Caps/collars
Surface mounting
istameter m
Item no. 15521 hot
Item no. 15621 cold
Flush mounting
Installation on
shut-off valve
Mounting parts
Accessories
Connecting
dimension
SPC press
connection
Mounting blocks
Connecting
dimension
Style
Item
no.
80
14110
R 1/2
Brass
17000
G 3/4 B
110
14103
15 mm
Solder
17005
G1B
105
14403
18 mm
Solder
17006
G1B
130
14404*
R 3/4
Brass
17100
G1B
130
14414
22 mm
Solder
17105
G1B
190
14408*
Rp 1/2
94
14000
Rp 1/2
94
14011*
Rp 3/4
100
14100
Rp /4
100
14012*
15 mm
94
14200
15 mm
94
14013*
18 mm
100
14300
18 mm
100
14014*
22 mm
105
14400
22 mm
105
14015*
28 mm
190
14402*
15 mm
145
14008*
18 mm
145
14009*
22 mm
145
14010*
Duo eco
Rp 3/4 IG
39995
Duo perfect
Rp 3/4 IG
39990
Mounting parts
Installation kit
Item no.
VCP, horizontal
Horizontal
13880
VCP, vertical
Bathtub /
shower fixtures
Item no.
G 3/4 B
SPC solder
connection
Installation
length
Vertical
13879
Item no.
20 mm
15003
40 mm
15004
Flow direction
converter
14903
Supplement kit
Item
no.
Extension kit
Item
no.
R 1/2
13022
R 1/2
20 mm
13621
R /2 short
13030
R /2
60 mm
13623
R 3/4
13122
R 3/4
20 mm
13631
R /4 short
13130
R /4
60 mm
13633
R1
13222
R1
20 mm
13641
R 1 short
13230
R1
60 mm
13643
Set for
1 istameter m
17550
2 istameter m
17560
istameter m
the modularly upgradeable water meter
Performance features
As a fully-dry meter, the istameter m guarantees
increased operating safety and measurement
precision. The counter does not come into
contact with the flowing water no deposits are
left behind in the counter. The istameter m
water meter is installed using mounting parts
(e.g. SPC single-pipe connection piece, VCP
valve connector). Thanks to this modular
design, only the meter must be replaced during
an exchange, e.g. when the calibration term has
expired.
The istameter m can be installed horizontally
or vertically. The counter can be turned to the
most favourable position.
6
Areas of use
The complete istameter m system with meters,
mounting parts and accessories offers multiple
options for use in residential areas:
as a flush-mounted meter
as a surface-mounted meter
on the shut-off valve
on the bathtub or shower fixtures
under the bathroom or kitchen sinks
in pre-installed flush-mounted boxes
Thanks to its single pipe connection (SPC),
the istameter m can be universally mounted
on almost all customary installations. Once
mounted, the SPC remains permanently
attached to the installation.
Mounting the istameter m to existing supply
lines, e.g. during renovation of old buildings,
is not a problem thanks to the valve
connector (VCP). The istameter m system is
supplemented by accessories and mounting
aids.
Benefits to You
Trend setting technology through
modular composition
Complete metering system for
cold and hot water in residential
properties
Easy replacement by separating
the meter from the mounting
parts
Broad spectrum of use due to
high diversity of designs
Precise measurement and
reliability
Available with nominal flow rates
of Qn 1.5 m3/h and Qn 2.5 m3/h
Functional description
istameter m cold and hot water meters are
multi-jet impeller meters with magnetic
coupling and roller-type counters. The
advantage of the multi-jet impeller meter is
the uniform load on the impeller and thus its
high measuring stability. The magnetic
coupling transfers the rotation of the impeller
onto the counter.
The istameter m principle is a coaxial
principle. This means that the water inflow
and outflow through the meter takes place in
concentrically-arranged inflow and outflow
channels with large cross sections. This
provides for dimensional stability, very little
loss in pressure, and a trouble-free seal between
the meter and the mounting parts.
istameter m is a classic among residential
water meters, with a modern design.
