Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

BN o RD, C T BN BN BN RD, C Group RD, C

Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 2

Reactions:

V=
N=
Nc =

2.5 kN
5.57 kN

v=
h=
=

3 m
0.9 m
16.70 Deg

F=

6.11 kN

Uplift
Compression

Footing:
D
0.3 m
H
0.8 m
Weight of footing =

1.36 kN

Width of plinth for upli


Weight of Plinth =

2 m
6.72 kN

Hilti Anchor =

M12

Concrete = fc'
Thickness of Concrete member =
Edge distance = c =
Total Anchors =
spacing s1 =
spacing s2 =
fBN =

HVU

with HAS adhesive Anchor


20
200
100
2
100
0

Mpa
mm
mm
Nos
mm
mm

1.14 for 32MPa

NoRd,c =
fT =
fBN =
fBN =
fBN =
NRd,c =

5.57 kN (initial value of design tensile resistance)


1 (Influence fo anchor depth:standard embedment)
0.82
0.78
0.86
3.492746 kN (initial value of design tensile resistance)

NgroupRd,c =

6.985491 kN

NRd,c =
NgroupRd,c =
fBN =
fBN =

48.1 kN (for a single anchor, HAS rod grade 5.8 steel)