line TYPE slis_listheader.
***Header
CLEAR ls_line.
ls_line-typ = 'H'.
* LS_LINE-KEY: not used for this type
ls_line-info = 'Heading list'.
APPEND ls_line TO I_top_of_page.
***Selection
CLEAR ls_line.
ls_line-typ = 'S'.
ls_line-key = 'Key 1'.
ls_line-info = 'Material '.
APPEND ls_line TO i_top_of_page.
ls_line-key = 'Key 2'.
ls_line-info = 'Document no'.
APPEND ls_line TO I_top_of_page.
***Action
CLEAR ls_line.
endform.
" SUB_COMMENT_BUILD
*&---------------------------------------------------------------------*
*&
Form SUB_EVENTTAB_BUILD
*&---------------------------------------------------------------------*
* Defines the event table
*&---------------------------------------------------------------------*
FORM sub_eventtab_build USING l_events TYPE slis_t_event.
DATA: ls_event TYPE slis_alv_event.
* Get the different events of the ALV
CALL FUNCTION 'REUSE_ALV_EVENTS_GET'
EXPORTING
i_list_type = 0
IMPORTING
et_events = l_events.
* Search the top of page events
READ TABLE l_events WITH KEY name = slis_ev_top_of_page INTO ls_event.
IF sy-subrc = 0.
MOVE 'TOP_OF_PAGE' TO ls_event-form.
APPEND ls_event TO l_events.
ENDIF.
endform.
" SUB_EVENTTAB_BUILD
*&---------------------------------------------------------------------*
*
FORM TOP_OF_PAGE
*&---------------------------------------------------------------------*
* When TOP-OF-PAGE will be fired , this event will be called and it
* will use the contents of i_list_top_of_page for output in the header
*&---------------------------------------------------------------------*
FORM top_of_page.
CALL FUNCTION 'REUSE_ALV_COMMENTARY_WRITE'
EXPORTING
i_logo
= 'ENJOYSAP_LOGO'
it_list_commentary = i_list_top_of_page.
ENDFORM.