The istameter m principle is synonymous
with a technically mature, complete
measuring system.
istameter m
64.5
74.8
58.6
Dimensions in mm
Technical data
Device type
istameter m
Measuring principle
hot 1.5
Design
hot 2.5
15621
15523
15521
Item number
cold 2.5
15623
Qn (m3/h)
1.5
2.5
Qmax (m3/h)
3.0
5.0
p (bar)
0.2
0.2
Qmin (l/h)
30
50
Qt (l/h)
120
200
Qmin (l/h)
60
100
150
Qt (l/h)
Nominal temperature (water)
up to C
Nominal pressure
PN (bar)
Testing pressure
PN (bar)
250
90
30
90
30
10
Protection class
10
16
16
5-digit
5-digit
m3
3-digit
3-digit
L 15, L 18, L 22
Rp 3/4, G 3/4 B, G 1 B
P 15, P 18, L 22
P 22
R /2, R /4, R 1
l
Connecting thread, SPC mounting parts
6 years*
5 years in Austria
p [bar]
1
0.5
0.4
0.3
Error [%]
+3
+1
1
0.2
istameter m hot
+4
+2
0.1
istameter m cold
0.05
0.04
0.03
2
3
4
5
0.02
0.01
0.005
0.004
0.003
0.002
0.01
0.02
5 years
Calibration validity
+5
L 22, L 28
EN 14154-3
Magnetic protection
cold 1.5
0.1
0.2
0.7
1.5
EN 14154-3
5 years
6 years*
Q [m3/h]
istameter m
system-compatible with module contact
Technical data
Device type
Item no.
Contact sequence l/pulse
Contact module
19404
19408
19409
19412
10
100
10
without Namur
Contact
Pulse duration
with Namur
every 2 sec.
Pulse output
250 ms.
3 sec.
3 sec.
3 sec.
> 3 sec.
> 3 sec.
> 3 sec.
Contact open
> 6 M
> 6 M
> 6 M
> 12 k
Contact closed
100
100
100
1,86 k
Pulse pause
30 V
Max. voltage
Assembly
Transmission technology
Cable length
2 x 0.25 mm2
IP 65
Protection class
Temperature ranges
+ 5 to + 55 C
Environment
Storage
5 to + 45 C
Transportation
20 to + 80C
12 years + 1 year storage + 1 year reserve
Lifetime
100
64.5
74.8
10.2
33.9
64.5
68.8
Dimensions in mm
2.2 k
12 k
Dimensions in mm
2.0
1.0
0.8
0.6
0.4
0.3
0.2
0.1
0.08
0.06
0.04
0.02
0.01
0.008
0.006
0.004
0.002
0.001
0.04
0.06
0.08
0.1
0.2
10
0.4
0.6
0.8
1.5
2.4
Flow rate
in m3/h
2.0
1.0
0.8
0.6
0.4
0.3
0.2
0.1
0.08
0.06
0.04
0.02
0.01
0.008
0.006
0.004
0.002
0.001
0.1
0.2
0.4
0.8
2.5
Flow rate
in m3/h
11
Performance features
The single-pipe connection pieces (SPC) are
made of brass. Designs in high-grade red
brass are also alternatively available. The red
brass SPC are the ideal design for use with
hard water. SPC are available in different
variations if needed e.g. with female
or male threads, solder/press connection, and
in diverse mounting lengths.
Functional description
The single-pipe connection piece (SPC) is
used to mount the istameter m water meter. It
can be mounted universally on all
conventional pipe types and installations,
either horizontally or vertically, and remains
permanently attached to the installation.
Once the SPC is mounted, the overcurrent cap
supplied seals the meter connection.
Areas of use
Thanks to its many variants, the SPC can be
mounted in almost all conventional pipe
types, both horizontally and vertically.
