Enerflow ERHP SU Specs Aug2013
Enerflow ERHP SU Specs Aug2013
Enerflow ERHP SU Specs Aug2013
Note
Model
Unit
Refrigerant type
ERHP-SU08-MS
ERHP-SU14-MS
ERHP-SU26-MS
ERHP-SU08-PL
ERHP-SU14-PL
R410a
R410a
R410a
R410a
R410a
Mass of Refrigerant
540
1020
2000
550
860
230/1ph
230/1ph
230/1ph
230/1ph
230/1ph
Hz
50
50
50
50
50
2.73
5.68
3.32
4.8
kW
0.6
1.25
1.97
0.73
1.05
W/W
3.33
3.66
3.44
3.15
3.4
kW
9.7
3.6
kW
30 ~ 55 ~ 75
30 ~ 55 ~ 75
30 ~ 55 ~ 75
30 ~ 55 ~ 75
30 ~ 55 ~ 75
75
75
75
75
75
43
43
43
43
43
-5
-5
-5
-5
-5
150-300
100 200
150-300
200-500
100-200
MPa
0.7
0.7
0.7
0.7
0.7
Inch
3/4"
3/4"
3/4"
3/4"
3/4"
IPX4
IPX4
IPX4
IPX4
IPX4
Electro Galvanised
Powder Coated
Electro Galvanised
Powder Coated
Electro Galvanised
Powder Coated
UV resistant plastic
UV resistant plastic
dBA
<55
<55
<64
<55
<55
kg
~43
~58
~82
~38
~51
Net Dimension
wxdxh
Packing Dimension
wxdxh
1 Testing conditions:
Ambient Temperature DB 20C / WB 15C.
Complete water heating cycle 15C to 55C.
2 Ambient temperature of 30C.
3 Heat pump output for backup element.
4 Water temperature will reach 55C using the heat pump only. However if the water temperature needs to reach 75C,
the electric heater will be activated automatically above 55C until the required temperature is reached.