CENTUM VP System Introduction
CENTUM VP System Introduction
CENTUM VP System Introduction
2
History
Yokogawa has released the CENTUM system as the world first DCS in 1975. Then we
continuously providing the new DCS products based on the latest technologies and
customers feedback with keeping the compatibility with former Yokogawa system not to
bother our customers.
Based on our 30-year DCS experience, Yokogawa is proud to introduce the new CENTUM VP
system.
Project Experience
As of September 2007, Yokogawa has
almost 20,000 project experiences for various industries application such as oil & gas
upstream/downstream, chemical, petrochemical, pulp & paper, iron, metal, power, pharmaceutical, food &
beverage, etc. all over the world.
3
System Architecture
Plant LAN or
Corporate LAN
HIS
PIMS,
Historian etc.
HIS/ENG
Exaopc
Server
Terminal
Server
1Gbps Redundant
Control LAN (Vnet/IP)
SIOS/GSGW
FCS
APCS
OPC Server of other
PCSs or subsystems.
(PLC, MCC, etc)
Ethernet
ESB bus
Subsystems
(PLC, MCC, etc.)
Expansion
I/O nodes
ER bus
Component
An
availability
FCS
performs
is
process
achieved
by
control.
the
High
unique
Open
Display
Style
Console
Assembly,
Terminal Server
Server
Control LAN
Exaopc Server
domain systems.
SIOS, GSGW
CENTUM VP system.
Bus converters
and Micro-XL
5
System Specification
System overall
Up to 256 stations can be in one CENTUM VP
FCS
system.
HIS
Graphic
One HIS can have up to 4,000 graphics. Each
graphic can have 800 process data on it, and 1
second data refresh is available. One HIS can
have up to 4 monitors, and up to 10 graphics can
be displayed at the same time with regardless the
number of monitors. Frequently used combination
of the graphics and other display components can
be pasted on a frame, and the set of those can be
call up quickly.
Trend
One FCS has 8 slots for I/O module, and you can
gathering period.
redundant.
operator,
or
work
overload
for
operators
ER bus
Interface modules
FCS
FCS
ESB bus
ER bus
Expansion
I/O nodes
Optical
fiber
Expansion
I/O nodes
out via
cables etc.
The engineers
Network (Vnet/IP)
7
Operation Environment
[Intrinsic Safety]
EN 50014 1997 +A1 +A2
EN 50020 1994
EN 50021 1999
0 50 deg C.
*2: A lightning arrestor or the like is required to meet this surge immunity
standard.
V AC, or 24 V DC.
Regulatory Compliance
standard.
[CSA]
*4: The specified limits of voltage drops across wiring must be satisfied to
(*2)
[C-Tick Mark]
AS/NZS 2064 (for 220-240 V AC and 24 V DC power supply)
Note: According to the New Approach Directive, the manufacturer and the
8
Trademark
CENTUM, Vnet/IP, DARWIN, DAQSTATION ProSafe
and Exaopc are registered trademarks of Yokogawa
Electric Corporation.
Exaplog and Exapilot are trademarks of Yokogawa
Electric Corporation.
Windows is a registered trademark of Microsoft
Corporation in the United States and/or other countries.
Ethernet is a registered trademark of XEROX
Corporation.
Modbus is a registered trademark of Schneider Electric
and/or such related companies.
PLC, PLC-5 and SLC500 are trademarks or registered
trademarks of Rockwell Automation, Inc.
MELSEC and MELSEC-A are registered trademarks of
Mitsubishi Electric Corporation.
SYSMAC is a registered trademark of Omron
Corporation.
FOUNDATION of FOUNDATION fieldbus is a
registered trademark of Fieldbus Foundation.
Other product and company names appearing in this
document are trademarks or registered trademarks of
their respective holders.