12
Benefits to You
Proven, technically mature,
complete measuring system
("istameter m principle") for cold
and hot water in the residential
area
Easy replacement by separating
the meter from the mounting
parts
Broad spectrum of use thanks to
high number of variants
Technical data
Female thread*
Design
Item no. SPC
Brass MS 58
Nominal pressure
PN bar
Testing pressure
PN bar
Red brass RG 5
14011
10
14012
14404
10
16
Rp 1/2
Rp 3/4
29.0
29.0
94
88.9
R 1/2"
Rp 1/2
100
88.9
99.9
90
G 3/4 B
110
80
130
29.0
36.0
37.0
88.9
97.9
96.9
R 3/4" R 3/4"
R 1"
R /2
R /4
G1B
105
29.0
190
88.9
94
37.0
29.0
96.9
88.9
R 1"
15
R /4
G1B
G1B
R /2
R 1"
R /4
10
10
90
90
16
15 mm 18 mm 22 mm 28 mm 15 mm 18 mm 22 mm
107.9 99.9
16
99.9
R 3/4"
Press connection*
100
29.0
105
29.0
130
88.9
88.9
99.9
99.9
18
22
145
37.0
33.5
33.5
33.5
96.9
93.4
93.4
93.4
28
15
18
22
17100
17005 15 mm 17105 22 mm
Solder
17006 18 mm
125.0
59.9
Height in mm (H)
75.0
64.5
58.0
Section in mm (C)
48.6
11.0
17000
Thread
Solder connection*
16
90
Nominal temperature up to C
Male thread
Connection dimensions
B
L
C
min. 10
B1
Overcurrent cap
Mounting aid
M
N
max. 35
Press ring
h
G
L
E
Profile sealing
SPC housing
Dimensions in mm
13
Mounting block
the clean solution
With mounting block
Benefits to You
Clean and time-saving installation, can be directly tiled
Optimal heat insulation thanks to two-component PU foam according to
DIN 3067/2 DVGW, heat loss values fall clearly below EnEV (Energy Saving
Ordinance) guide values for heat loss
Optimal sound absorption, noise insulation according to DIN 4109
Flammability rating B2 (flame-resistant)
Can be universally mounted on masonry or front-wall installation systems
thanks to stable, fold-out fastening clamps
Additional mounting angle for direct wall mounting
Delivered ready to mount, completely piped, and tested for tightness
Design
Connection
Item no.
Mounting block
Duo eco
Rp 3/4 IG
39995
15
All mounting parts are provided with protective caps, fully piped and
leak-tested. They are also laid in high-grade, pressure-resistant, twocomponent PU foam of high tensile strength, providing heat
insulation and sound absorption. The PU foam is of flammability
rating B2 and can be easily tiled.
Dimensions in mm
16
Design
Connection
Item no.
Mounting block
Duo perfect
Rp 3/4 IG
39990
Installation depth
Item no.
0-35 mm
45515
0-35 mm
45516
35-90 mm
45512
35-90 mm
45513
Control handle
70
15
0-35
Dimensions in mm
61
15
35-90
Dimensions in mm
17
18
Benefits to You
Proven, technically mature,
complete measuring system
(istameter m principle) for cold
and hot water in the residential
area
Easy replacement by separating
the meter from the mounting
parts
Variants for vertical and
horizontal installation
Precise measurement and
reliability
High-grade ceramic shut-off
valve guarantees durable and
easy shut-off
Special variants, e.g. for Rp 1 1/4
shut-off valves are available
Technical data
Vertical installation
Horizontal installation
Connection
R 1/2
PN bar
Testing pressure
PN bar
R 3/4
13879
13022
13122
13030
13130
16
90
Installation dimensions in mm
163
L
l1
110
PN bar
Testing pressure
PN bar
Installation dimensions in mm
Installation length
Diameter
20 mm
60 mm
13621
l1
R 3/4
13022
13122
13030
16
90
143
146
20 mm
90
13633
13641
13643
60 mm
143
30
25
13230
10
Diameter
13222
13130
119
83
R1
13880
H
Installation height
13631
13623
65
90
163
30
h1
R 1/2
135
h2
Connection
166
H
Installation height
13222
13230
10
R1
83
13621
13631
13623
13641
13633
13643
Pressure loss
p [bar]
4.0
2.0
h2
1.0
0.8
0.6
0.4
0.3
0.2
0.1
0.08
0.06
0.04
l1
0.02
In connection with
SPC R 1/2
In connection with
SPC R 3/4, R 1
0.01
0.008
0.006
0.004
l1
0.002
0.001
0.04
h1
0.08
0.06
0.1
0.2
0.4
0.6
0.8
1.5
2.4 3
2 2.5
d
L
19
20
Bathtub installation
Flush-mounted installation
10
5
120
R 1/2
2
110
90
183
45
2
G /4 B
3
G 3/4
42
1
98 76
105
46
23
25
9
138
95
80
190
100
Dimensions in mm
Item no.
