Api 510

This document provides calculations for corrosion rate and remaining life of equipment according to API 510 standards. It calculates the long-term and short-term corrosion rates of a test separator using thickness measurements taken over various time intervals. The short-term corrosion rate is determined to be 0.1 inches/year. The remaining life is calculated to be 1 year using the short-term corrosion rate and the actual thickness and required minimum thickness. The next inspection date is recommended to be within 0.5 years or by February 9, 2015, whichever comes first.

Uploaded by

dandiar1
Copyright
© © All Rights Reserved
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
100% found this document useful (2 votes)
2K views

Api 510

This document provides calculations for corrosion rate and remaining life of equipment according to API 510 standards. It calculates the long-term and short-term corrosion rates of a test separator using thickness measurements taken over various time intervals. The short-term corrosion rate is determined to be 0.1 inches/year. The remaining life is calculated to be 1 year using the short-term corrosion rate and the actual thickness and required minimum thickness. The next inspection date is recommended to be within 0.5 years or by February 9, 2015, whichever comes first.

Uploaded by

dandiar1
Copyright
© © All Rights Reserved
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 4

API 510 Corrosion Rate and Remaining Life Calculations

Plant ID
Equipment Number:
Equipment Name:
Equipment Type:
Date:

Plant
1234
Test Separator
Vessel
August 11, 2014

Corrosion Rate Determination


Reference: API 510, 10th edition, 7.1.1
The long-term (LT) corrosion rate shall be calculated from the following formula:

Corrosion rate (LT) =

tinitial - tactual
time between tinitial and tactual (years)

The short-term (ST) corrosion rate shall be calculated from the following formula:

Corrosion rate (ST) =

tprevious - tactual
time between tprevious and tactual (years)

Corrosion Rate (LT)


tinitial
date

0.413

Corrosion Rate (ST)


date tprevious

0.5

tactual

0.352

date

tactual

0.4

interval (years)
Corrosion rate in/yr:

5.0
0.012

date

interval (years) 1.000


Corrosion rate in/yr: 0.100

Remaining Life Calculation


Reference: API 510, 10th edition 7.2.1
The remaining life of the vessel (in years) shall be calculated from the following formula:

Remaining life =

tactual - trequired
corrosion rate (ST)

Remaining Life
tactual
trequired
corrosion rate
Years:

1/2 Remaining Life


0.4

Remaining life (years)

1.000

0.3
0.100
1.00

Years:

0.50

The period between internal or on-stream inspections and thickness measurement inspections shall not exceed one-half the remainin
vessel or 10 years, whichever is less (API 510, 10th edition, 6.5.1.1).
Each aboveground vessel shall be given a visual external inspection at an interval that does not exceed the the lesser of five years or
internal/on-stream inspection (API 510, 10th edition, 6.4.1).

Next inspection due date:


February 9, 2015

all be calculated from the following formula:

ckness measurement inspections shall not exceed one-half the remaining life of the

pection at an interval that does not exceed the the lesser of five years or the required