API 653 Quiz 1answers
API 653 Quiz 1answers
API 653 Quiz 1answers
Quiz # 1 Answers
1. What is the minimum temperature that a section of A 516 Grade 60 as-rolled plate may be
used in fabrication of an Aboveground Storage Tank without impact testing? The material
thickness is .875 inch.
A. Approximately -40F
B. Approximately 28F
C. Approximately -17F
D. Approximately 17F
Answer: C: Reference API-650 Figure 2-1 and 2-3b (curve III)
2. When new or unused plate and pipe material cannot be completely identified to the
satisfaction of the purchaser as conforming to a specification listed in API-650, the material
may be used in construction of tanks only if it complies with which Appendix of API-650?
A. Appendix A
B. Appendix G
C. Appendix M
D. Appendix N
Answer: D: Reference API-650 Paragraph 2.1.2 and Appendix N
3. Is it possible for a single Welding Procedure Specification to cover a thickness range from
1/16 through 1 ?
A. Yes as long as a supporting Procedure Qualification Record exists for both 1/16 through
3/16 and 3/16 through 1 thickness ranges
B. Yes as long as a supporting Procedure Qualification Record exists for the 1/16 through 1
thickness range
C. No the WPS can only cover one thickness range
D. No the WPS can only cover a single essential variable regardless of the number of
supporting PQRs exist.
Answer: A: Reference ASME Section IX Paragraph QW-200.2(f)
4. What is the hydrostatic test thickness based on the second course of a new AST that is 124
feet in diameter and 48 feet high. The shell courses are 8 feet high each and fabricated of A
516 Grade 55 material. The purchaser orders a corrosion allowance of .0625 and the product
to be stored will have a specific gravity of .87.
A. .596
B. .536
C. .559
D. .629
tt
2.6 D ( H 1)
(2.6)(124)(40 1)
tt
St
22500
tt
12573.6
.5588"
22500
(610) 594-9036
Which of the following would be a true statement regarding placement of hole type Image
Quality Indicators in radiographic examination?
A. The Image Quality Indicator shall be placed adjacent to the weld
B. The Image Quality Indicator shall be placed adjacent to the weld with the identifying
number facing left
C. The Image Quality Indicator may be placed on or adjacent to the weld provided when the
Image Quality Indicator is placed on the weld, the next smaller size Image Quality
Indicator is used
D. The Image Quality Indicator may be placed on or adjacent to the weld
(610) 594-9036
7. When design and construction details are not given and not available in the as-built standard,
then details that will provide a level of integrity equal to the current edition of what Code or
Standard must be used?
a) ASME Section VIII, Division 1, Pressure Vessels
b) ASME Section VIII Division 2, Alternative Rules for Pressure Vessels
c) API- 650, Welded Steel Tanks for Oil Storage
d) API-12C Steel Storage Tanks for Oil Storage
Answer c) Reference: API-653 Paragraph 1.1.5
8. Iron sulfide corrosion is _____ to the base steel and may promote pitting by a galvanic corrosion
mechanism.
a) An anode
b) Ionic
c) Cationic
d) Cathodic
Answer: d): Reference API-652, Paragraph 4.5
9. The two most common types of corrosion to tank bottoms are ______ and ______.
a) Stress corrosion and galvanic
b) Erosion and erosion/corrosion
c) General and pitting
d) Stray current and bimetallic
Answer: c): Reference API-651, Paragraph 4.1.2
(610) 594-9036
(610) 594-9036