17550
Dimensions in mm
Item no.
17503
17560
14103
Accessories
Item no.
istameter m hot
15521
istameter m hot
15521
istameter m cold
15621
istameter m cold
15621
15318
15318
Cap, short,
chrome-plated
17516
to 5
17500
Pos.
Dimensions in mm
Description
Item no.
Wall collar,
chrome-plated
14111
Cap, chrome-plated
15300
istameter m hot
15521
istameter m cold
15621
SPC G 3/4 B, 80 mm
14110
Flush-mounted boxes,
pre-installed
Pos.
21
68.5
68.5
x = 23
33.5
54.5
G2B
53
54.5
G2B
Dimensions in mm
22
x = 41
75.5
x = 31
44
54.5
G2B
Dimensions in mm
Dimensions in mm
Installation instructions
When installing the istameter m, neither hemp
nor sealing compounds may be used. The
istameter seals with the profile sealing. The
meter must be screwed in using the installation
wrench up to the fixed stop between the
mounting part and the istameter m.
23
domaqua m
the modularly upgradeable surface-mounted
water meter
Performance features
As a dry meter, the domaqua m offers the
assurance of high measuring precision and a
long life. The penetration of foreign particles
or deposits in the roller counter is impossible.
Furthermore the housing prevents any splash
water from entering.
24
Benefits to You
Trendsetting technology thanks
to modular design
Broad spectrum of use due to
high number of variants
Reliable and durable thanks to
fully developed technology
Available with nominal flow rates
of Qn 1.5 m3/h and Qn 2.5 m3/h as
well as installation lengths of 80,
110 and 130 mm
Can be retrofitted with contact
module
Technical data
domaqua m
Device type
Measuring principle
hot 1.5
Design
16094
Item number
16095
cold 1.5
16096
16090
16091
16092
hot 2.5
cold 2.5
16097
16093
Qn (m3/h)
1.5
2.5
Qmax (m3/h)
3.0
5.0
p bar
0.17
0.25
Qmin (l/h)
30
50
Qt (l/h)
120
200
Qmin (l/h)
60
100
up to C
Nominal pressure
PN (bar)
10
10
Testing pressure
PN (bar)
16
16
150
Qt (l/h)
250
90
30
90
30
Protection class
EN 14154-3
Magnetic protection
Water consumption count
5-digit
5-digit
3-digit
3-digit
Installation dimensions in mm
Installation length
L/L1
80/160
Installation height
H/H1
54.5/16
110/190
54.5/16
110/190
130/210
52.5/16
130/227
52.5/16
10.2
10.2
G /4 B
G1B
R /2
R 3/4
Brass
17000
17100
Chrome-plated
17200
17300
Solder
5 years
80/160
52.5/16
130/210
6 years*
5 years
6 years*
5 years in Austria
domaqua m
H2
H1
H1
L1
L1
25
domaqua m
system-compatible with module contact
26
Technical data
Device type
Item no.
Contact sequence l/pulse
Contact module
19404
19408
19409
19412
10
100
10
without Namur
Contact
Pulse duration
250 ms.
3 sec.
3 sec.
3 sec.
> 3 sec.
> 3 sec.
> 3 sec.
Contact open
> 6 M
> 6 M
> 6 M
> 12 k
Contact closed
100
100
100
1,86 k
Pulse pause
30 V
Max. voltage
Assembly
Transmission technology
Cable length
2 x 0.25 mm2
IP 65
Protection class
Temperature ranges
+ 5 to + 55 C
Environment
with Namur
every 2 sec.
