C925A - TPC Station


GL3 GLASS BALUSTRADE AT CONCOURSE
ANCHOR BOLT SHOCK CALCULATION
Standard shock design form
Applied loading is computed based on LTA civil defence shelter's requirements.
The concrete is cracked
Concrete strength, fck 15 N/mm2.
Fixture is rigid enough to distribute applied tension load equally to all anchors in an anchor group.
Anchor design is done for the most unfavourable anchor. This is the anchor with the most
combination of loading and geometrical constaints (edge distance , spacing).

unfavourable

Input "0", if no Spacing or edge distance is required.


FZA 22x100 M12 I A4

Type of anchor
h

200

s1

210

s2

210

s3

c1

c2

Design tension action

hmin
(Sect 2)
smin (Sect
2)

h / hmin

200

si / smin

210

cmin
(Sect 2)

100

NGSd

17.9

ci / cmin
Number of anchors in the group
acting in tension

1.00

1.0

1.00

1.0

1.00

1.0

0.00

1.0

0.00

1.0

0.00

1.0

NSd

17.90

VSd

2.58

RSd

18.08

Steel resistance

NRd,s

29.50

Sect 2

Pullout resistance

Rclass

27.10

Sect 2

fb,N

1.10

NRd,p

27.10

N0Rd,c

24.00

Sect 2

fs1

0.85

1.0

fs2

0.85

1.0

fs3

0.00

1.0

fc1

0.00

1.0

fc2

0.00

1.0

NRd,c
RRd

19.00

NSd =
Design shear action

VGSd

2.58

Design resultant action on single anchor

Number of anchors in the group


acting in shear

VSd =

Shear action acting on single anchor

Calculation of resistance

Concrete strength

fck

30

fb,N =

NRd,p = Rclass
Concrete cone resistance in cracked concrete
s1

210

s2

210

s3

c1

c2

scr,N
(Sect 2)
ccr,N (Sect
2)

300

150

fsi = +
fci =

x 0.5

N0Rd,c x fb,N x fsi

NRd,c =
x fci
RRd = min (NRd,s ; NRd,p ; NRd,c)

Design resultant resistance


19.00
Decisive design proof
RSd / RRd
0.95
* The Calculation results are proposals only; it should be final checked and approved by the engineers
responsible for the project.