Pulse output
Storage
5 to + 45 C
Transportation
20 to + 80C
12 years + 1 year storage + 1 year reserve
Lifetime
100
10.2
33.9
64.5
2,2 k
12 k
Dimensions in mm
27
Flush mounting
domaqua m water meters for flush-mounting
come in complete sets. Their core piece is the
domaqua m with an installation length of 80
mm. The meter is installed in a flushmounted box that is covered by a chromeplated square collar. Equalising rings can be
used to compensate the height of deep-lying
flush-mounted boxes.
Dimens.
Type
Item no.
16040
R /2
Corner valve
17402
1.5
16041
R 3/4
Corner valve
17403
cold
1.5
16042
R /2
17400
R 1/2 15 mm
hot
1.5
16050
Corner screw
connection
R 3/4 18 mm
hot
1.5
16051
R 3/4
17401
22 mm
hot
1.5
16052
Corner screw
connection
Dimens.
Type
Qnm3/h
R /2 15 mm
cold
1.5
R 3/4 18 mm
cold
22 mm
Item no.
16022
Flush-mounted boxes
domaqua m Qn 1.5 m3/h,
80 mm, hot or cold
Square collar, 137 mm
Alternatively, square collar,
180 mm
14109
Flush mounting
mm
Description
Item no.
Special screw
connection
17503
domaqua m hot
16094
domaqua m cold
16090
Special screw
connection
17516
Altern. to 3, flex.
pressure hose
17500
17312
Position
Qn 1,5
Qn 2.5
80/110/130
130
L1 = min
156/186/206
207
L = max
166/196/216
217
L2 =
40
40
L3 = min
36
37
L3 = max
46
47
H=
60
55
10
H1 =
80
80
L=
80
115
L2
2 75
28
42
L1
137
L3
28
H1
55
55
1
2
80
435
80
H
118
3104
190
Dimensions in mm
28
Dimensions in mm
4
10
Pressure loss
p in bar
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.25
Pressure loss
with Qn 2.5
Pressure loss
with Qn 1.5
0.17
0.1
0.09
0.08
0.07
0.06
0.05
0.04
0.03
0.02
0.01
0.5
0.6
0.7
Qn 1.5
2.0
Qn 2.5
3.0
4.0
5.0
Flow rate
in m3/h
Qn 1.5 m3/h
Qn 2.5 m3/h
29
H
h
L
L1
30
H
L1
L
h
Technical data
Multi-jet
Design
16773*
16779*
Qn (m3/h)
Maximum load
Qmax (m3/h)
Cut-off limit
Lower measurement range limit
16774*
16775*
16786
16787
16776*/**
16777*/**
16778*/**
16780*
16785
2.5
16776*
16781*
16777*
16782*
10
2.5
16783*
6
16778*
16784*
10
12
20
12
20
Qt (m3/h)
0.25
0.6
1.0
0.25
0.6
1.0
Qmin (l/h)
50
90
160
20/70***
40/160***
80/350***
Nominal width
DN
20
25
40
20
25
40
Installation length
L/L1
190/288
260/378
300/438
190/288
260/378
300/438
Installation height
H/h
136/41
147/44
161/46
120/41
130/44
150/46
Width
Dimension
drawing 2: Riser/
downpipe design
Dimension
drawing 1:
horiz. design
Installation dimensions in mm
96
102
137
98
104
137
G1B
G2B
G1B
R 3/4
R 1 1/2
R 3/4
G 1 1/4 B
G2B
G 1 1/4 B
R1
R1
R 1 1/2
Installation length
L/L1
105/203
150/268
200/338
105/203
150/268
200/338
Installation height
H/h
135/18
145/22
157/46
118/18
130/22
147/46
Width
96
102
136
98
101
136
G1B
G2B
G1B
R 3/4
R1
R 1 1/2
R 3/4
1 /4 B
G2B
G 1 /4 B
R1
R 1 1/2
17100
31800
17105 22 mm
Solder
17110 28 mm
90 (120)
31802
17100
31812 42 mm
17105 22 mm
31800
17110 28 mm
30 (50)
Nominal pressure
PN bar
10
Testing pressure
PN bar
16
31802
31812 42 mm
16791
Item no.
Contact sequence
Litres/pulse
Cable length
Metres
Protection type
100
3
IP 68
max. 24 V DC, 50 mA
Contact load
Residential water meters with integrated pulse output
16788
16789
(Litres/pulse )
Cable length
Meters
**
5 years
Calibration validity
*
16790
***
****
6 years****
0.2
Pressure
flow at
Qn 6
Pressure
flow at
Qn 2.5
0.1
0.08
Pressure flow
at Qn 10
0.06
0.04
Hot water
Cold water
0.02
0.01
0.6
0.8
2.0
2.5
4.0
6.0
8.0
10
12
20 22 24
Flow in
40 m3/h
0.2
Pressure flow
at Qn 6
Pressure flow
at Qn 10
0.1
0.08
0.06
0.04
Hot water
Cold water
0.02
0.01
32
0.6
0.8
1.0
2.0
2.5
4.0
6.0
8.0
10
12
Flow in
40 m3/h
WS
DN
50-150
WP
DN
50-150
Explanations
DN
Nominal width in mm
33
Technical data
Design
Item no. Horizontal design
Item no. Riser pipe design
Item no. Downpipe design
Nominal flow rate
Maximum load
Cut-off limit
Lower measurement range limit
Weight
Maximum load
Cut-off limit
Lower measurement range limit
Weight
Installations dimensions in mm
Nominal width
Dimension drawing 1 installation length
Horizontal installation height
WS
WP
WP
Qn (m3/h)
Qmax (m3/h)
Qt (m3/h)
Qmin (l/h)
kg
Qmax (m3/h)
Qt (m3/h)
Qmin (l/h)
kg
16723
16733
16753
15
50
1.5
0.2
14.2
70
2.25
0.6
14.3
Hot water
16724
16725
16734
16735
16754
16755
40
60
110
140
1.6
2.4
0.3
0.4
24
28
150
180
6
9
1.6
2.0
18.2
19.8
DN
L
H/h
50
270
155/84
80
300
90/102
L
H/h
D
D1
200
200/75
165
125
18
4
225
200/92
200
160
16703
16713
16743
15
50
1.5
0.2
14.5
90
1
0.3
10.2
100
360
200/113
150
500
400/155
50
270
135/85
80
300
180/102
100
360
190/113
150
500
351/141
250
200/110
220
180
300
217/145
285
240
22
8
200
123/75
165
125
18
4
225
140/94
200
160
250
140/106
220
180
300
212/135
285
240
22
8
18
8
90 (120)
10
16
10
8-digit
16891
1.000
10.000
100
1.000
5 years
Hot water
Cold water
Cold water
16704
16705
16714
16715
16744
16745
40
60
110
180
2.5
3
0.25
0.3
24
28
200
250
2
2
0.5
0.6
14.1
19.1
16726
16736
16756
150
350
15
2.0
79.5
350
22.5
4.5
32.5
1
7-digit
l/Imp.
Woltman meter
18
8
30 (50)
16706
16716
16746
150
350
10
0.8
79.5
425
12
2.5
32.5
1
7-digit
10
8-digit
100
1.000
1.000
10.000
6 years*
5 years in Austria
Dimension drawing 1: WS series
D1
h
L
34
D1
h
L
0.2
0.1
0.08
Pressure flow
at Qn 40
Pressure flow
at Qn 15
0.06
Pressure flow
at Qn 60
Pressure flow
at Qn 150
0.04
0.02
0.01
10
15
20
40
60 100
140 150
200
500
Flow in
m3/h
Flow in
m3/h
0.2
0.1
0.08
0.06
0.04
Pressure flow
at Qn 40
0.02
0.01
Pressure flow
Pressure flow
at Qn 60
at Qn 150
Pressure flow
at Qn 15
5
10
15
20
30
40
60
80 100
125 150
200
35
38
39
81016/XI-12